AHCAL Saturation Study CALICE week – Casablanca, Morocco 2010/09/22 Jaroslav Zalesak Institute of Physics, Prague / DESY Study of single SiPM response.

Slides:



Advertisements
Similar presentations
Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
Advertisements

2 Introduction   MiniCal test-beam studies started at the beginning of March (till March 6 we only had 17 APD’s, then 33 APD’s)   A few days were.
1 AHCAL answers IDAG Erika Garutti On behalf of AHCAL analysis team.
Adil Khan Kyungpook National university Korea-Japan Joint ScECAL Group Meeting kobe University Japan 3 rd September 2010.
CALICE WHCAL testbeam at SPS H8 27 sep – 03 oct: 6 days for energies up to 180 GeV (+ polarity)
Tail Catcher/Muon Tracker at DESY & FNAL TB Facilities Northern Illinois Center for Accelerator and Detector Development Northern Illinois University and.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Sep 13, 2007CALICE Collaboration Meeting Prague 1 Long term test of LED pulsing  Long LED system stability measurement  Aging of part of optical system.
ECAL electronics Guido Haefeli, Lausanne PEBS meeting 10.Jan
Calibration issues for the CALICE 1m 3 AHCAL LCWS11 - International Workshop on Future Linear Colliders Granada, Spain 2011/9/28 Jaroslav Zalesak Institute.
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
Tests of the fiber-based calibration system CALICE collaboration meeting Cambridge, UK 2012/9/18 Jaroslav Zalesak Institute of Physics, Prague  QMB1 LED.
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
May 11, 2006CALICE Collaboration Meeting, McGill Uni, Montréal, Québec, CA 1 UV LED quality test  All 872 UV LEDs tested  Selection is about to finish.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Reports from DESY Satoru Uozumi (Staying at DESY during Nov 11 – 25) Nov-21 GLDCAL Japan-Korea meeting.
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Uni Bergen:G. Eigen, J. Zalieckas, E. van der Kraaij FZU Prague: J. Cvach, J. Kvasnicka, I. Polák CALICE meeting, Argonne, 19/03/2014.
Saturation in V-calib LED scans CALICE AHCAL – Main Meeting 2010/07/05 Jaroslav Zalesak analysis still in progress but gives global results FNAL & CERN.
AHCAL Electronics. Status Commissioning and Integration Peter Göttlicher for the AHCAL developers CALICE meeting UT Arlington, March 12th, 2010.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
1 Status of the calorimeter PMT’s time alignment LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Introduction Development status of the PMT time.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Uni Bergen:G. Eigen, E. van der Kraaij, J. Zalieckas FZU Prague: J. Cvach, J. Kvasnička, I. Polák Linear Collider Workshop, Tokyo 13/11/2013.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
NA62 Gigatracker Working Group Meeting 23 March 2010 Massimiliano Fiorini CERN.
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
5 July 2010Ivo Polák, FZU, Prague LED notched fibre distributing system Calibration system for SiPM Ivo Polák, Ji ř í Kvasni č ka
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
ScECAL Fermilab Beam Test analysis ScECAL Group Meeting Kyungpook National University, Daegu, Republic of Korea, July 22 nd, 2011 Adil Khan.
AHCAL Electronics. SPIROC2 and HBU measurement results Mathias Reinecke CALICE main meeting Univ. HASSAN II, Casablanca, Morocco Sept. 23rd, 2010.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
Idea for next data taking at FNAL Dec-14 th 2008 ScECAL S. Uozumi (Kobe)
Calibration issues for the CALICE 1m3 AHCAL ALCPG11 - Linear Collider Workshop of the Americas Eugene, Oregon, USA 2011/3/22 Jaroslav Zalesak Institute.
AHCAL Electronics. integration status and open issues Mathias Reinecke CALICE main meeting Univ. HASSAN II, Casablanca, Morocco Sept. 23rd, 2010.
G. Eigen, Paris, Introduction The SiPM response is non-linear and depends on operating voltage (V-V bd ) and temperature  SiPMs need monitoring.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Sergey BarsukElectromagnetic Calorimeter for 1 Electromagnetic Calorimeter for the LHCb experiment Perugia, Italy March 29 – April 2, 2004 ECAL CALO Sergey.
1 XCAL LED quality check and time alignment consideration CALO meeting Anatoli Konoplyannikov [ITEP / LAPP] Outline  CALO sub-detector status.
M.D. Nov 27th 2002M0' workshop1 M0’ linearity study  Contents : Electronic injection Laser injection Beam injection Conclusion.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Scintillator HCAL prototype commissioning and calibration J.Cvach Institute of Physics AS CR, Prague Calibration basics Test results Outlook LCWS 06.
1 CALICE Tail-Catcher Muon-Tracker(TCMT) Preliminary Test Beam Results Kurt Francis NICADD/Northern Illinois University For CALICE Collaboration ALCPG.
LED notched fibre distributing system Calibration system for SiPM
LED notched fibre system short HBU0 party with QMB6
ScECAL+AHCAL+TCMT Combined Beam FNAL
Correction of saturation effect of ICCD
Scintillator tile- SiPM systems R&D
Testbeam analysis on module #1
Scintillator HCal Prototype
Presentation transcript:

AHCAL Saturation Study CALICE week – Casablanca, Morocco 2010/09/22 Jaroslav Zalesak Institute of Physics, Prague / DESY Study of single SiPM response function on AHCAL Compare FNAL & CERN calibration data Application of temperature correction

