Testing.

Slides:



Advertisements
Similar presentations
Physical Layer: Signals, Capacity, and Coding
Advertisements

1 Lecture 2 Transmission Line Characteristics 1. Introduction 2. Properties of Coaxial Cable 3. Telegraph Equations 4. Characteristic Impedance of Coaxial.
Cable Testing.
SUNY Ulster Cisco Semester 1 Unit 4 – Cable Testing K. Wick CCAI.
Copper Cable Transmission Characteristics
Old Telephone cabling 4 wire Used in commercial and residence NEW
1000BASE-T Technology Overview
111 © 2002, Cisco Systems, Inc. All rights reserved. Finish Phase Overview Testing Troubleshooting Certification Documentation.
DCN286 Introduction to Data Communication Technology Session 5.
Category 6 Solutions Category 6 Solutions. Intent Category 6 Cabling Where it came from What it is Why you need it How you use it.
Chapter 13 Transmission Lines
Chapter Fourteen: Transmission Lines
Chapter-3-1CS331- Fakhry Khellah Term 081 Chapter 3 Data and Signals.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Copyright Kenneth M. Chipps Ph.D. Testing Copper Media Last Update
1 Telecom Cabling Testing and cable certification.
Oct-03 ©Cisco Systems CCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus, ON, Canada – Clark slide 1 Cisco Systems CCNA Version.
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Data Transmission Slide 1 Continuous & Discrete Signals.
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
Network+ Guide to Networks, Fourth Edition
Institute of Technology Sligo - Dept of Computing Many Roads To Home Paul Flynn.
1 Version 3.0 Module 4 Cable Testing. 2 Version 3.0 Waves Networking professionals are interested in voltage waves on copper media, light waves in optical.
Measuring Frequency The amplitude of an electrical signal represents height and is measured in volts. The period is the amount of time to complete one.
Data Communication and Networking Physical Layer and Media.
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
4 Semester 1 CHAPTER 4 REVIEW JEOPARDY Presented by: Terren L. Bichard.
CCNA 1 Module 4: Cable Testing.
1 Semester 1 Module 4 Cable Testing Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
Electronics and Signals Chapter 4. Parts of an Atom nucleus - the center part of the atom, formed by neutrons and protons nucleus - the center part of.
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Lecture 2 Most basic facts from Electricity needed for understanding telecommunications Local transmission lines in the telephone system Decibels Signals.
Mod 4 – Cable Testing CCNA 1.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
1 CCNA SEMESTER 1 V 3.0 CHAPTER 4 – Cable testing.
NESCOT CATC1 Cable Testing CCNA 1 v3 – Module 4. NESCOT CATC2 Waves 1. The _________ of the waves is the amount of time between each wave, measured in.
1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing.
1 ENE 429 Antenna and Transmission lines Theory Lecture 4 Transmission lines.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
CE 4228 Data Communications and Networking
Networking Fundamentals Copper Core Cable as Network Media.
12 Transmission Lines.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
Copper Testing ELCM 254 Updated Dec
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
CCNA 1 Module 4 Cable Testing. 2 Waves Frequency: Frequency: –the number of waves per second Period: Period: –the amount of time that it takes to complete.
1 ELE5 COMMUNICATIONS SYSTEMS REVISION NOTES. 2 Generalised System.
基智科技 結構化佈線系統測試 基智科技 銅線部分 基智科技 Test Standard Requirements.
Sep-03 ©Cisco SystemsCCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus – Clark slide 1.
1 Discovery 2, Ch 4 Notes. 222 Cabling Standards Standards ensure that networks perform to expectations US—IEEE & ANSI/TIA/EIA Canada—CSA (Canadian Standards.
1.  Transmission lines or T-lines are used to guide propagation of EM waves at high frequencies.  Examples: › Transmitter and antenna › Connections.
Physical Layer PART II. Position of the physical layer.
11/22/2004EE 42 fall 2004 lecture 351 Lecture #35: data transfer Last lecture: –Communications synchronous / asynchronous –Buses This lecture –Transmission.
CCNA1 v3 Module 4 v3 CCNA 1 Module 4 JEOPARDY S Dow.
COPPER AND FIBER REVIEW
Lecture Focus: Data Communications and Networking  Transmission Impairment Lecture 14 CSCS 311.
Cisco Semester 1 Chapter 4 Slides Cable Testing
Module 4 Cable Testing.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Network Media. Copper, Optical, Fibre (Physical Layer Technologies) Introduction to Computer Networking.
TOPIC 1.2 INTRODUCTION TO NETWORKING. OBJECTIVES By the end of the topic, students should be able to: a) List the elements of data communication systems.
By: Thomas Olivotti.  PSNEXT stands for Power Sum Near End Crosstalk and is calculated by transmitting a signal down each wire pair in turn and summing.
Chapter 2 : Data Communications BENG 4522 Data Communications & Computer Networks Transmission Impairment Signals travel through the transmission.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
RF and Microwave Network Theory and Analysis
Lecture 2 Transmission Line Characteristics
James Chen Module 4: Cable Testing James Chen 2018/11/10 Yuda college of business.
Introduction Analog and Digital Signal
Data Communication and Networking
Presentation transcript:

