Energy Efficient Glass Façade for building envelope Sri Ram.N – IGBC AP; GRIHA Trainer Saint Gobain Glass India 15 th June 2011.

Slides:



Advertisements
Similar presentations
Common Terminology Emittance Winter U-Factor or U-Value R-Value
Advertisements

Environmental Controls I/IG
Contents: Cover
Framing Assignment 4 Print SetSingle Family Dwelling SFD.
Sustainable Lighting Strategies
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
eQuest Quick Energy Simulation Tool
Façade Engineering Environmentally Sustainable Design.
A Comparison of Measure Avoided Cost Calculations using Utility TOU Load Shapes and DEER Hourly Measure Savings 14 March 2006.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
ASHRAE/ IESNA Standard 90.1 Future 90.1 Economic Analysis Methods Joseph J. Deringer, AIA Principal, The Deringer Group, Inc. Berkeley, CA ASHRAE Summer.
By: R.M. Chitranshi. ECBC With the background of high energy saving potential and its benefits bridging the gap between demand and supply, reducing environmental.
The Three Tiered Philosophy
Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Direct solar radiation is both a powerful environmental stress & renewable energy resource. The sun’s energy is most concentrated on the roof (spring through.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Chapter 6: Windows and Doors To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Heating energy calculation methods Anti Hamburg Lecture TTK-UAS.
Renewable Energy Project Analysis Course - Module 8 © Minister of Natural Resources Canada 2001 – Photo Credit: Pamm McFadden (NREL Pix) Passive.
Environmental Controls I/IG Lecture 12 Cooling Loads Cooling Degree Hours Energy Performance Ratings Annual Fuel Consumption Lecture 12 Cooling Loads Cooling.
Aperture Placement & Area. Aperture Refers to any daylight source – Windows – Skylights – Openings – Transparent or translucent surfaces Placement and.
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
BAE SYSTEMS DESIGN PROJECT: DAYLIGHTING TECHNIQUES/ AFTERNOON DE-”LIGHT” EDSGN 100 Sec. 6 Team 3: David Young, Robert Vadella, Victoria Rodriguez, Phil.
Tom Andrew Henry Poor Lumber/ Homeworks.  Objective: after this brief you should have a better understanding of ; 1. Materials that don’t primarily affect.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Windows. Huge variety of available building components and several important roles Thermally most important they admit solar radiation Advantageous in.
Glass technologies to improve sustainable performance
Concept of Energy Efficiency. Buildings, as they are designed and used, contribute to serious environmental problems because of excessive consumption.
PASSIVE SOLAR DESIGN. Design Techniques
Solar Radiation And it’s General Applications Nitin Jayswal.
Towards Net Zero Energy Buildings: Dynamic Simulation of office Building in Three Climate Zones of Europe Nusrat Jung 1,2, Jari Shemeikka 1, Risto Lahdelma.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
Identifying the Best of the Walling Alternatives Presented By: Manfred Braune, Technical Executive GBCSA On Behalf of: WSP Green by Design and ClayBrick.org.
Lecture 9: Windows and Daylighting Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract to the National.
Name of Building(s) or Project Speaker(s) Organization(s)
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Lecture Objectives: Finish with example modeling problems –Phase change thermal storage materials –Energy and airflow Interpret energy simulation results.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
Energy Design of Buildings using Thermal Mass Cement Association of Canada July 2006.
Fairconditioning Student Certificate Workshop
© 2011 Autodesk Vasari Talk – How accurate is Vasari? Wednesday 11 th October 2012.
Case application: Insulation and glazing, The Netherlands Harry Vreuls, NL Agency Workshop: Harmonization in Energy Savings Calculation: How To Fit International.
Announcement: The Course Test is Net week ! On Wednesday, October 12 It starts at 1 pm sharp.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Energy Efficiency in Jamaica’s Building Code:
(Multi-unit Residential Buildings)
Heat Loss and Gain Civil Engineering and Architecture
Building Environmental Systems
Technology in Architecture
WDMA Technical Conference Chicago, IL 28 June 2016
Heat gain in buildings: Other factors
Heat gain and heat loss in buildings
Heat Loss and Gain.
Conduction Cooling Loads
© Leigh & Orange Limited
Chapter 5A: HEAT GAINS THRU WINDOWS
Technology in Architecture
Concept of Energy Efficiency
Assessment of the Energy Savings Potential of Daylight Utilization and its Impact on a Building Energy Performance Hermano Bernardo Vienna, 2010.
WESTERN REGIONAL WORKSHOP
Thermal Impact of Different Interior Finishing Materials on Energy Consumption YOGESH JATAV
Technology in Architecture
Why we need to calculate heating load ?
Technology in Architecture
Technology in Architecture
Lecture Objectives Learn about Cooling Load Calculation
Presentation transcript:

