Degradation of an Organic Overlayer Model of a Dental Composite Analyzed by Liquid Chromatography Mass Spectrometry Peter Koin, 2 Ayben Kilislioglu, 4.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
GC & LC.
Food Analysis Lecture 23 (4/19/2005) HPLC (2) and Gas Chromatography (1) Qingrong Huang Department of Food Science Read Material: Chapter 29, page 479.
Dr.HINA ADNAN.  It is a tooth colored restorative material that is composed of organic resin matrix and inorganic filler particles dispersed in it.
Lecture 9 Yuri Kazakevich Seton Hall University
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Results Initial chromatographic conditions [Figure 2a caption] for the separation of the degradation products of aspirin were problematic due to the long.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
Based on McMurry’s Organic Chemistry, 6th edition ©2003 Ronald Kluger
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite Separation 3.Metabolite detection (with or without separation) 4.Data analysis.
Molecular Mass Spectrometry
LC-MS Lecture 7.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 21 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chapter 6 - Chromatography
High Performance Liquid Chromatography
ADVANCED BIO-FRIENDLY POLYMERS Igor Lacík Gel permeation chromatography – a tool for determination of molar mass of polymers.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
High Performance Liquid Chromatography Instrumentation.
Peak-purity by LC-MS and LC-DAD Knut Dyrstad Erlend Hvattum Sharon Jara Arnvid Lie.
DENTURE LINING MATERIALS
Using LCMS to investigate fatty acid oxidation in cyanobacteria
Volume contraction in photocured dental resins : the shrinkage - conversion relationship revisited Dewaele M.- Truffier D.- Leloup G.- Devaux J. Université.
Extraction and HPLC of Hypericin Courtney Arnott Intermediate Lab Fall 2001.
High Performance Liquid Chromatography High Performance Liquid Chromatography Presented by- MOHSIN NISAR KHAN MOHSIN NISAR KHAN.
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Best Broken into four categories
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
High Performance Liquid Chromatography
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
INFLUENCE OF THE CHEMICAL COMPOSITION UPON THE PROPERTIES OF SOME EXPERIMENTAL DENTAL INDIRECT RESIN COMPOSITES C. Prejmerean, M. Moldovan, L. Vezsenyi,
Why HPLC? Almost universal applicability Remarkable precision Highly commercially available (competition)
Determination of metformin in urine (by Liquid Chromatography LC)
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
Laboratory class on next Wednesday
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Synthesis and characterization of norfloxacin biomonomer Shengxiong DONG 1, 2, 3 ;Qiaoping CHEN 1 ;Hongfang XIE 1 ;Jianhua HUANG 1, 2, 3 ; 1. Department.
Chromatography- TLC & HPLC
High Performance Liquid Chromatography HPLC
HPLC Equipment : Detectors
Name of the commercial Composite Degree of conversion (%)
Approx. Filler conc.(wt%)
Best Broken into four categories
© The Author(s) Published by Science and Education Publishing.
Pure Carrier Gas Grades (subjective)
Satish Pradhan Dnyanasadhana College, Thane (W)
High Performance Liquid Chromatography
Composite Restorative Material part I
Chromatography Daheeya Alenazi.
High Performance Liquid Chromatography
High Performance Liquid Chromatography (H. P. L. C. ) dr. Sham b
Liquid Chromatography - Method Development and Validation
High-Performance Liquid Chromatography
Transferring LC-UV to LC-MS.
High-Performance Liquid Chromatography
Presentation transcript:

Degradation of an Organic Overlayer Model of a Dental Composite Analyzed by Liquid Chromatography Mass Spectrometry Peter Koin, 2 Ayben Kilislioglu, 4 Manshui Zhou, 1 James L. Drummond, 3 and Luke Hanley 1,* University of Illinois at Chicago, Departments of 1 Chemistry, 2 Bioengineering, and 3 Restorative Dentistry, m/c 111, Chicago, IL USA 4 Istanbul University, Department of Chemistry, Avcilar 34320, Istanbul, Turkey Motivation Goals Degradation Study Purpose Dental Composites consist of a polymerizable resin matrix, reinforcing glass filler particles, and a silane coupler. One of the most used resin monomer of dental composites is Bisphenol A glycerolate dimethacrylate (BisGMA) Composites undergo property changes due to oral environment Environment can weaken materials and reduce restoration longevity Can release compounds into tissues and accumulate Study materials that can leach out of composite New System of Analysis Degradation studies of commercial