4 key operations UP/ DOWN 、 Esc and Enter Only 3 keys are needed for the rator to adjust all the parameters Simple Esc key Chips Programmable Intelsteer Power Saver
To preview the menus To select parameters UP/ DOWN Key Chips Programmable Intelsteer Power Saver
Enter To reach drilled-down menus To enter or exit parameters Esc To return to root menu To exit current menu Does not affect parameter selections ESC Chips Programmable Intelsteer Power Saver
Chips Programmable– Menu Levels Individual Parameter Adjustment Menu Levels 1Menu Levels 2Menu Levels 3 Main Menu Parameter Menu Programmer Options Soft Start Menu Optimisation Menu Special Application Menu Special Parameter Menu Standard Application Menu Menu Levels 4 ESCENTER Intelsteer Power Saver
Chips Programmable– Menu Levels Lost? Hit the “Esc” keys multiple times to return to Main Menu Main Menu Parameter Menu Intelsteer Power Saver
Main Menu Parameter Menu Main Menu Programmer Options Main Menu Download Parameters Main Menu Upload Parameters Copy Menu Download parameters Download the parameters to programmable chips’ memory. Verified during data conversion and transfer Upload parameters Upload from CPU memory to IntelSteer Power saver Verified during data conversion and transfer Intelsteer Power Saver
Test Communications Software Version Fault History - Erase Fault History - Interrogate Restore Default Parameters Power On Selection Parameters Monitor Mode Activate System Reset Save Data To Memory Restore Data From Memory Options for the Programmable Unit Intelsteer Power Saver
Check communication channels Check IntelSteer is connected to programmable communication units Ensure data cable is properly connected Options for the Programmable Unit Intelsteer Power Saver
Software Version Verify version compatibility between IntelSteer and CPU Send operator alerts about communication status Ensure IntelSteer and CPU software have consistent versions Options for the Programmable Unit Intelsteer Power Saver
Error Log List the most recent 6 error events Most recent error is always displayed before everything else Error log could be cleared Options for the Programmable Unit Intelsteer Power Saver
Restore Factory Settings Restore CPU setup Power selections parameter 2 power on selections Factory parameters Customer pre-set parameters) Options for the Programmable Unit Intelsteer Power Saver
Data storage and retrieval All parameters will be recorded Can setup multiple IntelSteer devices When revert the parameter, the old ones will be cancelled Options for the Programmable Unit Intelsteer Power Saver
Checking/Analysis mode and System Reset Display software start up data and inspect parameter settings Display optimization data Display motor’s efficiency and the angle of flow at the time of optimization Assist operators for special parameter setting changes System automatic reset after self booting check Options for the Programmable Unit Intelsteer Power Saver
Soft Start Features Chips Programmable Soft Start Soft Stop Pedestal Voltage Step Down Supply Frequency Current Limit Time / Level Kick Start Time / Level Arc-less Switching Plug Braking Relay 1 Function Relay 2 Function Intelsteer Power Saver
Modification Parametric Enter Standard Soft Start Ramp Up Ramp Up (s) 25 Up Ramp Up (s) 26 Standard Soft Start Ramp Up Enter ( Not choice Esc ) Chips Programmable Intelsteer Power Saver
Optimizations No Response zone Step up/down Optimal efficiency level Voltage Slip Tolerance Compensation function of voltage Voltage limitation function Dwell Timer Chips Programmable Intelsteer Power Saver
Non-reaction zone and step-type voltage rising/dropping Enhance system stability Non-reaction zone is a motor efficiency space in which IntelSteer electric appliance can not work Conduct step-type voltage rising/dropping from one angle of flow to the other to ensure for the stability of the system Step-type voltage rising/dropping can be adjusted for different applications Chips Programmable Intelsteer Power Saver
Optimal Efficiency Level The highest desired efficiency level of Intelsteer power Saver Factory setup at 70% - basically, 90% of the motors could reach this level If the efficiency level is set too high, it could prevent the motor to reach the highest voltage level To change voltage under the load-free condition Achieve the balance between enhance efficiency level and maintain voltage level To the two-step application, the best efficiency level can be setup to be minor, so as to make IntelSteer electric appliance more sensitive to the load change Chips Programmable Intelsteer Power Saver
Dead band setting Target Motor Efficiency Chips Programmable Dead Band And Step Up/Down Intelsteer Power Saver
Ø Ø + _ Conduct step-type voltage rising/dropping from one angle of flow to the other Chips Programmable Dead Band And Step Up/Down Intelsteer Power Saver
Motor efficiency % Motor Efficiency Objective Motor efficiency level Chips Programmable Optimal Efficiency Level Intelsteer Power Saver
voltage 0 % 100 % Voltage load Optimal Efficiency Level White 49% Red 70% Black 96% Chips Programmable Optimal Efficiency Level Intelsteer Power Saver
Voltage slide content and Compensation function of voltage Allow for minor proportion of motor’s rotating glide Increase power saving rate through allowing for lower voltage Be highly useful to some applications (e.g. wind-wheel type punch) with energy storage characteristic To injection machine (or similar applications), it is possible to inject a unit of voltage at the time of transient heavy load Chips Programmable Intelsteer Power Saver
VI Cos θ θ VI Sin θ VI Chips Programmable Optimal Efficiency Level Powerboss Intelsteer Power Saver
Voltage limitation function Used to set minimal voltage level To avoid the vibration of motors at the time of voltage compensation Chips Programmable Intelsteer Power Saver
Dwell Time Provide a delay interval during the commutation period of maximal voltage and optimization level Stabilized motors before going into optimization status Be highly useful to slip-ring motors Chips Programmable Intelsteer Power Saver
Connect With Intelsteer Power Saver At the time of connection, IntelSteer electric appliance is not necessarily to be electrified, but it will be better to do it. IntelSteer electric appliance can not be started if the programmer has not been setup to the test mode When the programmer is on, connect it to IntelSteer electric appliance, its system will be automatically reset Chips Programmable Intelsteer Power Saver
Power Source Electric core 9V DC Power Plug Extra power from the IntelSteer devices Chips Programmable Intelsteer Power Saver
Special Applications Timed Power Off Stored Energy Signal Optimisation Constant Voltage Chips Programmable Intelsteer Power Saver