Bead Normalization of Mass Cytometry Data and Mass-Tag Cellular Barcoding Rachel Finck May 7, 2014.

Slides:



Advertisements
Similar presentations
How to Get the Best Performance out of your CyTOF
Advertisements

Building a Panel Select markers Select conjugates Method to build panel performance criteria.
Imaging MS MIAPE Working Document Helmholtz Institute, Munich, April 16 th 2012.
Quality Control in Immunophenotyping Dr. N. Varma Prof. & Head – Hematology Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh.
Assays of Immune Function. Some Definitions BrdU: bromodeoxyuridine (incorporated into DNA during cell division) CBA: cytometric bead array DC: dendritic.
Advances In Flow cytometry Amina Kariminia Ph.D.
Vladimir I. Baranov, Dmitry R. Bandura, Olga Ornatsky
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Data analytical issues with high-density oligonucleotide arrays A model for gene expression analysis and data quality assessment.
Flow Cytometry and Sorting Part 2 Lecture Notes for “Fluorescence Spectroscopy in Biological Research” Robert F. Murphy, October 1996.
Introduction to Flow Cytometry
Proteomics Informatics Workshop Part III: Protein Quantitation
Fa 05CSE182 CSE182-L9 Mass Spectrometry Quantitation and other applications.
Thoughts on Biomarker Discovery and Validation Karla Ballman, Ph.D. Division of Biostatistics October 29, 2007.
Protein Arrays By: Nicole Therrien. Overview What Are Protein Arrays? General Scheme Types of Arrays ◦ Analytical  In-depth  Example ◦ Functional 
Antigen antibody reactions
Research Techniques Made Simple Flow Cytometry II: Mass and Imaging Cytometry Hung Doan 1,2, Garrett M. Chinn 3, Richard R. Jahan-Tigh 1,2 1 Department.
Quantitative PCR Analysis of DNA, RNAs, and Proteins in the Same Single Cell A. Ståhlberg, C. Thomsen, D. Ruff, and P. Åman December 2012
Causal Discovery from Mass Cytometry Data Presenters: Ioannis Tsamardinos and Sofia Triantafillou Institute of Computer Science, Foundation for Research.
Flow Data Analysis Challenges Deck from Amgen Attendees Bioinformatics/ Biostatistics Molecular Computational Biology Sciences John Gosink Cheng SuKatie.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Basic Principles in Flow Cytometry
Microarray - Leukemia vs. normal GeneChip System.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
High throughput Protein Measurement Techniques Harin Kanani.
BioChip Ventures Division a 3-Dimensional Microarray Substrate.
Role of gp130 Activation for HSC Self-renewal Aurore Degrange and Lisa Treat BE.400 Term Project December 10, 2002.
Potency Testing for an Autologous Cellular Immunotherapy Nicole Provost, PhD VP Product Development Dendreon Corporation February 9, 2006.
Sylvia K. Plevritis, PhD Professor Department of Radiology and
Quality Controls: Get your instruments under control!
Bayesian Networks and Flow Cytometry Paul McDonagh Bioinformatics and Computational Biology, Amgen Seattle.
Biological Evaluation Lecture - 3 Principles and Importance of BA’s Joseph O. Oweta B. Pharm (MUST)
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Flow cytometry data analysis: SPADE for cell population identification and sample clustering Narahara.
Altered B-cell receptor signaling kinetics distinguish human follicular lymphoma B cells from tumor-infiltrating nonmalignant B cells by Jonathan M. Irish,
Chapter 8 Introducing Inferential Statistics.
Multiplex analysis of cytokines Russell Garland KWS BioTest
Minimal Residual Disease (MRD) in Multiple Myeloma
Flowcytometry.
Development of Flow Cytometry Based Methods to Analyze Cellular Insulin Response Adetokunbo Martins, Byron Hetrick & Carrie McCurdy | Department of Human.
Mass Cytometry: Single Cells, Many Features
Volume 144, Issue 3, Pages e1 (March 2013)
Tiago R. Matos, Hongye Liu, Jerome Ritz 
Single-cell systems-level analysis of human Toll-like receptor activation defines a chemokine signature in patients with systemic lupus erythematosus 
Mass Spectrometry.
Single-cell systems-level analysis of human Toll-like receptor activation defines a chemokine signature in patients with systemic lupus erythematosus 
Flow Cytometry and Sorting Part 3
Improving T-cell expansion and function for adoptive T-cell therapy using ex vivo treatment with PI3Kδ inhibitors and VIP antagonists by Christopher T.
Volume 6, Issue 5, Pages e5 (May 2018)
Volume 65, Issue 2, Pages (January 2017)
Volume 160, Issue 1, Pages (January 2015)
Tiago R. Matos, Hongye Liu, Jerome Ritz 
Research Techniques Made Simple: Mass Cytometry Analysis Tools for Decrypting the Complexity of Biological Systems  Tiago R. Matos, Hongye Liu, Jerome.
Single-Cell Mass Cytometry Analysis of the Human Endocrine Pancreas
Volume 2, Issue 4, Pages (April 2016)
Volume 144, Issue 3, Pages e1 (March 2013)
Nachiket Shembekar, Hongxing Hu, David Eustace, Christoph A. Merten 
Flow cytometric characterization of γδ T cells in our patient demonstrates specific expansion of a homogeneous Vδ2+ T cell population. Flow cytometric.
CellTrace labeling of primary OT-I T cells allows for identification of OT-I nuclei after coculture. CellTrace labeling of primary OT-I T cells allows.
Volume 36, Issue 1, Pages (January 2012)
Vimentin is dispensable for multiple B cell–intrinsic processes.
Volume 118, Issue 2, Pages (July 2004)
Defining antigen-specific responses with human MHC class II tetramers
Senescence-associated defective HLA-DR upregulation does not modulate immunosuppressive properties of MSCs. (A) Fit and senescent MSCs were subjected to.
Marijn T.M. van Jaarsveld, Difan Deng, Erik A.C. Wiemer, Zhike Zi 
EV derived from mature BMDC are efficiently taken up by murine monocytes and have a rich content of CCF. EV derived from mature BMDC are efficiently taken.
by Matthew H. Spitzer, Pier Federico Gherardini, Gabriela K
ALT-803 stimulates proliferation and activation of human NK cells and T cells in vitro. ALT-803 stimulates proliferation and activation of human NK cells.
Volume 12, Issue 2, Pages (February 2019)
Arati Sridharan, Chetan Patel, Jit Muthuswamy 
Presentation transcript:

Bead Normalization of Mass Cytometry Data and Mass-Tag Cellular Barcoding Rachel Finck May 7, 2014

Measure by TOF Stimulate cells in vitro Crosslink proteins Stain with isotope tagged Abs Nebulize single-cell droplets Ionize (7500K) Permeabilize cell membrane E. Simonds CyTOF Acquisition Decisions are Hidden in the Details

Ion cloud splits into pushes before reaching the detector Each pulses, a.k.a. ‘push’, includes an entire mass spectrum A cell’s ion cloud will span ~20-60 pulses Single-cell events are interpreted by a post-processing peak detection step The data recorded for a particular mass in a given push is indicative of the number of ions reaching the detector during that metal’s time window within the pulse Ion Intensities and Pulse Counts of a Single Cell Push

Ease of Quality Assessment/Control Can Be Obfuscated by High-Dimensional Analyses vs. SPADE ViSNE Wanderlust CD3+ T cells CD4+T cells CD8+T cells

Ease of Quality Assessment/Control Can Be Obfuscated by High-Dimensional Analyses vs.

Outline –Normalization of Mass Cytometry Data with Bead Standards Review of normalization algorithm Demonstration of normalization software with updated beads –Mass-Tag Cellular Barcoding Dose response to inhibitors Single-cell deconvolution of barcoded populations “Doublet-free” barcoding scheme

Goal: Reliably compare mass cytometry data across patients, conditions, tissues, etc. Problem: Drifts in mass cytometry instrument sensitivity over time due to cellular debris, fluctuations in plasma temperature, and calibrations. Solution: Normalization using internal bead standards measured concurrently with cell samples. Normalization of Mass Cytometry Data

Before Normalization Signal Drift Across Multiple Conditions Measured in Human Bone Marrow Has Been Corrected Using Unstimulated Controls After Normalization Bendall, Simonds, et al., Science, May 2011 time

Internal Bead Standards Generalize Normalization Capabilities La139 Pr141 Tb159 Tm169 Lu175 Desirable Features for Internal Standard Independent of biological sample Not subject to variable staining Can be directly mixed with sample to monitor instrument sensitivity at all times beads were gift from DVS Sciences Metal-embedded polystyrene bead Span instrument mass and dynamic ranges Unique 5-element signature allows antibodies to be tagged with bead elements Ce140 Eu151 Eu153 Ho165 Lu175

cells beads Measure by TOF Beads can be spiked into standard mass cytometry protocol Stimulate cells in vitro Crosslink proteins Stain with isotope tagged Abs Nebulize single-cell droplets Ionize (7500K) Permeabilize cell membrane E. Simonds

Beads are Identifiable from Cells Even When Measured on Overlapping Channels No reduction in number of parameters since beads and element-tagged antibodies can be simultaneously measured on the same channel

Bead Smoothing Removes Local Variance (sec)

(sec) Bead Smoothing Removes Local Variance

Fitted Slopes Define a Correction Function (sec)