Testing

Maximum Length - 90 Meters Permanent Link Definition Horizontal cabling extending from the wall plate to the cross connect WORK AREA Wall Outlet Maximum Length - 90 Meters Horizontal Cross-connect TELECOMMUNICATIONS CLOSET

Channel Definition The end-to-end transmission path connecting any two points at which application specific equipment is connected. Equipment and work area cables are included in the channel

Channel WORK AREA TELECOMMUNICATIONS CLOSET Wall Outlet Horizontal Equipment Cable Maximum Length 100 Meters Horizontal Concentration Point Cross-connect Patch Cable TELECOMMUNICATIONS CLOSET

Permanent Link Test Configuration WORK AREA TELECOMMUNICATIONS CLOSET Wall Outlet Test Set Test Set Connection Cable (2 meters) Horizontal Maximum Length 94 meters Cross-connect Test Set TELECOMMUNICATIONS CLOSET

Channel Test Configuration WORK AREA TELECOMMUNICATIONS CLOSET Equipment Cable Test Set Maximum Length 100 Meters Wall Outlet Cross-connect Horizontal Test Set TELECOMMUNICATIONS CLOSET Patch Cable Concentration Point

Before we look at each of the basic tests we need to review the Twisted Pair Before we look at each of the basic tests we need to review the Physical Electrical characteristics of a wire pair

Anatomy of a Wire Pair What we think of when we envision a wire pair.

Anatomy of a Wire Pair However, to a signal it looks like: Resistors Capacitors Inductors The cable is not made up of discrete components but has the characteristics of these components Resistance Capacitance Inductance

Damaging the cable The characteristics are changed when a cable is: Stretched (pulling / laying) Kinked (handling / storage / tight corners) Distorted (cable ties / stood upon / Heavy cable bundles)

Physical Layer Tests Test Parameter TIA-568-B ISO 11801:2002 Wiremap Pass/Fail Propagation Delay Delay Skew Cable Length Information only Insertion Loss (IL) Return Loss (RL) Pass/Fail (except Cat3) Near-End Crosstalk (NEXT) Power Sum NEXT (PSNEXT) Equal-Level Far-End Crosstalk (ELFEXT) Power Sum ELFEXT (PSELFEXT) Attenuation-to-Crosstalk Ratio (ACR) Pass/Fail (except Class C) Power sum ACR (PSACR) DC Loop Resistance

Wire Map Verification of the physical connection at each end of the cable Checks for Opens Shorts Crosses Reverses and any other misfiring Splits Difficult to identify with a DC wire map tester Must use an advanced tester Will fail on crosstalk

Length Physical Calculated based on the length markings on the cable Maximum physical length of a permanent link is 90 meters Maximum physical length of a channel is 100 meters

Length Electrical Based on the propagation delay of a signal over the cable pair Accomplished using a TDR (Time Domain Reflectometer) Calculation base on the Nominal Velocity of Propagation (NVP) of the signal over the pair being tested

DATA DATA DATA DATA DATA DATA DATA DATA DATA Attenuation An analogy is friction Some of the signal is lost over distance Energy is dissipated in the form of heat Message may become to weak to be understood DATA DATA DATA DATA DATA DATA DATA DATA DATA

Before we go any further we must talk a little about decibels (dB’s)

Signal Path Decibels dB’s The deciBel is a convenient means of expressing the ratio of two values it is commonly used for example to express the Gain or Attenuation of a signal path: Signal Path Electrical/ Optical Signal Input Electrical/ Optical Signal Output Gain or Attenuation = Output Signal ÷ Input Signal Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 17

Decibels dB’s deciBel expressions for the power and voltage level of a signal are slightly different: Voltage Gain/Attenuation = Power Gain/Attenuation = Note: For Optical Fibre only the Power expression is relevant Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 18

Example 1 A NEXT reading is -40 dB for Pair 1 to Pair2. What percentage of the Pair 1 input voltage appears at the input of Pair 2 ? ANSWER This result says that 1% of whatever is injected into Pair 1 will appear at the input of Pair 2 Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 19

Example 2 A FEXT reading is -50 dB from Pair 3 to Pair2. What percentage of the Pair 3 input voltage appears at the output of Pair 2 ? ANSWER This result says that 0.3% of whatever is injected into Pair 3 will appear at the output of Pair 2 Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 20

Example 3 Pair 4 has an Attenuation reading of 20 dB. What percentage of the Pair 4 input voltage appears at the output of Pair 4 ? ANSWER This result says that 10% of whatever is injected into Pair 4 will appear at the output of Pair 4 Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 21

Back To Attenuation The loss of signal strength over the cable pair, measured in dB Increases as the carrier frequency increases Pass/fail based on the worst case attenuation of all pairs

Attenuation

Crosstalk Defined as the induction of a portion of the signal from one pair into the adjacent pairs Measured in dB

