Introduction to the Measurement of Non- ionizing Radiation CONSULTORA FEDERAL DE COMUNICACIONES (CFC) – ARGENTINA – – ARGENTINA – Alfredo Debattista 19.

Slides:



Advertisements
Similar presentations
Ministerio de Transportes y Comunicaciones Legislative Treatment in Peru of Non- Ionizing Radiation from Telecommunication Dr. Carla P. Sosa Vela.
Advertisements

CONFIDENTIAL R.S.I. CORPORATION University Based Safety Training Personal Monitors.
IN-SITU MEASUREMENTS OF ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELDS IN THE ENVIRONMENT Branislav Vulević, Čedomir Belić, Trajan Stalevski Public Company.
ITU-T Technical Session on EMF
Nairobi, Kenya, 26 – 27July 2010 Role of ITU-T & ITU-R Ahmed ZEDDAM Ahmed ZEDDAM, ITU-T SG5 Chair France Telecom Orange ITU-T Workshop on Delivering Good.
Quito, Ecuador, 14 August 2013 Assessing EMF Levels Guidance and Recommendations Mike Wood EME Management Education & Compliance Telstra ITU Workshop on.
International Telecommunication Union Seminar on Impact of Electromagnetic Field Emissions Kampala, Uganda, 3-5 September 2003 ITU-T activities in EMF.
Paolo Gemma, Senior Expert, Huawei
Chapter 22 Electromagnetic Waves. Units of Chapter 22 Changing Electric Fields Produce Magnetic Fields; Maxwell’s Equations Production of Electromagnetic.
Safety Assessment for Electric Utility Workers Exposed to ELF-EMF: Literature Review Tarek K Abdel-Galil Ibrahim O Habiballah 27 Nov
Current research work and plans Zbigniew M. Jóskiewicz Wroclaw University of Technology Institute of Telecommunication and Acoustics Wybrzeże Wyspiańskiego.
Electromagnetic Wave Theory
Field Strength Measurements Relative to ARRL Concerns Regarding BPL October 16, 2003 Steve Martin Technical Research Branch Federal Communications Commission.
Overview of ITU-T's activities on EMF
STANDARDS AND COMPLIANCE TESTING P. Bernardi Department of Electronic Engineering - University of Rome "La Sapienza"
Lima, Peru, 10 December 2013 Overview of ITU-T Activities on Human Exposure to Electromagnetic Fields (EMFs) Mike Wood, General Manager, Telstra EME Management.
Cristina Bueti Advisor, ITU-T Study Group 5
GSC: Standardization Advancing Global Communications Resolution GSC-10/05: (GRSC) Facilitating Liaison in Relation to Measurement Methodologies for Assessing.
Radio Interference Calculations
Radio Frequency Safety. Purpose Provide: Basic Technical Understanding Overview of FCC Regulations and Compliance Issues Hazard Recognition Skills Awareness.
Exposure to risks arising from electromagnetic fields Chris Marshman York EMC Services Ltd University of York.
Telecommunications Issues for Wind Power Facilities Interdepartment Radio Advisory Committee Presentation June 14, 2005.
EMI in an RQZ: the need for buffer zones Carol Wilson, CSIRO Research Consultant RFI2010, Groningen.
1 INTERNATIONAL TELECOMMUNICATION UNION Telecommunications Development Bureau (BDT) REGIONAL OFFICE FOR AFRICA EMF ENVIRONMENTAL CHARACTERIZATION OVERVIEW.
RF Safety Measurements IOSH meeting Emley 4 th July
RESULTS AND CONCLUSION
1 EMF ASSESSMENT BY MEASUREMENT (IVORIAN CASE ) GUY-MICHEL KOUAKOU Head of standardization service VICE-CHAIR OF STUDY GROUP 5.
Nairobi, Kenya, 26 – 27July 2010 Revue on RF Safety Reference Levels and Measurement protocols Christian BLANCHARD CEO Planet Network International ITU-T.
URSI Session "Large Scale Science Projects: Europe – Africa Connects" The 11 th IEEE AFRICON conference, September 9 – 12, 2013, Mauritius
15 Feb 2001Property of R. Struzak1 Antenna Fundamentals (1) Prof. R. Struzak School on Digital and Multimedia Communications.
NON-IONIZING RADIATION MEASUREMENTS IN VOJVODINA Istvan Bikit, Dusan Mrda,Nebojsa Krstic, Nikola Jovancevic, Mile Ugarcina, Slavko Todorovic Department.
INICTEL1 INTER-AMERICAN TELECOMMUNICATION COMMISSION WORKSHOP ON “TECHNICAL AND REGULATORY ASPECTS RELATED TO THE EFFECTS OF ELECTROMAGNETIC NON-IONIZING.
