Morgan Ulloa March 20, 2008 Magnetic Resonance Imaging and the Fourier Transform.

Slides:



Advertisements
Similar presentations
RF Pulse – generates a B 1 field that realigns the precessing spins in the low energy state In the case of a 90 o pulse the alignment is perpendicular.
Advertisements

DFT/FFT and Wavelets ● Additive Synthesis demonstration (wave addition) ● Standard Definitions ● Computing the DFT and FFT ● Sine and cosine wave multiplication.
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Principles of MRI: Image Formation
Chapter 9 Basic MRI I Mark D. Herbst, MD, PhD. Notice This lecture contained many drawings on the whiteboard, so get these from one of the other students.
Magnetic Resonance Imaging
MRI. Magnetic Resonance 1.Principle first observed in Used for spectroscopy and imaging 3.Imaging techniques are a form of tomography, where slices.
The most important instrumental technique used by organic chemists to determine the structure of organic compounds. NMR spectroscopy helps to identify.
ELEG 479 Lecture #9 Magnetic Resonance (MR) Imaging
EEG Experiment for Extra Credit Sign up on the sheet.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
HCI 530 : Seminar (HCI) Damian Schofield. HCI 530: Seminar (HCI) Transforms –Two Dimensional –Three Dimensional The Graphics Pipeline.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Tomography Part 2.
Imagen de resonancia magnética Magnetic resonance imaging, G.A. WRIGHT IEEE SIGNAL PROCESSING MAGAZINE pp:56-66.
Nuclear Magnetic Resonance (NMR) Magnetic Resonance Imaging (MRI)
Basics of Magnetic Resonance Imaging
Markus Strohmeier Sparse MRI: The Application of
Magnetic Resonance Imaging
Computer Vision Lecture 3: Digital Images
Magnetic Resonance Imaging Basic principles of MRI This lecture was taken from “Simply Physics” Click here to link to this site.
Resonance condition. Pulse A coil of wire placed around the X axis will provide a magnetic field along the X axis when a direct current is passed through.
10/06/20041 Resolution Enhancement in MRI By: Eyal Carmi Joint work with: Siyuan Liu, Noga Alon, Amos Fiat & Daniel Fiat.
MAGENETIC RESONANCE IMAGINING T2, T5, T7.
Application of Digital Signal Processing in Computed tomography (CT)
MRI: an Introduction By Mohammad Ali Ahmadi Pajouh Amirkabir University of Technology Biomedical Eng. Dep.
Principles of MRI Physics and Engineering
Medical Physics Physics 421 Course Description: Medical Physics is a course with two main parts:  Physics of the body  Physics of Diagnostic and Therapeutic.
BME Medical Imaging Applications Part 2: INTRODUCTION TO MRI Lecture 2 Basics of Magnetic Resonance Imaging Feb. 23, 2005 James D. Christensen, Ph.D.
Physical and Chemical Tests 10-1 Purification: Chromatography Distillation Recrystallization Comparison to known compounds: Melting point Boiling point.
Nuclear Magnetic Resonance (NMR) Spectroscopy Structure Determination
Magnetic Resonance Imaging
Prof. Dr. Moustafa. M. Mohamed Dr. Eng. Safa Ahmed El-Askary
Magnetic Material Engineering. Chapter 6: Applications in Medical and Biology Magnetic Material Engineering.
Seminar October, 2008 j. brnjas-kraljević. Imaging (MRI)  tomography technique  tomography technique – the volume image is built up by images of thin.
L 36 Modern Physics [2] How lasers work Medical applications of lasers Applications of high power lasers Medical imaging techniques CAT scans MRI’s.
Week 11 © Pearson Education Ltd 2009 This document may have been altered from the original State that NMR spectroscopy involves interaction of materials.
Nuclear Magnetic Resonance Spectroscopy (NMR) Dr AKM Shafiqul Islam School of Bioprocess Engineering.
NMR in Medicine and Biology
Magnetic Resonance Imaging
Allen W. Song, PhD Brain Imaging and Analysis Center Duke University MRI: Image Formation.
Lecture 7: Sampling Review of 2D Fourier Theory We view f(x,y) as a linear combination of complex exponentials that represent plane waves. F(u,v) describes.
MRI Magnetic resonance imaging. Definition NMR = Nuclear Magnetic Resonance MRI = Magnetic Resonance Imaging ESR = Electron Spin Resonance.
FT NMR WORKSHOP/===/ S.A.I.F./===/ NEHU/==/ Shillong INTRODUCTORY LECTURE S.ARAVAMUDHAN Distinct Spectroscopic context.
Magnetic Resonance Imaging – Basic Principles –
Lecture 3: The MR Signal Equation We have solved the Bloch equation and examined –Precession –T2 relaxation –T1 relaxation MR signal equation –Understand.
Fourier Transform.
Introducing cross- sectional imaging Dr.Ahmed S. Tawfeek FIBMS(Rad.)
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
Magnetic Resonance Imaging Glenn Pierce, King’s College London, Department of Physics Introduction Edward Purcell and Felix Bloch were both awarded the.
 Introduction to reciprocal space
Structure Elucidation Method
A function is a rule f that associates with each element in a set A one and only one element in a set B. If f associates the element b with the element.
Charged particle. Moving charge = current Associated magnetic field - B.
MRI Magnetic Resonance Imaging. Definition A non-ionizing technique with full three dimensional capabilities, excellent soft-tissue contrast, and high.
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
Lecture 1: Magnetic Resonance
Lecture 3: The Bloch Equations Solved & the MR Signal Equation Solve the Bloch equation –Precession –T2 relaxation –T1 relaxation MR signal equation –Understand.
IB NOTES: Modern Analytical Chemistry. Definitions: Qualitative Analysis: The detection of the __________________ but not the __________ of a substance.
MOLECULAR STRUCTURE ANALYSIS NMR Spectroscopy VCE Chemistry Unit 3: Chemical Pathways Area of Study 2 – Organic Chemistry.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
11.1 Nuclear Magnetic Resonance Spectroscopy
Magnetic Resonance Imaging
MRI Pulse Sequences: IR, EPI, PC, 2D and 3D
Magnetic Resonance Imaging (MRI)
MRI: From Protons to Pixels
2D NMR spectroscopy So far we have been dealing with multiple pulses but a single dimension - that is, 1D spectra. We have seen, however, that a multiple.
How MRI Works By Wesley Eastridge, adapted from and with illustrations from The Basics of MRI by Joseph P. Hornak, Ph.D.
Introduction to MR Robert Frost
(4)ELECTRONIC SUPPORT SYSTEM
Introduction to MR Robert Frost
Presentation transcript:

