Laboratory Fume Hoods In accordance with Title 8 CCR Section 5154.1, Ventilation Requirements for Laboratory-Type Hood Operations. California State University.

Slides:



Advertisements
Similar presentations
COSHH ASSESSMENT TRAINING Essential Elements of a COSHH Form.
Advertisements

Emergency Preparedness and Response
East Carolina University Compressed Gas Safety Training Program
Airflow and BSC Biosafety and Biosecurity Awareness Training
Environmental Health and Safety Oklahoma State University Hazard Communication Your “Right to Know”
Hazardous Substances. Employer’s Responsibility Every employer has a duty to ensure that their employees and others are not exposed to risks to their.
Approved by Chemistry Department Faculty January 13, 2005 Upon the recommendation of C. A. S. H. and Department Safety Committee UNC Chemistry Department.
Hazard Communication 29 CFR Compliance Training Presentation.
What we do and why we do it. Know how to inspect an SCBA bottle for damage prior to fill Know how to use the compressor Know how to document problems.
Introduction Most accidents are caused by the uncontrolled release of hazardous energy. Many of these accidents can be prevented by proper lock-out/tag-out.
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
Laboratory Safety-Fume Hoods 29 CFR Laboratory Safety Standard.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
1 FUME HOOD SAFETY Environmental Energy Technologies Division Safety Topic July 12, 2012.
Confined Space Safety An overview of the hazards and regulatory requirements associated with confined space work.
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
External Operations Experience Update: Laboratory Safety Department of Energy Operating Experience Work Group November 18, 2014 Larry Stirling, Office.
Spray Finishing Operations/Spray Booth March 9, 2009.
Means of Egress and Fire Protection. 2 Objectives Understand Alarms and Warning Devices Know the location of Exits and Exit Routes Understand the RACE.
Laboratory Accumulation of Hazardous Waste Presented By: Richard Smith Environmental Health & Safety Administrative Office Research and Extension Centers.
LOCKOUT/TAGOUT.
LAUSD INJURY AND ILLNESS PREVENTION PROGRAM FOR SUPERVISORS AND EMPLOYEES As required by California Code of Regulations, Title 8, Section 3203.
Controlling Hazardous Energy
Control of Substances Hazardous to Health Regulations 2002 (COSHH)
Developing a Chemical Risk Management Program
OSHA Long Term Care Worker Protection Program.  Recognize the purpose of the hazard communication standard.  Describe the components of a hazard communication.
Safety Training Presentations
Industrial Hygiene Approach to EHS Issues in Schools: Assessment, Controls, Design, and Prevention Lorraine M. Conroy, ScD, CIH Associate Professor University.
West Virginia University Laboratory Training Module 1. OSHA Laboratory Standard.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Confined Space Safety Training Presentations
NC A&T STATE UNIVERSITY
Respiratory Protection
HAZARD COMMUNICATION For Non-Employees Who Routinely Work With Chemicals.
Means of Egress and Fire Protection
HAZARDOUS COMMUNICATION - MSDS General Chemical Safety Chemical Storage Container Labeling Emergencies MSDS - Chemical User Information.
Chinook’s Edge School Division No. 73 General Safety Orientation.
Preventing Slips & Trips at Work
Risk Management Services Confined Space Entry Basics.
MSHA Increased Emphasis on Improved Implementation of Surveys at MNM Mines.
Environmental Health and Safety Oklahoma State University Hazard Communications Your “Right to Know”
Hazard Communication Presentation Presented by: Western Assurance Corp Desert Utility & Paving, LLC and Century Club Construction, LLC Design © 2005, 2012.
Laboratory Laboratory (29 CFR ) (29 CFR ) Standard Hygiene Hygiene.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Managing Hazardous Chemical Waste. What is Hazardous Waste EPA Definition: A material is a hazardous waste if due to its quantity, concentration, physical,
Exit Routes and Fire Protection
National Fit Testing Services OSHA CFR Respiratory Protection Program Presented by National Fit Testing Services Linda Lane, RRT/President.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
A Health and safety law training programme for employers This programme has been set up to guide employers on some of the basic H&S legislation in the.
04-25 Right to Know Right to Know  General  The purpose of this guideline is to insure that the Brunswick Fire Company No. 1 provides a safe.
Flammable Liquids Directorate of Training and Education
Emergency Response For the Hazardous Waste Worker.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Lock Out Tag Out (LOTO).
Cross Connection Survey Training
Lock Out & Tag Out.
Respiratory Protection Program
(Modified from University Of South Carolina)
Fire Extinguisher Inspections.
CHME 590/690 Jett Hall Lab Researcher Commissioning
PPE Program 29 CFR OSHA requirement for this company to have a Personal Protective Equipment Program to protect employees from exposure to.
East Carolina University Compressed Gas Safety Training Program
Fume Hood – Proper Handling of Chemicals / Proper Functioning
Confined Space (Permit-required)
EMPLOYEE “RIGHT –TO –KNOW” LAW
Control of Hazardous Energy
LAUSD INJURY AND ILLNESS PREVENTION PROGRAM FOR SUPERVISORS AND EMPLOYEES As required by California Code of Regulations, Title 8, Section 3203.
California State University Fresno
Presentation transcript:

Laboratory Fume Hoods In accordance with Title 8 CCR Section , Ventilation Requirements for Laboratory-Type Hood Operations. California State University Fresno CSU Fresno, Environmental Health & Safety (559)

Introduction Purpose of a Laboratory Fume Hood Laboratory Fume Hoods help prevent exposure to fumes, vapors and particulate matter from hazardous substances.

