Distributor Meeting MEDICA November, 2009 Dr. Ariel Weisz R&D Department Metrolab, Argentina.

Slides:



Advertisements
Similar presentations
LABOMED, INC SPECTROPHOTOMETERS AND DIAGNOSTIC EQUIPMENT WWW. LABOMED
Advertisements

PRODUCT PRESENTATION QUANTUM2. EVOLIS QUANTUM, MODULAR SYSTEM FOR CENTRALIZED CARD PRODUCTION.
Introducing ChemWellTM
NEXGEN Four All automated microplate processors today can perform the steps required to process an ELISA microplate test However, most systems today operate.
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
CARBIDE INDUSTRIAL PRODUCTS. Do you want to know how to……. REDUCE PROCUREMENT COST REDUCE INVENTORY OPTIMIZE USAGE USER ACCOUNTABLITY REDUCE TIME LOST.
Nanodrop 2000c. Who is NanoDrop? Manufacture and Cell analytical laboratory equipment worldwide Used in biotechnology, pharmaceutical, and life science.
Thermo Scientific Konelab PRIME 60 and Konelab PRIME 30
The CuBiAn XC – A universal tool for your bioprocess analysis
Introduction to cobas c 311
Thermo Scientific Konelab 20XT and Konelab 20
Automated Immunoassays Multi-test immunoassays are the most widely used rapid test format – worldwide – ELISA / EIA (Assurance EIA, TECRA) – ELFA (Vidas)
YSI model 2950 Product Overview Giangarlo Scientific Company, Inc. 162 Steuben Street Pittsburgh, Pa
RQflex ® - the pocket laboratory for quantitative on-site measurements in agriculture and horticulture
Rev 4/28/06. SPIFE analytes, with multiple gel sizes for every workload Typical throughput – up to 14 SPE and 12 IFE gels in 8 hours Used in hundreds.
UR24 Process Refractometer
E-300 fully automated ELISA preparation and analysis workstation.
Introducing automated ELISA - ChemWellTM
DETERMINATION OF BLOOD GLUCOSE CONCENTRATION
SPECTROPHOTOMETRY.
Call Center – What Really Makes Sense? Call Center – ce este cu adevarat important?
PROCAL MULTI DISCIPLINE CALIBRATION SOFTWARE CALIBRATION PROCEDURE MANAGEMENT CONFIGURATION & CUSTOMISATION STAND-ALONE CERTIFICATE PRINTING.
AP900 Automated Programming System System General Corp. Introduction of System General AP900 Desktop Automated Programming System.
Introduction to Instrumental Analysis - Spectrophotometry
airQrate line of calibrators
Real-time PCR automated solution for food pathogen testing
Fire Detection Presentation
CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010.
The FlexTraining Total E-Learning Solution
© Process Analysis & Automation 2005 Short Course “I want to Automate that Process” Malcolm Crook.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
High Sensitivity Smoke Detection
Portfolio InCCA - Key Messages
Fully automated blood grouping system IH-1000
Colorimetry & Spectrophotometry.
Fortune 1000 companies Fortune 1000 companies Healthcare, Insurance, non- profit Healthcare, Insurance, non- profit FlexTraining Web-based Management System.
Microplate reader spectrophotometer. The Beer-Lambert Law A=abc Now let us look at the Beer-Lambert law and explore it's significance. A is absorbance.
P RINCIPLES OF C LINICAL C HEMISTRY A UTOMATION. A UTOMATION I N C LINICAL C HEMISTRY The modern clinical chemistry laboratory uses a high degree of automation.
Spectrophotometry.
Serum biochemical parameters TOTAL Protein assay Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015.
SPECTROPHOTOMETRY. Spectrophotometry Determines concentration of a substance in solution –Measures light absorbed by solution at a specific wavelength.
Biochemical instrumental analysis-14
AP Free Response Questions 2003
Pre- analytic Analytic Post- analytic  S pecimen collection  Specimen transport  Specimen quality  Result accuracy  Clerical.
The students should be able to understand & become familiar with: 1) General safety rules followed in Biochemistry laboratory 2)Safety with laboratory.
GenChem Week 11 Patient Project: Glucose Determination Today’s Agenda:  Review patient project.  Review understanding of absorption spectroscopy.  Develop.
CLINICAL CHEMISTRY Introduction to basic clinical chemistry BY BRUCE MUTUA.
Easy FlowTM and Smart FlowTM
George Avdikos, PhD Raymetrics S.A. 1. Executive Summary 2  Founded in Athens, Greece in 2002  Mainly professionals with extensive experience and postgraduate.
CLINICAL CHEMISTRY AUTO-ANALYZERS
prepared by Dr. Akaber Tarek Biochemistry Department Clinical Chemistry prepared by Dr. Akaber Tarek Biochemistry Department Clinical Chemistry prepared.
General Approach in Investigation of Haemostasis
NORMA ICON. INTRODUCTION - ICON Point of care ready Small footprint Smallest sample volume and lowest reagent consumption in the world Microfluidic components.
UV/VIS SPECTROSCOPY.
LIAISON®: Instrument Overview
Introduction to Basic Clinical Chemistry
RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY.
WP6 Patho-Stick and Patho-doc development and prototyping
Measurement of Analytes
Lab Activity 5 Biuret Method
AQT90 FLEX – the product 28/11/2018.
Experiment 4-4: Determination of Glucose in Blood Serum
Lab Activity 6 Biuret Method
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Piccolo Xpress™ Moderately Complex Training Demonstration
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
ARCHITECT cSystems OEM Reagent Training
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Presentation transcript:

Distributor Meeting MEDICA November, 2009 Dr. Ariel Weisz R&D Department Metrolab, Argentina

Metrolab is a company which designs and manufactures Clinical Chemistry Analyzers with its own technology. + reliable instruments to the global market + easy of use + effective after-sale service + competitive prices

Clinical Chemistry Analyzers The Principle: Spectrophotometry

Beer-Lambert Law concentration Absorbance T = P / P 0 A = log 10 (P 0 / P) A =  bc  : molar absorbtivity c: molar concentration

Colorimetry Samples Reactions Reagents MixIncubation (37°C) Measure

Double beam photometer reference detector sample detector beam splitter filter lamp reaction cuvettes A = log(R/S) R S

Dual photometer Front sample detector reference detector beam splitters filter lamp A F = log(R/S F ) A B = log(R/S B ) SFSFSFSF R Back sample detector SBSBSBSB

Clinical Chemistry Analyzers Applications and Measuring Methods

One Reagent End Point A Time Absorbance B R 1 +S Measure = A - B Metabolites Albumin Glucose Cholesterol Uric acid Triglycerides Total proteins

A2A2A2A2 Time Absorbance A1A1A1A1 R 1 +S R2R2R2R2 B1B1B1B1 B2B2B2B2 Measure = (A 2 -A 1 ) – (B 2 -B 1 ) Two-Reagent End Point Bilirubin IgA, IgG, IgM LDL, HDL Phosphorous

A2A2A2A2 Time Absorbance A1A1A1A1 R 1 +S B2B2B2B2 B1B1B1B1 Measure = (A 2 -A 1 ) – (B 2 -B 1 ) Fixed Point Kinetics ALP Creatinine Fructusamine Urea

Kinetics AnAnAnAn Time Absorbance A1A1A1A1 BnBnBnBn B1B1B1B1 R 1 +S Measure = rate A – rate B Enzymes Amylase CK, CPK GGT GOT GPT

Clinical Chemistry Analyzers METROLAB Instruments

// Metrolab history DRK PLUS DR

// Current Line - Main Instruments medium labsbig labs / hospitalssmall labs M test/hr M2300v4 M2300GL M1600DRv3 semiautomatic patients/day 240 test/hr patients/day 280 test/hr patients/day 600 test/hr veterinary

