Flow Measurement and Screens CE 547. Flow Meters Flow Meters: are devices used to measure the flow rate of a fluid Flow Meters: are devices used to measure.

Slides:



Advertisements
Similar presentations
Introduction to Long-Throated Flumes and Broad-Crested Weirs
Advertisements

Motion of particles trough fluids part 2
FLOW measurements.
CE 370 Filtration.
Chapter 2 Introduction to Heat Transfer
Liquids and Gasses Matter that “Flows”
Shell Momentum Balances
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Motion of particles trough fluids part 2
Example: Exercise (Pump)
Hydraulic Jump.
Elementary Fluid Dynamics: The Bernoulli Equation
Chapter 9 Solids and Fluids (c).
California State University, Chico
MECH 221 FLUID MECHANICS (Fall 06/07) Chapter 9: FLOWS IN PIPE
Chapter 15 Fluids.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Prelim 1 Review.
Flowmeters, Basic Hydraulics of Pipe Flow, Carrying Capacity and Continuity Equation Math for Water Technology MTH 082 Lecture 5 Hydraulics Chapter 7;
Fluid mechanics 3.1 – key points
Unit 3 - FLUID MECHANICS.
Electromagnetic Flowmeter Why use flow meters What is a magnetic flow meter – How do they work – How are the different from other meters Items that will.
Flow Measurement M. Shahini.
Flow Sensors.
CBE 150A – Transport Spring Semester 2014 Flow Measurement and Control.
Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013.
Fluid Mechanics 05.
In the analysis of a tilting pad thrust bearing, the following dimensions were measured: h1 = 10 mm, h2 = 5mm, L = 10 cm, B = 24 cm The shaft rotates.
Core Ag Engineering Principles – Session 1
Hydrostatic Pressure distribution in a static fluid and its effects on solid surfaces and on floating and submerged bodies. Fluid Statics M. Bahrami ENSC.
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
8. Permeability (Das, chapter 7)
Why do we need to treat wastewater ?
Chapter 7 continued Open Channel Flow
Fouling Factor: After a period of operation the heat transfer surfaces for a heat exchanger become coated with various deposits present in flow systems,
R. Field 10/29/2013 University of Florida PHY 2053Page 1 Ideal Fluids in Motion Bernoulli’s Equation: The Equation of Continuity: Steady Flow, Incompressible.
Hydrostatics: Fluids at Rest. applying Newtonian principles to fluids hydrostatics—the study of stationary fluids in which all forces are in equilibrium.
Measurement of flowing fluids
Unit: IV-Fluid Dynamic
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
CE 1501 CE 150 Fluid Mechanics G.A. Kallio Dept. of Mechanical Engineering, Mechatronic Engineering & Manufacturing Technology California State University,
Chapter 14 Fluids What is a Fluid? A fluid, in contrast to a solid, is a substance that can flow. Fluids conform to the boundaries of any container.
Reynolds Transport Theorem We need to relate time derivative of a property of a system to rate of change of that property within a certain region (C.V.)
TUesday, April 12, PHYS Dr. Andrew Brandt PHYS 1444 – Section 02 Review #2 Tuesday April 12, 2011 Dr. Andrew Brandt TEST IS THURSDAY 4/14.
Flow Measurement and Control
Flow measurement.
Seminar on, “ CALIBRATION TECHNIQUES FOR MAGMETERS” Presented By, Bhushan Patil Guided By, Prof. A.S. Kulkarni.
Chapter 14 Fluids.
Flow In Circular Pipes Objective ä To measure the pressure drop in the straight section of smooth, rough, and packed pipes as a function of flow rate.
Basic Hydraulics: Channels Analysis and design – I
CE 3354 Engineering Hydrology Lecture 21: Groundwater Hydrology Concepts – Part 1 1.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 15 Physics, 4 th Edition James S. Walker.
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
Statika Fluida Section 3. Fluid Dynamics Objectives Introduce concepts necessary to analyse fluids in motion Identify differences between Steady/unsteady.
Hydrology and Water Resources RG744 Institute of Space Technology November 13, 2015.
Flow Through A Small Orifice. Velocity can be predicted at the orifice using the Bernoulli equation between points 1 & 2. Notice that u 1 at the surface.
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
Energy Equation The expanded Bernoulli's equation
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
G.H.PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY
SUB:-FLUID MECHANICS TOPIC:-FLOW MEASUREMENT DEVICES SUBMITTED TO: KULDEEP SIR Government engineering college, valsad.
VENTURIMETER Department of Chemical Engineering
Open Channel Hydraulic
Mechanical Operation ( ) Prepared By, Hardev Jadav ( ) Sanjay k Prajapati ( ) Ravina Solanki ( )
1 Dept. of Agricultural & Biological Engineering University of Illinois TSM 363 Fluid Power Systems TSM 363 Fluid Power Systems Bernoulli’s Law and Applications.
60 1. What is the mass M in the system as given in the
ABE 223 ABE Principles – Machine systems Bernoulli’s Law Tony Grift
Physics 21.
3.2.2 Design Considerations
Flow Measurements.
Presentation transcript:

