MEGN 536 – Computational Biomechanics Prof. Anthony J. Petrella Basics of Medical Imaging Introduction to Mimics Software
Medical Imaging Used for measuring anatomical structures… size, shape, relative position in body Can reconstruct geometry for modeling purposes X-ray techniques planar x-rays, mammography, chest x-ray, bone fracture CT scans – computed tomography Nuclear imaging, radioactive isotope planar imaging, bone scan positron emission tomography (PET) MRI – magnetic resonance imaging Ultrasound
Medical Imaging Ionizing Non-ionizing Broken molecular bonds, DNA damage May produce heating, induce currents Non-thermal, low induction Ultrasound (~1mm)
X-ray Imaging (Roentgenogram) Wilhelm Röntgen ( ) Nov 1895, announces X-ray discovery Jan 1896, images needle in patient’s hand 1901, receives first Nobel Prize in Physics Röntgen’s wife, 1895
X-ray Imaging X-ray film shows intensity as a negative ( dark areas, high x-ray detection)
X-ray Imaging X-ray film shows intensity as a negative ( dark areas, high x-ray detection) = radiolucency
CT Imaging Computed tomography Tomography – imaging by sections or sectioning, creation of a 2D image by taking a slice through a 3D object 2D images are captured with X-ray techniques X-ray source is rotated through 360° and images are taken at regular intervals CT image is computed from X-ray data
CT Imaging Developed by Sir Godfrey Hounsfield, engineer for EMI PLC 1972 Nobel Prize 1979 (with Alan Cormack) “Pretty pictures, but they will never replace radiographs” –Neuroradiologist 1972 early today
Exhalation Inhalation
How a CT Image is Formed X-ray source is rotated around body for each slice Patient is moved relative to the beam Figure below does not show it well, but the X-ray beam has a thickness each slice has a thickness Note: slice thickness
How a CT Image is Formed Figures below show only two views 90° apart A process of “back projection” is used to indicate regions where X-ray attenuation is greater – i.e., tissue is more dense
How a CT Image is Formed Example at left w/ only 2 views shows poor image Clinical CT uses several hundred views for each slice Data collected in matrix
CT Image Data Recall that each CT slice has a thickness each element in the data matrix for a single CT slice represents a measurement of X-ray attenuation for a small volume or “voxel” of tissue X-ray attenuation is expressed in terms of the X-ray attenuation coefficient, which is dependent primarily on tissue density
CT Numbers CT numbers are expressed in Hounsfield units (HU) and normalized to the attenuation coefficient of water (atomic number)
CT Numbers & Viewing a CT Image CT numbers usually recorded as 12-bit binary number, so they have 2 12 = 4096 possible values Values arranged on a scale from HU to HU Scale is callibrated so air gives a value of HU and water has a CT number of 0 HU Dense cortical bone falls in the to HU range HU HU
MR Imaging Magnetic resonance imaging 1946: Felix Block and Edward Purcell discover magnetic resonance : Richard Ernst and Peter Mansfifield develop MR imaging An object is exposed to a spatially varying magnetic field, causing certain atomic nuclei to spin at their resonant frequencies An electromagnetic signal is generated and varies with spatial position and tissue type Hydrogen is commonly measured – hence, good contrast for soft tissues that contain more water than hard tissues like bone
MR Imaging – 30 Years Later “Interesting images, but will never be as useful as CT” –Neuroradiologist (different), 1982 First brain MR image Contemporary Image
Notes on CT v. MR Images CT image based on X-ray beam attenuation, depends on tissue density CT images generally regarded as better for visualization & contrast in bone imaging Bone density and modulus can be estimated MR image based on resonance of certain atomic nuclei, e.g. hydrogen MR images generally regarded as better for visualization & contrast in imaging soft tissues, which contain more water than bone
3D Reconstruction CT & MR images represent 2D slices through 3D anatomic structures 2D slices can be “stacked” and reconstructed to form an estimate of the original 3D structure
Mimics Software Mimics ( is the leading commercial software program for reconstruction of CT & MR image datawww.materialise.com/mimics
What Data Format Does Mimics Read? Most medical images are saved in the DICOM image format What is DICOM? The standard for Digital Imaging and Communications in Medicine Developed by the National Electrical Manufacturers Association (NEMA) in conjunction with the American College of Radiology (ACR) Covers most image formats for all of medicine Specification for messaging and communication between imaging machines You don’t need to know the details of the format, but Mimics is happiest when reading DICOM images
What If You Don’t Have DICOM Data? You will need to use manual input methods with to read the data You need to know something about the images A CT or MR scan consists of many slices We will be focused on bone modeling, so CT data will be our main interest It is also important to remember how a CT image slice is formed and what data it contains
Data in an Image File The format of CT numbers in the data file depends on the precision of the binary data For CT numbers, we only need to cover the 12-bit range, to 3071 short has 2 bytes = 2 × 8 bits/byte = 2 16 binary values = 65,536 When using unsigned shorts the data is shifted so all CT numbers are positive 0 to 4095
Data in an Image File Recall a single CT slice is a matrix of data 512 x 512 is a common size 262,144 pixels Each element in the matrix represents a pixel value with a binary format of “short”, therefore each pixel contains 2 bytes of data 262,144 x 2 = 524,288 bytes, any additional data is part of the “header”
Data in an Image File Visible Human link on class website Data are available for download Download sample of Visible Human data from today’s Class Notes page These images are 512 x 512 and the data format is unsigned short How large is the header (bytes)?
Data in an Image File 512 x 512 = 262,144 pixels Each element in the matrix represents a pixel value with a binary format of “short”, therefore each pixel contains 2 bytes of data 262,144 x 2 = 524,288 bytes, any additional data is part of the “header” Total file size is 527,704 header is 3416 bytes
Starting Mimics You should find a Mimics icon on the desktop… or Find “Materialise Software” in Start menu… or Type “Mimics” in the Start menu search box Run Mimics The software should ask if you want to reboot… click “No” or “Reboot Later” If Mimics doesn’t start then on it’s own, attempt to start it again
Mimics Tutorials Complete Lessons 1 and 2 in Mimics SE Course Book, pages 8-28 You will need the Mimics SE Course Data, which is posted on the front page of the class website If you don’t have your Course Book, it is also posted on the class website