Accelerator Science and Technology Centre Prospects of Compact Crab Cavities for LHC Peter McIntosh LHC-CC Workshop, CERN 21 st August 2008.

Slides:



Advertisements
Similar presentations
Unwanted mode damping in SRF deflecting/crabbing cavities G Burt Lancaster University / Cockcroft Institute.
Advertisements

Study of the Luminosity of LHeC, a Lepton Proton Collider in the LHC Tunnel CERN June F. Willeke, DESY.
X-Ray Pulse Compression Using Deflecting Cavities - Studies at LBNL Derun Li Center for Beam Physics, LBNL LHC IR Upgrades Workshop FNAL, Chicago, IL October.
S. N. “ Cavities for Super B-Factory” 1 of 38 Sasha Novokhatski SLAC, Stanford University Accelerator Session April 20, 2005 Low R/Q Cavities for Super.
All experimenters meeting – July 7, 2014 LHC Crab Cavity Overview Tom Nicol – Fermilab All Experimenter’s Meeting July 7, It’s a group effort –
Slim crab cavity development Luca Ficcadenti, Joachim Tuckmantel CERN – Geneva LHC-CC11, 5th LHC Crab Cavity Workshop.
Luminosity Prospects of LHeC, a Lepton Proton Collider in the LHC Tunnel DESY Colloquium May F. Willeke, DESY.
Design of Standing-Wave Accelerator Structure
DESIGN OF A 7-CELLS, HOM DAMPED, SUPERCONDUCTING CAVITY FOR THE STRONG RF FOCUSING EXPERIMENT AT DANE David Alesini, Caterina Biscari, Roberto Boni, Alessandro.
ALPHA Storage Ring Indiana University Xiaoying Pang.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
LEP3 RF System: gradient and power considerations Andy Butterworth BE/RF Thanks to R. Calaga, E. Ciapala.
SRF Results and Requirements Internal MLC Review Matthias Liepe1.
Zenghai Li SLAC National Accelerator Laboratory LHC-CC13 CERN, December 9-11, 2013 HOM Coupler Optimization & RF Modeling.
LHC Upgrade Part 4: RF systems for the LHC upgrade Erk Jensen/CERN Beams Department Radio Frequency Group.
Status of crab crossing studies Presented by NAKANISHI Kota (KEK) 2008/1/25.
DEFLECTING CAVITY OPTIONS FOR RF BEAM SPREADER IN LCLS II
Preliminary design of SPPC RF system Jianping DAI 2015/09/11 The CEPC-SppC Study Group Meeting, Sept. 11~12, IHEP.
704MHz Warm RF Cavity for LEReC Binping Xiao Collider-Accelerator Department, BNL July 8, 2015 LEReC Warm Cavity Review Meeting  July 8, 2015.
Dr G Burt (CI), Dr R. Rimmer (Jlab), H. Wang (Jlab) & B. Hall (CI)
Impedance measurements with the ILC prototype cavity Dr G. Burt Cockcroft Institute Lancaster University P. Goudket, P. McIntosh, A. Dexter, C. Beard,
KEK R&D for LHC Plan of 800MHz Cavity Calculation of 400MHz Cavity 16 th September 2009, LHC-CC09 at CERN K.Nakanishi.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Double RF system at IUCF Shaoheng Wang 06/15/04. Contents 1.Introduction of Double RF System 2.Phase modulation  Single cavity case  Double cavity case.
Global Design Effort ILC Crab Cavity Overview and requirements Andrei Seryi SLAC on behalf of ILC Beam Delivery and Crab-Cavity design teams Joint BNL/US-LARP/CARE-HHH.
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
Group 6 / A RF Test and Properties of a Superconducting Cavity Mattia Checchin, Fabien Eozénou, Teresa Martinez de Alvaro, Szabina Mikulás, Jens Steckert.
Design Optimization of MEIC Ion Linac & Pre-Booster B. Mustapha, Z. Conway, B. Erdelyi and P. Ostroumov ANL & NIU MEIC Collaboration Meeting JLab, October.
Review 09/2010 page RF System for Electron Collider Ring Haipeng Wang for the team of R. Rimmer and F. Marhauser, SRF Institute and Y. Zhang, G. Krafft.
FNAL efforts on LHC Crab Cavity R&D (Proposals for R&D sub-tasks, resources and schedule) Nikolay Solyak.
Nov. 28, 2003RF System Overview, K. Akai1 RF System Overview Contents: ◆ High beam current and measures ◆ Construction ◆ Damping ring RF system ◆ Crab.
704 MHz warm cavity November 4, 2015 A.Zaltsman: SRF & warm RF components for LEReC1  A single cell 704 MHz warm cavity is used to correct the beam energy.
WP10.3 Crab Cavities Overview EUCARD SRF Annual Review Peter McIntosh (STFC, ASTeC, Daresbury Laboratory) 4 – 5 May 2011, Orsay.
Bunch Separation with RF Deflectors D. Rubin,R.Helms Cornell University.
Compact Crab Cavity Status E. Jensen for WP4 R. Appleby, T. Baer, J. Barranco, I. Ben-Zvi, G. Burt, R. Calaga, E. Ciapala, S. Da Silva, J. Delayen, L.
Cryostat & LHC Tunnel Slava Yakovlev on behalf of the FNAL team: Nikolay Solyak, Tom Peterson, Ivan Gonin, and Timergali Khabibouline The 6 th LHC-CC webex.
LHC Cryostat evaluation Nikolay Solyak Thanks Rama Calaga, Tom Peterson, Slava Yakovlev, Ivan Gonin C11 workshop. FNAL, Oct 27-28, 2008.
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
UK-Jlab-TechX Designs for the LHC Crab Cavity Dr G Burt Lancaster University / Cockcroft Institute.
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
Update on LHC 800MHz Crab Cavity Conceptual Design Liling Xiao, Zenghai Li Advanced Computations Department, SLAC Presented at LARP-CM12, April 9, 2009.
Progress in unconventional RF structures Dr Graeme Burt Cockcroft Institute, Security Lancaster, Lancaster University.
Global Collaborations Towards LHC Crab Cavity J. P. Koutchouk Thanks to Rama Calaga and Rogelio Tomas Crab Cavity Validity Requirement Workshop August.
Crab Cavity Study with GDFIDL Narong Chanlek and Roger Jones 20/12/06.
RF Modeling of the LHC Crab Cavity Zenghai Li SLAC Zenghai Li LARP CM20 April 8-10, 2013.
Collimation Aspects for Crab Cavities? R. Assmann, CERN Thanks to Daniel Wollmann for presenting this talk on my behalf (criticism and complaints please.
WP 4: Crab Cavity Ed Ciapala, Erk Jensen BE-RF, CERN HL-LHC Meeting, CERN, 20 July 2010.
Page 1 Subashini De Silva Center for Accelerator Science Department of Physics, Old Dominion University and Thomas Jefferson National Accelerator Facility.
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
A Four Rod Compact Crab Cavity for LHC Dr C Lingwood for Dr G Burt Lancaster University / Cockcroft Institute.
RF Dipole HOM Electromagnetic Design
SRF Crabbing Cavity R&D
Review of options for crab cavities in LHC:
CEPC APDR Study Zhenchao LIU
Odu/slac rf-dipole prototype
fundamental equations of LHC performance
LHC Crab Cavity Conceptual Design at SLAC
Design Fabrication and Processing Group H. Padamsee
Physics design on Injector-1 RFQ
Developments on Proposed
Double Quarter Wave Crab Cavity
WP10.3 LHC Crab Cavities Overview EUCARD SRF Annual Review
Update of CLIC accelerating structure design
Overview of SRF system of Ring and Linac (1)
CEPC Main Ring Cavity Design with HOM Couplers
RF Parameters for New 2.2 km MEIC Design
Fanglei Lin, Yuhong Zhang JLEIC R&D Meeting, March 10, 2016
Status and plans for crab crossing studies at JLEIC
Update on Crab Cavity Simulations for JLEIC
Conventional Synchronization Schemes
Presentation transcript:

Accelerator Science and Technology Centre Prospects of Compact Crab Cavities for LHC Peter McIntosh LHC-CC Workshop, CERN 21 st August 2008

Accelerator Science and Technology Centre Overview CC Advantages for LHC LHC Constraints Local vs Global Compact CC R&D Underway Conclusions

Accelerator Science and Technology Centre CC Advantages for LHC

Accelerator Science and Technology Centre LHC CC R&D Plan From LHC-CC08 BNL, Feb 2008

Accelerator Science and Technology Centre LHC CC Voltage Requirement For LHC: –Bunch length = 7.55 cm –Crossing angle  mrad RF voltages required: –3 – 7 MV (deflecting) At 800 MHz: –1 module of the BNL/SLAC elliptical cavities (2-cell Cavity) At 400 MHz: –2 modules of the various compact CC designs Longitudinal Space ~ 5 m A flat beam option will give an extra degree of freedom for voltage delivered. 2 SRF Cells

Accelerator Science and Technology Centre Local vs Global Small crossing angle (~0.5 mrad): Global crab scheme is ideal choice for prototype Phase-I: –Test feasibility of crab crossing in hadron colliders, –Address all RF and beam dynamic issues, –Small orbit excursion and tune shifts, –Compatible with nominal and upgrade options to recover the geometric luminosity loss, –Collimation optimisation! –These cavities are feasible using available technology and the gradient requirements are within reach of current technology. Local crab crossing preferable (Phase-II): –Independent control at IPs, –Avoid collimation/impedance issues. The only local crossing scheme feasible with current technology requires VV crossing (see R. Calaga's talk). Need compact cavities to fit in the IR region of the ring. Lower frequency hopefully!