Flow Measurement and Screens CE 547

Flow Meters Flow Meters: are devices used to measure the flow rate of a fluid Flow Meters: are devices used to measure the flow rate of a fluid In Water, all types of flow meters can be used In Water, all types of flow meters can be used In Wastewater, the choice is critical due to solid content: In Wastewater, the choice is critical due to solid content: Solids can be removed Solids can be removed Flow has enough energy to be self-cleaning Flow has enough energy to be self-cleaning

Rectangular Weirs Fully-contracted weir

Suppressed weir: weir extends to the channel vertical sides

P = weir height H = head over the weir

The energy equation between (1) and (2) V = velocity (average) V = velocity (average) P = pressure P = pressure y = height above bottom of channel y = height above bottom of channel Z = height of bottom above a datum Z = height of bottom above a datum h l = head loss between (1) and (2) h l = head loss between (1) and (2) g = gravitational constant g = gravitational constant  = specific weight of water  = specific weight of water

In the figure: Z 1 = Z 2 = 0 V 2 >> V 1 P 1 = P 2 = atmospheric pressure If h l was neglected, then: y 1 = H + P y 2 = y c + P Substitute in the energy equation and change V 2 to V c (critical velocity)

Specific energy equation states that: Specific energy equation states that: The critical depth, y c, occurs at minimum specific energy The critical depth, y c, occurs at minimum specific energy Differentiate E with respect to y and equate to zero Differentiate E with respect to y and equate to zero Use ( Q = VA ) Use ( Q = VA ) Q = flow rate Q = flow rate V = velocity V = velocity A = cross-sectional area A = cross-sectional area

A/T = hydraulic depth, D A/T = hydraulic depth, D D is simply equals to y c D is simply equals to y c

Substitute for y c in: To get:

If L = length of the weir, then andUse

Remember h l and V 1 were neglected h l and V 1 were neglected y 2 was assumed to be (y c = P) y 2 was assumed to be (y c = P) L must be corrected depending upon whether the equation to be used for fully contracted or suppressed weirs L must be corrected depending upon whether the equation to be used for fully contracted or suppressed weirs

To make the equation more practical For fully contracted weirs

Example

To measure the flow rate of wastewater, a rectangular weir was used. The flow rate is 0.33 m 3 /s. Design the weir. The width of the rectangular channel to be connected to the weir is 2.0 m and the available head (H) is 0.2 m. Solution Use a fully suppressed weir and assume length, L = 2.0 m

Then, the dimensions of the weir are: L = 2.0 m L = 2.0 m P = 0.6 m P = 0.6 m

Triangular Weir (V-notch weir)

For low flow rates, triangular weirs are more accurate than the rectangular ones. The hydraulic profile in channels measured by triangular weirs is exactly similar to that measured by rectangular weirs K is obtained from the Figure 3.4 and multiplied by (8/15) as a correction factor.

Example

Solve previous example for v-notch weir if: Q = 0.33 m 3 /s Q = 0.33 m 3 /s Channel width = 2.0 m Channel width = 2.0 m H = 0.2 m H = 0.2 mSolution

From Figure 3.4 at H = 0.2 m Values of [ K(8/15) tan (  /2) ], in the table, is near 4.16 For  > 90 , K = 0.58 then, 4.16 = 0.58 (8/15) tan (  /2) tan (  /2) = so,  = 171   K K(8/15) tan (  /2) 90    

Trapezoidal Weirs Flow is contracted in trapezoidal weirs Flow is contracted in trapezoidal weirs The equation for suppressed weirs can be used: The equation for suppressed weirs can be used: In this case  = 28  In this case  = 28 

Venturi Meters Used to measure flow rate in pipes Used to measure flow rate in pipes

Example

Parshall Flumes

Can be used with Parshall Flumes Can be used with Parshall Flumes Replace L with W (width of throat) Replace L with W (width of throat) Replace H with H a (water surface elevation above flume floor level in the converging zone) Replace H with H a (water surface elevation above flume floor level in the converging zone)Then, K can be obtained from Figure 3.7. Also Table 3.1 shows standard Parshall flume dimensions.

