LABORATORY MANAGEMENT and QUALITY ASSURANCE. Introduction “The analytical laboratory provides qualitative and quantitative data for use in decision-making.

Slides:



Advertisements
Similar presentations

Advertisements

Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Quality is a Lousy Idea-
LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
Quality in Environmental Analysis Tuesday, June 27, 2000 Goldwater Center Room 487.
World Health Organization
Interpreting Your Lab Report & Quality Control Results
QA/QC Considerations for Sampling and Analysis Associated with EPA Method 1631 Chuck Wibby Wibby Environmental Seminar on Low Level Mercury Data and Analyses.
World Health Organization
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Quality Assurance.
Chapter 11 Quality Control.
Quality Assurance/Quality Control Policy
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Quality Assurance in the clinical laboratory
QA/QC FOR ENVIRONMENTAL MEASUREMENT Unit 4: Module 13, Lecture 2.
QA/QC FOR ENVIRONMENTAL MEASUREMENT
Unit #7 - Basic Quality Control for the Clinical Laboratory
Quality Assurance.
Quality Assessment 2 Quality Control.
Field Analysis Quality Control
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
VALIDATION METHODOLOGY
Laboratory Data Integrity Ashraf Mozayani, PharmD, PhD Texas Southern University Barbara Jordan-Mickey Leland School of Public Affairs Forensic Science.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical chemistry MLAB 243 Level 4 Lecture time: every WED 8 -10
HD 2007 Rule Diesel Fuel Sulfur Testing and Sampling Methods and Requirements US EPA Office of Transportation and Air Quality November 20, 2002.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
QA/QC and QUALIFIERS LOU ANN FISHER CITY OF STILLWATER, OK
Quality Control Lecture 5
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
Laboratory QA/QC An Overview.
Representative Sampling. Samples vs. Populations The population is the total or all of the possible answers we might get by sampling. All of the individuals.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
Why do we need to do it? What are the basic tools?
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Regulatory Issues in Laboratory Management
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Control Charts and Trend Analysis for ISO 17025
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Module 11 Module I: Terminology— Data Quality Indicators (DQIs) Melinda Ronca-Battista ITEP Catherine Brown U.S. EPA.
CLINICAL LABORATORIES THE ROLE: A science that uses sophisticated instruments and techniques with the application of theoretical knowledge to perform complex.
Scientific data storage: How are computers involved in the following?
Chapter 5: Errors in Chemical Analysis. Errors are caused by faulty calibrations or standardizations or by random variations and uncertainties in results.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
EQUIPMENT and METHOD VALIDATION
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Veterinary Practice Laboratory Unit 1 Chapter 5 Quality Control and Record Keeping Copyright © 2015 by Mosby, an imprint of Elsevier Inc. All rights reserved.
Quality is a Lousy Idea-
Unit #6 - Basic Quality Control for the Clinical Laboratory
Quality Assurance in the clinical laboratory
EPA Method Equivalency
Practical clinical chemistry
Quality is a Lousy Idea-
An Introduction to Quality Assurance in Analytical Science
EPA Method Equivalency
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
Choice of Methods and Instruments
Introduction To Medical Technology
Quality Control Lecture 3
▪Internal quality control:
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Presentation transcript:

LABORATORY MANAGEMENT and QUALITY ASSURANCE

Introduction “The analytical laboratory provides qualitative and quantitative data for use in decision-making. To be valuable, the data must accurately describe the characteristics and concentrations of constituents in the samples submitted to the laboratory. In many cases, because they lead to faulty interpretations, approximate or incorrect results are worse than no result at all.” –HANDBOOK FOR ANALYTICAL QUALITY CONTROL IN WATER AND WASTEWATER LABORATORIES, EPA 1979

Quality Assurance - Defined “Quality Assurance (QA) is a set of operating principles that, if strictly followed during sample collection and analysis, will produce data of known and defensible quality.” “The Accuracy of the analytical result can be stated with a high level of confidence.” –STANDARD METHODS, 18 th EDITION, 1992

Outline Laboratory Management Introduction to Quality Assurance Concepts

Laboratory Management Who should be involved in laboratory management and quality assurance?

Laboratory Management Everyone involved with the lab: –Person sampling –Person running the test –Person washing the glassware –Person doing maintenance on the instruments –Person interpreting the results

Laboratory Management Quality Assurance Program –Staff Organization and Responsibilities –Sample Control and Documentation –SOP for Analytical Methods & Procedures –Analyst Training Requirements –Equipment Preventative Maintenance –Calibration Procedures –Corrective Actions –Internal Quality Control Activities –Performance Audits –Data Assessment for Bias and Precision –Data Validation and Reporting

Laboratory Management Keys to Quality Assurance Program: –Documentation –Communication –Training –Cross-Training –Updating

Sample Control and Documentation A record keeping system (paper trail, chain of custody) should track samples before, during, and after analysis. Everyone involved needs to understand and utilize the system.