Fitted Slopes Define a Correction Function (sec)

Fitted Slopes Define a Correction Function (sec)

x Fitted Slopes Define a Correction Function (sec)

Fitted Slopes Define a Correction Function (sec)

4.9-fold mean range 1.3-fold mean range Normalization Reduces Bead Intensity Variation (sec)

Normalization Aligns Surface Marker Histograms Day A Day B Day C Day D Day A Day B Day C Day D CD4 in T-cellsCD8 in T-cells CD14 in Monocytes CD38 in Monocytes HLA-DR in Monocytes CD19 in B-cells 61.7% % 62.2% 61.8% 62.4% 61.5% 61.9% 62.3% 97.1% 98.0% 97.7% 98.2% 97.3% 97.8% 97.5% 98.1% 36.5% 35.8% 35.4% 34.7% 37.2% 34.8% 34.1% 34.7% 87.0% 87.8% 89.2% 88.8% 87.2% 87.4% 88.3% 89.4% 92.8% 97.3% 97.9% 97.6% 93.8% 96.7% 97.1% 97.2% 97.5% 98.5% 98.7% 98.6% 97.5% 98.5% 98.6%

Internal Bead-based Normalization Corrects Intra-File Decay 73% of initial intensity 98% of initial intensity

Multivariate Relationships are Preserved by Normalization Before After Pairwise Correlations Between Surface Markers in a Single File

4.1-fold mean range 1.2-fold mean range Normalization Reduced Non-Biological Variation in Primary Pediatric ALL Bone Marrow Samples

patient Normalization Reduced Non-Biological Variation in Primary Pediatric ALL Bone Marrow Samples

1. Adjust gates. 2. Approve gates. 3. Set bead removal threshold. Normalization Software Example Using New Beads

Normalization Software Reports Bead Intensity Ranges

Relative Bead Metal Intensities Vary Across Calibrations and Instruments Instrument 1 Instrument 2 Day ADay BDay ADay B time

Normalization Summary the intensities of the normalization beads quantitatively monitor instrument sensitivity over acquisition time the effects of instrument variation on mass cytometry data are reduced by a correction derived from internal 5- metal bead standards normalization allows for the direct comparison of samples collected from multiple individuals and treated under different conditions

Multiplexed mass cytometry profiling of cellular states perturbed by small- molecule regulators Bernd Bodenmiller*, Eli R. Zunder*, Rachel Finck*, Tiffany J. Chen, Erica S. Savig, Robert V. Bruggner, Erin F. Simonds, Sean C. Bendall, Karen Sachs, Peter O. Krutzik and Garry P. Nolan Nature Biotechnology September 10;30(9): Bernd BodenmillerEli Zunder

Cell Multiplexing/Barcoding Overview Advantages: 1.Uniform Staining 2.Reduced Antibody Consumption 3.Reduced Acquisition Time 4.Improved Singlet Detection Krutzik PO, Nolan GP. Fluorescent cell barcoding in flow cytometry allows high- throughput drug screening and signaling profiling. Nat Methods May;3(5):361-8.

Combinatorial Cell Labeling by DOTA-Maleimide Mass-Tag Cell Barcode (MCB) Reagents

7-metal Binary Cell Labeling Scheme for 96-well MCB Multiplexing 2 1 =2 2 2 =4 2 3 =8 2 4 = = = =128

Small Molecule Kinase Inhibitor Profiling Calculation of phosphorylation site dose responses to inhibitors after various stimulations in multiple cell types.

Small Molecule Kinase Inhibitor Profiling

18,816 measurements from a single multiplexed tube 2,352 dose response curves

Dose Response Curve Website

Anastassiadis et al. Comprehensive assay of kinase catalytic activity reveals features of kinase inhibitor selectivity. Nat Biotechnol Oct 30;29(11): How Does Our 96-well MCB In Vivo Analysis Compare to In Vitro Kinase Inhibition Assays?

PBMC In Vivo IC50s Strongly Correlate with In Vitro Percent Inhibition Values Anastassiadis et al. Comprehensive assay of kinase catalytic activity reveals features of kinase inhibitor selectivity. Nat Biotechnol Oct 30;29(11): Davis et al. Comprehensive analysis of kinase inhibitor selectivity. Nat Biotechnol Oct 30;29(11):

U. Toronto / DVS Sciences Scott Tanner Olga Ornatsky Vladimir Baranov Dmitry Bandura Tad George Columbia Dana Pe’er Smita Krishnaswamy El-ad David Amir Prof. Garry P. Nolan Sean Bendall Erin Simonds Astraea Jager Kara Davis Wendy Fantl Eli Zunder Bernd Bodenmiller Rob Bruggner Karen Sachs Greg Behbehani