Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training 7.6.2012.

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
CENTURION™ (C4-SERIES) Erin Cox, Market Research Analyst, Natural Gas Production Controls - Presenter Sanjay Kumar, Market Research Specialist & Product.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
6000 Series Recorders. The Best Paperless Graphic Recorder in the World.
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
W650 Wind Generator Protection System
SYMAP-BC SYMAP-BC.
Generator Management Relay
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
MIG II DIGITAL FEEDER PROTECTION
Chapter 7 SYSTEM PROTECTION
1 Industrial Systems A dvanced L ine P rotection S ystem.
Interconnect Protection of Dispersed Generators
G650 Generator Protection & Control System
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Looking for a more powerful circuit monitor?
April 2011 ezPAC SA320/330. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.
Electrical Distribution Training
April 2011 November 2010.
A new class in PC Data Acquisition Delphin Technology AG Felix Ottofuelling V5.0.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
Electrical Distribution Training
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Frankfurt (Germany), 6-9 June 2011  PV in Spain: Basically Large plants connected to MV or HV Mainly in rural areas (generation exceeds consumption) 3,000.
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
3-Phase Submersible Motor Control
Protection & Switchgear
SmartMQn Motor Horner APG, LLC September 9, 2008.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
1 Distributed Generation and Power Quality-Continued.
CUE – Make Any Pump an E-Pump
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Distribution Solution. Distribution Solution - Topics Substation Automation Conventional vs New Technology RED 500 protection relays REJ, REU Multipurpose.
Microgrid Load Management and Operation Erich Keller G&W Electric Co. Frank Patton Jr., PE N. J. Shaum & Son, Inc.
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Abilene Mc Camey Big Spring. Far West Abilene Area All the values are based on returned ERCOT survey results Total number of Wind Powered Generation.
MiCOM P125 P126 & P127 27th, Aug 2007 Lakshmikanthan Balaji Application Engineer.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
Interconnect Protection of Dispersed Generators
Unit 45: Circuits and components Dr
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Lesson 16: Asynchronous Generators/Induction Generators
FEEDER PROTECTION UNIT
Grid feeding monitoring relay
PowerValue 11/31 T Sales Presentation
Chapter 7 System Protection
Presentation transcript:

Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training

Agenda What is mains protection? Protection functions Different applications Configuration and settings Communication New trends and R&D

≈ = What is mains protection?

How mains protections work 500 kW power plant; 0,25 EUR per kWh → EUR 3000 per day Property damage EUR = 140% of yearly revenue

1. To protect the utility grid (mains) and its consumers 2. To protect the equipment of the site owner 3. To protect the investment of the site operator Role of mains protection

ComAp mains protections MainsPro Essential functions Approved by utilities InteliPro Advanced functions Flexible configuration

Protective functions

Essential protective functions: 2-level over/undervoltage 2-level over/underfrequency Vector shift Rate Of Change Of Frequency Symmetrical components Last trip record Mechanical sealing MainsPro - ingeniously simple

Wider range of protective functions Additional features Comprehensive history log Full configurability through PC SW Plug-in communications concept CAN connection to controllers InteliPro - simply ingenious

Basic functionsANSI Over/undervoltage, voltage asymmetry27, 59, 47 Over/underfrequency81H, 81L Directional power (both directions) Instantaneous overcurrent, Time overcurrent50, 51 Current asymetry46 Earth fault current50N, 51N Breaker failure protection Automatic fault-reset Analog and binary switches Maximum parallel time Basic protective functions

Optional protective functions Optional functions ANSI Vector shift78 ROCOF81R Directional overcurrent67 Sync-check25 Neutral voltage displacement59N Auto-reclosing79 Time overcurrent with voltage restraint51V

Voltage Adjustable time delays for both levels, U/O voltage 10 minutes floating average overvoltage Voltage unbalance (ANSI 47) Detection of increased difference of voltage amplitude between two phases Voltage asymmetry Detects angle asymmetry of the measured voltage

„Inverse definite minimum time“ overcurrent Moderate, very or extremely inverse ANSI IEC ComAp curve IDMT overcurrent

Adjustable direction and limit Directional power 0 kW - kW (export) + kW (import)

Directional overcurrent

Loss of mains protections Vector shift (ANSI 78) Rate of Change of Frequency – ROCOF (ANSI 81R)

Mains protections applications

Usual applications CHP Micro-turbines Biogas stations Renewables PV power plants Small hydro Grid-tied wind Biomass plants

Different operation Simple application 1 CB operated Complex application 2 CBs operated

Simple applications Comm Trp output used CB1 Feedback Remote switching Blocking of functions by Setpoints Binary inputs

Complex applications CB1 and CB2 operated independently „Priority switching“ function CBs can be used as backup to each other Blocking of functions

Mains protection added value

Configuration and settings

MainsPro Easy wiring Manual settings and operation No PC SW needed 5 relay outputs 4 binary switches Remote or manual fault reset Automatic return to mains

InteliPro Full configurability through LiteEdit PC software

Lite Edit

Communication

Plug-in modules support IB-Lite (Ethernet) IL-NT GPRS IL-NT RS232 (Modbus) IL-NT RS485 (Modbus) IL-NT USB Active SMS messages at pre-set event History log 330 event-driven records InteliPro

New trends and Research & Development

New trends Widespread power generation Grid stability maintenance Increased requirements

Research & Development New features added to MainsPro Average voltage Automatic return to mains 5 last events record (not released yet) New features added to InteliPro Dynamic grid support Pole slip protection (not released yet) QU (reactive power undervoltage) protection (not released yet)

Available materials Datasheets Manuals – comprehensive guides Default set up sheet in every box Protection catalogue Technical support

Buy Additional Features You pay only for what you need Provides possibility of adding further functions Access through ComAp VIP page

Questions?

Thank you!