INHALABLE PARTICULATE MATTER

Slides:



Advertisements
Similar presentations
EH Terminology Presented by QBE Loss Control Services.
Advertisements

An innovative tool for the review of health and safety work practices and the implementation of effective controls of particulate exposures.
SIZE-SELECTIVE SAMPLING OF PARTICULATE MATTER FOR OCCUPATIONAL HYGIENE
Chemical Substances TLV® Committee
NPPTL Year Month Day Initials BRANCH Overview of NIOSH-Approved Respiratory Protection Devices.
INHALABLE PARTICULATE MASS
Cyclones A CENTRIFUGAL FORCE IN AIR SAMPLING
Modification and Validation of Diesel Particulate Matter Cassette for PM-1.0 Sampling at Different Flow Rates Saulius Trakumas and Peter Hall SKC Inc.,
RESPIRABLE CRYSTALLINE SILICA
Determination of Size Fractions and Concentrations of Airborne Particulate Matter Generated From Construction and Demolition Waste Processing Facilities.
Use and Limitation of N-95 Filtering Facepiece Environment, Health and Safety Occupational Health and Hygiene 2009.
INHALABLE PARTICULATE MASS
ACGIH ® TLVs ® for Chemical Substances Committee Update Chair: Lisa M. Brosseau, ScD, CIH Associate Professor University of Minnesota School of Public.
Chemical Safety. Overview Chemical hazard classes Communication of hazards Routes of exposure Hierarchy of controls Special laboratory hazards.
ANOTHER EDITION OF…. DUSTY DEBBIE blasts particulate matters.
Variability of exposure and estimation of cumulative exposure in a manually operated coal mine.(Mamuya SH et al,2006;Ann Occup. Hyg.)
Fundamentals of Industrial Hygiene 6th Edition
Protecting Worker Health What in the World is Industrial Hygiene? by AIHA Student and Early Career Professionals Committee.
STANDARDS FOR EXPOSURE TO AIRBORNE CONTAMINANTS
Saulius Trakumas, Eddie Salter SKC Inc., Eighty Four, United States SKC Ltd., Blandford Forum, United Kingdom HIGH-FLOW PERSONAL SAMPLER TO MONITOR EXPOSURE.
Control of Airborne Respirable Dust Hazards: A Training Program for Underground Coal Miners The Penn State Miner Training Program University Park, PA
International Module W501 Measurement of Hazardous Substances (including Risk Assessment) Day 3.
Control of Airborne Respirable Dust Hazards: A Training Program for Underground Coal Miners The Penn State Miner Training Program University Park, PA
SAMPLING OPTIONS FOR THE EH&S PROFESSIONAL
Energy Facility Contractors Group Safety Working Group Industrial Hygiene / Industrial Safety Technical Team Dina Siegel, Los Alamos National Laboratory.
Respirators and Dust Hazards. What is Dust? How is Dust generated? What types of Dust are there? Why is Dust Control necessary? What are the Health Hazards.
Occupational Exposure to Metalworking Fluids Occupational Exposure to Metalworking Fluids Presented at the Occupational Hygiene Association of Ontario.
Distributors in over 50 countries We work as a single company
Respirators and Dust Hazards
INHALABLE SAMPLING Winnipeg – November 2003
Fundamentals of Industrial Hygiene 6th Edition
AIR SAMPLING AT WORKPLACES: SAMPLING STRATEGY, EQUIPMENT AND FACTORS AFFECTING THE QUALITY OF SAMPLES.
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Comparison of gravimetric PM data from the Harvard Impactors and Gent Stacked Unit PM 10 Samplers in Prague 2004 M. CIVIŠ 1, J. HOVORKA 1 and J. SCHWARZ.
Introduction to INDUSTRIAL HYGIENE
1 Saxony-Anhalt State Environmental Protection Agency Wolfgang Garche Bukarest EU-Twinning Project RO 2006 IB EN 09 Wolfgang Garche Saxony-Anhalt.
PLANT DESIGN.
RESPIRABLE DUST SAMPLERS
PRINCIPLES OF CONTROL ...a discussion of the strategies and methods available to achieve control of health hazards.
1 Setting Action Levels and Controlling exposure with Air Monitoring A review...
TOXICOLOGY OCCUPATIONAL HAZARDS CHEMICAL PHYSICAL ERGONOMIC PSYCHOLOGIC BIOLOGIC.
Particulate Matter Monitoring Exercise: Laboratory & Field Methods Lydia Scheer ITEP.
© Gully Howard Technical Limited HHSEG Topic Talk 28 October 2015 Workplace exposure to airborne dust – health effects & risk quantification Gully Howard.
Washington University School of Medicine Medical Student N-95 Particulate Respirator Training.
Principles of Carburetion. Carburetors function The carburetor works on Bernoulli's principle: the faster air moves, the lower its static pressure, and.
SAMPLING FOR RESPIRABLE CRYSTALLINE SILICA
AIR SAMPLING APRIL NEWSWORTHY TOPICS IN AIR SAMPLING 1. Hydrogen Peroxide-New OSHA Method 2. Total Particulates-New NIOSH Method 3. Elements (Metals)-New.
SKC Inc. The Basics of Air Sampling Step-by-Step.
Personal Air Sampling for Crystalline Silica Exposure
Alberta Construction Association Update November, 2013.
Elemental Impurities– An Update Kahkashan Zaidi, Ph.D. General chapters USP.
GREETINGS NEW ENGLAND AIHA & IAQA
AIR SAMPLING HEADLINES IN HYGIENE APRIL 2016.
Filter Media-PVC.
What in the World is Industrial Hygiene?
HYGIENE STANDARDS AND OCCUPATIONAL EXPOSURE LIMITS
Fundamentals of Industrial Hygiene 6th Edition
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Session 4: Air Pollution Measurements
ADEQUACY OF EXISTING AEROSOL SAMPLERS FOR MONITORING NORM EXPOSURES European ALARA Network 9th Workshop on Occupational Exposure to Natural Radiation.
Respirator Terminology
Ensures compliance with OSHA 29 CFR
RESPIRABLE DUST SAMPLERS DEFINITIONS, CRITERIA, AND OPTIONS
Classroom Foundry Combustion By-Products Aerosol Exposure
Respirators and Dust Hazards
Welding Fumes and Gasses
OSHA’s Respiratory Protection Standard 29 CFR
TOXICOLOGY.
Disaster Site Worker Safety
Disaster Site Worker Safety
Presentation transcript:

INHALABLE PARTICULATE MATTER SAMPLING OPTIONS FROM SKC INC

A GLOBAL DISCONNECT Global differences in definitions of workplace contaminants and standard sampling methods for those contaminants create a variety of problems.

GLOBAL DIFFERENCES IN DEFINTIONS Complicate international comparisons and sharing of data Make our profession seem illogical to lay people including legislators Contribute to differences in worker protection in different countries Complicate the choice of sampling equipment

GLOBAL DIFFERENCES IN SAMPLERS Result in considerable differences in exposure measurements when sampling the same contaminant under identical environmental conditions.

A COMMON SENSE APPROACH Since we are interested in health effects, researchers sought to design a personal sampler that would be based “on a biologically relevant definition of total dust, that is, one which represents the total of what the worker takes in through the nose and/or mouth during the act of breathing”. (Ann. Occup. Hyg. Vol. 30, 1986.)

HISTORICAL EVENTS A Move Toward Standardization ACGIH ISO CEN

HISTORICAL EVENTS In 1982, ACGIH appointed an ad hoc committee on Air Sampling Procedures (ASP) with the task of preparing recommendations for size-selective sampling that would lead to an approach for establishing particle size-selective TLVs for particulates.

HISTORICAL EVENTS In 1983, ISO published Technical Report 7708 giving definitions of particle size fractions corresponding to three regions of the respiratory tract. The fraction which would be measured would depend on the site of action of the particulate material under study.

HISTORICAL EVENTS In 1985, ACGIH published a report with a similar proposal to that published by ISO. In 1987, an ISO Working Group was established to revise TR7708 as an international standard and a CEN Working Group was established to produce a European standard.

HISTORICAL EVENTS In 1993, revisions to Appendix D of the ACGIH TLV booklet, “Particle Size-Selective Sampling Criteria for Airborne Particulate Matter” were adopted by ACGIH. Three particulate mass fractions were defined: inhalable, thoracic and respirable.

HISTORICAL EVENTS U.S. NIOSH nor OSHA have not officially endorsed the three new international particulate definitions in total. The only published method by U.S. government agencies using inhalable samplers is NIOSH 5700 for formaldehyde on dust specifying an IOM sampler or equivalent.

HISTORICAL EVENTS The Health and Safety Executive describes the use of inhalable and respirable samplers that meet the new definitions in MDHS 14/3, “General methods for sampling and gravimetric analysis of respirable and inhalable dust”.

HISTORICAL EVENTS Australia has embraced the new definitions of inhalable and respirable particulate mass in the new drafts of the Australian Standards for sampling and gravimetric determination of inhalable dust (AS 3640) and respirable dust (AS2985).

MOVING FORWARD Definitions Performance Specifications Samplers Exposure Limits

INHALABLE PARTICULATE MASS Defined as those materials that are hazardous when deposited anywhere in the respiratory tract Includes particulate matter that enter the head airways region including the nose and mouth Also includes materials that can produce systemic toxicity from deposition anywhere in the respiratory system.

INHALABLE SAMPLERS Meet the inhalability criterion when a personal sampler mounted on the body gives the same measured dust concentration and aerodynamic size distribution as that inhaled by its wearer, regardless of dust source location and wind conditions. Defined as having a 50% cut-point of 100 microns.

TRADITIONAL FILTER CASSETTES Do not effectively sample inhalable particulate matter They significantly underestimate the concentration of larger dust particles from 30-100 m. The inlets do not effectively capture the larger particles, particles adhere to the cassette walls and sample loss can occur when removing the filters.

INHALABLE SAMPLERS A personal sampler for inhalable particulate was first developed by Mark and Vincent in 1986 at the Institute of Occupational Medicine and licensed for manufacture by SKC.

IOM SAMPLER (SKC Cat. No. 225-70A) Exploded View

USING THE IOM SAMPLER SAMPLE LOGISTICS Load a 25-mm filter into the cassette using forceps and wearing gloves. Equilibrate the filter/cassette assembly overnight under controlled humidity conditions then weigh them as a unit. Allow the assembly to stabilize a few minutes before taking a reading.

USING THE IOM SAMPLER SAMPLE LOGISTICS Place the IOM cassette/filter assembly into the sampler body, screw on the cover cap, and connect to the pump. Calibrate the flow rate to 2 L/min using the IOM Calibration Adapter (Cat. No. 225-73) or by placing in a calibration chamber. Following sample collection, weigh the cassette/filter assembly again following the procedures described above.

USING THE IOM SAMPLER SAMPLE LOGISTICS Transport clips are available to transport the filter/cassette assemblies to the sampling site or the laboratory (Cat. No. 225-72A).

ADVANTAGES OF THE IOM Since the filter and cassette are weighed together, all particles which enter through the sampling inlet are part of the analysis. Any particulate dislodged from the filter due to accidental knocking, will be retained inside the cassette and weighed.

ADVANTAGES OF THE IOM The collection efficiency gives an acceptable match to the inhalability definition when worn on the lapel as a personal sampler. The performance is relatively independent of wind speed for particles with aerodynamic diameter up to and including 75 m.

WEIGHING ACCURACY OF IOM SAMPLES CONCERNS March/April 1999 AIHA Journal article discusses problems of water absorption by plastic IOM cassette and resulting instability of the tare weight RESPONSE SKC has changed the plastic material to address water. adsorption. Do not desiccate Equilibrate under controlled humidity conditions. Consider stainless steel cassettes.

NEW IOM RESEARCH BY U.K. HEALTH AND SAFETY LABORATORY Studied the use of porous polyurethane foams as size-selectors Placed in the inlet of the IOM sampler Allow for the collection of inhalable and respirable sub fraction using existing IOM samplers Followed by gravimetric analysis Used for a variety of particulates including bioaerosols

IOM SAMPLER WITH MULTIDUST FOAM DISCS Inhalable Respirable UNDER STUDY Thoracic PM10 Combination discs New Cassette with Elongated Inlet Required

PUBLICATIONS ON IOM BY HSE LAB HSE Lab Publication on Foam Discs, Project Leader: L C Kenny Journal of Aerosol Science, Vol. 30, No. 5, pp. 627-638, 1999 on sampling efficiency with low air movement AIHA Journal, Vol. 59, pp. 831-841, 1998 on sampling with foams for bioaerosols Methods for the Determination of Hazardous Substances 14, Health and Safety Executive, January 1997

NEW INHALABLE RESEARCH BY UNIV OF CINCINNATI Button Sampler -Alternative to the IOM sampler for inhalable dust Inlet is formed from a spherical shell with numerous, evenly spaced holes Holes act as orifices and provide multidirectional sampling capabilities Cat. No. 225-360

USING THE BUTTON SAMPLER SAMPLE LOGISTICS Unscrew the sampler inlet and remove the PTFE O-ring. Place a 25-mm filter on the stainless steel support screen, replace the 0-ring and the sampler inlet. A filter pore size of 1.0 m or higher is recommended due to the backpressure limitations of personal samplers.

USING THE BUTTON SAMPLER SAMPLE LOGISTICS Calibrate the Button Sampler to a flowrate of 4 L/min using the calibration adapter (Cat. No. 225-361) or by placing in a calibration chamber. After sampling, remove the filter for analysis. SKC offers a conductive plastic filter transport case for shipment to the lab. (Cat. No. 225-67)

ADVANTAGES OF BUTTON SAMPLER Closed-face inlet keeps out large particles 25-mm filter directly behind inlet avoids transmission losses in sampler Uniform distribution of holes minimizes sensitivity to wind velocity and direction Flow rate of 4 L/min for personal sampling increases sensitivity Can be used for personal or area sampling

PUBLICATIONS ON BUTTON SAMPLER BY UNIV OF CINCINNATI AIHA Journal, Vol. 61, 398-404, 2000 on performance characteristics Aerosol Science and Technology, Vol. 28, 247-258, 1998 on effects of wind velocity and direction AIHA Journal, Vol. 58,713-719, 1997 on field testing of sampler Atmospheric Environment, Vol. 29, No. 10, pp. 1105-1112, 1995 on design of prototype

CONCLUSIONS REPORTED For the Button Personal Sampler Effects of wind direction: No significant effects Effects of wind velocity: Lower than for IOM, GSP and 37-mm cassette Accuracy (direction-averaged): Better an 37-mm cassette, comparable to GSP, lower than IOM Precision (direction-specific): Equal or better than IOM, GSP, or 37-mm cassette

ABRASIVE BLASTING A NIOSH Health Hazard Evaluation indicated that current methods do not provide reliable measurements of worker exposure to lead and other contaminants during abrasive blasting in small confined spaces.

ABRASIVE BLASTING Current sampling methods using 37-mm cassettes often grossly overestimate exposure to very large, noninhalable particulate. In NIOSH HHEs, nearly all of the lead in the samples was due to grit that entered the cassettes due to rebound of grit in confined spaces.

JOURNAL ARTICLE APPLIED OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, Vol. 15, p. 776-772, 2000 on use of Button Sampler with screen for evaluating metal exposures among abrasive blasting workers at four US Air Force Facilities

OTHER INHALABLE SAMPLERS 7-HOLE SAMPLING HEAD Traditional European method using a 25-mm filter and cassette with an end cap with 7 equispaced inlet holes with flows of 2.0 L/min.

INHALABLE TLVs 2010 ADOPTED VALUES Acrylamide Alachlor Aldrin Asphalt Fume Azinphos-methyl Benomyl Beryllium Borate cpds, Inorganic Butylated hydroxytoluene Calcium sulfate Caprolactam Captan Carbaryl Carbofuran Chlorpyrifos Citral Coumaphos Cresol (all isomers) Demeton (and Demeton-S-methyl) Diazinon Dibutyl Phosphate 2,2-Dichloropropionic acid

INHALABLE TLVs 2010 ADOPTED VALUES Dichlorvos (DDVP) Dicrotophos Dieldrin Diesel Fuel Diethanolamine Dioxathion Diquat Disulfoton Endosulfan EPN Ethion 2-Ethylhexanoic acid Fenamiphos Fensulfothion Fenthion Ferbam Flour Dust Fonofos Glyoxal Hexahydrophthalic anhydride Iodine and Iodides Isobutyl nitrite Magnesium oxide Malathion Methyl demeton

INHALABLE TLVs 2010 ADOPTED VALUES Methyl parathion Mevinphos Mineral oil (excluding metal working fluids) Molybdenum (Metal and insoluble cpds.) Monochloroacetic acid Monocrotophos Naled Natural rubber latex as total proteins Nickel, Elemental, Soluble and Insoluble Cpds. Nickel Subsulfide 5-Nitro-o-toluidine p,p-Oxybis (benzene sulfonyl hydrazide) Parathion Particulates Not Otherwise Specified (now a guideline; not a TLV) Phorate m-Phthalodinitrile Ronnel

INHALABLE TLVs 2010 ADOPTED VALUES Silicon carbide, nonfibrous Sulfotepp (TEDP) Sulprofos Synthetic Vitreous Fibers (Continuous filament) Temephos Terbufos 1,1,2,2-Tetrabromomethane Tetraethyl pyrophosphate (TEPP) Thallium (and compounds, as TI) Thiram Trichlorphon Trimellitic anhydride Vanadium Pentoxide Wood dusts Xylidine (mixed isomers)

INHALABLE TLVs 2010 INTENDED CHANGES Carbon black Maleic anhydride Manganese (elemental and inorganic cpds., as Mn) Piperazine 4,4-Thiobis (6-tert-butyl-m-cresol) Toluene 2,4- or 2,6-diisocyanate (or as a mixture)

DATA CONVERSION?? TOTAL TO INHALABLE Aerosol Classification and Conversion Factor -Dust 2.5 -Mist 2.0 -Foundries 1.5 -Welding 1.0 -Smokes/fumes 1.0 Published by Werner et. al. in the Analyst, 121:1207

THE FUTURE OF SIZE-SELECTIVE SAMPLING More inhalable TLVs New thoracic TLVs Development of thoracic samplers Enhanced use of foams as pre-selectors