Energy Efficient Glass Façade for building envelope Sri Ram.N – IGBC AP; GRIHA Trainer Saint Gobain Glass India 15 th June 2011

Glass for building envelope Indispensible construction material Freedom from conventional building shapes, with unmatched aesthetics. Transparent to visible light – daylighting of interiors Blending of interiors with exteriors Helps to maintain hygienic environment with easy maintenance Glass is 100% recyclable – Sustainable building envelope

Consumption Pattern RESIDENTIAL COMMERCIAL 80 % of Building Energy Consumption Source: Res :UNEP SBCI & TERI Study, Comm: IGDB Study

Key Performance Factors Lighting Energy Light Transmission Cooling Energy Total Heat Gain / Heat Transmission – SHGC or SF : Solar Heat Gain Coefficient or Solar Factor – U Value

Performance Parameter Light Factors

Visual Light Transmission (VLT) Percentage of incident light transmitted Percentage transmission depends Tint & Coating Light Transmitted out

Factors affecting Visual Light Transmission (VLT) Single Glazed Unit Clear VLT = 89% Single Glazed Unit Green tint VLT = 73% Single Glazed Unit Blue Tint VLT = 57% Single Glazed Unit Clear - Solar control VLT = 67% – 7% Single Glazed Unit Green - Solar control VLT = 54% – 6%

Energy Performance Factors Total Heat Gain / Heat Transferred -SHGC -U Value

UVVisible Far Infra RedNear Infra Red µ Electromagnetic Spectrum at Terrestrial Level TOTAL HEAT GAIN Heat Gain due to direct solar radiation Amount of heat Transferred due to temperature difference Total Heat Gain Wave Length

incident solar radiation 1#2# reflected energy re-emitted energy re-emitted energy directly transmitted energy Heat gain due to Direct solar radiation directly + re-emitted energy = S F / SHGC

Factors affecting SOLAR FACTOR (SF) or Solar Heat Gain Coefficient (SHGC) Single Glazed Unit Clear SHGC = 0.84 Single Glazed Unit Green SHGC = 0.56 Single Glazed Unit Blue SHGC = 0.56 Single Glazed Unit Clear –solar control SHGC = 0.15 – 0.68 Single Glazed Unit Green–solar control SHGC = 0.16– 0.47

Shading Coefficient Shading Coefficient (SC) = Solar factor of Glass Solar factor of 3.0mm Clear Glass (0.87) SC should be used if the solar value are through 3mm clear glass SF or SHGC should be used if it is direct solar value from sun Eg: Weather Files

Area = 1 m 2 T 1 = 1 o CT 2 = 0 o C U = 5.7 W/sqm K Amount of heat Transferred due to temperature difference U Value

Factors affecting U value Inert Gas Single Glazed Unit U value = 5.8W/SqmK Double Glazed Unit Low-e U value = 1.4 to 2 W/SqmK Double Glazed Unit Low-e + inert gas U value = 1.0 to 1.3 W/SqmK Double Glazed Unit U value = 2.9W/SqmK

ECBC – [Energy Conservation Building Code] Glazing Requirements for building envelope

ECBC Compliance Approach Prescriptive: component based approach (specs given for each) – Low Flexibility – Easy Approach Trade Off: system based approach (trade off between performance of envelope) – Moderate Flexibility – Comparatively Tedious Approach Performance Method: Whole Building Design Analysis Approach (overall building energy efficiency) – High Flexibility – Tedious Approach – High Detailing

Prescriptive Compliance Approach

Climatic zone map of India

WWR: Window to wall ratio WWR = Net Glazing area / Gross wall area – Net glazing area (window area minus mullions and framing) divided by – Gross exterior wall area (e.g., multiply width of the bay by floor-to-floor height) Spandrel Glass & Glass in front of dead wall are not considered as glass area Case 1 : WWR = X / Y Case 2 : WWR = (X+Z) / Y Z Z

Prescriptive Requirements ECBC Prescriptive requirements Light Transmission SHGC / U value

