ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28.

Slides:



Advertisements
Similar presentations
SHORELINE SCHOOL DISTRICT Site & Facilities Assessment September 22, 2008 SHORECREST HIGH SCHOOL.
Advertisements

Loft Conversions - The building regulations Chris Wigley MD London Building Control Ltd
Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
February 12, 2010 Government Center Station Reconstruction Project Green Line / Blue Line Public Meeting December, 2012.
Fire-Resistive Construction (2nd part)
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Westminster Town Hall 1770 ● 1835 ● 1889 ● 2011 Continuing a Historical Legacy.
Guidelines and Required Codes That Affect Building Design
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Raymond School District Raymond School Facility Assessment Executive Summary September 16, 2013 Eppstein Uhen Architects Eric Dufek, Senior Design Architect.
Proposed Changes to the ADA & ABA Accessibility Guidelines This presentation was prepared by the U.S. Access Board for the ADA Distance Learning 2000 program.
GREENBERG TRAURIG, LLP | ATTORNEYS AT LAW | Application for Waiver(s) for The Waves Hotel in the Historic Lord Balfour Hotel Building 350.
Miscellaneous Details. u May have special or unusual conditions –inside or outside structure u Approach same as before –analysis of how specific detail.
Interim Life Safety Measures Eleven Administration Actions of Interim Life Safety Measures ÷Ensure free and unobstructed exits. Personnel receive additional.
Civil Engineering & Architecture 2.3 Residential Design.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
2004 Florida Accessibility Code for Building Construction
Facility Management. The International Facility Management Association defines facility management as a profession that encompasses multiple disciplines.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
Technology in Architecture Lecture 12 Electrical Equipment Electrical Power Management Fire Protection Systems Lecture 12 Electrical Equipment Electrical.
Church Administrators & Emergency Planning
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Schools (2/2) March 22 nd Context Administration facilities Staff facilities Safety and security measures.
S.M.A.R.T. Project Proposal December 9, 2014 Referendum.
Governmental Constraints on Construction Chapter 2.
Building Codes and Interior Design
GPP CDF Refurbishment ADA LEED Budget. DCEO Grant Proposal The DOE will also fund Fermilab to undertake a significant renovation and re-purposing of an.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 10 Slide 1 Unit 10 Commercial Construction.
FORUM Presented by ART GUADANO, AIA, LEED AP BD+C DURHAMTOWNHALL.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
Fire Safety By Alicia Civile and Alexandra Fernandez.
1 NEW FAIRFIELD FREE PUBLIC LIBRARY Renovation Project
Fair Housing in Focus Accessibility. Accessibility Properties fall under several different laws. Federal programs and the age of the property determine.
This question speaks to primary ownership of the room décor. Will the space be designed for contemporary worship that youth will be allowed to occupy.
Common Rental Property Code Compliance Issues Zoning – property usage Building Inspection – minimum standards for construction Housing Code – minimum standards.
May 23 rd, 2011 MALLS, SHOPPING CENTERS & MUSEUMS.
Chapter 44 Building Codes and Commercial Design. 2 Links for Chapter 44 Building Codes Design Categories Using the Codes Related Web Sites.
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
Engineering Analysis of NFPA 285 Tested Assemblies
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Codes.
Codes and costing construction + materials II. Building Code (780 CMR) Building Code (780 CMR) Accessibility Code (521 CMR) Accessibility Code (521 CMR)
GSA - ABAAS Leased Facilites Workshop
HILLSBORO COMMUNITY UNIT SCHOOL DISTRICT 3 HILLSBORO COMMUNITY UNIT SCHOOL DISTRICT 3 HILLSBORO, ILLINOIS High School Building Project.
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Services Currently Provided  FHA/ADA Inspections  Bank Draw Requests  Existing Condition Documentation Services.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Title III of the ADA: Overview of Architectural Requirements Amy F. Robertson Executive Director – Education
Fundamentals of Accessibility AIA Connecticut Presented by.
Disabled Access The Americans with Disabilities Act is based on the principle that disabled access is a civil right similar to rights based on race and.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
New Construction and Alterations in Title III 1 ADA Trainer Network Module 6d Trainer’s Name Trainer’s Title Phone /Website.
IRC 2009 OVERALL. SITE PLAN PROPERTY LINES LOCATION OF BUILDING GRADES STREETS.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
COMMUNITY ACCESS MONITOR TRAINING
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Code Review: Existing Building Code
Hannah Ehresman, Kelsey Russell, Kaitlyn Higgins, Lynette Akai
Building standards Mr. Da Silva.
Environmental factors need to be taken into account within healthcare and other settings For example Ceiling systems of a lay-in ceiling tile design should.
The Edge Extreme Makeover.
Presentation transcript:

ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28 Danforth Street Portland, ME T (207) F (207)

AMERICANS WITH DISABILITIES ACT (ADA) REQUIRES THAT “PERSONS WITH DISABILITIES ARE TO BE PROVIDED ACCOMMODATIONS AND ACCESS EQUAL TO, OR SIMILAR TO, THAT AVAILABLE TO THE GENERAL PUBLIC. ALTERATIONS TO HISTORIC PROPERTIES OUGHT TO BE IN FULL COMPLIANCE WITH THE ALTERATION STANDARDS FOR OTHER TYPES OF BUILDINGS. ALTERATIONS REQUIRE REVIEW BY THE APPROPRIATE LOCAL OR STATE ACCESS BOARD (STATE FIRE MARSHALL’S OFFICE).