Clinical Chemistry Analyzers METROLAB 4000

Troughput: 550 test/hr without ISE 600 test/hr single reagent 450 test/hr double reagent 720 test/hr with ISE

Split reagent trays for effective carryover and interference control Methods are distributed, at operator’s will between two trays. In this way, interfering methods never come into contact in the same cuvette

Continuous sample load with coded sectors Positions can be assigned to normal samples or STATS, Handling priorities accordingly

Positive BCR identification of samples, reagents and sectors Coded sectors for instantaneous load Any coding system for samples Coded reagents and optional closed system Open channel support

Optional ISE module: Na +, K +, Cl - Direct serum readings Indirect urine readings (dilution 1:10) Integrated pack for simple operation Automatic electrode conditioning

User friendly software with different access levels Menu bar Main operation control tool bar Messages list Requests to operator bar Quick keys menu Current activity and summary Test in progress Reagents status report General status bar

Mixer in probe High efficiency mixing guarantees reliable data in double reagent systems and viscous media Shake time can be programmed for every method

72 on board cooled single reagents R2 30 ml R1 40ml Outer 30 ml Full size 70 ml

LIS Interface Connection - Customized Reports Metrolab 4000 Monitor PC Monitor PC Data Management System LIS ASTM Standard serial connection

Low Water Consumption 4 mL / test

// Current Line - Main Instruments medium labsbig labs / hospitalssmall labs M test/hr M2300v4 M2300GL M1600DRv3 semiautomatic patients/day 240 test/hr patients/day 280 test/hr patients/day 600 test/hr veterinary

Clinical Chemistry Analyzers METROLAB 2300 PLUS version 4

FULLY AUTOMATIC RANDOM ACCESS CLINICAL ANALYZER End Point Kinetics Immunoturbidimetry Coagulation ISE Barcode: Samples & Reagents Automatic Sample Dilution Mixer on Probe Quality Control Version 4

Samples 48 positions for primary tubes, tubes 75 to 100 mm (Ø 13 mm), accepts microtainers. Positive BCR identification of samples Test request through LIS Version 4

Reagents 48 positions cooled reagent Bar code for reagents Dual reagent capability 50, 30 and 20 mL containers 24 hours non stop cooling Version 4

Cuvette washing system 4-Step washing station Automatic cuvette check 6 mm light path PMMA cuvettes Version 4

Multifunction probe Mixer on probe Collision detector Capacitive liquid level detection Effective probe washing Version 4

Optical system Double beam 9 interference filters: 340, 405, 505, 550, 590, 650, 700 and 767 nm. Optional filters available (380 and 620 nm ) Version 4

Software User friendly Flexible Designed for the clinical analyst Continuous upgrade meeting your requirements Version 4

Easy service Open cabinet with only 4 screws Calibration through PC Version 4

// Current Line - Main Instruments medium labsbig labs / hospitalssmall labs M test/hr M2300v4 M2300GL M1600DRv3 semiautomatic patients/day 240 test/hr patients/day 280 test/hr patients/day 600 test/hr veterinary

Clinical Chemistry Analyzers METROLAB 2300 GL

Easy service Calibration through PC No cooling system No washing system No BCR No ISE METROLAB 2300 GL

Quick cuvette load Simple and Fast Double tray One tray in use (80 cuvettes) Preloaded tray ready to use METROLAB 2300 GL

Clinical Chemistry Analyzers Common Hints

Clinical Chemistry Analyzers Common Hints Pipetting principle Semi-disposable plastic cuvettes Low water consumption Probe technology Line style

Clinical Chemistry Analyzers Common Hints Proprietary Technology Proprietary software Open or closed customized systems Dedicated after-sales service

Clinical Chemistry Analyzers Next Steps… Modular electronics Reduce manufacturing costs Standardization

Clinical Chemistry Analyzers Thank you for your attention !!!