Optimizing Radiation Treatment Planning for Tumors Using IMRT Laura D. Goadrich Industrial Engineering & Department of Computer Sciences at University.

Slides:



Advertisements
Similar presentations
Operations Research Assistant Professor Dr. Sana’a Wafa Al-Sayegh 2 nd Semester ITGD4207 University of Palestine.
Advertisements

Transportation Problem (TP) and Assignment Problem (AP)
10th Annual Lung Cancer Conference Radiation Oncology
Computational Methods for Management and Economics Carla Gomes Module 8b The transportation simplex method.
Predicting the parameters of a prostate IMRT objective function based on dose statistics under fixed parameter settings Renzhi Lu, Richard J. Radke 1,
Optimisation of Irradiation Directions in IMRT Planning Rick Johnston Matthias Ehrgott Department of Engineering Science University of Auckland M. Ehrgott,
Radiotherapy Planning Stephen C. Billups University of Colorado at Denver
Chapter 2 Matrices Finite Mathematics & Its Applications, 11/e by Goldstein/Schneider/Siegel Copyright © 2014 Pearson Education, Inc.
Background:  IMRT has become the choice of treatment for disease sites that require critical structure sparing such as head and neck cancer.  It has.
Effects of Sampling in IMRT Optimization by Ronald L. Rardin Professor of Industrial Engineering Purdue University West Lafayette, Indiana, USA Caesarea.
Principles of Robust IMRT Optimization Timothy Chan Massachusetts Institute of Technology Physics of Radiation Oncology – Sharpening the Edge Lecture 10.
Goldstein/Schnieder/Lay: Finite Math & Its Applications, 9e 1 of 86 Chapter 2 Matrices.
Radiation Therapy (RT). What is cancer? Failure of the mechanisms that control growth and proliferation of the cells Uncontrolled (often rapid) growth.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Proton Imaging and Fighting Cancer
1 The Use of Fuzzy Optimization Methods for Radiation Therapy of Tumors Weldon A. Lodwick.
Finite Mathematics & Its Applications, 10/e by Goldstein/Schneider/SiegelCopyright © 2010 Pearson Education, Inc. 1 of 86 Chapter 2 Matrices.
Chip Planning 1. Introduction Chip Planning:  Deals with large modules with −known areas −fixed/changeable shapes −(possibly fixed locations for some.
Radiotherapy Planning for Esophageal Cancers Parag Sanghvi, MD, MSPH 9/12/07 Esophageal Cancer Tumor Board Part 1.
به نام خداوند بخشایندۀ بخشایشگر
What Happens in the days before treatment ?
CSE554Laplacian DeformationSlide 1 CSE 554 Lecture 8: Laplacian Deformation Fall 2012.
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation.
Comparison of Rectal Dose Volume Histograms for Definitive Prostate Radiotherapy Among Stereotactic Radiotherapy, IMRT, and 3D-CRT Techniques Author(s):
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Data Mining to Aid Beam Angle Selection for IMRT Stuart Price-University of Maryland Bruce Golden- University of Maryland Edward Wasil- American University.
Brachytherapy Medical radiation.
Parameter selection in prostate IMRT Renzhi Lu, Richard J. Radke 1, Andrew Jackson 2 Rensselaer Polytechnic Institute 1,Memorial Sloan-Kettering Cancer.
Laura Goadrich13 Dec 2004 A Metaheuristic for IMRT Intensity Map Segmentation Laura D. Goadrich October 15, 2004 Supported with NSF Grant DMI
Kelly Younge, Ph.DKelly Younge, Ph.D Don Roberts, Benedick Fraass, Daniel McShan, and Martha Matuszak University of Michigan, Department of Radiation Oncology,University.
Sampling Issues for Optimization in Radiotherapy Michael C. Ferris R. Einarsson Z. Jiang D. Shepard.
MIT and James Orlin © More Linear Programming Models.
A Metaheuristic for IMRT Intensity Map Segmentation Athula Gunawardena, Warren D’Souza, Laura D. Goadrich, Kelly Sorenson, Robert Meyer, and Leyuan Shi.
Linear Programming.  Linear Programming provides methods for allocating limited resources among competing activities in an optimal way.  Any problem.
Prepared By : Miss. Sana’a AL-Sulami Teacher Assistant.
Chapter 7 Transportation, Assignment & Transshipment Problems
Deterministic Operations Research Models J. Paul Brooks Jill R. Hardin Department of Statistical Sciences and Operations Research November 28, 2006.
Copyright © 2013, 2009, 2005 Pearson Education, Inc. 1 5 Systems and Matrices Copyright © 2013, 2009, 2005 Pearson Education, Inc.
Strong Bounds for Linear Programs with Cardinality Limited Violation (CLV) Constraint Systems Ronald L. Rardin University of Arkansas
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Institute for Advanced Radiation Oncology
Introduction to Optimization Models EXCEL Modeling of Simple Linear Problems 1 Archis Ghate Assistant Professor Industrial and Systems Engineering
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Medical considerations to guide mixed integer formulations of IMRT planning problems from MD to NP to CR Mark Langer, MD Radiation Oncology Indiana University.
PHARMACOECONOMIC EVALUATIONS & METHODS MARKOV MODELING IN DECISION ANALYSIS FROM THE PHARMACOECONOMICS ON THE INTERNET ®SERIES ©Paul C Langley 2004 Maimon.
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
F. Foppiano, M.G. Pia, M. Piergentili
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
1 CS612 Algorithms for Electronic Design Automation CS 612 – Lecture 8 Lecture 8 Network Flow Based Modeling Mustafa Ozdal Computer Engineering Department,
Minimizing Beam-On Time in Cancer Radiation Treatment Using Multileaf Collimators Natashia Boland Horst W. Hamacher Frank Lenzen January 4, 2002.
Introduction to Radiation Therapy
Optimization of Volumetric Modulated Arc Therapy (VMAT) Planning Strategy Using Ring-shaped ROI for Localized Prostate cancer Kentaro Ishii, Masako Hosono,
Athula D. A. Gunawardena, Michael C. Ferris and Robert R. Meyer University of Wisconsin-Whitewater, and University of Wisconsin-Madison.
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Saad El Din I, M.D *, Abd El AAl H, M.D *, Makaar W, M.D *, El Beih D, M.Sc †, Hashem W, M.Sc * *Department of Clinical Oncology and Radiotherapy, Kasr.
Understanding Radiation Therapy
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Understanding Radiation Therapy Lecturer Radiological Science
Kasey Etreni BSc., MRT(T), RTT, CTIC
A. Sánchez-Reyes. , N. López Vilanova+, A. Vila. , M. A. Duch+, A
Fig. 4. Percentage of passing rate between clinical and 544 plans.
Reducing Treatment Time and MUs by using Dynamic Conformal Arc Therapy for SBRT Breath-Hold Patients Timothy Miller, Sebastian Nunez Albermann, Besil Raju,
Insert tables Insert figure
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Chapter 7 Transportation, Assignment & Transshipment Problems
FOUNDATIONS OF MODERN SCIENTIFIC PROGRAMMING
An Introduction to Radiotherapy
Chapter 1. Formulations.
Conformal Terminology
Presentation transcript:

Optimizing Radiation Treatment Planning for Tumors Using IMRT Laura D. Goadrich Industrial Engineering & Department of Computer Sciences at University of Wisconsin-Madison April 19, 2004

Overview Radiotherapy motivation Conformal radiotherapy IMRT Mechanical constraints MIP method Input/output Langer, et. al. Approach Monoshape constraints Implementation results References

Motivation 1.2 million new cases of cancer each year in U.S. (times 10 globally) Half undergo radiation therapy Some are treated with implants, but most with external beams obtained using radiotherapy treatments.

Radiotherapy Motivation Used to fight many types of cancer in almost every part of the body Approximately 40% of patients with cancer needs radiation therapy sometime during the course of their disease Over half of those patients who receive radiotherapy are treated with an aim to cure the patient to treat malignancies to shrink the tumor or to provide temporary relief of symptoms In the use of radiation, organ and function preservation are important aims (minimize risk to organs at risk (OAR)).

Planning Radiotherapy- CAT scan Conduct scans of the section of the body containing the tumor Allows physicians to see the OAR and surrounding bodily structures

Planning Radiotherapy- tumor volume contouring Isolating the tumor from the surrounding OAR is vital to ensure the patient receives minimal damage from the radiotherapy Identifying the dimensions of the tumor is vital to creating the intensity maps (identifying where to focus the radiation)

Planning Radiotherapy- beam angles and creating intensity maps Multiple angles are used to create a full treatment plan to treat one tumor. Through a sequence of leaf movements, intensity maps are obtained

Option 1: Conformal Radiotherapy The beam of radiation used in treatment is a 10 cm square. Utilizes a uniform beam of radiation ensures the target is adequately covered however does nothing to avoid critical structures except usage of some blocks

Option 2: IMRT Intensity Modulated Radiotherapy (IMRT) provides a shaped array of 3mm beamlets using a Multi-Leaf Collimator (MLC), which is a specialized, computer-controlled device with many tungsten fingers, or leaves, inside the linear accelerator. Allows a finer shaped distribution of the dose to avoid unsustainable damage to the surrounding structures (OARs) Implemented via a Multi-Leaf Collimator (MLC) creating a time- varying opening (leaves can be vertical or horizontal).

