Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.

Slides:



Advertisements
Similar presentations
Chapter3 Pulse-Echo Ultrasound Instrumentation
Advertisements

* NEAR ZONE is the nearest area to the transducer & it always has the same diameter of the transducer, BUT if the transducer: Linear the near zone length.
Foundations of Medical Ultrasonic Imaging
Piezoelectric Effect  Sound waves striking a PZ material produce an electrical signal  Can be used to detect sound (and echoes)! Pierre Curie 1880.
Forces and Motion Essential Vocabulary
Ultrasound Transducers
Waves By: S Unit 5 Mechanical waves are disturbances in matter which need a medium to travel through. These waves also carry energy from place to place.
Resident Physics Lectures
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Hospital Physics Group
Pegasus Lectures, Inc. Volume II Companion Presentation Frank Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Chapter 34 The Wave Nature of Light; Interference
Transducers.
Basic Physics of Ultrasound
Sonar Chapter 9. History Sound Navigation And Ranging (SONAR) developed during WW II –Sound pulses emitted reflected off metal objects with characteristic.
Ultrasound Medical Imaging Imaging Science Fundamentals.
1 Sinusoidal Waves The waves produced in SHM are sinusoidal, i.e., they can be described by a sine or cosine function with appropriate amplitude, frequency,
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Ultrasound.
NorCal Tech 2005 Technical Conference
Ultrasonic Testing This technique is used for the detection of internal surface (particularly distant surface) defects in sound conducting.
GENERATING AND DETECTING OF ULTRASOUND
Ultrasound – Physics & Advances
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
Chapter 20 Preview Section 1 The Nature of Waves
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Chapter 9 Electromagnetic Waves. 9.2 ELECTROMAGNETIC WAVES.
George David Associate Professor Ultrasound Physics 04: Scanner ‘97.
LIGHT.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume II Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th.
Pegasus Lectures, Inc. Volume II Companion Presentation Frank Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 27 Physics, 4 th Edition James S. Walker.
High School Physics Day April 3 rd, 2013 Ultrasound Physics & Instrumentation.
Mechanical Waves and Sound
Volume II Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Display of Motion & Doppler Ultrasound
Review of Ultrasonic Imaging
Introduction to the Physics Echocardiography Introduction to the Physics Echocardiography Jose L. Rivera, M.D. January 9, 2010.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
© 2010 Pearson Education, Inc. Lecture Outline Chapter 24 College Physics, 7 th Edition Wilson / Buffa / Lou.
Ultrasound Physics Reflections & Attenuation ‘97.
Ultrasonic İmaging.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Pegasus Lectures, Inc. COPYRIGHT 2006 Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4 th Edition.
Piezoelectric Effect  Sound waves striking a PZ material produce an electrical signal  Can be used to detect sound (and echoes)!
Wave Properties. S8P4. Students will explore the wave nature of sound and electromagnetic radiation. d. Describe how the behavior of waves is affected.
Chapter 22 Section 1 The Nature of Waves Question of the Day What do you think of when you hear the word WAVE? Write a brief description on your paper.
Chapter 22 The Energy of Waves Preview Section 1 The Nature of WavesThe Nature of Waves Section 2 Properties of WavesProperties of Waves Section 3 Wave.
NUR INANI BINTI MOHD RUZLAN A Tissue harmonic imaging is a technique in ultrasonography that provides images of better quality as compared to conventional.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Ultrasound Physics Image Formation ‘97. Real-time Scanning Each pulse generates one line Except for multiple focal zones frame one frame consists of many.
Ultrasound Physics Image Formation ‘97.
Sound in medicine Lect.10.
Reflections & Attenuation
Single-element transducers properties
Ultrasound Physics Image Formation ‘97.
Ultrasound.
Light Interactions The law of reflection states that the angle of incidence is equal to the angle of reflection. Things that are luminous can be seen because.
Review of Ultrasonic Imaging
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
PARAMETRIC SUB-BOTTOM PROFILER: A NEW APPROACH FOR AN OLD PROBLEM
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc.
Chapter 12 Image Artifacts
RED STATION - Waves 1. How is light transmitted through matter that is translucent? Transparent? Opaque? Light goes through transparent materials, the.
Presentation transcript:

Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Ultrasound Physics & Instrumentation 4th Edition Volume I Companion Presentation Frank R. Miele Pegasus Lectures, Inc. Pegasus Lectures, Inc. COPYRIGHT 2006

License Agreement Pegasus Lectures, Inc. All Copyright Laws Apply. This presentation is the sole property of Pegasus Lectures, Inc. No part of this presentation may be copied or used for any purpose other than as part of the partnership program as described in the license agreement. Materials within this presentation may not be used in any part or form outside of the partnership program. Failure to follow the license agreement is a violation of Federal Copyright Law. All Copyright Laws Apply. Pegasus Lectures, Inc. COPYRIGHT 2006

Volume I Outline Pegasus Lectures, Inc. Chapter 1: Mathematics Chapter 2: Waves Chapter 3: Attenuation Chapter 4: Pulsed Wave Chapter 5: Transducers Level 1 Level 2 Chapter 6: System Operation Pegasus Lectures, Inc. COPYRIGHT 2006

Chapter 5: Transducers - Level 1 Pegasus Lectures, Inc. COPYRIGHT 2006

Chapter 5: Transducers Pegasus Lectures, Inc. A transducer is any device which converts one form of energy to another form of energy. nerves lights speakers heaters etc. Pegasus Lectures, Inc. COPYRIGHT 2006

Piezoelectric Effect Pegasus Lectures, Inc. Ultrasound transducers use the piezoelectric effect to convert electrical energy into mechanical energy and mechanical energy back into electrical energy. PZT Electrical to acoustic transformation PZT Acoustic to electrical transformation Pegasus Lectures, Inc. COPYRIGHT 2006

Piezoelectric Effect Pegasus Lectures, Inc. Fig. 2a Expansion Fig. 2b Contraction Fig. 2c At Rest (Pg 235) Pegasus Lectures, Inc. COPYRIGHT 2006

Block Analogy of Crystal Oscillation This analogy is useful to illustrate the concept of the piezoelectric effect. A B C D E A: At Rest B: Stretched C: Recoiled D: Oscillate E: At Rest Fig. 3: (Pg 236) Pegasus Lectures, Inc. COPYRIGHT 2006

Crystal Thickness (t) and PW Operating Frequency A thicker crystal “vibrates” at a lower frequency when driven in a pulsed mode. There is therefore an inverse relationship between crystal thickness and operating frequency in a pulsed mode operation. Thickness (t) Fig. 4: (Pg 238) (Lower Frequency) Longer Period (Higher Frequency) Shorter Period Pegasus Lectures, Inc. COPYRIGHT 2006

PW Operating Frequency (Animation) (Pg 238) Pegasus Lectures, Inc. COPYRIGHT 2006

PW Operating Frequency Equation Pegasus Lectures, Inc. COPYRIGHT 2006

CW Operating Frequency In a CW mode of operation, the frequency at which the crystal vibrates is related to the frequency of the electrical drive signal (as visualized in the animation of the next slide). 5 MHz Voltage 5 MHz Acoustic 10 MHz Voltage 10 MHz Acoustic Fig. 5: (Pg 239) Pegasus Lectures, Inc. COPYRIGHT 2006

CW Frequency (Animation) (Pg 239) Pegasus Lectures, Inc. COPYRIGHT 2006

CW Operating Frequency Equation 5 MHz Voltage 5 MHz Acoustic Pegasus Lectures, Inc. COPYRIGHT 2006

Pulse Response Pegasus Lectures, Inc. Like a bell when rung, a single pulse produces multiple cycles of ringing (the “impulse response”). The following two figures represent the impulse response for a 2 MHz and a 4 MHz transducer design. 2 MHz 4 MHz Fig. 6: (Pg 240) Pegasus Lectures, Inc. COPYRIGHT 2006

Single Crystal Dimensions The diameter of a crystal affects the beamwidth and hence, the focus. The thickness of the crystal affects the operating frequency. These two parameters should not be confused. Diameter (D) PZT Crystal thickness (t) Fig. 7: (Pg 241) Pegasus Lectures, Inc. COPYRIGHT 2006

CW Beamshape Pegasus Lectures, Inc. Since CW is continuously transmitting, the wave exists at all locations simultaneously producing a beam similar to that of a flashlight. (As visualized in the animation of the next slide) Lateral Elevation Depth PZT Crystal Fig. 8: (Pg 241) Pegasus Lectures, Inc. COPYRIGHT 2006

CW Beamshape (Animation) (Pg 241) Pegasus Lectures, Inc. COPYRIGHT 2006

PW Beamshape Pegasus Lectures, Inc. Fig. 9: (Pg 242) Unlike CW mode, in PW, the transmit is turned on and off. The beamshape is therefore a “description” of the shape of the path the sound wave travels over time (as visualized in the animation of the next slide). Lateral Elevation Depth PZT CRYSTAL T1 Lateral Elevation Depth PZT CRYSTAL T1 Lateral Elevation Depth PZT CRYSTAL T1 Lateral Elevation Depth PZT CRYSTAL T1 Lateral Elevation Depth PZT CRYSTAL T1 Depth PZT CRYSTAL Lateral Pegasus Lectures, Inc. COPYRIGHT 2006

PW Beamshape (Animation) (Pg 242) Pegasus Lectures, Inc. COPYRIGHT 2006

Basic Beam Characteristics Although greatly simplified, the basic beamshape is helpful in roughly describing the beam parameters. Notice that the beam is approximately half as wide as the crystal diameter at the focus and the same width as the crystal diameter at the twice the focal depth. Fresnel Zone Fraunhoefer Zone Natural Focus PZT Crystal D1 D/2 D NZL = D2 • f0 6 2 • Near Zone Length Fig. 10: (Pg 243) Pegasus Lectures, Inc. COPYRIGHT 2006

Crystal Diameter and Focus A larger crystal diameter results in a deeper focus for the same operating frequency. Fig. 11: (Pg 244) PZT Crystal Deeper Focus Shallower Focus D1 D2 Pegasus Lectures, Inc. COPYRIGHT 2006

Aperture Effects on Beam Diameter Notice that increasing the crystal aperture by a factor of 2 increases the focal depth by a factor of 4. D2 D1 NZL1 NZL2 D1/2 D2/2 Pegasus Lectures, Inc. COPYRIGHT 2006

Quarter Wavelength Matching Layer The ideal matching layer thickness is one fourth the wavelength (quarter wavelength). With quarter wavelength thickness, the energy that reflects back from the front surface is 180 degrees out of phase with the reflection from the front surface, resulting in destructive interference. This is beneficial since reflections from the matching layer would otherwise obscure the actual desired image from the patient. Fig. 12: (Pg 246) Pegasus Lectures, Inc. COPYRIGHT 2006

Axial Resolution Pegasus Lectures, Inc. The roundtrip effect helps separate by a factor of 2 the echoes returning in the time. Therefore, the resolution in the depth direction is better (less) than the spatial pulse length by a factor of 2. Fig. 13: (Pg 247) Pegasus Lectures, Inc. COPYRIGHT 2006

Axial Resolution Further Defined *Higher frequencies have shorter wavelengths improving axial resolution. Pegasus Lectures, Inc. COPYRIGHT 2006

Lateral Resolution and Beamwidth The lateral resolution equals the lateral beamwidth dimension. If the beam is wider than the distance between two structures, the echo from both structures will overlap, making it impossible to distinguish between the two structures laterally. Fig. 14: (Pg 248) Pegasus Lectures, Inc. COPYRIGHT 2006

Lateral Resolution Pegasus Lectures, Inc. *Higher frequencies form narrower beams improving lateral resolution. Pegasus Lectures, Inc. COPYRIGHT 2006

Techniques for Changing Focus There are four techniques which can be used to change the focus from the natural focus of a crystal design Lenses Curved elements Electronic focusing Mirrors Pegasus Lectures, Inc. COPYRIGHT 2006

Use of Lenses for Focusing PZT Crystal Fig. 15: (Pg 249) Pegasus Lectures, Inc. COPYRIGHT 2006

Curved Surface for Focusing Concave Surface PZT Crystal Fig. 16: (Pg 250) Pegasus Lectures, Inc. COPYRIGHT 2006

Techniques for Changing Focus Mirrors were rarely used and not used currently so will not be further discussed. Electronic focusing is discussed in level 2. Pegasus Lectures, Inc. COPYRIGHT 2006

Simple Transducer Block Diagram The simple block diagram is useful since it illustrates the principal transducer components. You should be able to describe each components purpose and function. Lens Matching Layer Piezoelectric Crystal Backing Material Wires _ + Fig. 17: (Pg 250) Pegasus Lectures, Inc. COPYRIGHT 2006

Notes: Pegasus Lectures, Inc. COPYRIGHT 2006