Accelerator Science and Technology Centre Compact CC Constraints Two key LHC constraints Transverse beam-line separation ( cm) Bunch length = 7.55 cm, 800 MHz ok (400 MHz preferred!) Local crab crossing scheme preferred to avoid problems with collimation & impedance issues. Parallel R&D for compact CC’s along with elliptical cavity development. Find best substitute for elliptical cavities among the several ideas. Copper and/or Niobium prototype to test SRF features.

Accelerator Science and Technology Centre Compact Cavity R&D Underway FNAL mushroom cavity (N Solyak) BNL offset TM 010 cavity (R Calaga) SLAC spoke cavity (Z Li) JLab rod cavity (H Wang) SLAC half wave resonator (Z Li) CI figure-8 cavity (G Burt)

Accelerator Science and Technology Centre FNAL Mushroom Cavity Coaxial coupler penetration adjusted for optimised damping. Aperture increased to 117 mm diameter. Reduced E-fields in coaxial line, avoid multipactor. Target Q ext < 1000 for all inactive modes.

Accelerator Science and Technology Centre FNAL Mushroom Cavity (Cont’d) ‏

Accelerator Science and Technology Centre BNL TM 010 Cavity (SRF) TM 010 is the lowest mode in pillbox cavity with largest R/Q. Transverse space becomes a non- issue even for 400 MHz. HOM damping becomes trivial: –No LOM to damp! Smaller peak surface fields compared to TM 110. Large transverse offset will increase coupling to beam with HOMs, need to evaluate impedance effects. Multipacting & non-zero beam loading needs evaluating to see if this design is attractive. Max B-Field at Equator

Accelerator Science and Technology Centre SLAC Spoke Cavity 0.3 m diameter Minimum iris radius of 60 mm needed, for effective cell-to-cell coupling. Dipole modes: Damping optimisation with input coupler required.

Accelerator Science and Technology Centre JLab Rod Cavity (NC) 2-rod separator cavity operating on CEBAF. Q cu is only ~5000 (structure wise), the stainless steel cylinder only takes less than 5% of total loss. Each cavity is: –499 MHz, –2-cell, –~ λ long –  0.3 m diameter, –can produce 400kV deflecting voltage with 1.5kW input RF power. The maximum surface magnetic field at the rod ends is ~14.3 mT. Water cooling needed on the rods. If Nb used for this type of cavity, the V  is  KEKB CC. Microphonics and fabrication issues to be resolved.

Accelerator Science and Technology Centre JLab Rod Cavity (SRF) Use “π” mode for separating three beams in CEBAF. No LOM damping required since the deflecting mode is the fundamental mode. Can a SRF version be made to work? Need to reduce the surface magnetic field at the rod ends. Need high B/E field near the beam path. Using cone shape electrodes can certainly reduce rod vibration and microphonics. Since there is a low loss on the cylinder can: –could make cavity cylinder in low RRR Nb, with rods in high RRR Nb? There are both magnetic and electric fields providing deflecting kick, E   B . The cavity tuner is in low field region. No field enhancement there. As rod separation increases, the B x and E y fields drop quickly.

Accelerator Science and Technology Centre SLAC Half Wave Cavity 400 MHz operating frequency. Crabbing voltage doubles c.f. 800 MHz. Single gap per cavity. Requiring 3-4 cavities per beam for small crossing angles (V  = 1.25 MV). Multipactor studies needed and damping optimisations verified.

Accelerator Science and Technology Centre SLAC Half Wave Cavity

Accelerator Science and Technology Centre SLAC Coaxial Input Coupler

Accelerator Science and Technology Centre CI Figure-8 Cavity A Figure-8 cavity allows a very compact cavity size ( m 400 MHz). Further optimisation will lead to a better field profile. Peak magnetic fields are 150 mT at V  = 5 MV.

Accelerator Science and Technology Centre CI Figure-8 Cavity The cavity has the two LOMs close to the operating mode at 336 MHz and 433 MHz. The mode at 433 MHz has a low R/Q as the fields cancel. Coupler optimisations ongoing. SRF fabrication process to be determined.

Accelerator Science and Technology Centre Conclusions Luminosity improvements with CCs clear … even at nominal  * parameters. Substantial increases predicted for lower  *. Lower frequency CC preferred for LHC. Space constraints for local crossing make lower frequency solution more difficult. Many compact cavity designs being pursued. Cavity optimisations, mode damping and multipactor studies ongoing. Very promising that a viable solution can be achieved. Need coordinated effort to focus R&D for compact CC design.