composites too complex [1] Monolayer system to understand degradation and erosion [2] Monolayer System Dental composites made of resin matrix, glass particle filler, and a silane coupling agent Resin matrix: Bisphenol A glycerolate dimethacrylate (BisGMA) Glass filler: Nanoporous silicon chip Silane coupling agent: MPS- 3- (trimethoxysilyl) propyl methacrylate Glass particles used to reduce overall polymer shrinkage Silane coupler covalently links resin to glass filler: improves mechanical properties and increases hydrolytic stability due to hydrophobic nature Dental Composite Model Experimental Methods Conclusions Funded by National Institute of Dental and Craniofacial Research, DE [1] MS Zhou, JL. Drummond, L Hanley. Dental Materials. 21 (2005) : [2] MS. Zhou, CP. Wu, PD. Edirisinghe, JL. Drummond, L. Hanley. Journal of Biomedical Materials Research A. 76 (2006). Results Study degradation of Dental Composite Model after aging in water for 2 weeks Qualitative analysis to find degradation peaks using MS Fragmenter software and MS-MS analysis Silicon Wafer (N-Type 100) 24 (wt)% HF/EtOH 20 mA/cm 2, 5 min Nanoporous silicon 31.6% H 2 O 2 50°C, 1hr Porous SiO 2 Surface (Stored in 1N HNO 3 Solution) Porous SiO2 2 (wt) % MPS/Toluene 60°C, 96hrs Wash Toluene Baking 80°C, 12hrs MPS-Silanized Substrate 2.0 mg/ml BisGMA/EtOH Initiator Solution Cure, UV light 20 min Polymerized methacryloyl BisGMA Overlayer Instrumentation LCMS –Finnigan Mat LcQ HPLC –SpectraSYSTEMS SCM 1000 vacuum membrane degasser –P4000 gradient elution pump –AS 3000 autosampler –UV 2000 dual-wave length detector Data Analysis Software ACD Labs (Toronto, Ont., Canada) ACD MS Manager to analyze and process data ACD MS Fragmenter- Program generates fragments and structures by using standard fragmentation rules HPLC Conditions Mobile Phase: Gradient of MeOH/H20 Flow Rate: 0.3 ml/min Temperature: Room Temperature, 25°C UV Wavelength: 250 nm Column: Reverse Phase Water Symmetry C μm, 3.0 mm diameter, 150 mm length Injection volume: 10 μ L Standards Analysis to find retention time Standards Resin Material: BisGMA Silane Coupler: MPS- not run because of adverse effect of MPS with columns Photoinitiator solution: triethanolamine, vinyl pyrrolidinone, and eosin Y Glass Filler: nanoporous silicon chip, prepared similar to DIOS chips –Possible Degradation Products: bisphenol A, methacrylic acid Aged Monolayer Samples 3 nanoporous silicon chips per sample 2 weeks aged in de-ionized water Also aged blank nanoporous silicon chip with no BisGMA or methacryloyl layer to determine nanoporous silicon background TIC of Extract from Methacryoyl BisGMA monolayer on nanoporous silicon aged for 2 weeks in DI water. Electrospray ion trap mass spectra of BISGMA from TIC at 16.0 min with a main peak of m/z 530. M+NH4 MSMS of BisGMA, m/z 530. Spectra shows the M+NH 4 peak at m/z 530, M+H peak at m/z 513, M-H 2 0+H at m/z 495, and main degradation products at m/z 191, 277, and 427 Retention Time (min) m/zName # of runs Structure Method of ID peak Structure (# of runs) / BisGMA26 MS of Standard- Obvious / (BisGMA)”25Unknown StructureMS/MS (14) / (BisGMA)’15Unknown StructureMS/MS (4) / (BisGMA)”’12Unknown StructureMS/MS (8) / BisGMA-MA 15 MS Fragmenter Software, MSMS (4) / BisGMA- 2MA 5 MS Fragmenter Software Unknown Structure Electrospray ion trap mass spectra of (BisGMA)’ Polymer at 18.6 min, which is a BisGMA polymer derivative with a m/z difference of 44 between peaks. Unknown Structure Electrospray ion trap mass spectra of (BisGMA)” Polymer at 20.4 min. Unknown Structure Electrospray ion trap mass spectra of (BisGMA)”’ Polymer at 21.8 min, which is a BisGMA polymer derivative with a m/z difference of 44 between peaks. CH 3 CH 3 O O OH O OH CH 3 OH CH 2 O +H +H-H 2 O Electrospray ion trap mass spectra from TIC at RT= 11.5 min with a main peak at m/z 462 that corresponds to a BisGMA degradation product Electrospray ion trap mass spectra of BisGMA degradation product with a m/z 363, at a retention time of 23.8 min. TIC of Pure BisGMA run through HPLC, no aging. Unreacted BisGMA strongly adsorbs to surface of nanoporous silicon and slowly leaches out Aging also causes hydrolysis of ester bonds and causes degradation products of BisGMA to appear Oligomer peaks with unknown structures also appear after aging BisGMA-methacryloyl monolayer BisGMA-MA m/z 462 BisGMA-2MA m/z 363 A B Reaction of BisGMA-methacryloyl monolayer in the presence of water. Hydrolysis of ester bonds causes degradation products of BisGMA to appear. Hydrolysis reactions can also occur at black arrows, but do not show up in sample data