High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power.

Slides:



Advertisements
Similar presentations
Low Rise Multi-Family UES Measure (NWESH) Measure Proposal Presentation to the Regional Technical Forum Sept. 19 th, 2012 Spec Development and Analysis.
Advertisements

Advanced Heat Pump Water Heater Research Conducted by WSU Energy Program Funded by Bonneville Power Administration BPA Technology Innovation Project #292.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Northwest ENERGY STAR Specification for Oregon 2012 Active UES Proposal Presentation to the Regional Technical Forum November 1, 2011 Ben Larson, Ecotope.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Residential Heat Pump Water Heaters Heating System Interaction Factor RTF HPWH Subcommittee November 6, 2014.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
1 Air Source Heat Pumps Potential Changes in the RTF’s Specifications & Savings Estimates and Their Impact on C&R Discount Program Credits.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
HPWH UES Measure Initial Review 16 April Agenda Provisional Measure Review Method Overview Prelim Findings Measure Development Approach Simulation.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Presentation, Discussion, and Decision on Deemed Measures for EnergyStar Homes: Zonal Electric Heat Path (BOP2) for ID and MT Ductless Heat Pump Technical.
Northwest Power and Conservation Council Model Conservation Standards Economic Analysis for for New Single Family and Manufactured Home Construction June.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Ben Larson 28 September th Avenue NE, Seattle, WA (206) Fax: (206)
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
High Performance Manufactured Homes Active UES Proposal Presentation to the Regional Technical Forum April 17, 2012 Project Sponsor: Bonneville Power Administration.
Ben Larson 2 November th Avenue NE, Seattle, WA (206)
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Combo products: Space + Water Market Drivers and Field Testing Status.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Washington Residential Energy Code 2012: Overview 17 December 2013 Ben Larson, Ecotope 1.
Ben Larson 19 July th Avenue NE, Seattle, WA (206) Fax: (206)
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Bonneville Power Administration Heat Pump Water Heater Laboratory Testing Results & Field Work.
Predicted Savings for NW Energy Star for Homes and WA BuiltGreen Homes Specification Update Single Family New Construction Regional Technical Forum August.
SEEM Calibration for Manufactured Housing Regional Technical Forum December 13, 2011 Analysis Performed ByAdam Hadley Cursory Reviews ByTom Eckman, Ben.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
1 Mission Valley Power Energy Efficient Home Program and GSHP Deemed Savings Analysis September 30, 2008.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Research Strategy: New-Construction Manufactured Home Measures Research and Evaluation Subcommittee Josh Rushton November 19, 2015.
Direct Use of Natural Gas Status of Analysis Staff Analysis Today’s Agenda: Review of Major Analytical Input Assumptions Present Preliminary Results (Not.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
High Performance Manufactured Homes UES Measures Sunset Date Extension Request Regional Technical Forum December 16 th, 2014.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Manufactured Homes Check-in Christopher Dymond March 14, 2014.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Heat Pump Water Heaters: Interior, Ducted Installations Presentation to the Regional Technical Forum December 13, 2011 Ben Larson, Ecotope
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Presentation transcript:

High Performance Manufactured Homes Provisional UES Proposal Presentation to the Regional Technical Forum May 15, 2012 Project Sponsor: Bonneville Power Administration Presentation by: Ben Larson, Ecotope and Tom Hewes, Northwest Energy Works

Overview / Review Measure first presented at last RTF meeting (4/17/2012) Discussed baseline, energy use / savings, and costs Lacked complete plan to move measure from provisional to active status – This presentation reviews last month’s and concludes with a plan 2

Measure Summary Measure name: High Performance Manufactured Homes (HPMH) Measure sponsor: Bonneville Power Administration Measure description: – Construction of new, manufactured homes in accordance with the High Performance Manufactured Home Specification Measure type: UES Requesting Status: Approved Change in measure status: Yes (proposed  provisional) Change in measure savings: No Change in measure cost effectiveness: No Other or follow-on work for RTF: No 3

Review: Uo Baseline Specifications “HUD+” is the current NW baseline based on current market research by WSU and NEW – The “HUD+” baseline is a better performer than the Federal standard due to decades of market transformation in the PNW All costs and savings are made relative to the “HUD+” baseline 4 Northwest Specific Uo Values TypeCommentsUo HUD Federal Maximum0.079 “HUD+” Northwest Baseline0.065 NEEM Northwest Energy Efficient Manufactured Home0.054 HPMH High Performance Manufactured Home (Super NEEM)0.040

Manufactured Homes Specifications Review ComponentUnits Baseline "HUD+" NEEM HPMH "Super NEEM" Envelope CeilingR-ValueR22R38R45 WallR-ValueR11 -- R21R21 R21 + R5 Foam Sheathing Window U-ValueU-Value Glazing % of CFA12% DoorU-Value0.2 FloorR-ValueR19R33R38 InfiltrationACH VentilationExhaust FanMarket BaseEnergyStar UoBtu/hr-ft 2 -°F HVAC Heating System Electric FAF DHP HSPF 10 & Wall Heaters Cooling System none DHP SEER 20 Supply Duct Leakage% system flow12.5%5%No Ducts Return Duct Leakage% system flowNone - Interior No Ducts DHW Water HeaterEF0.9 EF0.93 EFHPWH Shower Headgpm Lighting LPDW/ft Appliances Dishwasher Market Base EnergyStar Refrigerator Market Base EnergyStar 5