Cross Talk Types NEXT ELFEXT PSNEXT PSELFEXT NEAR END CROSS TALK EQUAL LEVEL FAR END CROSS TALK PSNEXT POWER SUM NEAR END CROSS TALK PSELFEXT POWER SUM EQUAL LEVEL FAR END CROSS TALK

NEXT and ELFEXT A final point is that ELFEXT depends greatly on the length of cable being examined, whereas the NEXT is much less dependent

Crosstalk Components Inductive and Capacitive Relationships:

Cross Talk DATA DATA DDATA DATA DATA DATTA DATA DATA SPILL OVER ELECTRONS ARE LOST TO THE ADJACENT CABLE PAIRS THE MESSAGE IS CORRUPTED DATA DATA DDATA DATA DATA DATTA DATA DATA DATA DATA ATA DATA DATA DATA DAA DATA DATA

NEXT NEXT MEASURES THE CROSSTALK EFFECT ONE PAIR HAS UPON THE OTHER WITH RESPECT TO THE NEAR END OF THE CABLE

Near-End Crosstalk (NEXT)

Power Sum Use of the TIA Algorithm for Calculating Power Sum Calculation is derived from the conventional NEXT measurement. Only one pair is energized at a time; formula “sums” the crosstalk effect of three energized pairs on the remaining fourth pair.

PSNEXT POWER SUM NEXT IS THE COMPUTED EFFECT OF THREE PAIRS UPON THE FOURTH WITH RESPECT TO THE NEAR END OF THE CABLE

ELFEXT ELFEXT MEASURES THE CROSSTALK EFFECT ONE PAIR HAS UPON THE OTHER WITH RESPECT TO THE FAR END OF THE CABLE

PSELFEXT POWER SUM ELFEXT IS THE COMPUTED EFFECT OF THREE PAIRS UPON THE FOURTH WITH RESPECT TO THE FAR END OF THE CABLE

NEXT and ELFEXT NEXT and ELFEXT (and crosstalk in general) depend very much on the frequency at which they are measured they increase as the frequency increases on average they may be described as follows:

NEXT and ELFEXT In practise this means as the Cat6 specification includes frequencies up to 250 MHz, that both the NEXT and ELFEXT measurements will increase dramatically For example the NEXT at 250 MHz should be about 4 times higher than the NEXT at 100MHz for any given combination of pairs Even worse the ELFEXT at 250 MHz should be over 6 times higher than the value at 100 MHz for any given combination of pairs For these reasons (and more) cable that passes Cat 5/5e quite easily may still fail the Cat 6 standard

NEXT dB Calculations CAT 5 to CAT 7 NEXT values at 100 MHz Copyright of the Applied Optoelectronics Centre DIT 19/08/99 Photocopying strictly prohibited 37

Attenuation to Crosstalk Ratio Definition: A ratio comparing the received signal with the near-end crosstalk on a cable It is not a direct test It is a comparison of the attenuation test and NEXT test Used to give an indication of how problem-free the cable line will be Attenuation-to-Crosstalk ratio (ACR) is the difference between the signal attenuation produced and NEXT and is measured in decibels (dB). The ACR indicates how much stronger the attenuated signal is than the crosstalk at the destination (receiving) end of a communications circuit. The ACR figure must be at least several decibels for proper performance. If the ACR is not large enough, errors will be frequent. In many cases, even a small improvement in ACR can cause a dramatic reduction in the bit error rate. Sometimes it may be necessary to switch from un-shielded twisted pair (UTP) cable to shielded twisted pair (STP) in order to increase the ACR.

Attenuation to Crosstalk Ratio (ACR)

Propagation Delay Propagation Delay The time needed for the signal to travel from the transmitter to the receiver over a 100 Ohm 4-pair cable.

Delay THE TRANSMISSION TIME T1 T2

Delay Skew THE DIFFERENCE IN TIME BETWEEN THE FASTEST AND SLOWEST PAIR Delay Skew = Difference between T2 and T3

Delay / Delay skew X DELAY THE TRANSMISSION TIME DELAY SKEW (X) THE DIFFERENCE IN TIME BETWEEN THE FASTEST AND SLOWEST PAIR X

Propagation Delay

DC Loop Resistance DC Loop Resistance measures the total resistance through one wire pair looped at one end of the connection. This will increase with the length of the cable. DC resistance usually has less effect on a signal than insertion loss, but plays a major role if you require power over Ethernet. Also measured in ohms is the characteristic impedance of the cable, which is independent of the cable length

Return Loss It measures the difference between test signal’s amplitude and the amplitude of signal reflections returned by the cable. Information Provided: Indicates how well the cable’s characteristic impedance matches its rated impedance Return Loss is the measurement (in dB) of the amount of signal that is reflected back toward the transmitter. The reflection of the signal is caused by the variations of impedance in the connectors and cable and is usually attributed to a poorly terminated wire. The greater the variation in impedance, the greater the return loss reading. If 3 pairs of wire pass by a substantial amount, but the 4 pair barely passes, it usually is an indication of a bad crimp or bad connection at the RJ45 plug.

Return Loss