Sample Control and Documentation Efficiently process information through lab system while minimizing actual time spent recording data Keep it simple! –Collect only the information you need

Suggested Information - Field Date Conditions Collected By Site Code Comments: Hayfield Site Influent am HS IN 1Jim S. Sunny, 75F pH adjusted to <2 with nitric acid Grab sample

Suggested Information - Lab Date of analysis Laboratory technicians performing the analysis Results (including units) Analytical comments: based on need to know –Dilutions –Interferences encountered

SOP for Analytical Procedures Describes method in enough detail that an experienced analyst could obtain acceptable results.

SOP for Cleanliness Labware cleaning procedures should be documented and all persons involved should be trained.

Routine Cleaning Procedure Rinse glassware with tap water. Clean glassware with a solution of water and laboratory detergent. Rinse the glassware with an acidic solution –1.0 N HCl –6N HNO 3 for regulatory reporting of heavy metals Rinse glassware at least 3X with DI water.

Routine Cleaning Procedure (cont.) Glassware should be stored in a manner that prevents contamination from dust particles. Prior to analysis, rinse the glassware with sample to prevent contamination or dilution.

SOP for Instrumentation Maintenance Preventative maintenance is the key to optimal instrument performance. –Follow any maintenance program and guidelines suggested by the instrument manufacturer. –Instrument manual Reduces instrument downtime Service Contracts with Manufacturers

Analyst Training Sample Logging and Preservation Method SOPs Measuring –Use of Volumetric glassware (pipettes, graduated glassware) Weighing / Use and care of Analytical Balance Washing and Care of Glassware Operation of Analytical Instrumentation Data Handling and Reporting Quality Control Activities Safety

QUALITY ASSURANCE CONCEPTS

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Certification of Analyst Competence Demonstration of acceptable precision and accuracy for each analyst Minimum of four replicate analyses on a known standard –Look for acceptable accuracy and precision –Acceptable limits vary per analytical method ‘Demonstration of Capability’

What is Accuracy? Accuracy is the nearness of a test result to the true value.

What is Precision? Precision is how closely repeated measurements agree with each other. Although good precision suggests good accuracy, precise results can be inaccurate.

Imprecise and inaccurate Precise but inaccurate Accurate but imprecise Precise and accurate

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Standards What is a standard? –Solution containing a known amount of a specific substance –Example – 1.00mg/L iron standard

Standards How are standards used? –Instrument calibration –Instrument verification/accuracy check –Analyst training

Standards Analysis of Known Standard Solutions – Am I running the test correctly? –Verifies instrument, technique, and reagents

Standards Analysis of Known Standard Solutions – –How often? –Daily, every Sample ‘Batch’? National Institute of Standards and Technology –“NIST”

Standards Recovery of Known Additions – –Is my sample compatible with the test? –Identifies interferences and percent recovery Standard Addition ‘Spiked sample’

33 = 1.00 mg/L 50 mg/L Iron Standard 1.20 mg/L1.39 mg/L1.58 mg/L Correct?? 1.20 mg/L1.40 mg/L1.60 mg/L

34 X100 = 100 % 1.20 mg/L X100 = 99 % 1.39 mg/L 1.40 mg/L X100 = 98.7 % 1.58 mg/L 1.60 mg/L

Calibration with Standards Some instruments have built-in calibration curves, not necessary to calibrate Instrument without preprogrammed calibration curves –Prepare curve daily - OR –Whenever a new lot of reagents is prepared

Calibrations mg/L ABS

pH Calibration Curve mV pH

Standards “It’s what I always get” “It meets the permit limit” “I did”: –what the manual said –what tech support said –what you told me “It’s the same number the City of ____ gets” “I got what I expected” “I’ve run standards” “It’s a XXX brand instrument, the best!” “After 20 years you get a feel for it” “I’m a chemist” “It’s the same answer the lab got”

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Reagent Blanks Some reagents contribute color to a sample –Quantifies amount of reagent contribution to color formation –Monitors of purity of reagents On each new lot of reagents 5% of samples (Standard Methods)

Reagent Blanks

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Analysis of Duplicates Assesses precision 5% of sample need to be Duplicates –(Standard Methods)

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

What is a Control Chart? Quality control (QC) measuring device that visually represents the QC data Information in a control chart can aid in determining: –Probable source of measurement variability –Whether or not a process is in statistical control

How do Control Charts Work? If the chart displays other than random variation around the expected result, it suggests a problem with the measurement process. –Control limits are plotted on the chart, to assess whether this has happened. The measurement results are expected to remain within these limits.

