TRACE-SAFE® Water Blocking Tracer Wire for underground utilities.

Slides:



Advertisements
Similar presentations
Metals All metals belong to one of these two groups.
Advertisements

Electrical Systems Conductors good electrical conductors.
Basic Electricity.
LIGHT-DUTY BELT FASTENER SYSTEMS
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
Electronics. Solid snap together electronic connectors.
Telecom Cabling Grounding and bonding.
Creating Static Electricity. Electrical Insulators Conductivity is the ability of materials to allow electrons to move freely in them Materials that hold.
Benchmark Companies Inc PO Box Aurora CO Conductors, Insulators, Semiconductors.
Guide to Network Cabling Fundamentals
Classes of transmission media
Rohrback Cosasco Systems, Inc.
Electricity.
Chapter 3Transmission Lines Why use high-voltage transmission lines? The best answer to that question is that high-voltage transmission lines transport.
TYPES OF METALS.
Bachelor of Technology Mechanical
Impact of Bonding Requirements for CSST on LP-Gas Piping Systems April 2009.
LOCALIZATION & RECTIFICATION OF OPTICAL FIBER FAULT
CHAPTER - 14 CHEMICAL EFFECTS OF ELECTRIC CURRENT
Transmission Lines …….. Conductor Material
Materials and Their Properties
BASICS OF ELECTRICITY Vocabulary Understanding of Layer 1 & Layer 2 Networking Professionals need a basic understanding.
CANKAYA UNIVERSITY OFFICE OF BASIC AND ELECTIVE COURSES -ENGLISH UNIT-
Types Of Metal. Pure metals -Single element metal -Mined from the ground -Natural metal -Examples -Copper, lead, aluminum, iron, tin, gold, silver, titanium,
Chapter 9 Characteristics of Metallic Materials. Objectives Four major classifications – ferrous,non ferrous, high temperature super alloy, and refractories.
I. Metallic Bonds  How atoms are held together in the solid form.  Metals hold onto their valence electrons very weakly.  Think of them as positive.
1 Cables A large portion of electrical signals are transmitted through solid electrical solid electrical conductors. A wire is a single conductor. A cable.
Gandhinagar Institute of Technology
Metals.  Properties of elements determine what we can use them for.  For example, tungsten has the highest melting point of any metal ( C) but.
IST 126 Computer Networks Spring, What is a Computer Network? A group of computers and other devices that are connected together in order to share.
OBJECTIVE  INTRODUCTION OF OPTICAL FIBER  CONSTRUCTION OF OPTICAL FIBER  PRINCIPLE OF OPTICAL FIBER  TYPES OF OPTICAL FIBER  OPTICAL FIBER FAULTS.
Dry type transformers Zaragoza Aluminum vs. Copper
This photograph of the tungsten filament from a light bulb was taken with a scanning electron microscope. The filament is magnified more than 100 times.
Chapter 15. Metallic Bonds Holds metals together by sharing the electrons (sea of electrons) VERY STRONG.
Daily Lesson Electrical Conductors Prepared by: Brian Alexander This lesson is from Virginia Tech and has not been edited by the Georgia Curriculum Office.
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
Electrical Systems Conductors good electrical conductors.
UNDERGROUND CABLE.
TOPIC 4 CHEMICAL BONDING AND STRUCTURE
Electricity Current and charge. Electricity The flow of an electrical current Electrons flowing from a negatively charged area to a positively charged.
1 Electricity. 2 Electrons + + Negative Charge ELECTRICITY comes from the electrons in an atom.
* Cars * Bicycles * Tools * Toys * Wires * Some metals are very hard and strong. * Metals conduct heat and electricity well.
Introduction to nonferrous metal and alloys
Electric Wiring Conductor A material that allows electricity to move readily and offers low resistance Example: copper, aluminum and water.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
Simple Circuits with Insulators & Conductors. S5P3 Determine the necessary components for completing an electric circuit. Classify common materials as.
Tinned copper wires over Bare copper wires. Bare copper wires are the most popular sets of copper used in electrical and mechanical circuits. They are.
Cable 101 The basics of wire & cable ©Copyright 1997, Belden Inc.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Q: Where do we obtain most of our metals from?
Electrical Systems Conductors good electrical conductors.
Metals All metals belong to one of these two groups.
Grounding the Electrical System
Electrical Conductors
Conductors are materials in which electrons can move easily.
AHMEDABAD INSTITUTE OF TECHNOLOGY
Metals All metals belong to one of these two groups.
BROCHURE & PRODUCT DETAILS
Metallic Bonds are… How metal atoms are held together in the solid.
Grounding the Electrical System
Metals All metals belong to one of these two groups.
Electronics Fundamentals
Govt. Polytechnic,Manesar
Metals.
CONDUCTING Materials.
Chapter 6: Mechanical Properties of Metals
ELECTRICAL INSTALLATION
CST 450 Flare Stack Cable High Temperature, Fire resistant, High Voltage Single Conductor.
Make a Complete Circuit
Presentation transcript:

TRACE-SAFE® Water Blocking Tracer Wire for underground utilities. A Chase Corporation Company

NEPTCO – Who are we? Subsidiary of Chase Corporation (NYSE:CCF) NEPTCO established 1953 Headquarters in Pawtucket, RI Key markets served Telecommunication / Underground Utilities TRACE-SAFE®, MULETAPE®, Detectable MULETAPE® Wire & Cable, Fiber Optic Cable Systems NEPTAPE® Shielding Tapes for copper cables LIGHTLINE® & FLEXLINE® strength elements for FO cables Electronic Packaging COVERTAPE & WAFERTAPE®

What is TRACE-SAFE® ? TRACE-SAFE is a high strength, water blocked, easy to install and locate tracer wire. Per Consolidated Edison, “TRACE-SAFE is the 21st century technology in tracer wire”. TRACE-SAFE is your best option for any tracer wire application. Why?...

Why TRACE-SAFE® ? Tracer wire is often damaged during installation or in service. All conventional tracer wires consists of a single conductor protected by a single insulation. The slightest void in the insulation creates a water path that leads to shorting while locating and corrosion. In many cases splicing methods are not durable enough. There are no universal standards for tracer wire or connectivity. This leads to variability and inconsistent locating results. TRACE-SAFE multi-layer construction and simple to use reliable connectors address concerns that lead to tracer wire failure.

NEPTCO Listens to Customers TRACE-SAFE was designed to outperform the competition in the following areas: Corrosion resistance Strength Handling Abrasion, crush & impact resistance Lightning Connectivity Locating TRACE-SAFE is setting the standard by providing solutions. Third party testing includes a report from the Gas Technology Institute and other industry experts.

See the difference!

4 Levels of Protection Against Corrosion TRACE-SAFE stops water penetration before it can get to work destroying your tracer wire. Tin plating PE insulation on the conductor Water blocking yarns 30 mil HDPE overall insulation TRACE-SAFE passes telecom industry standard 3-meter water head test. Required by Verizon , ATT and most underground fiber optic cables. Salt spray corrosion testing confirms tin plated copper is superior to copper and CCS tracer wires. (ASTM B117-03 Salt Spray Accelerated Test)

Strong & Light Weight Tensile strength of 1,800 lbs. 12 ga. extra high strength CCS = 1120 lbs. 10 ga. hard drawn solid copper = 462 lbs. Retains full strength after being kinked. GTI simulated kink test or wrapping wire around a nail. TRACE-SAFE = 1,800 lbs. 12 ga. Extra high strength CCS = 440 lbs. 10 ga. Hard drawn solid copper = 443 lbs. TRACE-SAFE weighs only 20 lbs./mft. 12 ga. Extra high strength CCS weighs 26 lbs./mft 12 ga. Solid copper weights 29 lbs./mft

Handling TRACE-SAFE is user friendly… Flexible No spring back Stays where it’s put No wire stripping No special tools required

TRACE-SAFE is durable in service! Abrasion tested by GTI, TRACE-SAFE outperforms the closest competitor by almost double. (ASTM 4373) TRACE-SAFE survives potential damaged caused by crushing and impact during installation. (UL1581) It takes less than 500 lbs. of pressure to compromise the insulation of a conventional tracer. A 5 lb weight, dropped from 24” above a conventional tracer wire will split the insulation. And what about TRACE-SAFE? It’s takes over 4,000 lbs. of pressure and the drop test does not breach the insulation.