Jaroslav Zalesak, Institute of Physics, Prague CALICE in Casablanca, Sep 22, Calibration chain: ADC to MIP What do we need: Lightyield in [pix/MIP]: - MIP amplitude in ADC bins... C i MIP - SiPM gain: (CalibMode) ADC bins converts to pixel... G pix - Electronics Intercalibration: between PM/CM mode... I C - SiPM response function: corrects the non-linear response of the SiPM … f sat (A i [pix]) A[pix] A[ph.e] AHCAL signal chain: Particle shower → MIPs → scintillator → photons (UV) → SiPM (non-linear) → photo-electrons → amplification → electronics Calibration: convert detector signal into number of MIPs deposited by particle traversing the tile & correct for non linear response of SiPM

Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, N tot =1156 pix  Saturation curves for single SiPM should be universal…BUT:  Disagreement between ITEP (bare SiPM) and in-situ (on-tile) measurement  Not all pixels illuminated by WLS light!  Ratio of geometrical area it is expected that only 78.5 % of the SiPM area (square) is illuminated by the WLF fiber  different number of dead pixels in each SiPM could change this number  Total number of pixels in a SiPM = 1156 Try to determine saturation factor for each channel separately test-bench response Saturation curves

LED light intensity scan Runs:  LED light intensity scan using physics mode of the ASIC chip  FNAL 2008 & 2009, CERN 2007 periods Fitted 10 (or more) points Fit simple Exponential formula for saturation: F(A ADC ) = N * [1- Exp(-(X+C)*B) ] X … LED intensity Extract parameter N -> ‘Saturation factor’ (Slope = B * N, Shift = -C) Jaroslav Zalesak, Institute of Physics, Prague 4 CALICE in Casablanca, Sep 22, 2010 Example: 18 different channels

Calibration in pixels Calibration of single cell formula: N pix = N ADC (T 2 ) * I C / G pix (T 1 ) G pix = G pix + dG/dT * ΔT, ΔT = (T 1 - T 2 ) use G pix, I C, dG/dT from DB for individual channel T from 5 temperature sensors on each module (closest one chosen) Jaroslav Zalesak, Institute of Physics, Prague 5 CALICE in Casablanca, Sep 22, pix 0.8 * 1156 pix cell# (18*chip + channel) N[pix]

Procedure Good events - curves: – Tags: graph, fit function, Chi2(Ndf !=0) available – Calibration constants, slopes & temperatures exist in DB for ch. – No saturated curves: no ADC saturation + smooth increasing fce – Fit parameters lay in (wide) ranges: saturation, shift, slope, errors – At least one good fitted curve among run in the groups using one intensity scan run only ~50% of curves fit extending the sample of curves studied to all available calibration runs (144/66 at FNAL/CERN) the number of converged fits increases to ~82-84% (of tot. 7608) for the other channels used default value 0.8 Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22,

Performance & Stability Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, Example: 144 fits (FNAL) for one channel for ‘good’ runs similar behavior → extract saturation factor N[ADC] for all channels → apply calibration to pixels & temperature corrections → N[pix] → consistent results for all runs? → averaged over all runs → unique curve for all channels? Fits: one channel, all runs N[ADC]

Results I: ADCbins,Pixels,T corr Pixels… Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, FNAL: ADC bins FNAL: Pixels FNAL: T corr Pixels CERN: T corr Pixels X-axis: cell# (18*chip + channel)

Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, Results II: Temperature correction Temperature corr. RMS = 0.7% RMS = 2.7%  Temperature correction is working well Pixels T corr Pixels

Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, Comparison: FNAL versus CERN T corr Pixel % of T corr Pixel / 1156  Good correlation between saturation point extracted from CERN and FNAL data  Both data sets shows average effective number of pixels at a level of 80% of phys. number (w/ RMS ~ 7%)

Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, FNAL-CERN Asymmetry T corr Pixels : Mean=-0.0% σ = 2.2% FNAL: peak 82.9%, σ=5% CERN: peak 82.9%, σ=5%  Temperature correction cancels the difference in mean.  The signal does not degrade (small error of T correction factor)  But long tails with wrong fit either at CERN or FNAL or both. ~10% outside 3σ-range

Effect of channel-by-channel corrections on EM analysis Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22, Energy linearity of response Residual of linear fit to energy  single-cell calibration does not improve the linearity w.r.t. a common rescaling factor → simplifies calibration chain of high-multi channel calor. global rescaling factor X single cell saturation

ToDo & Improvement  The measurement of the saturation curves is being done with re-commission AHCAL for W-option 2010 tests at CERN  Much more data points are taken for curves to cover all ranges (154 > 1h data taking → not possible during beam data) Jaroslav Zalesak, Institute of Physics, Prague 13 CALICE in Casablanca, Sep 22, 2010 fine scan 154 points > 1 hour standard procedure 32 points 15 min scan

Conclusion Jaroslav Zalesak, Institute of Physics, PragueCALICE in Casablanca, Sep 22,  Analysis gives results for single SiPM saturation curves over all available calibration runs from TB at CERN & FNAL  Performance is improved with averaging of the results over all runs from both periods up to 6360 (84%) ch. after sel. criteria  The calibration and temperature correction seem to work very well and improve the results  Both data sets FNAL & CERN give consistent results: ~83% of pixels illuminated by WLS fiber light  Still remaining outliers channels which are not or can not be fitted properly