Post Deflection Acceleration

Slides:



Advertisements
Similar presentations
Using an Oscilloscope Electricity Lesson 12. Homework Revise for the exam! Make revision check lists (lists of definitions, equations, derivations), make.
Advertisements

Form 5 Physics Next > The study of matter Chapter 4: Electronics 1.
Instrumental Chemistry
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Electron Optics.
Cathode Ray Tubes and their Uses.
POTENTIAL GRADIENT & CATHODE RAY TUBE
4.6.CATHODE RAY OSCILLOSCOPE Ambar Sarup. What is a Cathode Ray? A cathode ray is a beam of fast flowing electrons.
Thermionic emission If a tungsten filament is heated to about 2000 o C, some of the electrons have sufficient kinetic energy to escape from the surface.
Magnetic Field Patterns
Example: A negatively charged rod, of length l, has a total charge Q and is a distance b from a point P. The charge is uniformly distributed along the.
Electrons The discovery of the electron was a landmark
Medical Oscilloscopes. Cathode ray oscilloscope (CRO) basics: –Many measurement are made easier by the CRO because it will display not only amplitude,
CATHODE RAY TUBE.
Oscilloscope. 1.Electron guns 2.Electron beams 3.Focusing coils 4.Deflection coils 5.Anode connection 6.Mask for separating beams for red, green, and.
OSCILLOSCOPES Introduction The Cathode-Ray Tube
Unit 9 Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Screen Monitor Visual display unit (VDU)
EET 450 – Advanced Digital Video Display Systems.
Day 19: Electrostatic Potential Energy & CRT Applications
Electron Emission Introduction The reader is familiar with current conduction (i.e. flow of electrons)through a conductor. Examples are: current through.
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
Electron Microscopy.
Electrons Thermionic Emission
Experiment Number 2 Oscilloscope Dr. Amr A. Abd-Elghany Medical Equipment Technology Department.
ECE 5th SEMESTER Subject Consumer Electronics (CE)
Ch. 2 – Anatomy of the X-ray Machine
Electric Potential, Electric Energy and Capacitance
The Electron Gun Learning Objective:
Electrostatic Deflection and Focus Control.  The cathode ray tube consists essentially of an "electron gun" for producing a beam of rapidly moving electrons.
Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.
Introduction to Graphical Hardware Display Technologies
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Electron beam machining (EBM) – MM461 Dr. Dermot Brabazon Sch. Of Mech. and Manu. Eng. Dublin City University.
ELECTRON BEAM WELDING The electron beam gun has a tungsten filament which is heated, freeing electrons. The electrons are accelerated from the source with.
TELEVISION CAMERA TUBES
Thermionic Valves.
Oscilloscope The main purposes of the oscilloscope are: Can view the input waveform voltage or current. Can measure instantaneous values of the input waveform.
4.5 ELECTRON BEAMS ELECTRONS AND ELECTRONICS. Electron Beams Given enough energy, electrons can escape from a conductor and move through a vacuum space.Beams.
20-Jan-16 cathode ray oscilloscope. 20-Jan-16 tube photograph.
The filament is a heated wire from which electrons are emitted. Anodes attract the electrons produced at the filament and accelerate them. X plates deflect.
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
5.5 Electric Field and Voltage – Uniform Field p. 200 Electric Field and Voltage – Uniform Field A small test charge will experience a constant force anywhere.
An introduction to the OSCILLOSCOPE and its uses Colin G4GBP.
Electrons Thermionic Emission
Residential Audio & Video Systems Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Presentation 9 – Home Theater Video Display Systems.
1.  The primary output device in a graphics system is a video monitor. These monitors are based on Cathode Ray Tube (CRT) design.  CRT is a vacuum tube/electron.
PICTURE TUBE. ELECTROSTATIC FOCUSSING The electric field due to the positive potential at the accelerating grid extends through the opening the of the.
As Unit 1 - Electricity What you need to know..  Current is the rate of flow of charged particles.  In metals these are conduction electrons, most electrons.
Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the basic parts.
DONE BY : RAWDA ALNWAISEH BAYAN TALEB
The Cathode Ray Tube Monitor
Presentation of cathode ray oscilloscope
ELECTRONIC DEVICES AND CIRCUITS
Laboratory equipment Lecture (3).
Oscilloscope.
cathode ray oscilloscope
Electronic Instrumentation CATHODE RAY OSCILLOSCOPE (CRO)
X-ray Production Sharif Qatarneh Medical Physics Division
IMAGE ORTHICON.
Oscilloscope and its applications
Chapter 23 ELECTRONICS.
PRODUCING AND USING STREAMS OF ELECTRONS
Displays and Framebuffers
CATHODE RAY TUBE.
Electrons Thermionic Emission
Chapter 2 Overview of Graphics Systems
CATHODE RAY TUBE By Dr. Vaibhav Jain Associate Professor, Dept. of Physics, D.A.V (PG) College, Bulandshahr, U.P., India.
Parts of a cathode ray tube
Presentation transcript:

Post Deflection Acceleration Measurements & Instruments Post Deflection Acceleration By : Anan Ashour

The amount of light given off by the phosphor screen depends on the amount of  energy that is transferred to the phosphor by the electron beam. If the electron beam is to be deflected at a rapid rate, allowing the oscilloscope to respond to fast occurring events, the velocity of the electron beam must be great otherwise, the light output will drop off. For a fast oscilloscope it is desirable to accelerate the electron beam to the greatest amount possible, while on the other hand the greater electron beam velocity will make it more difficult to deflect the beam. The greater the accelerating potential the more difficult it is to deflect the electron beam.

This would require higher deflection voltages, but, more important, because the voltage is higher the time change of voltage, that is, dV/dt, is also greater. This would require not only higher voltage for deflection but higher currents to charge the capacitance of the deflection plates. This becomes a very significant problem for high-frequency oscilloscopes with frequency responses greater than 100 MHz. Modern cathode ray tubes use a two-step acceleration to eliminate this problem : First : Scan Expansion Mesh the electron beam is accelerated to a relatively low velocity through a potential of a few thousand volts. The beam is then deflected and, after deflection, is further  accelerated to the desired final velocity. The amount of acceleration after the deflection does not affect the deflection sensitivity. This type of cathode ray tube is called the post deflection acceleration tube

Mesh-less Scan Expansion Post deflection Acceleration CRT

Post deflection acceleration cathode ray tube using a mesh that further increases the amount of the electron beam scan. The electron beam is accelerated and deflected. However, the beam is further  accelerated through a very high potential of 10,000 V or more, after the deflection, so it does not have-an effect on the deflection sensitivity. A metallic mesh is balanced in the electron beam, and acts as a magnifying lens that causes the deflection to be further increased, which improves the deflection sensitivity. With this technique, deflection sensitivity can remain on the order of 5 to 50 V/cm even though the total electron beam acceleration is more than 10,000 V.

Disadvantages: The mesh tends to defocus the electron beam and make the spot broader than it would be without the mesh interfering with the beam. Second, the mesh conducts some of the electron beam away from the screen. This results in a reduced beam current and thus reduced spot intensity. The problem is not unique to the mesh, is that the electron beam tends to be defocused in the vicinity of the deflection plates owing to repulsion from charge distributions within the tube.

Second : Scan Expansion Mesh-less Several recent advances in cathode ray tube design have eliminated the mesh and alleviated these problems, thus producing a high-performance electron gun for use in high-frequency cathode ray tubes. The electron beam is generated from a conventional heated cathode surrounded by the control grid. The accelerating anode and two focus electrodes follow and provide focus, as well as the first accelerating voltage.

Mesh-less Scan Expansion Post deflection Acceleration CRT

These focus electrodes different from the cylindrical elements used in the conventional tube in that they are constructed from individual metal wafers with non-cylindrical holes in the center. This allows for a different focusing characteristic in the horizontal plane and the vertical plane, typically divergent in one plane being convergent in the other. The holes in the center of the metal wafers can be formed with greater precision than in a formed cylinder, and thus greater tolerances can be achieved at a lower cost. After the two focusing electrodes, the beam passes through the vertical deflection plates. The beam at this point is not fully focused, which decreases the amount of beam distortion due to the internal charge distributions.

The beam will be further focused after deflection to provide: a fine spot. After vertical deflection, the beam passes through a scan expansion lens that increases the amount of beam bending in the vertical plane. The beam is then deflected in the horizontal direction and passed through another  electron lens, which provides additional focusing. The beam is accelerated to the final velocity by a quadrupole lens, which provides not only an increase in electron velocity, but adds to the scan angle (scan expansion, which is similar to the mesh ) without distorting or defocusing the electron beam. The result of this design is increased deflection sensitivity, typically 2.3 V/cm for the vertical deflection and 3.7 V/cm in the horizontal direction. The difference between the vertical and horizontal deflection sensitivities is due to the fact that the vertical deflection occurs at a lower beam velocity.

Because the horizontal deflection of the oscilloscope involves only a time linear  sweep, while the vertical deflection requires complex waveforms, the more sensitive deflection should be reserved for the vertical direction. Using the mesh-less electron gun, 100-MHz plus oscilloscopes can be constructed with integrated circuits using only 40 or 50 V or even less for deflection. The mesh-less tube is being considerably shorter, results in smaller and lighter  oscilloscopes for laboratory and portable use

Welcome