Normal Distribution (Standard Deviation around the Mean) +2s+3s+1s-1s-2s-3sMEAN

Confidence Limits +2s+3s+1s-1s-2s-3s %

Confidence Limits +2s+3s+1s-1s-2s-3s %

Confidence Limits +2s+3s+1s-1s-2s-3s %

Control Charts A control chart is essentially a normal distribution flipped on its side A control chart is a plot of: –Test units on the vertical scale –Sequence of time on the horizontal scale

Control Chart +3s +2s +1s Mean -1s -2s -3s

Control Chart +3s +2s +1s Mean -1s -2s -3s Upper Warning Limit Lower Warning Limit

Control Chart +3s +2s +1s Mean -1s -2s -3s Upper Control Limit Lower Control Limit

How do Control Charts Work? Warning Limits –Set at ±2s –Standard Methods suggests: If 2 of 3 points are outside warning limits, analyze another sample. If it is within warning limits, continue. If it is outside warning limits, stop and troubleshoot.

How do Control Charts Work? Control Limits –Set at ±3s –Standard Methods suggests: If any point is outside control limits, analyze another sample. If it is within control limits, continue. If it is outside control limits, stop and troubleshoot.

How do Control Charts Work? A standard is measured regularly, and the results are plotted on the control chart. Control chart is a graph of concentration versus time.

+3s +2s +1s Mean -1s -2s -3s UC L LC L LW L UW L Control Chart Iron Standard, FerroVer Procedure Time

Constructing a Control Chart A control chart can be constructed in a variety of ways: –Graph paper –Spreadsheet problem, such as Excel

Constructing a Control Chart Analyze replicates of a standard. Determine the mean and standard deviation. –Calculate ±2s and ±3s Construct the control chart around the mean value –Use ±2s as the warning limits –Use ±3s as the control limits

Example – Iron Standard Replicates Samplemg/L Iron

Example – Iron Standard Replicates Calculate: –Mean –Standard Deviation (±1s) –±2s –±3s

Example – Iron Standard Replicates Calculate: –Mean1.000 –Standard Deviation (±1s)±0.010 ( ) –±2s±0.020 ( ) –±3s±0.030 ( )

+3s +2s +1s Mean -1s -2s -3s UC L LC L LW L UW L Control Chart Iron Standard, FerroVer Procedure Time 1.00 mg/L 1.02 mg/L 0.98 mg/L 1.03 mg/L 0.97 mg/L

Constructing a Control Chart First, set up a spreadsheet with columns for UWL, LWL, UCL, LCL, and sample results

Constructing a Control Chart Fill in values for UWL, LWL, UCL, LCL, and sample results

+3s +2s +1s Mean -1s -2s -3s UC L LC L LW L UW L Control Chart Iron Standard, FerroVer Procedure Time 1.00 mg/L 1.02 mg/L 0.98 mg/L 1.03 mg/L 0.97 mg/L

Constructing a Control Chart Fill in values for UWL, LWL, UCL, LCL, and sample results

Constructing a Control Chart Highlight data and create a graph

Constructing a Control Chart Format graph as necessary

Example Control Charts Control Analysis Results – Week 1 Samplemg/L Iron Mon1.003 Tues0.995 Wed1.006 Thurs0.988 Fri0.992 Sat0.992 Sun1.004

Example Control Charts Week 1 results display normal, random variation between the UWL and LWL.

Example Control Charts Control Analysis Results – Week 2 Samplemg/L Iron Mon1.008 Tues1.000 Wed0.996 Thurs0.993 Fri0.989 Sat0.988 Sun0.983

Example Control Charts Week 2 – Three or more points in one direction indicates a possible bias in analytical results. Investigate!

Example Control Charts Control Analysis Results – Week 3 Samplemg/L Iron Mon1.012 Tues1.000 Wed1.015 Thurs0.986 Fri0.994 Sat0.968 Sun0.997

Example Control Charts Week 3 – Data has a high degree of scatter to the LCL. Investigate!

Quality Assurance Quality Control Certification of Analyst Competence Recovery of Known Additions Analysis of Standards Analysis of Reagent Blanks Calibration with Standards Analysis of Duplicates Maintenance of Control Charts Quality Assessment Performance Evaluation Samples Performance Audits

Performance Evaluation Samples Standards provided by an outside agency –‘Blind’ Samples

Performance Audits Inspection to document sampling handling from receipt to final reporting of results –To detect any variations from SOPs –Checklists developed for each analysis type Sample entered in log book? Meter calibrated? Standard Analyzed? Etc., etc…..

LABORATORY MANAGEMENT and QUALITY ASSURANCE

References Standards Methods “Handbook for Analytical Quality Control in Water and Wastewater Laboratories” –EPA 1979 Hach Water Analysis Handbook “An Introduction to Standards and Quality Control for the Laboratory” –Barbara Martin, Hach Company