Morgan Ulloa March 20, 2008 Magnetic Resonance Imaging and the Fourier Transform

Outline The Fourier transform and the inverse Fourier transform Fourier transform example 2-D Fourier transform for 2-D images Magnetic Resonance Imaging (MRI) Basic MRI physics K-Space and the inverse Fourier transform Overview of how an MRI machine works 3-D MRI

What is the Fourier transform A component of Fourier Analysis named for French mathematician Joseph Fourier ( ) The Fourier transform in an operator that inputs a function and outputs a function Inputs a function in the time-domain and outputs a function in the frequency-domain the Fourier transforms is used in many different ways Continuous Fourier transform is used for MRI

What the Fourier transform looks like Written as an integral: f(t) is a function in the time-domain ω=2πf known as the angular frequency i = square root of -1 (imaginary number) t is the variable time The Fourier transform takes a function in the time-domain into the frequency-domain

Inverse transform Also an integral: F(ω) is our Fourier transform in the frequency-domain ω=2πf known as the angular frequency i is the square root of -1 t is the variable time 1/(2 π) is a conversion factor The inverse Fourier transform takes a function in the frequency-domain back into the time-domain

Different functions and their Fourier transforms

Example: 1) Define time-domain function 2) Compute our integral: =  Improper integral  = = Note: Has a real part and an imaginary part

 from the definition of the integral of products of trigonometric functions  =  simplifying the fractions  = 3) Understanding what this means - searching for a specific frequency (ω)

The 2-D Fourier transform Begin with a 2-D array of data: t’ by t’’ Since this data is two dimensional we say that the data is in the spatial domain

1 st Fourier Transform First Fourier transform in one direction: t’

2 nd Fourier Transform Finally in the t’’ direction The spike corresponds to the intensity and location of the frequency within the 2-D frequency domain

What is MRI? Originally called nuclear magnetic resonance (NMR) but now it is called MRI in the medical field because of negative associations with the word nuclear –Thus, on the atomic level MRI utilizes properties of the nucleus, specifically the protons It takes tomographic images of structures inside the human body similar to an x-ray machine –Unlike the x-ray this imaging technique is non-ionizing

Tomography Tomography: slice selection, with insignificant thickness, of a 3-D object

Spin and spin states Certain atoms have protons that create tiny magnetic fields in one of two directions: this is called spin –some common and important types of atoms with this property are 1 H, 13 C, 19 F, 31 P –Hydrogen protons are used for MRI in the human body Usually the spins of protons in a compound are oriented randomly but if they are exposed to a magnetic field they either align themselves with it, called parallel alignment, or against it, called antiparallel alignment. The parallel and antiparallel alignments are called spin states The energy difference between the spin states lies within the radio frequency spectrum

Resonance When a magnetic field is applied the protons oscillate between their two spin states: between antiparallel and parallel alignment A radio frequency is applied by the MRI machine and varied until it matches the frequency of the oscillation: this is called resonance Whilst in this state of resonance the protons will absorb and release energy –This is then measured by a radio frequency receiver on the MRI machine The energy difference of the two spin states depends on the response of protons to the magnetic field in which it lies and, since the magnetic field is affected by the electrons of nearby atoms, each MRI scan produces a spectrum that is unique to the compounds present in the tomographic slice

Radio Frequency Spectrum Spectrum: the distribution of energy emitted by a radiant source

Axes of a 2-D slice x-axis called the phase-encoding axis y-axis called the frequency encoding axis

Regions of spin A region of spin is simply a location within the 2-D slice plane where protons are expressing their unique characteristic: spin For the purposes of explaining the 2-D Fourier transform we will use 2 regions of spin with similar material compositions but different locations: labeled 1 and 2

Imagining these regions of spin These regions of spin can be depicted visually by vectors (magnetization vectors) rotating around the origin at a frequency corresponding to their rates of oscillation

x-axis: Phase Encoding Magnetic field gradient is applied to the slice along the x-axis to both regions of spin The radio frequency bursts are applied and both regions of spin resonate at different frequencies because they have different positions –when the gradient is turned off they will have a different phase angle, φ Phase angle: the angle between the reference axis (y) and the magnetization vectors

Phase encoding: Cuts the slice into rows

y-axis: Frequency encoding The magnetic field gradient is then applied along the y-axis This results in the two spin vectors rotating at unique frequencies about the origin Thus each region of spin now has a unique rotational frequency and a unique phase angle

Frequency encoding: cuts the slice into columns

Using the Fourier transform with this data Mapping these rotations about the origin as functions of time we get two unique time-domain signals each with a unique phase and rotational frequency and we can create a 2-D array of data with our rows and columns To these we can apply the Fourier transform as we did before in the t’ and t’’ directions but this time in the frequency encoding direction and the phase encoding direction – therefore our data is in the spatial domain, not the time domain as with 1-D Fourier transform This process identifies the the position and the intensity of the spin within the 2-D slice plane

A visual of how this works… We have our two unique signals plotted as a 2-D array of data

… First Fourier transform in the frequency encoding direction

… Then Fourier transform in the phase encoding direction The spikes indicate frequency intensity and location of our regions of spin

What is the K-space? A matrix known as a temporary image space which holds the spatial frequency data from a 2-D Fourier transform The number of entries in each row and column correspond to the number of regions of spin within the slice plane and their location Each matrix entry is given a pixel intensity and thus each entry contains both frequency and spatial data These entries form a grayscale image –Whiter entries correspond to high intensity signals –Darker entries correspond to low intensity signals

K-space for the two regions of spin The k-space for our two regions of spin is the following matrix which clearly demonstrates the position and intensity (here the difference in color) of each region

K-space and the Image

From the K-space to a recognizable image Inverse transforming the K-space yields a new grayscale image that corresponds to the physical slice plane, thus creating an accurate image representation of the slice in vivo

MRI imaging process A slice is selected from the body Magnetic Field gradient is applied to the slice in the Phase encoding and Frequency encoding directions –only the protons within the slice to oscillate between their two energy states (spin states) At the same time radio frequency pulses are applied to the slice with a bandwidth capable of exciting all resonances simultaneously The emitted energy is measured by a radio frequency receiver and converted into a spectrum in the time- domain in the x-direction and y-direction thereby creating a 2-D array of data in the spatial domain

…MRI process continued The two time-domain functions of the spatial-domain is then Fourier transformed into a 2-D frequency- domain function with information about the position and frequency intensity of the spin regions This data is entered into the K-space and then inverse Fourier transformed creating a corresponding accurate image of the physical slice

Stacking Slices: the 3-D image

References: Campbell, Iain D., and Raymond A. Dwek. Biological Spectroscopy. Menlo Park, Ca: Benjamin/Cummings Company, Gadian, David G. Nuclear Magnetic Resonance and Its Applications to Living Systems. New York: Oxford UP, Hornak, Joseph P. "The Basics of MRI." Rochester Institute of Technology. 30 Sept Hsu, Hwei P. Applied Fourier Analysis. Orlando: Harcourt Brace Jovanovich, Knowles, P. F., D. Marsh, and H.W.E. Rattle. Magnetic Resonance of Biomolecules. John Wiley & Sons, Mansfield, P., and P. G. Morris. NMR Imaging in Biomedicine. New York: Academic P, Swartz, Harold M., James R. Bolton, and Donald C. Borg. Biological Applications of Electron Spin Resonance. John Wiley & Sons, 1972.

Many thanks to Professor Ron Buckmire & the Occidental Mathematics Department