PACS Structure Analysis1 PACS IBDR 27/28 Feb 2002 PACS Housing: Structure Analysis Dr. G. Wanderer CASE GmbH
PACS Structure Analysis2 PACS IBDR 27/28 Feb 2002 Loads Strength Analysis of Housing Parts Housing Pins and Bolts Notching of Sine- and Random Qualification Loads Suspension Analysis Brackets Pins and Bolts
PACS Structure Analysis3 PACS IBDR 27/28 Feb 2002 Dynamic and Static Loads Quasistatic: LC1 longitudinal 20g, lateral 2g LC2 lateral 14 g Sine Vibration longitudinal Hz 20g Hz 10g lateral Hz 14g Random Vibration Hz +6 dB/Oct Hz 0,05 g 2 /Hz Hz -6 dB/Oct
PACS Structure Analysis4 PACS IBDR 27/28 Feb 2002 Material The PACS Housing is build of AW 6061T6, Bolts and Pins are of Typ A4-70 (i. e. Steel AISI 316) Ref: MIL HDBK-5H, ESACRACK user´s manual
PACS Structure Analysis5 PACS IBDR 27/28 Feb 2002 Spectrometer Housing Spectrometer Housing is the highest loaded part except Suspension Stresses in Spectrometer Housing:
PACS Structure Analysis6 PACS IBDR 27/28 Feb 2002 Spectrometer Housing
PACS Structure Analysis7 PACS IBDR 27/28 Feb 2002 Pins And Bolts
PACS Structure Analysis8 PACS IBDR 27/28 Feb 2002 Notching of Vibration Loads Accelerometer- Positions with good correlation to I/F Forces
PACS Structure Analysis9 PACS IBDR 27/28 Feb 2002 Monitoring of I/F Loads I/F Loads for constant 1g Sine Reference Grid 13136
PACS Structure Analysis10 PACS IBDR 27/28 Feb 2002 Notch Procedure an accelerometer is located on the FPU at a place that the measured values correspond to the interface loads the notch calculation is based on the FE results scaled to the measured damping values for the major natural modes. random vibration: the equivalent force is calculated for each major natural mode by integrating the Force Power Spectral Density (PSD) around the mode The 4-sigma response is limited to the static load level for each major natural mode. The notch width shall be smaller than 1/3 octave around the natural frequency. The slope of the notch shall be as steep as possible (more than 24dB/Oct, typical 50dB/Oct). sine vibration: the output is limited to the calculated static interface force in the frequency range 50 to 100 Hz
PACS Structure Analysis11 PACS IBDR 27/28 Feb Axis Suspension
PACS Structure Analysis12 PACS IBDR 27/28 Feb 2002 Forces in Suspensions
PACS Structure Analysis13 PACS IBDR 27/28 Feb axis Suspension critical load path through pin of diameter 10mm (shear) = F/(2*A) = 7975N/(2*78mm 2 ) = 50,8N/mm 2 s = F*l/8W = 7975N*6mm / (8*98mm 3 ) = 60,9 N/mm 2 sMises = 107 MPa