The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.

Slides:



Advertisements
Similar presentations
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Advertisements

LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
NLC – The Next Linear Collider Project Colorado Univ. - Boulder Calorimetry Cornell-ALCPG Calorimetry Detector Study Plans at Colorado Uriel Nauenberg.
NLC – The Next Linear Collider Project Colorado Univ. - Boulder Calorimetry-Arlington Calorimetry Detector Study Plans at Colorado Uriel Nauenberg for.
Parameterized Shower Simulation in Lelaps: a Comparison with Geant4 Daniel Birt, Amy Nicholson.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
ECAL Spike Plot Approval ECAL Anomalous Signal Plots Approval Adi Bornheim for ECAL
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
1 Measurement of f D + via D +   + Sheldon Stone, Syracuse University  D o D o, D o  K -  + K-K- K+K+ ++  K-K- K+K+ “I charm you, by my once-commended.
D. Peterson, “TPC Detector Response Simulation and Track Reconstruction”, SLAC, 07-Jan For example: TPC: 2.0 m O.R., 0.5 m I.R., 150  m spatial.
Energy Flow Studies Steve Kuhlmann Argonne National Laboratory for Steve Magill, Brian Musgrave, Norman Graf, U.S. LC Calorimeter Group.
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Measurement of B (D + →μ + ν μ ) and the Pseudoscalar Decay Constant f D at CLEO István Dankó Rensselaer Polytechnic Institute representing the CLEO Collaboration.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
Evaluation of G4 Releases in CMS (Sub-detector Studies) Software used Electrons in Tracker Photons in the Electromagnetic Calorimeter Pions in the Calorimeter.
Progress with the Development of Energy Flow Algorithms at Argonne José Repond for Steve Kuhlmann and Steve Magill Argonne National Laboratory Linear Collider.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
Monte Carlo Comparison of RPCs and Liquid Scintillator R. Ray 5/14/04  RPCs with 1-dimensional readout (generated by RR) and liquid scintillator with.
Beam test results of Tile/fiber EM calorimeter and Simulator construction status 2005/03/05 Detector Niigata University ONO Hiroaki contents.
Calibration of the ZEUS calorimeter for electrons Alex Tapper Imperial College, London for the ZEUS Collaboration Workshop on Energy Calibration of the.
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
EAS Reconstruction with Cerenkov Photons Shower Simulation Reconstruction Algorithm Toy MC Study Two Detector Configuration Summary M.Z. Wang and C.C.
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
シンチレータストリップを用いた 高性能電磁カロリメータの開発 (公募研究A1) 研究代表者 川越清以 ( 神戸大学 ) with the GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) 9-Mar-2004, 科研費特定領域.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
UTA GEM DHCAL Simulation Jae Yu * UTA DoE Site Visit Nov. 13, 2003 (*On behalf of the UTA team; A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee,
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Positional and Angular Resolution of the CALICE Pre-Prototype ECAL Hakan Yilmaz.
Feasibility Study of Forward Calorimeter in ALICE experiment Sanjib Muhuri Variable Energy Cyclotron Centre Kolkata.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
13 July 2005 ACFA8 Gamma Finding procedure for Realistic PFA T.Fujikawa(Tohoku Univ.), M-C. Chang(Tohoku Univ.), K.Fujii(KEK), A.Miyamoto(KEK), S.Yamashita(ICEPP),
3D Event reconstruction in ArgoNeuT Maddalena Antonello and Ornella Palamara 11 gennaio 20161M.Antonello - INFN, LNGS.
11/18/2016 Test beam studies of the W-Si tracking calorimeter for the PHENIX forward upgrade Y. Kwon, Yonsei Univ., PHENIX.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
Performance of Shower Maximum Detectors Saori Itoh (Shinshu Univ.) GLC calorimeter group (KEK,Kobe,Konan,Niigata,Shinshu,Tsukuba) Introduction Detector.
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
Reconstructing energy from HERD beam test data Zheng QUAN IHEP 3 rd HERD work shop Xi’an, 20 Jan
Longitudinal shower profile - CERN electron runs Valeria Bartsch University College London.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
Muons at CalDet Introduction Track Finder Package ADC Corrections Drift Points Path Length Attenuation Strip-to-Strip Calibration Scintillator Response.
7/13/2005The 8th ACFA Daegu, Korea 1 T.Yoshioka (ICEPP), M-C.Chang(Tohoku), K.Fujii (KEK), T.Fujikawa (Tohoku), A.Miyamoto (KEK), S.Yamashita.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
2005/07/12 (Tue)8th ACFA Full simulator study of muon detector and calorimeter 8th ACFA Workshop at Daegu, Korea 2005/07/12 (Tue) Hiroaki.
Study of Calorimeter performance using the LC full simulator The 8th ACFA Workshop Yoshihiro Yamaguchi (Tsukuba U.) M. -C. Chang (RCNS, Tohoku U.) K. Fujii.
Report on the Beam Test Analysis Satoru Uozumi Apr GLDCAL meeting Topics of this talk are: Comparison of various MIP calibration methods Some problems.
PAC questions and Simulations Peter Litchfield, August 27 th Extent to which MIPP/MINER A can help estimate far detector backgrounds by extrapolation.
Use of the D0 Central Preshower in Electron Identification John Gardner University of Kansas APS April 6, 2003.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
DESY BT analysis - updates - S. Uozumi Dec-12 th 2011 ScECAL meeting.
or getting rid of the give-away particles in a test-beam environment
CALICE scintillator HCAL
GLAST Large Area Telescope:
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Detector Configuration for Simulation (i)
ScECAL+AHCAL+TCMT Combined Beam FNAL
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Study of a Scintillating Digital Hadron Calorimeter Prototype
Rick Salcido Northern Illinois University For CALICE Collaboration
Detector Optimization using Particle Flow Algorithm
Michele Faucci Giannelli
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Rick Salcido Northern Illinois University For CALICE Collaboration
Presentation transcript:

The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider November,9-12, 2004, Taipei, Taiwan A. Nagano University of Tsukuba

2004/11/10 7th ACFA Workshop 1 Contents Response Uniformity Shower profile Spatial resolution Angle measurement Summary

2004/11/10 7th ACFA Workshop 2 Response uniformity in the 1 cm-width direction The minimum ionizing particle (MIP) Response uniformity is examined to check if it is uniform enough to keep the good energy resolution Scanning step : 0.5 mm  Tracking resolution : 0.3 mm The response uniformity is calculated as a RMS of the response over a mean of the response in a central region of 7mm. Response uniformity in the 1 cm-width direction : 2.4 % 1st super layer

2004/11/10 7th ACFA Workshop 3 Scanning step : 1 cm Uniformity in the 1st super layer superposed strip events. Read out is +10cm, Wave Length Shifter fiber attenuation is seen. The response uniformity is calculated as deviation from the fitted straight line in a central region of 18cm. Response uniformity in the 20 cm-long direction : 1.6 % Response uniformity in the 20 cm-long direction The minimum ionizing particle (MIP)

2004/11/10 7th ACFA Workshop 4 Scanning step : 1 mm Response uniformity in which the response sum over the longitudinal strips and the response sum over all x-strips are plotted as a function of the incident beam position. Response uniformity for x-layer : 1.1 % Response uniformity in the 1 cm-width direction 4 GeV electron

2004/11/10 7th ACFA Workshop 5 Shower profile In the idea of the fine- segmented electromagnetic calorimeter, it is very important to have a good capability of separating photon-originated electromagnetic clusters from charged tracks. A typical event display for 4 GeV electron.

