The DEFLECT III Trial: A Prospective Randomized Evaluation of the TriGuard Embolic DEFLECTion Device during Transcatheter Aortic Valve Replacement Alexandra.

Slides:



Advertisements
Similar presentations
Ghanem et al., J Am Coll Cardiol 2010;55:1427–32..
Advertisements

STS 2015 John V. Conte, MD Professor of Surgery Johns Hopkins University School of Medicine On Behalf of the CoreValve US Investigators Transcatheter Aortic.
The DEFLECT III Trial: A Prospective Randomized Evaluation of the TriGuardTM HDH Embolic DEFLECTion Device during Transcatheter Aortic Valve Implantation.
Radial versus Femoral Randomized Investigation in ST Elevation Acute Coronary Syndrome the RIFLE STEACS study Enrico Romagnoli, MD PhD Principal investigators:
SURGICAL ABLATION OF ATRIAL FIBRILLATION DURING MITRAL VALVE SURGERY THE CARDIOTHORACIC SURGICAL TRIALS NETWORK Marc Gillinov, M.D. For the CTSN Investigators.
ACC 2015 Michael J Reardon, MD, FACC On Behalf of the CoreValve US Investigators A Randomized Comparison of Self-expanding Transcatheter and Surgical Aortic.
Lessons from TAVR Randomized Trials and Registries E Murat Tuzcu, MD Professor of Medicine Cleveland Clinic Financial disclosures: None PARTNER Executive.
Long-Term Outcomes Using a Self- Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Deemed Extreme Risk for Surgery: Two-Year Results From.
Blood Pressure Reduction Among Acute Stroke Patients A Randomized Controlled Clinical Trial Jiang He, Yonghong Zhang, Tan Xu, Weijun Tong, Shaoyan Zhang,
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
Impact of Concomitant Tricuspid Annuloplasty on Tricuspid Regurgitation Right Ventricular Function and Pulmonary Artery Hypertension After Degenerative.
Prasugrel vs. Clopidogrel for Acute Coronary Syndromes Patients Managed without Revascularization — the TRILOGY ACS trial On behalf of the TRILOGY ACS.
The Risk and Extent of Neurological Events Are Equivalent for High-Risk Patients Treated With Transcatheter or Surgical Aortic Valve Replacement Thomas.
Prosthesis-Patient Mismatch in High Risk Patients with Severe Aortic Stenosis in a Randomized Trial of a Self-Expanding Prosthesis George L. Zorn, III.
Axel Linke University of Leipzig Heart Center, Leipzig, Germany Sabine Bleiziffer German Heart Center, Munich, Germany Johan Bosmans University Hospital.
Naotsugu Oyama, MD, PhD, MBA A Trial of PLATelet inhibition and Patient Outcomes.
TCT 2015 | San Francisco | October 15, 2015 Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses Danny Dvir, MD John G. Webb, MD and.
The Impact of Prior Stroke on the Outcome of Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement Romain Didier, MD;
UC c EN. Through Medtronic sponsored research, the Transcatheter Aortic Valves clinical portfolio is studying over 11,000 subjects at over 125.
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
Martin B. Leon, MD on behalf of the PARTNER Investigators TCT 2010; Washington, DC; September 23, 2010 Transcatheter Aortic Valve Implantation in Inoperable.
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
: PROFI : A Prospective, Randomized Trial of Proximal Balloon Occlusion vs. Filter Embolic Protection in Patients Undergoing Carotid Stenting Klaudija.
G. Michael Deeb, MD On Behalf of the US Pivotal Trial Investigators 3-Year Results From the US Pivotal High Risk Randomized Trial Comparing Self-Expanding.
Ten Year Outcome of Coronary Artery Bypass Graft Surgery Versus Medical Therapy in Patients with Ischemic Cardiomyopathy Results of the Surgical Treatment.
1 Jeffrey J. Popma, MD Professor of Medicine Harvard Medical School Director, Interventional Cardiology Beth Israel Deaconess Medical Center Boston, MA.
Longest Follow-up After Implantation of a Self-Expanding Repositionable Transcatheter Aortic Valve: Final Follow-up of the Evolut R CE Study Stephen Brecker,
G. Michael Deeb, MD On Behalf of the CoreValve US Investigators