Wireless Technology: A review of the Science. How Do we Prove Causation? 1.Temporal Relationship 2.Strength of the Association 3.Dose-Response relationship.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
Radiation Safety Plan Recommended by OSHA Elements of Plan  Site Specific Issues  Personnel Training  Safety Procedures  Definition of Controlled and.
Millimeter Wave Regulation IEEE EMC – DC/No. VA Mitchell Lazarus | January 31, 2012 Millimeter Wave Regulation IEEE EMC.
International Telecommunication Union Committed to connecting the world 4 th ITU Green Standards Week Cristina Bueti Adviser of ITU-T Study Group 5 With.
Characterizing evidence in EMF risk assessment, Berlin, 4-5 May 2006 The WHO International EMF Project Dr E. van Deventer Radiation and Environmental Health.
EMF STANDARDIZATION IN ITU
Committed to connecting the world With ICTs everywhere, how safe is EMF? Guy-Michel KOUAKOU Chairman of Study Group 5 Regional Group for Africa (SG5 RG-AFR)
COMISIÓN NACIONAL DE COMUNICACIONES NON-IONIZING RADIATION THE SITUATION IN ARGENTINA Ceferino Namuncurá Speaker.
1 25 November 2013 RF Safety Standards Prof Ely Levine AFEKA College of Engineering.
Presented by N.W. Pieterse GAUTENG BRANCH WORKSHOP 25 NOVEMBER 2015 ELECTROMAGNETIC FIELD RADIATION IN THE WORKPLACE.
Gaborone, Botswana, July 2011 EMF Measurement Protocol and equipments (part II) Country Experience : France Jean-Benoît Agnani Engineer Agence nationale.
Committed to Connecting the World March 2011 Geneva, March 2011 Presentation of the Recommendation ITU-T K 100: Presentation of the Recommendation.
IEEE /r0 Submission July 2004 Hiroyo Ogawa, NICT Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs) Submission.
ITU Symposium on ICT, Environment and Climate Change (Kuala Lumpur, Malaysia, 21 April 2016) MEASUREMENTS AND CALCULATIONS OF EMF Fryderyk Lewicki, ITU-T.
Overview of International guidelines concerning Human exposure to RF radiation From GSM Base Stations Eng. Nasser Al-Nasser Communications and Information.
RF Exposure and Limits A Basic Overview. Background Recent developments in the electronics industry have led to the widespread use of radio frequency.
M O N T E N E G R O Negotiating Team for the Accession of Montenegro to the European Union Working Group for Chapter 28 – Consumer and Health Protection.
MULTI-BAND AREA MONITOR SENSOR IN INFORMATION NETWORK FOR ELECTROMAGNETIC FIELDS MONITORING Miodrag MILUTINOV Nikola DJURIĆ Bogdan VUKOBRATOVIĆ University.
A Global Approach to EMF Management and Standards Mike Wood Vice Chairman, ITU-T SG5, WP2 11th Symposium on ICT, Environment and Climate Change 21 April.
NIR Safety Awareness Module 3: NIR Standards. NIR Safety Awareness Module 3: NIR Standards.
Finding the Poynting’s Theorem in a Health Center in San Pablo (peru)
Assessing EMF Levels Guidance and Recommendations
Non-Ionizing Radiation Safety Awareness
Radio Coverage Prediction in Picocell Indoor Networks
EMF ASSESSMENT BY MESEAREMENTS AND CALCULATION (IVORIAN CASE)
Concept of Power Control in Cellular Communication Channels
ITU Workshop on “With Information and Communication Technologies (ICTs) everywhere - how safe is EMF in Latin America ?” (Lima, Peru, 10 December 2013)
Overview of ITU-T's activities on EMF
GSM Base Station Antennas
Cristina Bueti Advisor, ITU-T Study Group 5
4th ITU Green Standards Week
GSC: Standardization Advancing Global Communications
Submission Title: [Regulatory Update]
GSC: Standardization Advancing Global Communications
4th ITU Green Standards Week
Cristina Bueti Advisor, ITU-T Study Group 5
GSC: Standardization Advancing Global Communications
Presentation transcript:

Introduction to the Measurement of Non- ionizing Radiation CONSULTORA FEDERAL DE COMUNICACIONES (CFC) – ARGENTINA – – ARGENTINA – Alfredo Debattista 19 June 2006 – Lima, Peru

Basic information about CFC Created only recently but making a major contribution Its members contribute the value added: Public and private telecommunications sector Technical and management profiles Great experience vis-à-vis the Radio Spectrum and Non-ionizing Radiation Focuses on providing comprehensive advisory services, not only for technical matters but also with regard to regulatory issues and procedures, for government agencies and private companies

What do we offer? Comprehensive advisory services with regard to Non-ionizing Radiation (NIR) Methodology for measuring NIR Consciousness raising and mitigation of the possible effects of NIR Development of regulations for municipal districts and government bodies Development of protocols for measuring N IR, based on international recommendations and standards

Case Study: Situation in Argentina Concerns of the population and users of communications equipment (Mobile Telephony) “Activity” of municipal districts and provincial governments Political will vs. practical implementation Risk of overlapping regulation Examples: Río Gallegos (Santa Cruz) San Fernando de Catamarca Rosario (Santa Fé) Ciudad Autónoma de Buenos Aires Province of Buenos Aires

Argentina’s Regulatory Framework Follows international parameters (ICNIRP, WHO, IEEE, FCC) Resolution Nº 202/1995 – National Ministry of Health and Social Action Resolution Nº 530/2000 – National Communications Secretariat Resolution Nº 269/2002 – National Communications Committee (CNC) [Withdrawn] Resolution Nº 117/2003 – CNC [Withdrawn] Resolution Nº 3690/2004 – CNC [In Force] Note: Communications Secretariat is the Implementing Agency CNC is the Oversight Body

Standardizing NIR concepts NON-IONIZING RADIATION (NIR): Radiation across the electromagnetic spectrum that does not have sufficient energy to ionize matter ELECTRIC FIELD STRENGTH (E): The magnitude of the electric field vector expressed in V/m MAGNETIC FIELD STRENGTH (H): The magnitude of the magnetic field vector expressed in A/m POWER DENSITY (S): Power per unit area normal to the direction of propagation, expressed in mW/cm 2 EMISSION: Radiation produced by a single radiofrequency source INMISION: Radiation resulting from the contribution of all radiofrequency sources whose fields are present in the place EXPOSURE: A situation in which people are subjected to electrical, magnetic or electromagnetic fields, or to contact or induced currents associated with electromagnetic fields of radiofrequencies POPULATION OR NON-CONTROLLED EXPOSURE: Situations in which the general public may be exposed or in which people exposed in the course of their work may not have been warned of the potential exposure and may not be able to control it

Maximum Permitted Values for Argentina Table of maximum permitted exposure levels for the population, for the different frequencies, pursuant to Resolution Nº 202/95 of the National Ministry of Health and Social Action Note:Levels similar to those established by the ICNIRP

Regulation Systems Predictive Method (theoretical calculation) Method of Measurement (practical development) Combination of the two methods: Fans vs. Critics Methods of Application, which depend on:  Types of radiofrequency sources  Density of the number of sources, for measurement purposes  Strength and frequency bands of the sources involved  Location of the sources involved  Political definition in the regulation system

Regulation Systems If Far Field is considered  evaluation of NIR values by calculation, based on Prediction Method If the Maximum Permitted Exposure (MPEs) limits are exceeded  the Measurement Method is used

Prediction Method Mono-Antenna Site Case Equations only valid for calculations in the far field, but can be used to predict the worse case S: Maximum Power Density (MPD) [W/m 2 ] PRA & PIRE: antenna power [W] F: attenuation of radiation for a certain angle of incidence in the vertical plane (F=1, worse case) 2.56: empirical reflection factor (reflected fields added in phase with direct incident field - 60%) r: distance from the antenna [m] If the distance from the antenna to all points to which the general public have access is ≥ r, it is not necessary to verify the site by means of measurements

Method of Measurement Determine the place to be measured Inspect the place chosen and determine the radiofrequency sources, types of emission, characteristics of irradiation and surrounding environment Determine the method of measurement (reactive or radiant near fields, far field) Determine tools and probes to be used in the measurement process Measurement protocol to be applied Define the points to be measured, based on the protocol chosen and the points where the greatest risk exists (ext. / int.) Perform the measurements and prepare reports

Method of Measurement Near Field  measure E, H or both (must comply with MPE limits imposed) Far Field  measure E or H and obtain S [S = E 2 /Z 0 = H 2 *Z 0 ] (must comply with MPE limits imposed) Sequence: Measure imission. If strictest MPE is exceeded, then measure the emission of each station Imission: use of broadband instruments (non-tuneable electromagnetic radiation detectors), with isotropic E and H measurement probes Emission: use of narrowband instruments (field intensity meters, tuenable spectrum analyzers, etc.), with antennae suitable for measurement frequency ranges All instruments, antennae and probes must have a calibration certificate (manufacturer or laboratory accredited in country of origin). Record the value of the measurement, plus the uncertainties specified (manufacturer), plus the error of the method used.