Example

Miscellaneous Flow Meters Magnetic Flow Meter (measures flow by producing magnetic fields)

What is a Magnetic Flow Meter? A magnetic flow meter (magnetic flow meter) is a volumetric flow meter which does not have any moving parts and is ideal for wastewater applications or any dirty liquid which is conductive or water based. Magnetic flow meters will generally not work with hydrocarbons, distilled water and many non-aqueous solutions). Magnetic flow meters are also ideal for applications where low pressure drop and low maintenance are required.

Principle of Operation The operation of a magnetic flowmeter or mag meter is based upon Faraday's Law, which states that the voltage induced across any conductor as it moves at right angles through a magnetic field is proportional to the velocity of that conductor. Faraday's Formula: E is proportional to V  B  D where: E = The voltage generated in a conductor E = The voltage generated in a conductor V = The velocity of the conductor V = The velocity of the conductor B = The magnetic field strength B = The magnetic field strength D = The length of the conductor D = The length of the conductor

To apply this principle to flow measurement with a magnetic flowmeter, it is necessary first to state that the fluid being measured must be electrically conductive for the Faraday principle to apply. As applied to the design of magnetic flowmeters, Faraday's Law indicates that signal voltage (E) is dependent on the average liquid velocity (V) the magnetic field strength (B) and the length of the conductor (D) (which in this instance is the distance between the electrodes).In the case of wafer-style magnetic flowmeters, a magnetic field is established throughout the entire cross-section of the flow tube (Figure 1). If this magnetic field is considered as the measuring element of the magnetic flowmeter, it can be seen that the measuring element is exposed to the hydraulic conditions throughout the entire cross- section of the flowmeter. With insertion-style flowmeters, the magnetic field radiates outward from the inserted probe (Figure 2).

Magnetic Meter Selection The key questions which need to be answered before selecting a magnetic flowmeter are: Is the fluid conductive or water based? Is the fluid conductive or water based? Is the fluid or slurry abrasive? Is the fluid or slurry abrasive? Do you require an integral display or remote display? Do you require an integral display or remote display? Do you require an analog output? Do you require an analog output? What is the minimum and maximum flow rate for the flow meter? What is the minimum and maximum flow rate for the flow meter? What is the minimum and maximum process pressure? What is the minimum and maximum process pressure? What is the minimum and maximum process temperature? What is the minimum and maximum process temperature? Is the fluid chemically compatible with the flow meter wetted parts? Is the fluid chemically compatible with the flow meter wetted parts? What is the size of the pipe? What is the size of the pipe? Is the pipe always full? Is the pipe always full?

Turbine Flow Meters

Rotameters or Variable Area Flow Meters Variable area flow meters, or rotameters, use a tube and float to measure flow. As the fluid flows through the tube, the float rises. Equilibrium will be reached when pressure and the buoyancy of the float counterbalance gravity. The float's height in the tube is then used to reference a flow rate on a calibrated measurement reference.

Important Information on Rotameters The Variable-Area type flowmeter, or Rotameter, is one of the most economical and reliable of flow measurement instruments. In various configurations it can be designed to withstand high pres sures, corrosive fluids, high temperatures, and is completely independent of factors influencing electronic meters. The Variable-Area type flowmeter, or Rotameter, is one of the most economical and reliable of flow measurement instruments. In various configurations it can be designed to withstand high pres sures, corrosive fluids, high temperatures, and is completely independent of factors influencing electronic meters. They can be calibrated to measure nearly any gas or liquid, because their principles of operation are simple and well understood. The flow indication is obtained from a balance of the fluid forces underneath the float with gravity. They can be calibrated to measure nearly any gas or liquid, because their principles of operation are simple and well understood. The flow indication is obtained from a balance of the fluid forces underneath the float with gravity.

Important Information on Rotameters This is done using a uniformly tapered tube, a float whose diameter is nearly identical to the tube ID at the inlet, and a scale to correlate float height. The flow tube is traditionally placed in a vertical position and fluid enters from the bottom, forcing the float up in the tube until a sufficient annular opening exists between the float and tube to allow the total volume of fluid to flow past the float. At this point the float is in an equilibrium position and its height is proportional to the flow rate. This is done using a uniformly tapered tube, a float whose diameter is nearly identical to the tube ID at the inlet, and a scale to correlate float height. The flow tube is traditionally placed in a vertical position and fluid enters from the bottom, forcing the float up in the tube until a sufficient annular opening exists between the float and tube to allow the total volume of fluid to flow past the float. At this point the float is in an equilibrium position and its height is proportional to the flow rate.

Important Information on Rotameters With this in mind, many simple factors influencing rotameter performance are easily understood. For example, increasing the density and weight of the float will require a higher flow rate to force the ball up to any height in the tube. In addition, it is easy to see that any changes in the fluid caused by temperature or pressure will affect the float's position. This is particularly true for gases which are compressible, and are therefore, greatly affected by operating pressures. Studies over the years have resulted in many With this in mind, many simple factors influencing rotameter performance are easily understood. For example, increasing the density and weight of the float will require a higher flow rate to force the ball up to any height in the tube. In addition, it is easy to see that any changes in the fluid caused by temperature or pressure will affect the float's position. This is particularly true for gases which are compressible, and are therefore, greatly affected by operating pressures. Studies over the years have resulted in many

Screening

Is a unit operation that separates materials into different sizes using screens Bar Racks or Bar Screen (Fig 5.1) Are composed of large bars spaced at 25 – 80 mm apart Are composed of large bars spaced at 25 – 80 mm apart Used to exclude large particles Used to exclude large particles Used in water intakes at shores and wastewater treatment plants Used in water intakes at shores and wastewater treatment plants Hand cleaned or mechanically cleaned Hand cleaned or mechanically cleaned

Traveling Screens (Fig 5.2) Used to remove smaller particles in water treatment plants (following bar screens) such as leaves, small fish and other materials that pass the bar screen.

Micro-strainer (Fig 5.3) Made of very fine fabric or screen wound around a drum Made of very fine fabric or screen wound around a drum 75% of the drum is submerged 75% of the drum is submerged Rotates at 5 to 45 rpm Rotates at 5 to 45 rpm Influent is introduced from the underside of the drum and exits into the outside Influent is introduced from the underside of the drum and exits into the outside Strained materials (solids) are retained inside of the drum and removed by jets of water through a trough inside the drum Strained materials (solids) are retained inside of the drum and removed by jets of water through a trough inside the drum Flow of influent is sometimes from the outside to the inside Flow of influent is sometimes from the outside to the inside Used to remove high concentrations of algae (effluent from stabilization ponds) or treatment of effluents from biological treatment processes Used to remove high concentrations of algae (effluent from stabilization ponds) or treatment of effluents from biological treatment processes The pore size of micro-strainers range between 20 – 60  m The pore size of micro-strainers range between 20 – 60  m Material used in micro-strainers include stainless steel and polyester Material used in micro-strainers include stainless steel and polyester

Head Loss in Bar Racks Apply Bernoulli equation (Fig 5.2) P = pressure P = pressure V = velocity (V1 = approach velocity) V = velocity (V1 = approach velocity) h = elevation head h = elevation head g = acceleration due to gravity g = acceleration due to gravity

Approach velocity should be maintained at self- cleaning velocity (  0.76 m/s) Since, P 1 = P 2 = atmospheric pressure Then, From continuity equation

Bernoulli equation assumes frictionless flow, to correct for this, a coefficient of discharge must be added to the equation, thus: Solve for  h C d is determined experimentally or a value of 0.84 may be used. As the screen clogs, the value of A 2 will decrease.

Head Loss in Micro-strainers The flow turns at right angle (90  ) as it enters the openings of the micro-strainer cloth. Therefore, the approach velocity (V 1 ) is equal to ZERO. Thus: Similarly, C d can be determined experimentally or a value of 0.60 can be used. The above equation can be applied to screens where the approach velocity is negligible.

Design Parameters and Criteria for Bar Screens ParameterMechanically Cleaned Manually Cleaned Bar Size  Width, mm  Thickness, mm 5 – – 80 5 – – 80 Bar Clear Spacing, mm20 – 5015 – 80 Slope from Vertical, degree30 – 450 – 30 Approach Velocity, m/s0.3 – – 1.0