2004/11/10 7th ACFA Workshop 6 Integrated lateral shower profile The energy fraction I (x)  X dc ; the incident position reconstructed with drift chamber  X i ; position of i th strip.  x = X dc – X i  I(0) = 0.5 X dc XiXi x Pulse height (MIPs)

2004/11/10 7th ACFA Workshop 7 Integrated lateral shower profile Integrated shower profile, I(x) of a shower cluster for 4 GeV electron and MIP. The widths for 90 % shower containment : 1.5 cm at 2nd super layer (shower max). The MIP spread which originated from the light leakage between adjacent strips is much smaller than electron spread.

2004/11/10 7th ACFA Workshop 8 Smeared function of the lateral shower spread A small deviation between 4 GeV electron data and GEANT3-based shower simulation. This deviation is thought to come from the detector effect such as light leakage between adjacent strips. The smearing of the lateral shower spread in the simulation using the information on the light leakage seen in the MIP signal spread. Beam test data Smeared function

2004/11/10 7th ACFA Workshop 9 Lateral shower profile Integrated lateral shower profile I(x) can be parameterized as a double exponential of the following form: The smeared function fs(x) is defined by the following equation This smeared lateral shower profile in the simulation is consistent with the lateral shower profile for electron data.

2004/11/10 7th ACFA Workshop 10 RMS of lateral shower profile RMS of the cluster To examine the fluctuation of the lateral shower profile. The measured lateral shower profile for electron data was found to be well described by the simulation, including the fluctuation on the shower by shower basis. simulation data

2004/11/10 7th ACFA Workshop 11 Spatial resolution at 2nd super layer for 4 GeV electron The shower centroid, x shower is obtained by the fitting energy deposits in 5 strips to a Gaussian. The distribution of the position difference between the shower centroid, x shower at the 2nd super layer and the track extrapolation, x dc for 4 GeV electron.

2004/11/10 7th ACFA Workshop 12 Spatial resolution The position resolution can be parameterized as the following form : at the 2nd super layer in the energy range 1 GeV and 4 GeV.

2004/11/10 7th ACFA Workshop 13 The angle distribution measured by the calorimeter The shower direction is obtained by a linear fit of the centroid positions in the super layer In this calculation, only first 4 super layers are used for fitting because in the last 2 super layers the signals are small and the resolutions are worse.

2004/11/10 7th ACFA Workshop 14 The angular resolution The angular resolution using the electron beams with 0 degree in the energy range between 1 GeV and 4 GeV.

2004/11/10 7th ACFA Workshop 15 Angle measurement In the beam test, we performed data taking with the electron trigger, with an incident beam angle varying from 0 to 15.9 degree. The distribution of the angle measured by the calorimeter.

2004/11/10 7th ACFA Workshop 16 The comparison with the incident angle The comparison of the angles measured by the calorimeter with the incident angle.

2004/11/10 7th ACFA Workshop 17 Summary Response uniformity  MIP 1cm-width direction : 2.4 %  MIP 20cm-long direction : 1.6 %  4 GeV electron x-layer : 1.1 % Lateral shower spread  The width for 90 % shower containment 1.5 cm at 2nd super layer Position resolution at 2nd super layer Angle resolution

Appendix Tracking Longitudinal shower profile Spatial resolution

2004/11/10 7th ACFA Workshop 19 Tracking Position distribution Position distribution at the most down stream chamber. This beam profile indicates that the beam profile is smaller than the size (5x5 cm) of the nearest trigger counter.

2004/11/10 7th ACFA Workshop 20 Tracking Residual distribution The incident position resolution at the calorimeter surface is evaluated to be 300 micro m

2004/11/10 7th ACFA Workshop 21 The response at x=-0.5 cm The response in a certain region of each scintillator is determined by the mean of the pulse height distribution.

2004/11/10 7th ACFA Workshop 22 Longitudinal shower profile The longitudinal shower profiles for electron data are also consistent with the simulation result.

2004/11/10 7th ACFA Workshop 23 Correlation plot at the 2nd super layer The position calculated by the method is compared with that determined with the drift chamber.

2004/11/10 7th ACFA Workshop 24 The position resolution at each super layer