NEW OIL REGENERATION PLANT

Slides:



Advertisements
Similar presentations
High performance; from 1 metric ton to 100 metric tons instant purification facility per hour, 2400tons per day Low energy consumption (25 kw/h – 38 kw/h)
Advertisements

Condition Monitoring Of High Voltage Machines By The Analysis of
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Stem Challenge Energy management systems, CHP, Harvester tank, green roofs and underfloor heating. 1.
OPEX Savings Utilizing Filtek Technology. Agenda 01 Introduction: What does Filtek Offer? 02 Why Service the Generator every 250 hours? 03 What is Filtek.
FoamPro 1600 Series Fully automatic Class A foam ONLY
PARKER BOILER PARKER BOILER HOT WATER PIPING SYSTEM 1. 3 way valve and O.S.A. reset. 2. Single boiler piping schematic. 3. Single boiler with 3 way valve.
FIRE Safety Solutions Dr. Pulak De FIGHT FIRE WITH KNOWLEDGE.
1 Oil Fuel Line De-aerators What they are, what they do and how to install.
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Bereichskennung oder Produktname Process Instrumentation and Analytics Januar, 2003 Folie 1 A&D PI2 SE1 Siemens Process Analytics in the Cement Industry.
GENERAL IDEAS IN AIR POLLUTION CONTROL
The SR Scale Remover For Cooling Water Treatment Without Chemicals.
We turn the AIR into a TOOL MOTOR BLOWER BASEPLATE Commonly used Nantong motor Imported from France Made in Taicang factory.
SINGLE-PHASE HOPPER LOADERS ENG. FEEDING SINGLE-PHASE FEEDER 2.
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Hydraulics For The Long Term
ENGINEERING YOUR SUCCESS. PDF Market and Sales Meeting Refrigerated Dryers.
Metallic phosphoric acid heaters in place of graphite block heaters Vincent PERROT1 SYMPHOS 2013 in AGADIR Morocco.
Lease Automatic Custody Transfer
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
Plan 2 – Dead-end Seal Chamber Optional Jacket
How to make “Touch Free” washing clean better. RYKO Manufacturing Company.
ON LINE TRANSFORMER OIL REGENERATION PROCESS OF GT-8
Base Oil Recovery System-OilPure for Recovery and Reuse of oils. Pure Tech India, A-5, Trec step, Thuvakudi, Trichy Telephone: ;
What is BioFlo? BioFlo is a paraffin and asphaltene solvent and inhibitor for oil and gas wells, pipelines, and refineries. BioFlo has many advantages.
(U-shaped tank) WATER TANK SLUDGE TANK This system makes it possible to recover the liquid part of the suctioned material in the sludge compartment.
SETA Water treatment plant maintenance
“PCA” – Polyclean Applicator the patented application system
Claudio Bortolin. 1 st June: PT100 electrical connection failure (Temp Chiller water In&Out) 1) it required an access to the cavern to be fixed 2) access.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans S. Pordes Argon Purity1Integrated R & D Plan Review.
J. Direito - M. Battistin – 28 th May 2010EN/CV/DC J. Direito, M. Battistin (EN/CV/DC) 28 th May 2010 Detector Cooling Project III Thermosiphon Workshop.
Sulfur Hexafluoride (SF6) Gas Handling. Description Sulfur hexafluoride (SF6) in its pure state is inert, nontoxic, odorless, nonflammable and colorless.
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
AIR POLLUTION PREVENTION AND CONTROL
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Open-loop control system Closed-loop control system
An Ice Blaster is a Portable Machine which Uses CO 2 Pellets to Clean Energized Equipment Power Source is a 120V Generator and Diesel Powered Air Compressor.
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
TS-CV-Detector Cooling 22-Jan-04P. Tropea - JCOV1 Design, construction and installation of a double loop fluorocarbon 150 kW cooling plant for the CMS.
9th CII EXIM Bank Conclave India-Africa Project Partnership
Wednesday – starboard side engine room weekly checks Cycle all valves on the starboard side of the engine room Check all systems, connections, valves,
Innovation quality reliability Komara 7 Skimmer System (Formally Komara Mini) December 2015.
P RODUCTS AND SOLUTIONS Dew International Business Consultants 1.
Kaeser Rotary Screw Vacuum Packages
2 nd presentation by Patricia REVERSE OSOMOSIS :the possible solution for water hardness.
Bernard Boutherin 1 Feedback after four years of operation.
(Formally Kormara Midi)
TECHNICAL PRESENTATION OF RTSSL POWER CRUISE POWER STEERING FLUID.
June 25, 2016 Centri-MAX10 Centrifugal Absolute Oil Cleaning System.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
Md.Hamidul Haque ID: Prog:BSEEE SEC:E/3 International University of Business Agriculture and Technology (IUBAT )
© Alfa LavalSlide 1 Alfalaval oil&coolant cleaning 절삭. 측정. 전동공구. 수입공구. 용접기자재. 잡자재 일절 경남 마산시 봉암동 산업용재백화점 141 호 Tel
VMCL ELECTRONIC DIVISION.
The New C55* CPVSd 10-20hp People. Passion. Performance.
Friday – port side engine room weekly checks
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
High Quality Ammonia purifier for Refrigeration Plants | Maniks
Application Operation principle Advantages Highlights Comparison
SB Packing Automatic Downpuller Power Unit
High Pressure screw compressor
August 23, 2000 R.N. Dubois Dow Chemical
Trane Care Energy RTHD Adaptive Frequency Drive retrofit.
Leak Detection All Refrigerant: Soap bubble
Treatment –Reverse Osmosis (Desalination)
Solstice - Filtration System
Sludge Dewatering Filter Press Controls Upgrade at SSWRF
ECV- VACUUM 7.2 KW URBAN Friendly Compact in Size 130 mm 240 L 20 L
Presentation transcript:

NEW OIL REGENERATION PLANT WITH REACTIVATED FULLER’S EARTH 1

Oil regeneration with reactivated Fuller’s Earth Applications: Reduction in oil acidity from 0.4 mg Koh/gm to 0.03 mg Koh/gm. Advantages: The same quantity of Fuller’s earth can be used >300 times due to the unique reactivation process. 2 2

Benefit of the oil regeneration process compared to conventional purification system. Remove contaminants such as acids, sludge, anilines and decaying products. Improve color, oxidation stability, Interfacial tension and power factor Extend the oil life-time cycle Extend more significantly the life-time cycle of power transformers (with regular regeneration treatment) 3

Strengths & Weaknesses of the different solutions to solve acidity Change the oil to a new or reclaimed oil No specific equipment required: (oil pump, oil treatment plant, tank,..) No graduate people required Power shutdown Subject to new oil price $$$$$ or difficult to find reclaimed oil. Old oil has to be disposal or resale for third applications at very low price. Short term solutions, no clean out of the transformer. Several people requested Regenerate the oil No power shutdown during regeneration process Short pay back return No oil to eliminate No subject to oil price fluctuation or shortage Clean out the transformer Specific equipment required Not a lot of equipment available Graduate people required 4

Main differences between both solutions to regenerate dielectric oil Regeneration with disposable Fuller’s earth Regeneration with reactivated Fuller’s earth Oil losses 6% 0,4% Fuller’s earth losses 100% 0,01% by reactivation (limit 70% before replacement) Tasks Replacement of Fuller’s earth at saturation Replacement almost once a year Workforce Several people to handle operations One people for normal operations Few people for Fuller’s Earth replacement. 5

ARRAS MAXEI Advantages -More than 60 years of experience in oil treatment plant manufacturing -Manufacturing complying with CE regulation standards -On going Research and Development Improved reactivation control New column design Friendly touch control panel -Reliable and convenient after sales service 6

ERP 5000 SINGLE PASS QUALITY Oil test results (general) TEST DESCRIPTION METHOD UNIT INITIAL OIL CONDITION ERP 5000 SINGLE PASS QUALITY GAS CONTENT GC %v/v 8 0,01 IFT ASTM Dynes/cm <15 >40 COLOR APPEARANCE -- Visual Brown/Cloudy Clear Light Yellow TAN DELTA (90°C) IEC 247 <0,01 <0,005 OXIDATION STABILITY IEC 74 164 HRS Depleted Restored MOISTURE IEC 733 ppm <200 5 BREAKDOWN VOLT IEC 156 kV <30 >75 ACIDITY IEC 296 mgKOH/gm 0,4 <0,03 7

ARRAS MAXEI Product range MAS 5000 ERP 6 Columns MAS 5000 ERP 9 Columns 12 Columns ERP Dual bank of columns Flow rate 5000 l/h Regenerated oil 2400 l/day 3600 l/day 4800 l/day Capacity x 2 Filtration 1µm absolute Treatment heating power 80 k W 80 kW Reactivation heating power 36 kW 54 kW 72 kW 3 kW per column Total heating power 116 kW 134 kW 152 kW Reactivation+ Treatment heating power Limit vacuum closed suction 0,5 mbar Vacuum in treatment (mbar) 0,5 to 5 Fullers earth quantity 600 kgs 900 kgs 1200 kgs Nbre columns x 100 kgs 8

Main Characteristics : Off-line or on-line treatment and regeneration Fully automatic control: -Continuous control of overpressures in the piping network. -Automatic foam regulation -Continuous control of overpressures, temperature, water content and filter clogging. -oil heating system. -Continuous control of the oil level in the transformer and plant -Buchholz control connected to plant PLC Double filtration: -7 µ absolute at the inlet -1 µ absolute at the outlet Connexions: - Special insulation valves with progressive opening at the transformer inlet and outlet -Transformer by-pass valve utilized during start up procedure. -Plant earthed to transformer earth strep. 9

Options: On-line water PPM measurement: Colour comparison control to launch the reactivation process Air conditioned for control room Remote control to GSM Network (Alarms or alarms and treatment parameters) Additional vacuum pump for transformer excavation DBPC injection system Cable reel 10

General layout 11

Container design for easy access and maintenance Presentation SKID SEMI TRAILER Container design for easy access and maintenance SEA CONTAINER (20’ OR 40’)° 12