Potentiometric Methods

Slides:



Advertisements
Similar presentations
CE 541 Complex Formation.
Advertisements

Review of Analytical Methods Part 2: Electrochemistry
Potentiometric Methods
Potentiometric Methods A.) Introduction:
15-1 Potentiometry Potential measurements of electrochemical cells Ion selective methods §Reference electrode §Indicator electrode §Potential measuring.
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
Summary of Potentiometry:
Reactions in Aqueous Media
Introduction to Analytical Chemistry
Electricity from Chemical Reactions
Chemical equilibrium: electrochemistry 자연과학대학 화학과 박영동 교수.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Tracking Reaction Progress via Electrochemical Methods.
Electroanalytical – Introduction Ch 21, 7th e, WMDS)
Measuring concentration using electrodes Indicator electrodes used with reference electrode to measure potential of unknown solution E cell = E indicator.
POTENTIOMETRY 9th lecture
Electrodes and Potentiometry
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
14-6 Cells as chemical probes
Cell Voltages To compare cells compare voltages of cells in their standard state. Standard States For solids and liquids: the state of the pure solid or.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Oxidation-Reduction (Redox) Reactions
Prentice Hall © 2003Chapter 20 Zn added to HCl yields the spontaneous reaction Zn(s) + 2H + (aq)  Zn 2+ (aq) + H 2 (g). The oxidation number of Zn has.
Solubility Equilibrium In saturated solutions dynamic equilibrium exists between undissolved solids and ionic species in solutions Solids continue to dissolve.
POTENTIOMETRY 8th lecture
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
Electrochemistry The first of the BIG FOUR. Introduction of Terms  Electrochemistry- using chemical changes to produce an electric current or using electric.
EDTA Titration EDTA = Ethylenediaminetetraacetic acid
电化学的有关概念: 电池、电极 双电层结构 液接电位、盐桥 传质过程:扩散、迁移、对流 极化:浓差极化、电化学极化 过电位
Solubility Allows us to flavor foods -- salt & sugar. Solubility of tooth enamel in acids. Allows use of toxic barium sulfate for intestinal x-rays.
Electroanalytical methods
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Potentiometry Dr Hisham E Abdellatef 2010.
Unit 2 Electrochemical methods of Analysis
Coulometric Methods A.) Introduction:
Copyright Sautter SOLUBILITY EQUILIBRIUM Solubility refers to the ability of a substance to dissolve. In the study of solubility equilibrium we.
Announcements Course Evaluations Final is Wednesday Afternoon on May 9 th Homework 14-15, 14-26, 15-6, 16-3, 16-6,
Chapter 15 Electrode Measurements “Chem 7” test in hospital lab. Na +, K +, Cl -, CO 2, glucose, urea, & creatinine ion-selective electrodes.
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
Precipitation Titrations Dr. Riham Ali Hazzaa Analytical chemistry Petrochemical Engineering.
CHAPTER 11 ELEMENTS OF ELECTROCHEMISTRY Introduction to Analytical Chemistry.
1 Titration Curve of a Weak Base with a Strong Acid.
Ch 16: Redox Titrations Redox titrations are essential in measuring the chemical composition of a superconductor (YBa 2 Cu 3 O 7 - 2/3 Cu 2+ and 1/3 the.
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
THE ELECTROD AND REDOX POTENTIIALS.
LECTURE 7: Electrochemistry. Types of electrodes and their using. ass. prof. Yeugenia B. Dmukhalska.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
POTENTIOMETRY.
Chapter 21 Potentiometry. Potentiometric methods of analysis are based on measuring the potential of electrochemical cells without drawing appreciable.
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
Ch. 21 Potentiometry 1. General principles
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Inovace bakalářského studijního oboru Aplikovaná chemie Reg. č.: CZ.1.07/2.2.00/
The reversible electrodes
Chapter 7 Electrochemistry § 7.6 Reversible cell.
Potentiometry and Ion-Selective Electrodes 1 Lecture 1.
Chem. 133 – 2/28 Lecture.
Potentiometry and potentiometric measurements
Ion Selective Electrode
Potentiometry Potential measurements of electrochemical cells
Electrode Measurements – Ch 15
Potentiometric Titration
Chapter 23 Potentiometry.
Presentation transcript:

Potentiometric Methods A.) Introduction: 1.) Potentiometric Methods: based on measurements of the potential of electrochemical cells in the absence of appreciable currents (i . 0) 2.) Basic Components: a) reference electrode: gives reference for potential measurement b) indicator electrode: where species of interest is measured c) potential measuring device

B.) Reference Electrodes: 1.) Need one electrode of system to act as a reference against which potential measurements can be made  relative comparison. Desired Characteristics: a) known or fixed potential b) constant response c) insensitive to composition of solution under study d) obeys Nernest Equation e) reversible

B.) Reference Electrodes: 2.) Common Reference Electrodes used in Potentiometry a) Calomel Electrode (Hg in contact with Hg2Cl2 & KCl) i. Saturated Calomel Electrode (SCE) very widely used ½ cell: Hg/Hg2Cl2 (satd), KCl (xM)|| ½ reaction: Hg2Cl2 (s) + 2e- ↔ 2Hg + 2Cl- SCE Note: response is dependent on [Cl-]

b) Silver/Silver Chloride Electrode - most widely used reference electrode system - Ag electrode in KCl solution saturated with AgCl ½ cell: Ag/AgCl (satd), KCl (xM)|| ½ reaction: AgCl (s) + e- ↔ Ag(s) + Cl- Advantage – one advantage over SCE is that Ag/AgCl electrode can be used at temperatures > 60oC Disadvantage – Ag reacts with more ions Vycor plug c) Precautions in the Use of Reference Electrodes - need to keep level of solution in reference electrode above level in analyte solution - need to prevent flow of analyte solution into reference electrode ‚ can result in plugging of electrode at junction  erratic behavior

C.) Indicator Electrodes: 1.) Detects or Responds to Presence of Analyte Three Common Types: a) Metallic Indicator Electrodes b) Membrane Indicator Electrodes c) Molecular Selective Electrode

2.) Metallic Indicator Electrode (Four Main Types) a) Metallic Electrodes of the First Kind i. Involves single reaction ii. Detection of cathode derived from the metal used in the electrode iii. Example: use of copper electrode to detect Cu2+ in solution ½ reaction: Cu2+ + 2e- ↔ Cu (s) Eind gives direct measure of Cu2+: Eind = EoCu – (0.0592/2) log aCu(s)/aCu2+ since aCu(s) = 1: Eind = EoCu – (0.0592/2) log 1/aCu2+ or using pCu = -log aCu2+: Eind = EoCu – (0.0592/2) pCu iv. Problems: - not very selective - many can only be used at neutral pH metals dissolve in acids - some metals readily oxidize - certain hard metals (Fe, Cr, Co, Ni) do not yield reproducible results - pX versus activity differ significantly and irregularly from theory

2.) Metallic Indicator Electrode (Four Main Types) b) Metallic Electrodes of the Second Kind i. Detection of anion derived from the interaction with metal ion (Mn+) from the electrode ii. Anion forms precipitate or stable complex with metal ion (Mn+) iii. Example: Detection of Cl- with Ag electrode ½ reaction: AgCl(s) + e- ↔ Ag(s) + Cl- EO = 0.222 V Eind gives direct measure of Cl-: Eind = Eo – (0.0592/1) log aAg(s) aCl-/aAgCl(s) since aAg(s), aAgCl(s)= 1 and Eo = 0.222 V: Eind = 0.222 – (0.0592/1) log aCl- iv. Another Example: Detection of EDTA ion (Y4-) with Hg Electrode ½ reaction: HgY2- + 2e- ↔ Hg(l) + Y4- Eo = 0.21 V Eind responds to aY4-: Eind = Eo – (0.0592/2) log aHg(l) aY4-/aHgY2- since aHg(l) = 1 and Eo = 0.21 V: Eind = 0.21 – (0.0592/1) log aY4-/aHgY2-

aca2+ . aY4- ay4- = aCaY2- Kf . aca2+ 2.) Metallic Indicator Electrode (Four Main Types) c) Metallic Electrodes of the Third Kind i. Metal electrodes responds to a different cation ii. Linked to cation by an intermediate reaction - Already saw detection of EDTA by Hg electrode (2nd Kind) ii. Can be made to detect other cations that bind to EDTA  affecting aY4- iv. Example: Detect Ca by complex with EDTA equilibrium reaction: CaY2- ↔ Ca2+ + Y4- Where: Kf = \ Eind = 0.21 – (0.0592/1) log aY4-/aHgY2- aca2+ . aY4- aCaY2- ay4- = Kf . aca2+ Note: aY4- and Eind now also changes with aCa2+

2.) Metallic Indicator Electrode (Four Main Types) d) Metallic Redox Indicators i. Electrodes made from inert metals (Pt, Au, Pd) ii. Used to detect oxidation/reduction in solution iii. Electrode acts as e- source/sink iv. Example: Detection of Ce3+ with Pt electrode ½ reaction: Ce4+ + e- ↔ Ce3+ Eind responds to Ce4+: Eind = Eo – (0.0592/1) log aCe3+/aCe4+ v. Problems: - electron-transfer processes at inert electrodes are frequently not reversible - do not respond predictably to ½ reactions in tables

3.) Membrane Indicator Electrodes a) General i. electrodes based on determination of cations or anions by the selective adsorption of these ions to a membrane surface. ii. Often called Ion Selective Electrodes (ISE) or pIon Electrodes iii. Desired properties of ISE’s ‚ minimal solubility – membrane will not dissolve in solution during measurement – silica, polymers, low solubility inorganic compounds (AgX) can be used ‚Need some electrical conductivity ‚Selectively binds ion of interest

3.) Membrane Indicator Electrodes b) pH Electrode i. most common example of an ISE ‚ based on use of glass membrane that preferentially binds H+ ii. Typical pH electrode system is shown ‚ Two reference electrodes here ‚ one SCE outside of membrane ‚ one Ag/AgCl inside membrane ‚ pH sensing element is glass tip of Ag/AgCl electrode

develops due to the preferential adsorption of H+ onto the glass iii. pH is determined by formation of boundary potential across glass membrane At each membrane-solvent interface, a small local potential develops due to the preferential adsorption of H+ onto the glass surface. Glass Surface

Boundary potential difference (Eb) = E1 =E2 where from Nernst iii. pH is determined by formation of boundary potential across glass membrane Boundary potential difference (Eb) = E1 =E2 where from Nernst Equation: Eb = c – 0.592pH -log aH+ (on exterior of probe or in analyte solution) constant Selective binding of cation (H+) to glass membrane

iv. Alkali Error ‚ H+ not only cation that can bind to glass surface - H+ generally has the strongest binding ‚ Get weak binding of Na+, K+, etc ‚ Most significant when [H+] or aH+ is low (high pH) - usually pH ³ 11-12 At low aH+ (high pH), amount of Na+ or K+ binding is significant  increases the “apparent” amount of bound H+

v. Acid Error ‚ Errors at low pH (Acid error) can give readings that are too high ‚ Exact cause not known - usually occurs at pH ³ 0.5 c) Glass Electrodes for Other Cations i. change composition of glass membrane ‚ putting Al2O3 or B2O3 in glass ‚ enhances binding for ions other than H+ ii. Used to make ISE’s for Na+, Li+, NH4+

d) Crystalline Membrane Electrode i. Fluoride Electrode ‚ LaF3 crystal doped with EuF2 ‚ mechanism similar to pH electrode with potential developing at two interfaces of the membrane from the reaction: LaF3 ↔ LaF2+ + F- Solid (membrane surface) Solution \ the side of the membrane with the lower aF- becomes positive relative to the other surface: Eind = c – 0.0592 pF

Eind = c – 0.0592/2 pCa e) Liquid Membrane Electrode ‚ “Membrane” usually consists of organic liquid (not soluble in sample) held by porous disk between aqueous reference solution and aqueous sample solution. ‚ Membrane has ability to selectively bind ions of interest Example: Calcium dialkyl phosphate Liquid membrane electrodes At solution/membrane interfaces: [(RO)2POO]2Ca » 2(RO2)POO- + Ca2+ Organic (membrane) Organic (membrane surface) Solution (aqueous sample) \ the side of the membrane with the lower aCa2+ becomes negative relative to the other surface: Eind = c – 0.0592/2 pCa

e) Liquid Membrane Electrode ‚ Can design Liquid Membrane Electrodes for either cations or anions - cations  use cation exchangers in membrane - anions  use anion exchangers in membrane

f) Molecular Selective Electrodes i. Electrodes designed for the detection of molecules instead of ions ii. Gas sensing electrodes (or gas-sensing probes) ‚ Typically based on ISE surrounded by electrolyte solution - activity of ion measured is affected by dissolved gas - gas enters interior solution from sample by passing through a gas permeable membrane Gas effuses through membrane: CO2 (aq) ↔ CO2 (g) ↔ CO2 (aq) external membrane internal solution pores solution In internal solution, pH changes: CO2 (aq) + H2O ↔ HCO3- + H+ which is detected by ISE probe Overall reaction: CO2 (aq) + H2O ↔ H+ + HCO3- external internal solution solution Eind = c + 0.0592 log [CO2]ext

↕ (NH4)2CO + 2H2O + H+ ↔ 2NH4+ + HCO3- 2NH3 + 2H+ iii. Enzyme electrodes (or Biocatalytic Membrane Electrodes) ‚ General approach is to use an immobilized enzyme - enzyme converts a given molecular analyte into a species that can be measured electrochemically < enzyme substrate - Examples: H+  pH electrode CO2  CO2 gas sensing electrode NH4+  NH4+ ISE ‚ Example – Urea Enzyme Electrode - Principal: In presence of enzyme urease, urea (NH4)2CO is hydrolyzed to give NH3 and H+ (NH4)2CO + 2H2O + H+ ↔ 2NH4+ + HCO3- 2NH3 + 2H+ ↕ Monitor amount of NH3 produced using NH3 gas sensing electrode

Example 18: The following cell was used for the determination of pCrO4: SCE||CrO42- (xM), Ag2CrO4 (sat’d)|Ag Calculate pCrO4 if the cell potential is 0.386.