Introduction Functions of a Laboratory Fume Hood Fume hoods draw airflow inward, away from the worker.

Operator Qualifications Training Requirements To operate a fume hood, one must be trained to:  Use the hood properly and safely.  Determine last performance test, and if requirements are met.  Understand the general hood purpose, airflow characteristics, and potential for turbulent airflow and escape of hazardous substances from the hood.  Know where the quantitative airflow monitor or alarm system is located on the hood and how it is used to indicate an inward airflow during hood operation 8 CCR (f)(3)

Pre-Use Inspection Overview Check for last inspection date by EHS.  Postings or signs should be present when a fume hood is out of order and EHS is aware. If you suspect your hood is not working contact EHS immediately at Check quantitative airflow monitoring device to ensure hood is working properly. Use qualitative methods to ensure air is flowing in the proper direction.

Pre-Use Inspection Determining last inspection Each fume hood must have inspection record indicating:  Last date of inspection.  Initials of the last inspector of the device.  Whether the device passed or failed inspection. This data sheet is normally attached to the fume hood. Units that fail an inspection are tagged with a “Do Not Use” sign with a date the unit was taken out of service. Units must be re-inspected:  Annually.  After any repair.  Following any addition of large equipment to the unit.

Pre-Use Inspection Quantitative Monitoring Devices A hood user must quantitatively identify whether their fume hood is working properly. The method must measure an exact or approximate rate of inward airflow. Acceptable devices to determine quantitative airflow include:  Inclined Manometers  Diaphragm Pressure Gauges  Vane Gauges  An Airflow Alarm System is also acceptable, granted that the “system provides an audible or visual alarm when the airflow decreases to less than 80% of the airflow required by subsection” 8 CCR (e)(3)(A) All values indicated on the device should be no less then those indicated on the certified “safe level” indicated by the label on the fume hood.

Pre-Use Inspection Examples of Quantitative Monitoring Devices Vaneometer  Rare on campus, but acceptable. Inclined Manometer  This device is very common on campus. Diaphragm Pressure Gauge  Rare on campus, but acceptable.

Pre-Use Inspection Examples of Quantitative Monitoring Devices Fume Hood Alarm Device Alerts the user if there is inadequate inward airflow  Visually  Audibly These units should have a visual aid of some sort indicating that the unit is functioning and is safe to use.

Pre-Use Inspection Examples of Quantitative Monitoring Devices If you do not have a working qualitative method to assess if the fume hood is functioning properly, contact EHS at

Pre-Use Inspection Qualitative Inspection Methods Examples of Qualitative Devices include:  Kimwipes / Delicate Wipes  Tape  Mylar Strips The device used must demonstrate airflow is flowing inward.

Pre-Use Inspection Qualitative Inspection Methods The material used (kimwipe, mylar or tape) should be pulled in by the fume hood to indicate there is inward airflow. The material must be tested in multiple areas where the hood is open. If you are having trouble or do not note the inward movement of air, make sure you have remembered to turn the unit on.

Using the Fume Hood Work Practices The sash of the fume hood may be raised completely during usage, unless marked otherwise.  If marked the hood shall be opened no further then the safe operating level, indicated by the arrows, when in use.

Using the Fume Hood Work Practices Store non-essential chemicals and other equipment outside of the fume hood. Keep the hood free from obstruction of large equipment whenever possible. Storage of hazardous waste containers not related to the wastes being generated within the hood is not advised.  Incompatible wastes are required to be separated and closed during storage, except when it is necessary to add waste Do not put your face inside the fume hood when hazardous substances are present.  Always keep your face and body outside the unit when in use.

Have Concerns? When should you contact EHS with any concerns? Annual Inspection  If you note that an inspection was not completed within one year. Maintenance Repairs Addition of Large Equipment Newly Installed Hoods You suspect your fume hood is not protecting you adequately for any reason.

Training Completion Acknowledgement form Please either print out a copy of this slide or request a hard copy from your Department Safety Coordinator or Supervisor. Please sign/date in the spaces provided, and then forward it to your Department Safety Coordinator or Supervisor. I have read the slides presented in the Laboratory Fume Hoods Power Point presentation and have reviewed the associated department-specific plans. Name (Print)_________________________________________________ Signature ___________________________________________________ Department _________________________________________________ Date _____________________________

Contacting Campus Environmental Health and Safety For questions and concerns, please call California State University Fresno Environmental Health and Safety Department at: (559)