Martin B. Leon, MD Key Messages Tryton Pivotal: Randomized Trial and
The Impact of Preoperative Renal Dysfunction on the Outcomes of Patients Undergoing Transcatheter Aortic Valve Replacement Andres M. Pineda MD, J. Kevin.
TAVR in Patients With Chronic Kidney Disease
Embolic Protection Devices in Transcatheter Aortic Valve Replacement: Are We Barking Up the Wrong Vascular Tree? Circulation: cardiovascular intervention.
TriGuard Device for Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement: A Multicenter Real-World Experience Masieh Abawi, Ermela.
Outcomes in the CoreValve US High-Risk Pivotal Trial in Patients with a Society of Thoracic Surgeons Predicted Risk of Mortality Less than or Equal to.
Everolimus-eluting Bioresorbable Vascular Scaffolds in Patients with Coronary Artery Disease: ABSORB III Trial 2-Year Results Stephen G. Ellis, MD,
Extending the Boundaries of TAVR: Future Directions
Highlights From the SAPIEN 3 Experience in Intermediate-Risk Patients Vinod H. Thourani, MD on behalf of the PARTNER Trial Investigators Professor.
Eric Van Belle MD-PhD, Nicolas Debry MD et al. Heart Institute
Are we ready to perform TAVI in Intermediate Risk Patients?
Preventive Role of Embolic Protection Devices:
Updates From NOTION: The First All-Comer TAVR Trial
Transcatheter or Surgical Aortic Valve Replacement in Intermediate Risk Patients with Aortic Stenosis Description: The goal of the trial was to assess.
Heart Valve Thrombosis & Neuro-Outcomes
Claret Cerebral Protection Device: Implications of the Sentinel Study
30-Day Safety and Echocardiographic Outcomes Following Transcatheter Aortic Valve Replacement with the Self-Expanding Repositionable Evolut PRO System.
Stroke After TAVR: Surgeon View
First Report of Three-Year Outcomes With the Repositionable and Fully Retrievable Lotus™ Aortic Valve Replacement System: Results From the REPRISE I.
David R. Holmes, Jr., M.D. Mayo Clinic, Rochester
Early Outcomes with the Evolut R Repositionable Self-Expanding Transcatheter Aortic Valve in the United States Mathew Williams, MD, For the Evolut R US.
Giuseppe Tarantini MD, PhD
TAVI „Catch me if you can!“
Devices for Stroke Prevention
Longevity of transcatheter and surgical bioprosthetic aortic valves in patients with severe aortic stenosis and lower surgical risk Lars Sondergaard,
Vinod H. Thourani, MD on behalf of The PARTNER Trial Investigators
CoreValve Continued Access Study Shows Continued Improvement in 1-Year Outcomes With Self-Expanding Transcatheter Aortic Valve Replacement Steven J. Yakubov,
Axel Linke University of Leipzig Heart Center, Leipzig, Germany
Cerebral Embolic Protection In Patients Undergoing Surgical Aortic Valve Replacement (SAVR) Michael Mack, MD, Michael Acker, MD, Steve Messe, MD For.
One Year Outcomes in Real World Patients Treated with Transcatheter Aortic Valve Implantation The ADVANCE Study Axel Linke University of Leipzig Heart.
Technology Overview and Perspective from DEFLECT III
S.G. Worthley, MB, BS, PhD., S. Redwood, MD, PhD.,
Balloon-Expandable Transcatheter Valve System : OUS Data
Late Follow-Up from the PARTNER Aortic Valve-in-Valve Registry
Cardiovacular Research Technologies
Median total new lesion volume
3-Year Clinical Outcomes From the RESOLUTE US Study
The Synergy between Percutaneous Coronary Intervention with TAXUS and Cardiac Surgery: The SYNTAX Study One Year Results of the PCI and CABG Registries.
Five-Year Outcomes after Randomization to Transcatheter or Surgical Aortic Valve Replacement: Final Results of The PARTNER 1 Trial Michael J. Mack, MD.
The Synergy between Percutaneous Coronary Intervention with TAXUS and Cardiac Surgery: The SYNTAX Study One Year Results of the PCI and CABG Registries.
An ancillary study to the ARCADIA trial
Transcarotid Artery Revascularization versus Transfemoral Carotid Artery Stenting for Treatment of Carotid Artery Stenosis Patric Liang, MD; Marc L.
Presentation transcript:

The DEFLECT III Trial: A Prospective Randomized Evaluation of the TriGuard Embolic DEFLECTion Device during Transcatheter Aortic Valve Replacement Alexandra Lansky, MD Yale University School of Medicine New Haven, CT Joachim Schofer, Szilard Voros, Adam Brickman, Didier Tchetche, Pieter Stella, Jochen Reinöhl Thomas Cuisset, Daniel Blackman, Michael Cleman, John Forrest, Gil Bolotin, Med Spitzer, Martine Gilard, Thomas Modie, David Hildick-Smith, Kevin Abrams, Michael Haude, and Andreas Baumbach

Disclosure Statement of Financial Interest Affiliation Financial Relationship Research grants: Consultant/Speaker Honoraria: Minor Ownership interest: Company Keystone Heart, Bard, Biotronik, Boston Scientific, CardioKinetix, Direct Flow, Gilead Sciences, Gore, Intact Vascular, Micell, Recor Medical, Shockwave Medical, SilkRoad Medical, St Jude Medical, TriReme Medical, Ventrix Medical, Veryan Medical AstraZeneca Pharmaceuticals, Eli Lilly and Company, Daichi Sankyo, CardioDX, Merk & Co. Keystone Heart

Clinical Stroke after TAVR 30-day stroke rates 4-7% at 30 days in RCTs Generally under-reported (17% after SAVR when evaluated by neurologist) Confer 3- to 9-fold increased risk of mortality 50% are peri-procedural Stroke is the most devastating complication following TAVI. For many patients the fear of stroke is greater than the fear of mortality Leon et al. NEJM. 2010;363:1597, Smith et al. NEJM. 2011;364:2187, Adams et al. NEJM 2014;370:1790, Leon MB ACC 2013, Popma et al. JACC 2014;63:1872, Eggebrecht et al. EuroIntervention. 2012;8:129, Messe et al. Circulation 2014;129:2253, Tchetche et al. JACC Cardiovasc Interv 2014;7:1138, Miller et al. J Thorac Cardiovasc Surg 2012;143:832

Silent Embolic Events on DW-MRI after TAVR % of Subjects with New Lesions Affect 58-100% of patients Multiple infarcts (≤36, x̅ = 4.6) Associated with: Neurocognitive decline >2 fold risk of dementia >3 fold risk of stroke Stroke is the most devastating complication following TAVI. For many patients the fear of stroke is greater than the fear of mortality Restrepo et al. Stroke 2002;33:2909, Lund et al. Eur Heart J. 2005;26:1269, Schwarz et al. Am Heart J 2011;162:756, Knipp et al. Ann Thorac Surg 2008;85:872, Vermeer et al. NEJM 2003; 348:1215, Vermeer et al. Stroke 2003; 34:1126, Arnold et al. JACC Cardiovasc Interv. 2010;3:1126, Astarci et al. J Heart Valve Dis. 2013;22:79, Fairbairn et al. Heart 2012;98:18, Ghanem et al. EuroIntervention. 2013;8:1296, Kahlert et al. Circ. 2010;121:870, Knipp et al. Interact Cardiovasc Thorac Surg. 2013;16:116, Linke et al. TCT 2014, Rodes-Cabau et al. JACC Cardiovasc Interv 2014;7:1146

The TriGuard Device Single-wire nitinol frame and mesh filter with pore size of 130μm designed to deflect cerebral emboli during TAVR while allowing maximal blood flow Device is positioned across all 3 cerebral vessels and maintained by a stabilizer in the innominate Delivered via 9 Fr sheath from femoral artery

