Pipetting Pipetting involves drawing a liquid into a pipet and allowing liquid to drain from the pipet in a controlled manner. Pipetting is used to quantitatively.

Slides:



Advertisements
Similar presentations
Reading Graduated Cylinders Important Stuff!. Graduated cylinders are used to measure the volume of liquid samples and are available in many different.
Advertisements

Measurements with Range Uncertainty CHEMISTRY 11 UNIT 1.3.
Measuring Reading the Meniscus Always read volume from the bottom of the meniscus at eye-level. The meniscus is the curved surface of a liquid in a narrow.
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
INTRODUCTION TO PIPETTES
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Homework Assignment 01...is from Chapter 1. Problems assigned are: 4,5,9,10,12,15,22,29,31 (pages 29 ff) This assignment is due at class time Friday, Sept.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
Cautions! 1. Set pipet volume only within the range specified for that micropipet 2. Do not attempt to set a volume beyond the pipet’s minimum or maximum.
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
Measurements Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
Basic Laboratory Skills
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Volumetric Analysis Apparatus. The Volumetric Flask.
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Volumetric Analysis Apparatus. The Volumetric Flask.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
CHM 101/102 Laboratory Manual Water Hardness: Determination with EDTA General Chemistry 101/102 Laboratory Manual University of North Carolina at Wilmington.
Introduction to the most commonly used glassware and equipments in the lab.
CHEM General Chemistry I Laboratory - Fall 2011
Laboratory Glassware and equipment lab 2
Laboratory Techniques II: Titration
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 mLs of standarized NaOH solution. Make sure all.
How to do a Manual Titration. Rinse the Burette with 2-3 mL of standardized NaOH solution. Make sure all inside walls including the tip are rinsed. Discard.
Performing a titration A bluffers guide! Preparing a standard solution 4 Accurately weigh a weighing bottle, recording the mass 4 Add approximately x.
COMMON LABORATORY EQUIPMENT. FLASKS, BEAKERS, CYLINDERS Erlenmeyer flask beaker Erlenmeyer flasks and beakers are used for mixing, transporting, and reacting,
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
Identification of the common laboratory glassware, pipettes and Equipment . BCH 312 [PRACTICAL]
Chapter 16. In General…… What is the definition of volume and what is the basic unit? How do you use a graduate cylinder to measure volume? What are the.
Reading the Graduated Cylinder And All about the Meniscus.
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 cm 3 of water then with 2-3 cm 3 the solution.
A buret is used to deliver solution in precisely-measured, variable volumes. Burets are used primarily for titration, to deliver one reactant until the.
Reading Scales Section 1.3. Our Metric Rulers are Marked off in Centimeters 10 centimeters are in one decimeter.
Some Common Laboratory Glassware Please be careful when using glassware in the laboratory. Wet glassware and wet gloves are slippery. Always read a volume.
CHAPTER 1: Some Tools of the Trade Lab Purpose of Lab 1.1 Become familiar with the small volumes of solutions used in molecular biology Introduce.
Reading: Chapter 2 – an informative review Chemical measurements: Tools of the trade – hardware and labs VISIT THE LAB Safety Lab notebook Introduction.
4/24/ :54 PM Accuracy = of a measurement is how close that measurement is to the true or “exact” value EX: Standard weight = 5.00g 4.98g more accurate.
Experiment 1 Basic Laboratory Techniques Parts A, D, E, and an Unknown
Measuring Liquid Volume 2/9/ rd Grade. Question How can you find the volume of a liquid?
Measuring  Volume  Temperature  Mass. Graduated Cylinders The glass cylinder has etched marks to indicate volumes, a pouring lip, and quite often,
Preparing Solutions.
Week 1: Orientation Orientation Biological safety Chemical safety
Volume determination and density
Introduction to Titration Go to browse and set to full screen.
 Most common for holding liquids  Hold solids or liquids that are unlikely to release gas or splatter if stirred or heated.  Beakers come in several.
LABORATORY GLASSWARE AND EQUIPMENT LAB 2. Welcome Welcome to the chemistry lab! Chemistry is a lot of fun, but can be even more so if you are familiar.
Use and Maintenance of Micro-pipettes
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Lab Glassware Chemistry Ms. Gomez.
How to do a Manual Titration
Techniques in Molecular Biology 2017 Fall Lecture -2-
Measuring Volume.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Lab Techniques How to do a Titration.
Techniques in Molecular Biology 2017 Fall Lecture -2-
Measurement of Volume Chapter 20.
Liquid Volume Measuring Devices: The Graduated Cylinder and Buret.
Reading: Chapter 2 – an informative review
Use and Maintenance of Micro-pipettes
Introduction to Titration
How to do a Manual Titration
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Common Laboratory Glassware
Using a Pipette Filler Do NOT let the water get into the bulb
Laboratory Glassware.
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Using a Pipette Filler Do NOT let the water get into the bulb
Presentation transcript:

Pipetting Pipetting involves drawing a liquid into a pipet and allowing liquid to drain from the pipet in a controlled manner. Pipetting is used to quantitatively transfer exact volumes of a liquid from one container to another.

Mohr pipet Has graduations that allow it to deliver a range of volumes.

Serological pipets have no base mark (the graduations continue onto the tip) and are graduated to deliver. That means you let all the (measured) liquid in the pipet exit. Graduated to the tip

The volumetric pipet has a single graduation that allows it to deliver one specific volume accurately.

Reading a Pipette Total Volume Smallest Unit Increment

Determine the volume of solution in a pipet by reading the bottom of the meniscus at eye level. Record the volume using all certain digits and one uncertain digit. Certain digits are obtained from calibration marks. Uncertain digits (the last digit in the number) are estimated between calibration marks. What are the volumes in these pipets? Reading the Volume

Reading a Pipet

What is wrong with this pipet reading?

Dispensing Liquid Accurately transferring a specified volume of liquid from one container to another requires careful attention to detail. Pay special attention to the level of liquid in the pipet and carefully monitor the meniscus.

Using a Pipet

3-Way Safety Bulb

Using 3 way bulb Make sure there is enough solution in your beaker to completely fill the pipet. Never pipet a reagent directly from a reagent bottle. Carefully place the attachment of the three-way bulb over the mouth of the pipet.

1.Squeeze the air valve (A) and the bulb simultaneously to empty the bulb of air. 2. Place the tip of the pipet below the solution's surface in the beaker. Gradually squeeze the suction valve (S) to draw liquid into the pipet. 3.If the level of the solution is not high enough, squeeze the air valve (A) and the bulb again to expel the air from the bulb. 4.Draw up more liquid by squeezing the suction valve (S).

5.When the liquid is above the specified volume, stop squeezing the suction valve (S). 6. Do not remove the bulb from the pipet. 7.Do not allow liquid to enter the pipet bulb. 8.Use the expel (E) valve to release the solution.