AMERICANS WITH DISABILITIES ACT (ADA) IF BY FOLLOWING THE USUAL STANDARDS, THE HISTORIC SIGNIFICANCE WOULD BE DESTROYED OR THREATENED, THEN ALTERNATIVE STANDARDS MAYBE USED. PUBLIC ASSEMBLY SPACES IN HISTORIC STRUCTURES MUST MEET THE MINIMUM STANDARDS REQUIRED BY THE ADA TO THE MAXIMUM EXTENT FEASIBLE.

MINIMUM STANDARDS REQUIRED BY THE AMERICANS WITH DISABILITIES ACT (ADA) FOR HISTORIC STRUCTURES ACCESSIBLE ROUTE FROM A DESGINATED PARKING SPOT TO AN ACCESSIBLE ENTRANCE AN ACCESSIBLE INTERIOR ROUTE FROM THE ENTRANCE TO PUBLIC SPACES ON THE LEVEL OF THE ENTRANCE. AN ACCESSIBLE ENTRANCE. AT LEAST 1 ACCESSIBLE UNISEX TOILET ROOM COMPLY WITH STANDARDS FOR SIGNAGE, DISPLAYS, DOOR HARDWARE, WATER FOUNTAINS, SYSTEM CONTROLS, EXHIBITS, ETC.

LIFE SAFETY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME

ASSESSED USING INTERNATIONAL BUILDING CODE AND NATIONAL FIRE PROTECTION AGENCY PUBLICATIONS Doors do not meet hardware and egress requirements. The stairs do not meet the handrail, guardrail, and riser/tread requirements for existing egress stairs. The electrical system does not have safety features like ground fault interrupters and hardwired smoke detectors.

There are no hardwired-smoke detectors, heat detectors, carbon monoxide detectors, a sprinkler system or lightning protection. There is no fire separation between the boiler and oil tank enclosures and the remaining spaces. The fire escape is rusted and of insufficient design to serve as a second means of egress. In addition, the egress path of the fire escape passes several windows, which pose a significant threat to anyone using the fire escape.

STRUBLE ENGINEERING, LLC 603 Main Street Reading, MA (781) (781) Fax “The present stairs and fire escape do not provide handicap access.” Struble Engineering 1/10/2007 “This fire escape appears inadequate for use as public egress in the event of a fire.” Struble Engineering 1/10/21007

A new addition would be needed to achieve the goal of providing such access and could also be used to replace the non-Code compliant fire escape now serving the existing building. Such an addition would have to be structurally separate due to the fact that the present building uses unreinforced masonry as its lateral load resisting system which is prohibited in new construction of the type needed for this (egress) addition. STRUBLE ENGINEERING, LLC 603 Main Street Reading, MA (781) (781) Fax

ACCESSIBLE ROUTE FROM A DESGINATED PARKING SPOT TO AN ACCESSIBLE ENTRANCE

NEW SIDE ADDITION WITH A STAIR & ELEVATOR ACCESSIBLE ROUTE FROM A DESGINATED PARKING SPOT. AN ACCESSIBLE ENTRANCE. AN ACCESSIBLE INTERIOR ROUTE FROM THE ENTRANCE TO PUBLIC SPACES ON THE LEVEL OF THE ENTRANCE. (ttl-arch)

Multilevel buildings and facilities. An accessible route from an accessible entrance to public spaces on the level of the accessible entrance shall be provided. IBC 2009 Existing Building Accessibility Section 3411

Side Addition Location

Life Safety Cost Estimate in 2007 $’s Provide GFCI Outlets$1,850 Hardwire Smoke Detectors$1,500 Install Lever Hardware$4,500 Fire Extinguishers$900 Emergency Signs & Lighting$3,200 Lightening Protection$2,100 Sprinkler in Boiler Room$3,000 1 Hr Partitions in Basement$2,500 Remove Fire Escape$2,750 New Electrical Fixtures in Addition$6,000 New Stair Tower$112,000 Total $140,300

Handicap Accessibility Cost Estimate 2007 $’s Accessible Exterior Route$750 Accessible Interior Route$1,500 Accessible Entrance$15,000 4 Stop Elevator$130,000 Upgrade Electrical Service$15,000 $162,250

Life Safety $ 140,300 Handicap Accessibility $ 162,250 Total $ 302,550 + Architectural Design/Specifications Cost

Funding Possibilities

$ 56,000 available & approved $250,000 in the Capital Improvement Account (unencumbered) Write a Grant to help off set elevator cost Fund Raiser – Veterans ‘Hall of Honor’ *********************************

Next Steps? Discussion