Classical vs. IMRT

IMRT machine

IMRT: Planning- intensity map There is an intensity map for each angle 0 means no radiation 100 means maximum dosage of radiation Multiple beam angles spread a healthy dose A collection of shape matrices are created to satisfy each intensity map.

Intensity map to shape matrices Original Intensity Matrix Shape Matrix 1 Shape Matrix 2 Shape Matrix 3 Shape Matrix 4

Program Input/Output Input: An mxn intensity matrix A=(a i,j ) comprised of nonnegative integers Output: T aperture shape matrices d t ij such that z K of the matrices are used where K < T Non-negative integers  t (t=I..T) giving corresponding beam-on times for the apertures Apertures obey the delivery constraints of the MLC and the weight-shape pairs satisfying K is the total number of required shape matrices

Mechanical Constraints After receiving the intensity maps, machine specific shape matrices must be created for treatment There are numerous types of IMRT machines currently in clinical use, with slightly different physical constraints that determine the leaf positions (hence the shape matrices) possible for the device Each machine has varying setup times which can dominate the radiation delivery time (beam-on time) To limit patient discomfort and subtle movement from initial placing: limit the time the patient is on the table Goals: Minimize beam-on time Minimize number of different shapes

Approach: Langer, et. al. Mixed integer program (MIP) with Branch and Bound by Langer, et. al. (AMPL solver) MIP: linear program with all linear constraints using binary variables Langer suggests a two-phase method where First minimized beam-on time T is the upper bound on the number of required shape matrices Second minimize the number of segments (subject to a minimum beam-on time constraint) g t = 1 if an element switches from covered to uncovered (vice versa) = 0 otherwise

In Practice While Langer, et. al. reports that solving both minimizations takes a reasonable amount of time, he does not report numbers and we have found that the time demands are impractical for real application. To obtain a balance between the need for a small number of shape matrices and a low beam-on time we have found that numShapeMatricies*7 + beam-on time Initializing T close to the optimal number of matrices + 1 required reduces the solution space and solution time

Constraint: Leaves cannot overlap from right and left To satisfy the requirement that leaves of a row cannot override each other implies that one beam element cannot be covered by the left and right leaf at the same time p t ij = 1 if beam element in row i, column j is covered by the right leaf when the t th monitor unit is delivered = 0 otherwise l t ij is similar for the right leaf d t ij contains the final t th monitor unit

Constraint: Full leaves and intensity matrix requirements Every element between the leaf and the side of the collimator to which the leaf is connected is also covered (no holes in leaves).

Constraint: No leaf collisions Due to mechanical requirements, leaves can move in only one direction (i.e. the right leaf to the right). On one row, the right and left leaves cannot overlap

Constraint: Shape matrices reqs The total number of shape matrices expended it tallied z= 1 when at least one beam element reamins exposed when the t th monitor unit in the sequence is delivered = 0 otherwise I is the number of rows J is the number of columns Must satisfy the intensity matrix for each monitor unit. I is the intensity assigned to beam element ij

Constraint: Monoshape The IMRT delivery is required to contain only one shape matrix per monitor unit, a monoshape First determine which rows in each monitor unit are open to deliver radiation delivery it =1 if the i th row is being used a time t = 0 otherwise Determine if the preceding row in the monitor unit delivers radiation drop it =1 if the preceding row (i-1) in a shape is non-zero and the current row (i) is 0 = 0 otherwise

Constraint: Monoshape Determine when the monoshape ends jump it =1 if the preceding row (i-1) in a shape is zero and the current row (i) is nonzero = 0 otherwise There can be only one row where the monoshape begins and one row to end

Complexity of problem To account for all of the constraints there is a large number of variables and constraints.

Comparison of results Corvus version 4.0

Comparison of results Corvus version 5.0

Referenced Papers N. Boland, H. W. Hamacher, and F. Lenzen. “Minimizing beam-on time in cancer radiation treatment using multileaf collimators.” Neworks, Mark Langer, Van Thai, and Lech Papiez, “Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimators,” Medical Physics, 28(12), Ping Xia, Lynn J. Verhey, “Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments,” Med. Phys. 25 (8), T.R. Bortfield, D.L. Kahler, T.J Waldron and A.L.Boyer, X-ray field compensation with multileaf collimators. Int. J. Radiat. Oncol. Biol. 28 (1994), pp Bortfield, Thomas, et. al. “Current IMRT optimization algorithms: principles, potential and limitations” Presentation Dink, Delal, S.Orcun, M. P. Langer, J. F. Pekny, G. V. Reklaitis, R. L. Rardin, “Importance of sensitivity analysis in intensity modulated radiation therapy (IMRT)” 2003.