UES Analysis Summary Refer to Measure Workbook

Analysis Approach (1) Lighting calculated with LPD method Appliance savings from existing RTF measures Calibrated SEEM runs for estimating – heating, cooling, ventilation, and DHW DHW energy use – Parallel analysis to HPWH presented in 2011

Analysis Approach (2) Heating, cooling, ventilation, and DHW energy use calculated with SEEM – DHP Modeling methodology from NEEA Ductless Heat Pump Impact & Process Evaluation: Field Metering Report Field findings: DHP heats differing house fraction based on climate – HZ1: 74%, HZ2: 63%, HZ3: 45% Calibrated SEEM to pre/post DHP installation periods at 91 houses – Unique simulations created for each house based on detailed audits – Note: energy uses here not reflective of DHP program savings – they are only applicable here as a calibration exercise – HPWH Modeling based on SEEM simulated annual crawl space temperature profile and HPWH COP map HPWH installed in sound-attenuated, buffered closet which draws air from crawl space and exhausts outdoors 8 Method Heating Energy Use (kWh/yr) N MeanSD Pre-Installation Billing Data Pre-Installation SEEM 66.8°F Setpoint Post-Installation Metered Data Post-Installation SEEM 69.5°F Setpoint

Modeled Crawl Space Air Temperature Crawl space is source of air for HPWH closet SEEM model of 1568 ft 2 HPMH – 4.5 ACH crawl (350 cfm continuous) – likely worst case airflow and temperature – the air in the closet will be warmer due to tank heat loss – R38 floor, no ducts 9

Measure Cost by Category CategoryNotes2011 $s2006 $s Measure Life (yrs) Annual O&M (2006 $s) EnvelopeMajority from Walls and Windows $ 4,277 $ 3,81645 $ - Air Sealing & Ventilation Whole House Exhaust Fan $ 50 $ 4520 $ - HVAC System DHP & Resistance Wall Htrs. (less cost of furnace and duct system) $ 4,701 $ 4,19420 $ - Domestic Hot Water Heat Pump Water Heater $ 1,110 $ $ 26 LightingCompact and Linear Flourescents $ 117 $ 1058 $ (13) AppliancesDishwasher & Refrigerator $ 62 $ 5516 $ - Total $ 10,318 $ 9, Sunset Criteria: – Measure shall sunset at the end of 2014, at which time the lighting savings UES component of the measure shall be reevaluated against the changing federal lighting standards.

Results

12

Energy Use, Savings, and B/C Ratio 13 ClimatesTotal Annual Energy Use (kWh/yr)Savings (kWh/yr) (yrs) HeatingCooling Baseline "HUD+" NEEM HPMH "Super NEEM" HPMH to Baseline B/C Ratio Measure Life HZ1CZ115,83612,9577,6688, HZ1CZ215,83612,9577,7718, HZ1CZ315,83612,9577,9357, HZ2CZ119,59715,5679,23910, HZ2CZ219,59715,5679,33610, HZ2CZ319,59715,5679,49510, HZ3CZ122,55817,57011,14711, HZ3CZ222,55817,57011,23511, HZ3CZ322,55817,57011,38011,

14

Energy Use by Load Significant reductions in space heating, water heating, and lighting over both “HUD+” baseline and NEEM. – Big savings from wall sheathing, triple-glazed windows, DHPs, HPWH, and lighting improvements 15

Moving from Provisional to Active Status Open analytical questions include DHP and HPWH savings – Shell, lighting, and appliance all use previously approved analyses – The RTF and other regional organizations are already pursuing questions related to DHP (due soon) & HPWH (due a bit later) savings Efforts should result in enough information to model DHPs and HPWHs in manufactured houses – Special question regarding HPWH inlet air temperature – air drawn from crawlspace into HPWH closet and then exhausted outside Proposed plan to measure temperature at 10 sites: – crawl space, outside, & HPWH closet temperature – select sites across heating zones – measurements will inform inlet temperature for modeling After DHP & HPWH analyses have been resolved; HPWH inlet air T measured; and Federal Lighting standards updated, the measure will be revised and moved to active status. 16

17

Motion for Approval “I _________ move that the RTF approve the UES for High Performance Manufactured Homes with provisional status which will sunset at the end of 2014.” 18

Contacts Northwest Energy Works Tom Hewes x101 Brady Peaks x Bonneville Power Administration Mark Johnson Ecotope Ben Larson x207

Extras Follow 20

21

22 SEEM Modeled: ACH in Crawl - HPMH Spec Floor (no ducts, R38) TMY3 Data: