FNAL Emittance Devices Flying Wires (FW) Sync Lite Ion Profile Monitors (IPM) aah,6/20/2000.

Slides:



Advertisements
Similar presentations
5/3/2015J-PARC1 Transverse Matching Using Transverse Profiles and Longitudinal Beam arrival Times.
Advertisements

Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
AGS pp Status Feb. 6, 2015 RSC Meeting Haixin Huang.
ECFA-DESY workshop, NIKEF 1 st April, 2003Nick Walker, DESY Energy Spread Measurement in the TESLA Extraction Line Nick Walker - DESY.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Imaging Science Fundamentals Chester F. Carlson Center for Imaging Science Display Systems Viewing Images.
The 2nd Tevatron Electron Lens and tests of a new electron gun in the framework of Beam-Beam Compensation project Yu. Alexahin, V. Kamerdzhiev, G. Kuznetsov,
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
Searching for Quantum LOVE at the Australian Synchrotron Light Source Eugene Tan On behalf of Rohan Dowd 120/10/2010Eugene Tan – IWLC 2010, Genega ASLS.
Ultra-Low Emittance Storage Ring David L. Rubin December 22, 2011.
The Television Camera The television camera is still the most important piece of production equipment. In fact, you can produce and show an impressive.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
INTRODUCTION  RECYCLER BPM – Original system not adequate to measure beam position precisely. It is being upgraded to meet the required physics precision.
Tevatron BPM System Upgrade Technical Update Bob Webber Run II Luminosity Upgrade Review February 2004.
AAC February 4-6, 2003 Protons on Target Ioanis Kourbanis MI/Beams.
Details of space charge calculations for J-PARC rings.
Dog( leg )s of War Eric Prebys Run II Meeting March 13, 2003.
Energy calibration at LHC J. Wenninger. Motivation In general there is not much interest for accurate knowledge of the momentum in hadron machines. 
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
RHIC Status: Startup Run 12 V. Schoefer RHIC Spin Collaboration Meeting 1/13/12.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
J. Pfingstner Jitter studies February 12, 2014 Optics corrections in the ATF damping ring Jürgen Pfingstner, Yves Renier.
Overview of Electron Cooling Activities at FNAL Thomas Kroc Fermilab – Electron Cooling EIC 2004 March 15-17, 2004 Jefferson Lab.
Overview: Primary Sensitivities Nov S. Childress Page 1 NuMI Overview: NuMI Primary Beamline Sensitivities NuMI requirements are for a very large.
Plan in summer shutdown Magnet -SF1FF -Swap of QEA magnet - Multipole field of Final Doublet IP-BSM improvement.
S. Pordes - to part of CD 09/10/031 Introduction to some Beams Division jargon in some order…see how far we get:
April Tevatron Lifetimes - P. Lebrun1 f On Tevatron Lifetimes, Beams, Luminosity & Spot size Paul Lebrun Fermilab April
Matching monitors for SPS and LHC E. Bravin 31 March 2011.
1 Experience at CERN with luminosity monitoring and calibration, ISR, SPS proton antiproton collider, LEP, and comments for LHC… Werner Herr and Rüdiger.
IPM EM Simulations 9 th DITANET Topical Workshop on Non-Invasive Beam Size Measurement for High Brightness Proton and Heavy Ion Accelerators April.
The SPS as a Damping Ring Test Facility for CLIC March 6 th, 2013 Yannis PAPAPHILIPPOU CERN CLIC Collaboration Working meeting.
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Simultaneous Position Measurements of Protons and Anti-Protons in the Tevatron R. K. Kutschke †, J. Steimel, R.Webber, S. Wolbers, Fermilab*, Batavia,
Recycler Flying Wires Martin Hu Recycler Department.
Beam intensity profile measurements with the RHIC (AGS) C-CNI polarimeters. Polarization profile measurements. Polarimeter target mechanisms upgrades.
, Dan Peterson Apparent inconsistencies and other issues in the xBSM measurements of IBS Scans We have studied the pinhole and CodedAperture.
First Demonstration of Optics Measurement and Correction during Acceleration Chuyu Liu Collider Accelerator Department, BNL.
9/2/2003Tev BPM requirements1 Tevatron BPM and BLM requirements Mike Martens.
9/25/2006All experimenters meetingA. Jansson 1 Tevatron Ionization Profile Monitors Andreas Jansson.
F A Fermilab Roadmap Dave McGinnis May 28, f Fermilab Roadmap - McGinnis Timelines  Divide the road map into three parallel paths  ILC - Energy.
P-Carbon CNI polarimeter upgrades. Vacuum system. Target drives. Targets. Polarimetry Workshop, July 31, 2009 A.Zelenski for polarimetry group.
10/5/2005 jrz1 Not quite “All” you want to know about Flying Wires At Fermilab Jim Zagel 10/5/2005.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Beam time structures 1 At any particular instance of time there will be only one kind of beam in the MI. It will be either protons or anti-protons. The.
Vladimir Sirotenko, Feb FPD: Runs & hisDB Oracle Databases Goal: access information about FPD experimental setup and accelerator conditions which.
F f Quadrupole Pick-Ups at CERN & Fermilab A.Jansson FNAL.
12/16/03Tev BPM requirements1 Tevatron BPM requirements Mike Martens.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
RHIC Status April 8, 2011 RSC Meeting Haixin Huang.
Tevatron Beam Position Monitor Upgrade Stephen Wolbers (for the Tevatron BPM Upgrade Project) PAC05, Knoxville, TN May 16-20, 2005.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting.
10/3/2003Andreas Jansson - Tevatron IPM review1 Tevatron IPM Proposed design.
AGS FY11 Summary RHIC Spin Collaboration Meeting 5/6/11.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
LEReC BPM Status P. Cernigla, R. Hulsart, R. Michnoff, Z. Sorrell June 2, 2016.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
SDA- Shot Data Analysis Jean Slaughter DOE Review July 21, 2003.
IPM Simulations at Fermilab 3-4 March 2016 Randy Thurman-Keup.
Ion Profile Monitors _ 2017 Jim Zagel GSI - IPM17 Workshop
LHC Wire Scanner Calibration
Electron Cloud Measurement Summary for the April 2014 Run
E-beam scanner experience at FNAL
Summary of experience with Tevatron synchrotron light diagnostics
Summary of experience with IPM measurements at BNL-RHIC
A precision measurement of d2 on the neutron
Linac Diagnostics Commissioning Experience
Some of the Points Raised During my JLAB Visit
Measurement of the beam (transverse) emittances
Presentation transcript:

FNAL Emittance Devices Flying Wires (FW) Sync Lite Ion Profile Monitors (IPM) aah,6/20/2000

Flying Wires Flying Wires are located in the Tevatron and Main Injector Accelerators. They represent the principle emittance measurment devices in the FNAL complex. Complex motion/measurement system, but once solved, provides very accurate and believable RMS measurements. Major uncertainties are in the position measurement and the linearity of the pickups (plastic scintillator-pmt assemblies). –Online examination of the motion allows smoothing, and other software interpolation, but up to now, the raw position data are good enough. –The linearity has been studied by comparing the areas of the profiles with measured beam intensities from other methods. They agree at the 5% level. –We are exploring the use of solid state pmt equivalents. 30  m wire diameter contributes at most 7.5  m (in quadrature) to measured beam rms profile, not significant for Tevatron beam sizes of ~0.5mm.

Flying Wire profiles (proton and antproton) at the three Tevatron FW cans. Horizontal E17 is a high dispersion region

Sync Lite Optics: We cannot setup in tunnel with external light source since the source region (edge of Tevatron Dipole) is in a Cryo region. So a lot of problems were related to poor optic configurations, which were only finally fixed (by trial and error) in the last few months of Run 1b (Jan-Feb 1996). Worries about gain saturation/sag in image intensifier (microchannel plate) led to measurements which show at most a ~5% effect when the light level was changed a factor of 2. Image Intensifier develops dead areas after long term exposure to bright beam spots. Tried to ameliorate by turning it on only during measurement and turning it off immediately after. Also implemented software gain correction based upon a gain map obtained by illuminating the image intensifier with a UV light (once a day). This map was used to make a pixel by pixel gain correction. (see the Proton Cal and Pbar Cal Windows on Sync Lite Picture on next slide). Especially note dark areas due to aging on Proton Cal image.

Image from Sync Lite (AntiProton Bunch 1) Note that ellipse fit is not enabled in this particular picture.

FW and Sync Lite Performance Datalog plot (saved every 15 minutes) from Feb Actually FW sampled every 30 minutes, SL every 12 seconds. From Start of Store 5906 to end of Store. (Pbar mirror inserted after Low-Beta Squeeze, which is why it is off-scale at the beginning) Green (Yellow) = Proton(Pbar) RMS beam size from SyncLite Blue (Red)= Proton(Pbar) RMS beam size from Flying Wires.

Comparison FW to SL The emittances were not archived, so in order to compare the RMS beam size, we need the scale factor between FW and SyncLite = (  FW /  SL ) 0.5 The values are Proton (Pbar) = 0.85(0.88) Measured ratio Proton(Pbar) from previous slide = 0.88(0.89). They agree quite well (4% systematic) Statistical error/measurement also can be seen on the plot, roughly at the few % level.

Ion Profile Monitor (IPM) IPM’s are installed in Booster (0.4->8GeV), Recycler (8GeV), Main Injector (8->150GeV), and are planned for Tevatron. The correction factor (due to space charge of beam) for narrow high intensity beams (>e12 and 50% and larger). We believe it makes sense to change over to e - collection and place the entire assembly within a 2~3kG magnetic field. This should almost eliminate the corrections to values on the order of 10~20%. That being said, we have had very significant problems making precision absolute IPM measurements at the 2~3mm rms level. This brings up several electrical/mechanical issues: –Saturation of the microchannel plate gain stage of the IPM (or ePM). We have purchased and used “high” leakage current glass, which helps somewhat. We have not yet been able to calibrate the gain of the IPM (channel to channel variations and absolute gain). Beam bumping has provided some information concerning relative gains. –Suspicions that the IPM channel strips (0.5mm x 100 mm) are not parallel to the beam direction, thus broadening the measured beam rms size. We are planning to add an in situ motor alignment. The technique will be to adjust the relative angle of the strips to the beam, by minimizing the rms beam size.

IPM Continued We run the IPM’s in turn by turn mode. The analog electronics provide some analog integration (~1  s, roughly a Booster Batch). Their general utility up to now has been to monitor the beam at injection, where we look for relative changes in beam position and sigma.

First 512 turns of beam injected into FNAL Recycler. Two lower left plots show Sigma and Position of beam (in mm) vs turn #. Right Plot is false color mountain range plot of same 512 turns (injection is at bottom of plot. Upper left plot is data and fit of turn # 35 (very close to injection).

FFT (in tune units) of first 512 turns of Position (left plot) and Sigma (RMS) from previous IPM Slide. Vertical tune = Peak at in Sigma plot corresponds to (1-2*tune) of posititon plot, indicating a beta wave around the Recycler. Shows capability of IPM in turn by turn mode to measure injection Beta wave when only relative beam sizes matter