Models of Probes and Equipment Broadband probes

Models of Probes and Equipment Commercial instruments and probes for measuring radiofrequency Non-tuneable Tuneable Interchangeable antennae for measuring E or H field (Isotropic)

Models of Probes and Equipment Commercial instruments and antennae for measuring narrowband radiofrequency

Measurement Protocol (Arg.) Applicable to radioelectric radiocommunications stations and radiobroadcasting stations (from 300 kHz to 100 GHz); not exempt on account of prediction method or exceptional conditions. Points of measurement: Omni-directional systems:  a minimum of 16 points Directional systems:  s minimum of 4 points in direction of max. propagation  12 remaining points according to charact. of radiation lobe Note:More points may be included. Measured at peak time (of traffic or strength emitted)

Measurement Protocol (Arg.) Inmision: Sweep of peak value measurements [PV] (E, H or S) at the point of measurement:  If maximum PV ≤ 50% strictest MPE  that value is recorded  If maximum PV > 50% MPE  time-averaged measurement Time-averaged measurement:  Selection of 5 heights (separated by 20 cm and ≤ 2 m)  Measurement of components of E, H or S  At each height: time-averaging for 6 minutes. Record value and height.

Measurement Protocol (Arg.) Emission: Evaluation of individual contributions from each of the sources emitting NIR Points to be measured: those where the strictest MPEs were exceeded Use of narrowband instruments, with linear polarization antennae (with calibration certificate) Optional measurement methods:  Measurement of the 3 ortogonal components (x, y, z): E 2 = E x 2 + E y 2 + E z 2 o H 2 = H x 2 + H y 2 + H z 2  Point antenna in direction of strongest signal

Continuous Monitoring The methods evaluated are for use in specific cases or repeatedly, but over long periods of time. There are new measurement models, based on continuous detection (7 x 24) of potentially hazardous zones, with data published on the Internet, to which citizens have free access. Advantages: Population: has objective data, 24 hours a day, showing that the radiation values are below the maximums permitted. Municipal districts: their residents know that an extensive network is in place for monitoring electromagnetic radiation Service Providers: reduces the perception that their base stations are dangerous or a cause for concern.

Continuous Monitoring Conceptual Approach: Commercial Systems: CPqD Narda Wave Control

Commercial Models Monitoring System Measurements of broadband (from 5 Hz to 40 GHz, with different probes)Measurements of broadband (from 5 Hz to 40 GHz, with different probes) Use of isotropic probesUse of isotropic probes Cellular signal discrimination vs. other sources EMFCellular signal discrimination vs. other sources EMF Storing of peak values, AVG or RMS (up to 18 months)Storing of peak values, AVG or RMS (up to 18 months) Follow-up to measurement of EMFFollow-up to measurement of EMF Communication of data, alerts and configurations in a programmable wayCommunication of data, alerts and configurations in a programmable way Outdoor and Indoor installationOutdoor and Indoor installation

Commercial Models Monitoring System Permanent real time measurement at the field levelPermanent real time measurement at the field level Use of isotropic probeUse of isotropic probe Regular averaging of the measurementsRegular averaging of the measurements Memorization of maximum values by períodsMemorization of maximum values by períods Programmable threshold of level of alertProgrammable threshold of level of alert Margin of measurement: V/mMargin of measurement: V/m Wireless transfer of data to control centerWireless transfer of data to control center

Conclusions 1.There is no conclusive evidence that the predefined levels of NIR affect the population… 2.… but nor does evidence exist to prove that there are no effects when people are exposed to it for long periods 3.The issue continues to be studied (WHO, ICNIRP, etc.) 4.The first priority of our work should be prevention 5.It is worth defining and measuring the “hot points” 6.Repetitive, regular measurement methods to generate a statistical base (Maps of radiation - protected areas) 7.Balance between technological resources and human health (comfort and present society vs. prehistoric age) We can help you with the last 4 points

Introduction to the Measurement of Non- ionizing Radiation CONSULTORA FEDERAL DE COMUNICACIONES – Thank you very much – – Thank you very much – Alfredo Debattista