UL 1581 in Action The Rock The Rock in Action 12 awg Cu. Wire Exposed

TRACE-SAFE® DOES NOT TRANSMIT LIGHTNING! If struck by lighting the 19 gauge copper wire will disintegrate at the point of the strike. The current will not travel down the tracer damaging your pipe as shown below. Plastic pipe using standard tracer after lightning strike

TRACE-SAFE® Locating System In the same way as, “ a chain is only as strong as it’s weakest link”, one bad connection can disable your tracer wire system. TRACE-SAFE connectors provide “consistent” terminations. Insulation displacement connector technology Gel filled and corrosion resistant Safe, fast and reliable way to splice or terminate your tracer wire Eliminates wire stripping Any connection can be made in seconds. No special tools required Connectors available for all situations End to End Splices Main line to lateral splice Locating clip Integration to your existing tracer wire

TRACE-SAFE® Locating System End to End Main to Lateral Locating Clip

Locating With TRACE-SAFE® TRACE-SAFE locate ability is equal to or better than conventional tracer wires, using standard locating equipment and techniques. (chart next slide) Easily located at lower frequencies.

TRACE-SAFE® = Accurate Locating Electrical Conductivity of Materials* Silver 105% Copper 100% Gold 70% Aluminum 61% Brass 28% Zinc 27% Nickel 22% Iron 17% Bronze 7-15% Lead 7% Steel 3-15% *International Annealed Copper Standard TRACE-SAFE Other than silver, copper is the BEST conductor to use in a tracer wire! Copper Clad Steel

NEPTCO Water Blocking Tracer Wire-The Superior Alternative NEPTCO RT1801W FAR END GROUND 12 AWG Cu RT1801W is a superior locating means: 2. Far end ground provides best results. A) 9.5 KHz, with far end ground 3. 512 Hrz signal is weak, far end ground Directional Boring & Locate Trials performed at: B) 38/80 KHz with or without far end ground improves locate performance. Staking University|Manteno,Illinois|Mike Parilac--President

NEPTCO Water Blocking Tracer Wire-The Superior Alternative NEPTCO RT1801W NO FAR END GROUND 12 AWG Cu RT1801W is a superior locating means: 2. Far end ground provides best results. A) 9.5 KHz, with far end ground 3. 512 Hrz signal is weak, far end ground Directional Boring & Locate Trials performed at: B) 38/80 KHz with or without far end ground improves locate performance. Staking University|Manteno,Illinois|Mike Parilac--President

TRACE-SAFE® Advantages TRACE-SAFE , one product, for all applications. Open trench, directional boring, pipe bursting Unmatched performance delivers savings during installation and in service. High Strength Corrosion resistant Impact, crush & abrasion resistant Lightning protection TRACE-SAFE connectors Faster and safer to install Gel filled , no stripping, works with your existing wire. Fast, accurate and reliable locating results. Lower installation costs.

Third Party Test Locations TRACE-SAFE is the only tracer wire to be independently tested to the following: Corrosion - ASTM B117-03 Salt Spray Accelerated Test Environment National Exposure Testing, Sylvania, OH Detection - McGlaughlin Verifier G2 Digital Locater Staking University, Manteno , IL (www.underspace.com) Mike Parilac: President mike@underspace.com (815-465-7814) Lightning - TIA/EIA 455-81-92 , Lightning Damage Susceptibility for FO Cables with Metalic Components Lightning Technologies, Inc., Pittsfield, MA Connectors UL Grounding and Bonding, UL467-2007 Standard for wire connectors, UL486A, UL486B – 2003 Operating salt spray, ASTM B117-09 Electric Motion Company, Winstead, CT Tensile, Abrasion & Corrosion Tracer Wire for HDD Applications Report Gas Technology Institute, Des Plaines, Il Link to summary, http://www.otd-co.org/Documents/OTD_Tracer_Wire_for_HDD_SummaryReport-02-06-2013.pdf

References GTI Report Connector testing Duke Energy Dennis Jarnecke , (847)768-0943 Dennis.jarnecke@gastechnology.org Connector testing Electric Motion John Carrozzo, (860)379-8515, cell (860)480-3708 johncarrozzo@electricmotioncompany.com Duke Energy Matt Weber (513)287-2988