The Ordinary Notions of Mankind: The Research Basis of Waldram ’ s 0.2% Sky Factor Paul Chynoweth.

Slides:



Advertisements
Similar presentations
Designing House Extensions - draft Supplementary Planning Document (SPD) for consultation Eleanor Parker, Development Management.
Advertisements

WHEELOCK COLLEGE CAMPUS CENTER AND STUDENT RESIDENCE schematic lighting design anne k cheney lighting | electrical option advisor : dr. kevin houser courtesy.
111 Dr. Nihad Almughany University of Palestine Faculty of Applied Engineering and Urban Planning Dept. of Architecture 2 nd Semester Introduction.
16469 Low Energy Building Design Lighting Cameron Johnstone Department of Mechanical Engineering
Dimming Lights have a Bright Future South Ayrshire Council SUMMARY Advances in modern lighting technology, along with changes in regulations, mean that.
Chapter 10 Estimation and Hypothesis Testing II: Independent and Paired Sample T-Test.
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
Accessory Apartments Ordinance Serial No (B)
Space in the 21 st century home: Apartment standards in Ireland John Martin Principal Planning Adviser Dept. of the Environment, Heritage and Local Government,
The Concept of Daylighting Lighting buildings prior to the late 1800s relied chiefly on daylight from windows. Lighting buildings prior to the late 1800s.
Homeaboutpartnersnewsdownloads principlesin depthapplicationsteaching resourceslearning resourcesprinciples Natural Lighting Lighting standards Daylighting.
16469 Lighting and Daylighting Design. Energy Efficient Lighting Lighting accounts for a significant portion of energy use in commercial buildings We.
WILA SLL Masterclass 2013/2014 Energy Reduction Through Intelligent Lighting Design Duncan Abbott MSLL.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
Engineering Solutions Event  Six students will design a solution to an engineering problem.  Students will work as a team to design solutions.  Teams.
Aperture Placement & Area. Aperture Refers to any daylight source – Windows – Skylights – Openings – Transparent or translucent surfaces Placement and.
Prof. Dr. Meltem YILMAZ. Introduction  As a day light intake system, light shelves can be seen as more economical than the other systems.  Their features.
TURBULENCE IN THE LIBRARY. ABSTRACT: There is a small library in the south west corner of the second floor in the AJLC center. The 400 sq. ft. room features.
BAE SYSTEMS DESIGN PROJECT: DAYLIGHTING TECHNIQUES/ AFTERNOON DE-”LIGHT” EDSGN 100 Sec. 6 Team 3: David Young, Robert Vadella, Victoria Rodriguez, Phil.
{ Dementia Care: A Comprehensive Exploration of Certified Nursing Assistant Training.
CIVIL ENGINEERING DRAWING
Motor Control Theories
Good interior lighting facilitates the performance of daily activities (ADL) of the visually impaired elderly in their homes York, June 23th Frouck de.
Fraunhofer | Center for Sustainable Energy Boston, MA Schematic Lighting Design Xiaoyin Wu
Determination of System Equivalency – Starting note for WLTP IWG Meeting #8 in Pune, India Audi, EA-52, V2.0 WLTP-08-09e.
Opportunities for Continued Collaboration Between Licensing and Certifying Boards Starting a Dialogue National Alliance of Physician Competency January.
1 ISE Differences between office and factory layout Product  Offices process information  Factories produce things Physical environment  Offices.
Schematic Design Proposal Dan Rusnack 11/14/03 Lighting/Electrical option Thesis project The Hall Corporate Headquarters.
Energy surveying qualifications and procedures West Midlands Housing and Energy Conference 2007.
NIST Special Publication Revision 1
Artificial Lighting Design Task lighting for general purpose rooms involves the installation of light sources that will provide the optimum amount of.
Kwok Ngai Kan ES The benefits of proper lighting  To allow employees to comfortably see what they’re doing, without straining their eyes or their.
LIGHT. The Requirements of good Light Good light is essential for efficient vision. Poor lightening lead to straining and eye fatigue. The following light.
Local Assessment of Code of Conduct Complaints. 2 Background  On 08 May 2008 – the local assessment of Code of Conduct complaints was implemented due.
K. F. Chan (Mr.)ELEC INTERIOR LIGHTING DESIGN The basic aim of good lighting design should be to create a lighting installation that provides both.
Subcommittee on Heights, Massing, and Alternate Standards    Third Report – January 20, 2009 Planning & Zoning Commission.
DAYLIGHT CALCULATIONS. Components of the Natural Light :  There are three separate components of the natural light that reaches any point inside a building:
CLEAR ANC ANC ES. Two main elements of a Clearance 1.Visual examination.
 Have you ever put on brown socks with black pants?  Put on make-up, thought it looked blended and then gone outside and realized your face looks orange?
Chapter 221 What Is a Test of Significance?. Chapter 222 Thought Question 1 The defendant in a court case is either guilty or innocent. Which of these.
1/71 Statistics Tests of Goodness of Fit and Independence.
1 ISE Ch. 20: Vision and Illumination Performance on visual tasks depends on …  human vision  environment  task Human Vision acuity color vision.
1 Performance elements in budget and reporting process - Norway 5TH ANNUAL MEETING OF OECD SENIOR BUDGET OFFICIALS NETWORK ON PERFORMANCE&RESULTS – 28.
CDC Daylighting Analysis PNNL March 07, Methodology Daysim is used to analyze daylighting availability over a year course and glare condition.
Net Zero Energy Buildings – Lighting & Daylighting [NEED NEW COVER SLIDE]
Disciplinary Procedures
Schematic Lighting Design Natty Boh Building Baltimore, Maryland Eric Singley Penn State University Architectural Engineering.
1 The Future Role of the Food and Veterinary Office M.C. Gaynor, Director, FVO EUROPEAN COMMISSION HEALTH & CONSUMER PROTECTION DIRECTORATE-GENERAL Directorate.
The Built Environment CONS5C08. >>FACULTY OF TECHNOLOGY AND BUILT ENVIRONMENT Learning resources NZBC G7 Natural lighting NZBC G8 Artificial lighting.
Building Industry Authority Determination 2003/3 Commentary Paul Clements.
Services Currently Provided  FHA/ADA Inspections  Bank Draw Requests  Existing Condition Documentation Services.
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
TFT-LCD and Visual Performance 이현철. Nuclear I&C and Information Engineering Laboratory Preface  From the previous seminar, it.
S light in all directions (diffuse reflection) no glare spot Extent of glare related to the ratio of diffuse to specular (mirror-like) reflection.
Chapter 8. Electrical Systems
Lighting Wala Al-Zaharni Section /201.
Incandescent Light Bulb LUMEN DESIGN METHOD Where: N = E A F UF LLF N = number of lamps E = level of illuminance A = Area at working plane.
Seminar on Evaluation of Internal Control Systems
CORE AREA K. F. Chan (Mr.) MEBS6002.
Homework Questions.
Seunghui Cha1, Wookhyun Kim1
Climate Based Daylight Modelling
Figures & Tables from the textbook.
Chapter 8. Electrical Systems
SUMMARY OF INITIAL AIMING AND LEVELLING TOLERANCE ISSUE
Construction Studies Resources
Supplier Briefing Pack
IWG Worn tyres Tyre Industry work status July 17th 2019
IWG Worn tyres Tyre Industry work status July 17th 2019
IWG Worn tyres Tyre Industry work status July 17th 2019
Presentation transcript:

The Ordinary Notions of Mankind: The Research Basis of Waldram ’ s 0.2% Sky Factor Paul Chynoweth

An entitlement to “sufficient light” for the comfortable use and occupation of a dwelling house, or for the beneficial use and occupation of business premises, “according to the ordinary notions of mankind”. Lord Lindley, Colls v Home & Colonial Stores [1904] AC 179, HL. The Right to Light….. …..and the role of the expert witness

Sufficient light according to the ordinary notions of mankind?

Sufficient light according to the ordinary notions of mankind?

Sufficient light according to the ordinary notions of mankind?

Sufficient light according to the ordinary notions of mankind?

Illuminances recommended for general offices since 1930 Boyce, Human Factors in Lighting, 2003 (after Mills & Borg, 1999) 500 lux 150 lux

Origins of Waldram’s 0.2% “grumble point”?

“an assumption which the author has invariably applied in ancient light disputes for many years” (Waldram 1925). “It has no official status and has not been investigated by the NPL” (Waldram 1923). “a rough working rule would be that all parts of a room should have a minimum illumination of 1candle-foot” (Waldram 1909). Based on the assumed sky luminance of 1000 ft-candles, proposed a grumble point of 0.1% (Waldram 1909). Later changed to 0.2% in line with 500 ft-candle standard uniform sky. Proposed 0.2% minimum “at the worst-lighted working point in the room” (Charles Semon & Co v Bradford Corpn 1922).

Official support for the “grumble point”?

“it is more or less confirmed by the data of existing conditions in factories contained in the Home Office Report” (Waldram 1923). 1. “This assumption…received a valuable and welcome confirmation” from the Illuminating Engineering Society’s Report on the Daylight Illumination of Schools (Waldram 1925). 2. “These values may seem a little low according to text-books on artificial lighting, but in view of comprehensive tests in government offices, I do not expect to find the original standards varied” (Waldram 1928). 3.

Report on the Daylight Illumination of Schools (1914) Recommendation Minimum acceptable illuminance at the worst lit desk should be 0.5% SF. (Waldram was one of the six investigators) CIBSE guidance 1987: 2% DF min 5% DF av

Home Office Report on Existing Lighting Conditions in Factories (1915) Mean Survey Results 0.25% DF (Factories with side lighting only) 1.8% DF (Factories with combined roof & side lighting) 2.3% DF (Factories with roof lighting) “The extremely low value [of the 0.25% figure] demonstrates the comparative inefficiency of side lighting for floor or general illumination.” (Report, p. 40)

The Daylight Illumination Required in Offices (1931) Recommendation 0.2% SF should be taken as the threshold of adequate daylight for clerical work. Impartiality of the investigations? Dismissed as “much too low” by a subsequent investigation into lighting in government offices in Recommended a minimum of 5 ft-candles (50 lux) for clerical work.

CIE Resolution, Cambridge, 1931 “That at all parts of interiors where the daylight factor at table height (85 cm) is less than 0.2%, the daylight shall be regarded as inadequate for work involving visual discrimination”.

CIE Resolution, Cambridge, 1931 “That at all parts of interiors where the daylight factor at table height (85 cm) is less than 0.2%, the daylight shall be regarded as definitely inadequate for work involving visual discrimination. This is not recommended as a standard of adequate intensity of illumination.” Compare with the summary of this resolution in: Anstey, B. The Right to Light, Estates Gazette 1963, p. 38.

Post War Building Studies No The Lighting of Buildings (1944) No The Lighting of Office Buildings (1952) Kitchens:2% DF min Living rooms:1% DF min Bedrooms:0.5% DF min Offices:2% DF min (at reference point 12 feet from window)

Some concluding thoughts Percy Waldram’s central role in promoting the 0.2% / 1 ft-candle threshold. Generally unsupported by independent research from the 1920s & 30s. Inconsistent with contemporary guidance (CIBSE / BS). Ignores the distinction between task lighting (the subject of the right to light) and general room lighting. Effectively based on the position of the no-sky line? (an indication of general room lighting). Focuses on the internal, rather than the external, environment. 45 degree rule, 25 degree rule and the vertical sky component. Significance of human perceptions.

Reference Chynoweth, P., ‘Progressing the rights to light debate, part 2: the grumble point revisited’, Structural Survey, Vol. 23, No. 4, 2005, pp Available from: