Experiments with a test sample Sb 2 S 3 We hoped the improvements would surpass our previous 2-frequency experiments with nonmodulated 2 and 14 N in RDX.

Slides:



Advertisements
Similar presentations
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Advertisements

1 Chelmsford Amateur Radio Society Advanced Licence Course Anthony Martin M1FDE Slide Set 12: v1.4, 2-Dec-2012 (4) Receiver Demodulation Chelmsford Amateur.
Nuclei With Spin Align in Magnetic Fields HoHo anti-parallel parallel Alignment Energy  E = h  H o Efficiency factor- nucleus ConstantsStrength of magnet.
Nuclear Magnetic Resonance
Lecture 2 1 H Nuclear Magnetic Resonance. Gas Chromatograph of Molecular Hydrogen at –100 °C Thermoconductivity Detector 12.
NMR SPECTROSCOPY.
7- Double Resonance 1. Types of double resonance experiments 2. 1 H-{ 1 H} Homonuclear Decoupling C-{ 1 H} Heteronuclear Decoupling.
Magnetic Field (B) A photon generates both an electric and a magnetic field A current passing through a wire also generates both an electric and a magnetic.
Noise near peak field is increased Peak width narrow Peak is symmetric Purpose: Resonate nuclei to prevent polarization. Matching the resonant frequencies.
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
A short presentation in the group by Prem Basnet 09/29/04.
Dynamic Effects in NMR. The timescale in nmr is fairly long; processes occurring at frequencies of the order of chemical shift differences will tend to.
Microwave Spectroscopy I
Introduction to Infrared Spectroscopy
Chapter 6 FM Circuits.
Problem Solving Part 2 Resonance.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Electron Paramagnetic Resonance spectrometer
COMMUNICATION SYSTEM EECB353 Chapter 2 Part IV AMPLITUDE MODULATION Dept of Electrical Engineering Universiti Tenaga Nasional.
SPIN 2004 Oct. 14, 2004 W. Kim, S.S. Stepanyan, S. Woo, M. Rasulbaev, S. Jin (Kyungpook National University) S. Korea Polarization Measurements of the.
Chapter 19 Nuclear Magnetic Resonance Spectroscopy Nuclear magnetic resonance (NMR) spectroscopy is based on the measurement of absorption of electromagnetic.
Electron Spin Resonance Spectroscopy
Atomic Emission Spectroscopy
NMR Background Curve Fitting Caitlyn Meditz, on behalf of the Nuclear and Particle Physics Group. Advisor K. Slifer, E. Long Overview Dynamic Nuclear Polarization.
Physical and Chemical Tests 10-1 Purification: Chromatography Distillation Recrystallization Comparison to known compounds: Melting point Boiling point.
Determination of Spin-Lattice Relaxation Time using 13C NMR
Lecture Density Matrix Formalism A tool used to describe the state of a spin ensemble, as well as its evolution in time. The expectation value X-component.
Nuclear Magnetic Resonance Spectroscopy (NMR) Dr AKM Shafiqul Islam School of Bioprocess Engineering.
NMR spectroscopy in solids: A comparison to NMR spectroscopy in liquids Mojca Rangus Mentor: Prof. Dr. Janez Seliger Comentor: Dr. Gregor Mali.
NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY Basics of …….. NMR phenomenonNMR phenomenon Chemical shiftChemical shift Spin-spin splittingSpin-spin splitting.
Eeng Chapter 4 Bandpass Circuits   Limiters   Mixers, Upconverters and Downconverters   Detectors, Envelope Detector, Product Detector  
Oscillator Oscillation Level Detector Current Source Oscillation Level at fixed frequency ‘ν’ When No ESR Oscillation Level reduced when there is ESR.
1 RF (Radio Frequency) technology BASIC TELECOMMUNICATIONS.
Geometric Representation of Modulation Signals
Our goal is to understand the properties of delocalized vacancies in solid 4 He. Using a triplet of orthogonal diffusion measurements we plan to locate.
Figure 8.3 gives the basic layout of a continuous wave NMR spectrometer. These intruments were the original type of instrument and have largely.
Lecture 7 Two-dimensional NMR F2 F1 (  x,  X ) Diagonal (  A,  A ) (  A,  X ) Cross-peak (  X,  A )
Spin Precession Animation “DEMO”
Constellation Diagram
14 N NQR STUDIES OF STABILIZERS DPA, METHYL- AND ETHYL-CENTRALITE J. Luznik, J. Pirnat T. Apih and Z. Trontelj Institute of Mathematics, Physics and Mechanics.
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Förster Resonance Energy Transfer (FRET)
Optical Zeeman Spectroscopy of Iron Monohydride, FeH Jinhai Chen, Timothy C. Steimle Department of Chemistry and Biochemistry, Arizona State University.
1.1 What’s electromagnetic radiation
Magnetic Resonance Imaging Glenn Pierce, King’s College London, Department of Physics Introduction Edward Purcell and Felix Bloch were both awarded the.
Polarization enhanced NQR detection at low frequencies EUROMAR 2008, Saint Petersburg, Russia, 6-11 July 2008 Janko Luznik Institute of Mathematics, Physics.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Experimental Detection of the Magnetic Resonance signal requires setting up a non-equilibrium state What is the thermal equilibrium available to start.
Nuclear Magnetic Resonance (NMR) for beginners. Overview NMR is a sensitive, non-destructive method for elucidating the structure of organic molecules.
MOLECULAR STRUCTURE ANALYSIS NMR Spectroscopy VCE Chemistry Unit 3: Chemical Pathways Area of Study 2 – Organic Chemistry.
NMR Using a Halbach Array Michael Dillman, on behalf of the Nuclear and Particle Physics Group. Advisor K. Slifer, E. Long Motivation : Nuclear Magnetic.
Crystal Oscillator Circuit and Its Working
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
Modelling LED Lamps with Thermal Phenomena Taken into Account Krzysztof Górecki and Przemysław Ptak Gdynia Maritime University Department of Marine Electronics.
(Instrument part) Thanundon Kongnok M
Topics for today: 1) A few comments on using NMR to investigate internal motions in biomolecules. 2) “MRI”, or Magnetic Resonance Imaging (The last day.
CHAPTER 3 Frequency Modulation
Capacitance, Phase, and Frequency
Introduction & Its instrumentation
Polarization enhanced low frequency NQR detection
10.3 NMR Fundamentals nuclear spin calculations and examples
10.5 Fourier Transform NMR Instrumentation
10.4 Continuous Wave NMR Instrumentation coherent detection
8.5 Modulation of Signals basic idea and goals
Module V Wave Analyzers
Nuclear Magnetic Resonance
14N NQR STUDIES OF STABILIZERS DPA, METHYL- AND ETHYL-CENTRALITE
Exceptional Events During the Operation of the European XFEL
Presentation transcript:

Experiments with a test sample Sb 2 S 3 We hoped the improvements would surpass our previous 2-frequency experiments with nonmodulated 2 and 14 N in RDX (~5 MHz), where often spurious resonances were observed. FIG.4. Sb 2 S 3 molecule in the crystal structure Pbnm (2/m2/m2/m). TAB. I. Two sets (  ~ 0 and  ~ 0.38) of NQR lines [MHz] for 121 Sb (5/2) and 123 Sb (7/2) at 300K 2  ~0: 121 Sb(1) 123 Sb(1);  ~0.38: 121 Sb(2) 123 Sb(2)  3/2  5/2 | | /2  7/2 | 80.86| Stronger lines, applicable as 1 are those at 26.93, and MHz. Magnetic moment and its coupling to RF (saturation) are higher by 121 Sb, what favors the lines and MHz. But the range of our RF source is 80 MHz, which leaves us with three 2-fr. combinations: ( )MHz (more promising), ( )MHz and ( )MHz (71.23 = ). For 2 it should hold: the wider the separation of levels, the stronger is the relative change of populations. However, our RF source’s output power was limited and insufficient for complete saturation. Estimated upper limit of the effect is line intensity change 42% for ( )MHz. The quadrupole relaxation times T 2 of two 121 Sb lines at r.t. have been measured as ~80  s and ~100  s 2. ___________________________ 1. R.V. Pound, Phys.Rev. 79, 685 (1950); A. Abragam, Princ.of Nucl. Magnetism, Oxford Univ.Press, London 1961, p.p I.A. Safin, I.N. Pen’kov, Dokladi ak.nauk SSSR, Fiz.him., T.147, (1962). Proposed CW two-frequency NQR As a detector of RF transition a super- regenerative oscillator-detector (SRO) can be used. It has a characteristic transfer function and a typical record of a single sharp spectral line is shown below. FIG.2. SRO spectrum of a sharp line. FIG.3. Schematic set-up of our “CW” two-frequency NQR (using SRO and synchronous quenching of 1 and 2 ). Possibility of indirect CW detection of two-frequency NQR J. Pirnat a, J. Lužnik a, and Z. Trontelj a, b a) Inst. of Mathematics, Physics and Mechanics, b) Fac. of Mathematics and Physics, Univ. of Ljubljana, Slovenia Introduction Multi-frequency pulse NQR as a measuring technique introduces new possibilities in the field of magnetic resonances. In our contribution development and testing of a simple CW parallel to known pulse versions is presented: two RF fields are applied simultaneously at two suitable frequencies to a multilevel quadrupole nucleus (I  1, electric field gradient asymmetry   0). In some special cases, for instance in the case of detecting a possible presence of some discrete known spectral lines or by evaluating their intensity or shift, the CW techniques based on modern IC components might be useful. The aim of our investigation is to test the feasibility of a technically nondemanding and energy saving CW technique and to improve sample specific NQR detection in this case. FIG.1. Let the observed quantum system consist of more than two energy eigenstates with several transitions allowed (respective example: quadrupole 121 Sb nucleus with I=5/2). When observing the intensity of a chosen line 1, temporary simultaneous RF irradiation (partial saturation) of any other connected transition 2 ( or ( )) can change the former line’s intensity. Pound’s experiments with quadrupole perturbed NMR from can be regarded as the basis of this technique. Summary An alternative CW method of indirect detection of interacting multiple NQR transitions is proposed and tested. Present sensitivity is disappointing, but it might be improved by development of new SRO detectors “on chip” or by applying other type CW detectors. The orthogonal coil system should be improved. Expected instrumentation price and energy consumption of such spectrometer are low. The method should be more efficient at high frequencies (higher population differences). Commercial SROs - chips from ~300 MHz to >1 GHz are available (communication applications). Further work is in progress. Tuning of the SRO to any of the stronger side-bands 1  n.f q ; output offset indicates NQR Measurement procedure: Adjusting RF amplitude and quench timing of the second RF field 2 ; step-wise increasing/decreasing of 2 through the connected transition. Recording the output offset of the SRO to see the change when 2 passes the connected resonance. Phenomenon size estimation - - assuming 3 levels and proportionality of the line intensity and the corresponding population difference (linearized Boltzman f.). Population differences at thermal equilibrium…, during saturating trans. E 3 -E 2 (equalizing the coresp. pop.)  ======================  E 2 -E 1 pop.difference increase E 3 -E 1 pop.difference decrease The 1 signal change at double resonance is overestimated (at least 2x) because of orthogonal orientation of both RF coils and because of neglecting other influences. Relaxation is important and should be considered as well, but it will be done in future. Efficiency of the saturating RF field (magnetic coupling to NQ probes) should be considered too. Technical difficulties: Perturbation of the SRO by the second RF field 2 ; SRO output fluctuations due to small temperature variations (NQR thermal coefficient) and other instabilities. Accomplished improvements: 1. Empirical adjustment of orthogonality of the saddle coil. 2. Coherent quenching of the second frequency to eliminate its coupling to SRO in the detecting intervals of SRO. 3. Series capacity tuning of the saddle coil to maximize RF at Magnetic modulation and lock-in detection of NQR. 5. Replacement of the quench servo system by fixed grid voltage at SRO. FIG Sb NQR signal near MHz ( 2 ) recorded indirectly as 1 intensity change of MHz NQR. FIG Sb NQR signal near MHz ( 2 ) recorded indirectly as 1 intensity change of MHz NQR. FIG.5. Time dependence of the SRO oscillations (upper) synchronized with the gated RF radiation 2 (lower) in orthogonal direction.