Light transmission Solar Control U Value 89% W/SqmK Clear Glass 73% W/SqmK Tinted Glass Greater than 20% Less than 0.25 Less than 3.3 W/SqmK ECBC Requirements Glass Performance Coated Glass with Solar / Thermal Insulation

Coating Technology - Glass Conforming to ECBC Compliance

Online Coating Manufactured during manufacturing of glass it self. Process of manufacturing known as pyrolysis Offline Coating Manufactured in a separate process (offline) by Magnetron sputtering on to raw glass COATINGTECNOLOGYCOATINGTECNOLOGY CVD Coating

Trade off Compliance Approach

Trade Off requirement Heat Gain Through Envelope – Covers: heat gain through: Wall, Fenestration, Roof EPF (Energy Performance Factor) – Calculate heat gain as per values specified by Prescriptive compliance for Glass, roof, wall – BASE CASE – Calculate heat gain as per actual performance of glass, roof wall – PROPOSED CASE – EPF of proposed case should be less than equal to base case

Trade Off Compliance: Envelope C = constant vale from ECBC table 12.1 to 12.4 – Appendix E

Performance Method Whole building Simulation Compliance Approach

Whole building Simulation Computer Simulation of annual energy performance using simulation software Hourly detailing & output result for base & proposed case is simulated Modeling & energy calculation is in accordance ECBC – Appendix D requirements encompassing details of: Design Model Space use / scheduling Building envelope Lighting HVAC SWH & miscellaneous loads

Choosing “Correct” Glass Energy EfficiencyDaylighting

Daylight Integration Sunlight aids in, – Reduction of Artificial lighting – Increasing Vitamin D level – Alleviate depression &anxiety – Eliminates Claustrophobic effect Glass, – Allows abundant natural sunlight – When compared to conventional brick-mortar building, daylight integration saves about 40 to 60% of the energy used for lighting – For a fixed lumen requirement, sunlight generates lesser heat in comparison to artificial lighting – reduce the A/C bill Light Heat ratio Heat Built up

Clear Glass Solar Control Coated Glass Light Transmission89%Light Transmission30% Average Lux Level430 lux Peak Lux level1680 lux Average Lux Level220 lux Peak Lux level670 lux Outdoor Lux level : 9000Lux Room Size : 4m X 5mWindow Size: 1.0mX 2.4m (WWR:20%)

Energy Efficiency

Air conditioned Spaces

Energy Analysis of air conditioned space CASESolar Factor U Value W/m2K Light Transmis sion HVAC Consumpt ion kWh Lighting Consumpt ion kWh Total kWh Savings / Year kWh 1. Single Clear % Base 3. Solar Control % Location: MumbaiFloor area : Sqft WWR – 20% Glass Performance on cooling & Lighting load Lower Solar Heat Gain coefficient significantly reduces the cooling Optimized light transmission of glass reduces lighting energy during daytime operation

Non - Air conditioned Spaces

Temperature Distribution Case 1: Double Glazed Unit – Clear Glass – Solar Factor : 0.71 – U value : 2.8W/SqmK Case 2: Double Glazed Unit – Single silver Low-e Glass – Solar Factor : 0.54 – U value : 1.8W/SqmK Case 3: Double Glazed Unit –Double silver Low-e Glass – Solar Factor : 0.32 – U value : 1.6W/SqmK Location :Mumbai Room Size :4m X 5m Glass Direction :South Glass Size :1.9m X 4.6m Over hang :1.0m Simulation :Ecotect Simulation hours :8760 Hrs

Temperature Distribution Duration Double Glazed Unit Clear Glass Double Glazed Unit Single silvered low-e Double Glazed Unit Double silvered low-e Temperature Range 20˚ – 30˚C Hours % 86%87.4%88.5% Increase in comfort hours Base122 Hrs299 Hrs Temperature 32˚C Hours % 11.7%11.6%10.9% Temperature Range 34˚ – 36˚ C Hours % 3.25%2.0%0.53% Comfort Temperature Range Discomfort Temperature Range

Go Green Do your little bit to the planet ! Every reduction in Unit of electricity (KwHr) means 1.4 kg (CO 2 e) per kWh* Every reduction in a single KWH, 1.4 Kg of CO2 emission is prevented Conversion factor includes GHG emission for handling, generation & transportation loss *Source: DEFRA – Dept of energy & climatic change