DEFLECT III Study Overview Design: Multicenter prospective single-blind randomized controlled trial at 13 sites (EU/IL) Objective: To evaluate the safety, efficacy and performance of TriGuard protection compared with unprotected TAVR. Sample Size: Exploratory study with no formal hypothesis testing. 86 patients selected to benchmark events for the design of a pivotal RCT. Subjects with AS undergoing TAVR 1:1 Randomization 31 2009 09 08 - 05:07:24 PM 4 00007508 MA 287847 MA 287847 2009 09 08 - 05:07:24 PM 4 31 Embolic Protection (TriGuard) Unprotected TAVR (Control) 5

DEFLECT III Eligibility Criteria Key Inclusion Criteria Patients undergoing TAVR via the transfemoral approach Exclusion Criteria Stroke or TIA within prior 6 months Any other cardiac intervention within prior 2 weeks Aortic arch or innominate anatomy deemed to prevent positioning and stability of the device (ostium diameter <11 mm, transverse aortic diameter >40 mm) Contraindication to cerebral MRI (e.g., pacemaker)

DEFLECT III Procedures & Assessments Screening Procedure Post-Procedure 30 days 4±2 days ̴30 days NIHSS mRS Neurocog* TAVR ± TriGuard DW-MRI NIHSS mRS Neurocog* DW-MRI NIHSS mRS Neurocog* *Neurocognitive test battery includes the Montreal Cognitive Assessment (MoCA) and computerized CogState Research Test. Baseline and 30-day evaluations include supplemental Digit Symbol Substitution, Trailmaking, and Word Fluency Tests.

DEFLECT III Endpoints Primary Safety Endpoint (ITT population) In-hospital MACCE defined as the composite of death, stroke, life-threatening or disabling bleeding, AKI (2/3), and major vascular complications (VARC-2) Secondary Performance (ITT population) Technical success: successful positioning (complete 3-vessel coverage verified by angiography) and retrieval without TAVR interference Secondary Efficacy (ITT and Per Treatment* populations) DW-MRI: Frequency, number, and average single, maximal, and total lesion volumes by DW-MRI at 4+2 days (range 2-6 days) Neurocognitive: Postoperative and change from baseline to postprocedure and 30 days *Per treatment (PT) population: subjects with complete TriGuard cerebral vessel coverage throughout the procedure (core lab adjudicated)

DEFLECT III Patient Disposition Intent To Treat Population N=83 Embolic Protection (TriGuard) n = 45 Unprotected TAVR (Control) n = 38 MRI Loss to FU n=13 (29%) Stroke n=1 Refused n = 3 PPM n=9 MRI Loss to FU n=13 (34%) Death n = 2 Stroke/PPM n=1 Refused n = 4 PPM n=6 In-hospital FU Safety n = 45 DW-MRI: n = 32 (71%) (ITT) n = 26 (57%)(PT) In-hospital FU Safety n = 38 DW-MRI: n = 25 (65%) (ITT) n = 25 (65%) (PT)

DEFLECT III Trial Organization Principal Investigators Alexandra Lansky, MD Andreas Baumbach, MD Yale University School of Medicine,USA Bristol Heart Institute, UK Szilard Voros, MD (Director) Global Institute for Research, Richmond, VA, USA Ecaterina Cristea, MD (Director) Helen Parise, PhD Yale University School of Medicine, New Haven, CT, USA (Statistics) Adam Brickman, MD (Director) Kevin Abrams, MD (chief) Columbia University, New York, USA Baptist Hospital, Miami, Fl Michael Cleman, MD (Chair) Joseph Brennan, MD John Forrest, MD Abeel Mangi, MD Yale University School of Medicine, New Haven, CT, USA Genae International, Inc. Harvard Clinical Research Institute MRI Core Lab Angiographic Core Lab Biostatistic Neurologic & neurocognitive Assessment Clinical Events Committee Monitoring, Site Mgmt. Data Mgmt

DEFLECT III Trial – Enrollment Highlights Feb 26, 2014 March 4, 2015 April 4, 2015 RCT Enrollment Complete Enrollment Start 30 day FU Complete 5 Countries / 13 Centers Joachim Schofer (17) Hamburg, Germany Andreas Baumbach (8) Bristol, United Kingdom Martine Gilard (2) Brest, France Didier Tchetche (13) Toulouse, France Daniel Blackman (6) Leeds, United Kingdom Thomas Modine (1) Lille, France Pieter Stella (11) Utrecht, Netherlands Gil Bolotin (4) Haifa, Israel Michael Haude (1) Neuss, Germany Thomas Cuisset (10) Marseille, France Med Spitzer (2) Dresden, Germany David Hildick-Smith (1) Brighton, United Kingdom Jochen Reinöhl (10) Freiburg, Germany

Baseline Clinical Characteristics ITT population TriGuard N=45 Controls N=38 P value Age (y) ± SD 82.7 ± 6.5 82.5 ± 5.9 0.62 Male 40.9% 50.0% 0.41 STS Score 4.7 7.4 0.48 EuroSCORE II 10.1 0.66 NYHA Class I or II (%) 83.3% 78.9% 0.65 III or IV (%) 45.0% 37.8% 0.85 A Fib on admission 22.0% 36% 0.36 CKD 25.0% 26.3% 0.89 COPD 31.8% 32.4% 0.95 O2 Dependent 6.8% 0.0% 0.10 Previous stroke/TIA 14.0% 18.4% 0.58 Frailty 11.9% 0.42 Porcelain Aorta 4.5% 0.18

*Direct Flow; **Lotus Valve Procedure Details ITT population TriGuard N=45 Controls N=38 P value General Anesthesia 76.7% 76.3% 0.96 Valvuloplasty Pre-TAVI 61.1% 70.4% 0.45 TAVI Implants n=44 n=37 CoreValve 31.8% 26.3% 0.59 Edwards Sapien/3/XT 63.6% 65.8% 0.84 Other* 2.3%* 5.3%** 0.47 Total Fluoro time (min) 28.2 18.6 <0.001 Total Contrast (ml) 165.8 138.6 0.16 Adjunct Pharmacology ASA + clopidogrel 69% 67.6% 0.89 ASA only 16.7% 16.2% Clopidogrel only 11.9% 8.1% 0.58 Warfarin 18.9% 0.39 *Direct Flow; **Lotus Valve

Device Performance ITT population TriGuard % (n/N) N=45 patients N=46 devices* 95% CI Technical success (composite): 87 (40/46) [68.6, 92.2] Successful deployment 93.5 (43/46) [82.1, 98.6] *Successful positioning (complete 3-vessel coverage until final valve deployment of first valve, verified by QCA) 87.0 (40/46) [73.7, 95.1] Successful retrieval 100 (46/46) [88.5, 99.9] Device interference (with TAVI system) 0 (0/46) [0.0, 7.7] Device Failure [0.1, 11.5] *One subjects had 2 TriGuard devices used (valve in valve case) *Per Treatment Population: excludes 6 patients with incomplete cerebral coverage

In-hospital Safety Outcomes (ITT) ITT population TriGuard % (n/N) Controls Relative Risk [95% CI] Hierarchical Composite In-hospital MACCE 22.2 (10/45) 31.6 (12/38) 0.70 [0.34, 1.45] Death 2.2 (1/45) 5.3 (2/38) 0.42 [0.04, 4.48] All stroke Life-threatening bleed AKI (Stage 2/3) 0 (0/38) 2.54 [0.11, 60.7] Major vascular comp. 15.6 (7/45) 15.8 (6/38) 0.99 [0.36, 2.68] Non-hierarchical components 4.4 (2/45) 0.84 [0.12, 5.71] 7.9 (3/38) 0.28 [0.03, 2.60] 17.8 (8/45) 21.1 (8/38) 0.84 [0.35, 2.04] TAVR Device Success (VARC-2 Composite) 97.8 (44/45) 94.7 (36/38) 1.03 [0.95, 1.13]

DW-MRI Results – Single and Max Lesion Volume Average # of new lesions/pt: 4.5 vs 4.0 for TG and Controls Protection has lower SLV and MLV 19% Better Median Lesion Volume (mm3) 45% 19% 41% 32 25 32 25 26 25 26 25 Intention to Treat Per Treatment

DW-MRI Results – Patients with No Ischemic Brain Lesions Protection has more freedom from ischemic lesions 55% 42% Better 32 25 26 25

