Background of Disease 1a Legionnaires' disease acquired its name in July 1976 when an outbreak of pneumonia and other respiratory illnesses occurred among.

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Outbreak investigation report Agnes Hajdu EpiTrain III, Jurmala, Latvia Based on EPIET material.
Where to Sample?. Objectives Environmental Sources of Legionella Determine Sources to Sample Tools Needed for Sampling How to Sample.
Legionellosis also known as legionnaires’ disease or legion fever By Brendan Purcell.
FOODBORNE OUTBREAK ASSOCIATED WITH FRIED RICE, HARDIN COUNTY, MAY 2006 ASHOKA INDUKURI EPIDEMIOLOGIST LINCOLN TRAIL DISTRICT HEALTH DEPT.
Chicago Department of Public Health Commissioner Bechara Choucair, M.D. City of Chicago Mayor Rahm Emanuel Legionellosis Outbreak Associated with a Hotel.
Field Epidemiology in Practice: A Hospital Outbreak of Acinetobacter Suzanne Beavers, M.D EIS Officer Kentucky Department for Public Health.
Principles of Outbreak Management
Why is Las Vegas Different Clark County has a population of 2 million 40 million visitors each year 150,000 hotel rooms 91% weekend occupancy.
Investigation of a Legionella Cluster
Embarking on an Outbreak Investigation. Goals The goals of this presentation are to discuss: The importance of verifying case reports Methods to determine.
Using GIS as a Tool for Investigating Outbreaks Adrienne Dunne CET, HPA East Midlands 15 th May 2007.
Legionella control in the University of Sheffield Legionella Awareness for Departmental representatives.
INDOOR AIR QUALITY ASSESSMENT. Why is preliminary assessment required ? To understand the current indoor air quality problems To develop a database on.
©2006 Armstrong International, Inc. Legionella. What is it and how do we treat it?
Legionella Matt Zahn, MD Medical Director Epidemiology and Assessment
UNIVERSITY POLICE OFFICE OF EMERGENCY MANAGEMENT H1N1 Presentation.
Presented by: Kim Chandler
LEGIONELLA AWARENESS COURSE. COURSE OBJECTIVES To enable you to be aware of issues associated with Legionella within the UoP & be able to assist in the.
An Outbreak of Legionnaires’ Disease in NHS Greater Glasgow and Clyde and NHS Lanarkshire 2011 Dr Sonya Scott StR Public Health NHS GGC
Outbreak of influenza A (H3N2) in a residence for mentally disabled persons in Ljubljana, Slovenia, 2013 Epidemiology and Public Health Valencia, Spain.
Influenza and the Nursing Home Population Julie L. Freshwater, PhD MPH Influenza Surveillance Coordinator 1.
Acute HIV Follow-Up in NC Presented by Muhammad “Maxi” Mackalo, DIS.
Legionella in thermostatic shower valves an exploratory field study J. Van Hoof (ISSO)L.M. Hornstra (KWR) O.W.W. Nuijten (ISSO)P.W.J.J. van der Wielen.
Food and Drug Administration & Outbreaks
Unit 3: Universal Case Reporting and Sentinel Surveillance for STIs
Investigation and Control of Outbreaks of Foodborne Illness Ralph Cordell, PhD.
Legionnaire’s Disease HPA Surveillance & Outbreak Management Rebecca Ingham Health Protection Practitioner West Yorkshire Health Protection Unit.
LEGIONELLA AWARENESS SEMINAR for the NORTH WEST WALES HEALTH AND SAFETY GROUP by Ken Ashley formerly HM Specialist Inspector HSE Dangerous Pathogens Section.