DW-MRI Results – Percent of patients based on Total Lesion Volume (mm3) (PT) P=0.06 for trend Better Percent of patients 55% 58% 78% 1-50 51-150 >150 mm3

DW-MRI Results – Frequency of Patients with No Ischemic Brain Lesions Sapien CoreValve ITT PT ITT PT Better P int.=0.08 Percent of patients N=18 N=14 All Sapien n=37 Sapien 3 N=22 All Sapien n=35 Sapien 3 N=22

Clinical Efficacy Outcomes – NIHSS and MoCA Protection had fewer strokes and better cognitive outcomes Patients with worsening NIHSS and MoCA from baseline to discharge Worse 2/41 5/35 5/35 NIHSS MoCA

MoCA Score –Change from Baseline to Discharge (ITT) Protection prevents a decline in cognition at discharge Better Age Adjusted

Clinical Efficacy: CogState-Test Results (PT) Protection is associated with improved short and delayed memory at discharge Short term memory test Delayed memory test p=0.043 p=0.028 Age Adjusted

Conclusions Use of the TriGuard was safe and provided complete cerebral coverage in 87% of cases TriGuard protection increased the proportion of patients completely free of ischemic brain lesions by more than 50% and reduced single and maximum lesion volume by about 40% TriGuard appears to prevent cognitive decline and was associated with improved short-term and delayed memory at discharge compared to controls Stroke was under-reported based on systematic NIHSS assessment Protected patients had a 10% absolute lower stroke rate DEFLECT III provides proof of concept of the benefits of neuroprotection with the TriGuard device during TAVR and will benchmark event rates for a planned definitive randomized US approval trial

Death Events Event Arm Time to Event (days) Comment Cardiovascular Death Control Following BAV, transfemoral placement of Edwards valve immediately followed by pericardial effusion. Sternotomy and circulatory assist performed, followed by evidence of Ao ring rupture. Following BAV, hemodynamic instability with suspicion of Ao ring rupture. An Edwards valve was implanted prior to pt. death. TriGuard 14 Subject with disabling ischemic stroke. Primary cause of death: pneumonia, contributing causes: cerebral multi-infarct syndrome, vascular disease and COPD.

Neurological Events Event Arm Time to Event (days) Comment Ischemic Stroke, Non-disabling Control 1 MDT CV implanted too deep → manipulation prior to implantation. Post TAVI blurred vision, slurred speech. Resolved at 30 D F/U. Stroke, Undetermined, Non-Disabling 2 Edwards valve. 2 days following TAVI changes in visual field were reported. Subject was unable to fix gaze at times. Neurological consult performed. MRI not performed. TriGuard TriGuard maintained position, 3/3 vessels covered. Presentation included slurred speech, right sided weakness. At one month was still under neurology team care but residing at home. Disabling TriGuard lost position during TAVI with 0/3 vessel coverage. Prior existing TAVI device, Edwards implant. Bilateral ischemic stroke (anterior and posterior) confirmed by MRI/CT. NIHSS: 30, MRS: 5. Subject died of pneumonia day 14.

AKI Event rates in DEFLECT III compared to Literature 1.Takagi H, Int J Cardiol. 2013;168:1631-1635; 2. Konigstein M, Am J Cardiol. 2013; 3. Sinning JM, JACC Cardiovasc Interv. 2010;3:1141-1149; 4. Gebauer K, International journal of nephrology. 2012;2012:483748; 5. Smith CR, N Engl J Med. 2011;364:2187-2198; 6. Leon MB, New England Journal of Medicine. 2010;363:1597-1607; 7. Adams DH, N Engl J Med. 2014;370:1790-1798; 8. Popma JJ, J Am Coll Cardiol. 2014;63:1972-1981; 9. Najjar Expert Rev Cardiovasc Ther. 2015;13:301-316; 10. Leon MB, J Am Coll Cardiol. 2011;57:253-269; 11.Kappetein AP, J Am Coll Cardiol (In Press). 2012

Reporting Stroke: What if we ask Neurologists ? Prospective evaluation of pts undergoing surgical AVR Pre and post assessment and DW MRI Clinical strokes in hospital: 17% Moderate/severe: 4% TIA 2% Silent infarcts on MRI: 54%