IOSH Essex Branch Event Event Subject: Legionella Awareness Date: 8 December 2010.
Water/Sanitation Yuriko Kubota. Nature of Water Composition of fresh water: 69.56% is frozen, 30.06% is groundwater, and the rest is lakes, soil moisture,
Infectious Disease Epidemiology, Module I Introduction.
بسم الله الرحمن الرحيم GENUS: LEGIONELLA Prof. Khalifa Sifaw Ghenghesh.
Christina Riggall, BS, RN, CNRN SUNY Institute of Technology.
Liberia Field Epidemiology Training Programme (LFETP)Liberia Field Epidemiology Training Programme LFETP) Report on Basic FETP Field Project 2 By Ruth.
Writing an Outbreak Report Dr Noorhaida Ujang Epid Officer Muar Alor Setar,
LEGGIONAIRES DISEASE Charlotte Wightman 10 Science 1/6/12.
Legionella Awareness East Anglia Construction Safety Group 23 April 2009.
Infectious disease e.g. cholera, typhoid are common in developing tropical countries. Epidemics are caused also by diseases other than infectious diseases.
Legionella and plumbing systems. Legionnaires' disease The first recognized cases of Legionnaires' disease occurred in 1976 in Philadelphia, Pennsylvania.
Nosocomial infection Hospital acquired infections.
Legionella Control & Management by Rami E. Kremesti M.Sc.
Legionnaires Disease – what landlords need to know! John Blackwood Chief Executive Scottish Association of Landlords.
MERS-CoV (Middle Eastern Respiratory Syndrome) Mike Wade – 16/06/15, updated 23/7/15.
Nosocomial infection Hospital acquired infections.
Infection Prevention Update – March 2016 Marie Kassai, RN, MPH, CIC.
Human Swine Influenza virus A (H1N1) Steven Skov Public Health Physician Centre for Disease Control As of 11 June 2009.
Legionella Awareness Phil Land H 2 O Chemicals Ltd 11 May 2011.
The aerosols released from a domestic spa pool: the potential risk to those in and around the pool BISHTA Annual Conference: 29 th September 2015 Ginny.
Legionnaires Disease in a Healthcare Facility Greg Osborne.
Kate Brierley Nurse Consultant in Health Protection Cumbria and Lancashire Health Protection Unit NW Regional Lead for HCAI March 2012 Legionella in Residential.
Outbreak Investigation
Understanding Epidemiology
Question #1 The IP is teaching nurses how to assess infection risks in patients. Depletion of what cell type provides the best indication of susceptibility.
Water Quality & micro-organisms
Infection Control Q and A APIC Greater NY Chapter 13 May 17, 2017 Beth Nivin BA MPH NYC DOHMH Communicable Disease Program
Lead and Copper Rule (LCR)
Outbreak Investigations
Table 4 Comparison of frequencies of Legionella pneumophila serogroup 1 urinary antigen results and antibody titer results among patients with Pontiac.
Copyright © 2017 American Academy of Pediatrics.
Hospital acquired infections
Outbreak Investigation and Environmental Sampling
MRWA Annual Meeting Bangor, Maine
Legionnaire’s Disease
Control of Legionella in hot and cold water systems
Legionnaires in Eastlake
World Health Organization
Legionnaires’ disease
Management of Outbreaks of Acute Respiratory Illness in Care Homes Out of Season and In Season Other areas: Where the home feels that their resident needs.
Legionnaire’s Disease
Presentation transcript:

Background of Disease 1a Legionnaires' disease acquired its name in July 1976 when an outbreak of pneumonia and other respiratory illnesses occurred among people attending a convention of the American Legion in Philadelphia On January 18, 1977 the causative agent was identified as a previously unknown bacterium, subsequently named Legionella Causative agent: Ubiquitous gram-negative bacillus that is largely aquatic but can thrive in areas other than lakes and streams Reference: Heymnann, D. L. (2008) Control of Communicable Diseases Manual (19 th ed.). Washington, DC: American Public Health Association.

Clinical Description 1b Legionalla can cause two distinct clinical diseases: Legionnaires’ disease – Febrile illness primarily associated with pneumonia – Incubation 2-10 days (most commonly 5–6 days) – Treatment usually necessary, can be severe Pontiac fever – Less severe form of disease, flu-like symptoms – Incubation 5-72 hrs (most commonly 24–48 hours) – Resolves without treatment in 2-5 days Reference: Heymann, D.L. (2008). Control of Communicable Diseases Manual (19 ed.). Washington, DC: American Public Health Association

Two distinct clinical diseases 1b Legionnaires’ disease – Febrile illness primarily associated with pneumonia – Incubation 2-10 days (most commonly 5–6 days) – Treatment usually necessary, can be severe Pontiac fever – Less severe form of disease, flu-like symptoms – Incubation 5-72 hrs (most commonly 24–48 hours) – Resolves without treatment in 2-5 days Reference: Heymann, D.L. (2008). Control of Communicable Diseases Manual (19 ed.). Washington, DC: American Public Health Association

Susceptibility 1c Risk Factor for Illness include: Increasing age (most cases are over 50) Males Smokers (increases risk 2-7 fold) Diabetes mellitus Chronic lung or renal disease Cancer (especially lung cancer or leukemia) Immunocompromised (increases risk 2-6 fold) Reference: Heymann, D.L. (2008). Control of Communicable Diseases Manual (19 ed.). Washington, DC: American Public Health Association

Reservoir and Transmission 1d Warm water (  F) supports the highest concentration of organisms Naturally Occurring Lakes Streams Man-made Whirlpools Showers Cooling towers Transmission thought to occur via inhalation of aerosolized water or aspiration Reference: Heymann, D.L. (2008). Control of Communicable Diseases Manual (19 ed.). Washington, DC: American Public Health Association

Public Health Response 2a Federal, state and local public health collaborative efforts identified and investigated a cluster of Legionella cases whose only commonality was staying at the same hotel in Fillmore, Utah Infection occurred June 2009-December 2009 First notification of cases came in November 2009 No cases were found from other facilities using the Fillmore water system Environmental Assessment Sample Collection & Laboratory Testing Remediation & Case Investigation

Local Environmental Health 2b Environmental Health Scientist visited the site and conducted an environmental assessment to determine possible reservoirs for Legionella This also served to guide sampling methods and remediation recommendations

Legal and Regulatory Concerns 2c The hotel owner worked well with public health for the assessment and remediation It was difficult to acquire a guest list for notifying patrons of exposure due to the influence of the hotels’ insurance adjustor Legal powers were required to obtain the guest list

Results and Remediation 2d Preliminary test result were positive and hotel was temporarily closed Remediation began immediately including: – Flushing water system – Superheating (over 138 o F) – Hyper-chlorination (Note: Some showerheads were ruined by corrosion during remediation) Maximum hot water temperatures at the end of the water system line was found to be low (90 o F) The temperature on the water heater thermostat had been reduced per guest complaint of water being too hot

Case Summary 3a =Hotel Stay CaseAgeSexResidencePool or Spa Use ShoweredAte in Hotel Restaurant Case 141MWashingtonYYY Case 272FUnited KingdomYYY Case 370FIdahoYYY Case 477MArizonaYYN Case 561MMontanaYYY

Final Laboratory Results 3b PositiveNegativeTotal Swab12 (46%)14 (54%)26 1L Bottles21 (70%)9 (30%)30 Total33 (59%)23 (41%)56 Two types of samples were obtained 1 L bottle samples taken from hot water sources Routine sample for the lab Swab samples from showerheads and faucets This was the first time the lab had processed swab samples Final results were positive for over half (59%) of the samples. Pool and spa samples were negative.

Case Finding 3c Once the guest list from the previous two weeks was secured, letters were sent alerting patrons of exposure Calls were fielded to answer questions and cross-jurisdictional collaboration ensued No other cases were found on the Fillmore water system

Wrap-up & Post Remediation 3d Post-remediation testing results were negative Follow-up testing continued monthly thereafter for 6 months (through May 2010) The hotel assumed all costs for follow-up testing Since results were negative, subsequent post- remediation testing were only done on six sites –The thermostat settings on the water heaters were increased –The hotel was advised to retrofit mixing valves in guest rooms All follow-up lab results were negative –The hotel was advised to perform periodic testing