High Throughput Genotyping Utilizing a Versatile Extraction Platform T. Wayman 1, S. Mitchell 1,2, Y. Louie 1, C. Meadows 1, E. Lyon 1,3 1) ARUP Laboratories;

Slides:



Advertisements
Similar presentations
REAL TIME PCR ………A step forward in medicine
Advertisements

DNA was extracted from whole blood using 3 extraction instruments: Radius (Protedyne, Windsor, CT) and MagNA Pure (Roche Applied Science, Indianapolis,
Assessment of a high-throughput DNA melting analysis assay for rapid screening of gene variants in the ornithine transcarbamylase gene K. Sumner*, L. Hubley*,
Droplet digital PCR Overview and applications
SUMMARY SPECIFICITY of EIA IMMUNOASSAY for COMPLEMENT FACTOR Bb TESTING Igor Pavlov, 1 Nikol deForest 2, Julio C. Delgado 1 1 ARUP Institute for Clinical.
SNP Genotyping Without Probes by High Resolution Melting of Small Amplicons Robert Pryor 1, Michael Liew 2 Robert Palais 3, and Carl Wittwer 1, 2 1 Dept.
NEW EDUCATIONAL LAB: MEASUREMENT AND UNCERTAINTY EVALUATION OF NANOFLUID PARTICLE CONCENTRATION USING VOLUMETRIC FLASK METHOD M. Kostic,
COBAS TaqMan 48 Sales Brochure
BOHB APCCB LABORATORY USE OF THE ABBOTT MEDISENSE METER FOR BETA-HYDROXYBUTYRATE MEASUREMENT. GRD Jones, A Screnci, P Graham Chemical Pathology,
Chemometrics Method comparison
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
Tag-It TM Mutation Detection Kit for CFTR 70+6 Lorraine Fernandez August 6, 2008.
FilmArray™ - Nested Multiplex PCR for Multi-pathogen Screening
Assessment of Mutant Homozygosity in Gastrointestinal Stromal Tumors Michelle Wallander 1, Carlynn Willmore-Payne 1 and Lester Layfield 1,2 1 ARUP Institute.
Quality Assessment 2 Quality Control.
Simoa Accelerator Laboratory
The LightScanner ® System Achieve High Throughput Mutation Discovery and Genotyping.
Zlata D. Clarka, M. Laura Parnasb and Elizabeth L. Frankb
Development and Validation of a Novel Real-Time RT-PCR Assay to Distinguish Porcine Reproductive and Respiratory Syndrome (PRRS) Virus Subtypes with High.
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Understanding MYP Criteria
Vitamin D (Vit D) is produced endogenously by exposure of skin to sunlight, and is absorbed from foods containing or supplemented with Vit D. Vit D is.
Quality Control Lecture 5
Hana Al-Shatti Head of Molecular Laboratory Kuwait central blood Bank
Monitoring the Performance of Nucleic Acid Tests using Data Generated from EDCNet and DigitalPT Wayne Dimech, Darren Jardine, Thu-Anh Pham and the staff.
A RAPID AND INNOVATIVE METHOD FOR THE IDENTIFICATION OF THE COMMONEST G6PD ITALIAN MUTATIONS A. Minucci, L. Gentile, S. Rocchetti, C. Zuppi, B. Giardina.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
From the Seed Sample to DNA II: DNA Isolation, Quantification, & Normalization Beni Kaufman.
SUMMARY VALIDATION of the COMPLEMENT COMPONENT C1q RID ASSAY Igor Y. Pavlov, Julio C. Delgado ARUP Institute for Clinical and Experimental Pathology, Department.
Factor V Leiden Detection and Genotyping
ABSTRACT The purpose of the present study was to investigate the test-retest reliability of force-time derived parameters of an explosive push up. Seven.
Quality Assessment for Blood Screening Laboratories in Australia and the Asian Pacific. Darren Jardine and Staff of the National Serology Reference Laboratory,
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
The Factor II (Prothrombin) G20210A Detection and Genotyping
CONCLUSIONS Amended Abstract Detection of GBS Directly from ESwab Collected Samples Using the BD MAX™ GBS Assay Suzane Silbert, Talita T. Rocchetti, Alicia.
Mathematical Derivation of Probability
Crystiana Tsujiura (’14) and Judy L. Stone
Pakistan Society Of Chemical Pathologists Zoom Series of Lectures ZT 24. Quality Managent 1 Brig Aamir Ijaz MCPS, FCPS, FRCP (Edin), MCPS-HPE HOD and.
Comparison of WGA methods for genotyping fetal nucleated red blood cells for the application of non-invasive prenatal diagnosis Zhouwei Huang­­1, Angela.
COMBINATION OF CSF PROTEIN BIOMARKERS AND BDNF, IL10 AND IL6 GENOTYPES IN EARLY DIAGNOSIS OF ALZHEIMER’S DISEASE   Mirjana Babić Leko1, Matea Nikolac Perković2,
Clinical Validation of a New Triplex Real-Time Polymerase Chain Reaction Assay for the Detection and Discrimination of Herpes simplex Virus Types 1 and.
Tom Øystein Jonassen, Mona Holberg-Petersen, Einar S. Berg
Choosing the Best Urine Benzo Screen for Monitoring Adherence to Alprazolam or Clonazepam Maggie L Hopkins MD MBA1, Elisabeth Malmberg MS2, Bella Church.
John P. Jakupciak, Wendy Wang, Peter E
Maximizing the Amount of DNA Recovered: A Study of Mawi DNA Technologies’ iSWABTM-ID Collection Device for Forensic Science Application Boston University.
Practical clinical chemistry
Validation of a Commercially Available Screening Tool for the Rapid Identification of CGG Trinucleotide Repeat Expansions in FMR1  Grace X.Y. Lim, Yu.
EVAAS Overview.
Single-Color Digital PCR Provides High-Performance Detection of Cancer Mutations from Circulating DNA  Christina Wood-Bouwens, Billy T. Lau, Christine.
Extraction Procedure (2)
Robustness of Amplicon Deep Sequencing Underlines Its Utility in Clinical Applications  Vera Grossmann, Andreas Roller, Hans-Ulrich Klein, Sandra Weissmann,
Choice of Methods and Instruments
Christine Iwahashi, Flora Tassone, Randi J
Precision Profiling and Components of Variability Analysis for Affymetrix Microarray Assays Run in a Clinical Context  Thomas M. Daly, Carmen M. Dumaual,
Clinical Validation of a New Triplex Real-Time Polymerase Chain Reaction Assay for the Detection and Discrimination of Herpes simplex Virus Types 1 and.
Association of Clinical Status of Follicular Lymphoma Patients after Autologous Stem Cell Transplant and Quantitative Assessment of Lymphoma in Blood.
Evaluation of the Cepheid GeneXpert BCR-ABL Assay
Development and Clinical Utility of a Blood-Based Test Service for the Rapid Identification of Actionable Mutations in Non–Small Cell Lung Carcinoma 
Flexible Automated Platform for Blood Group Genotyping on DNA Microarrays  Sandra Paris, Dominique Rigal, Valérie Barlet, Martine Verdier, Nicole Coudurier,
Interferon λ 3 and 4 Genotyping Using High-Resolution Melt Curve Analysis Suitable for Multiple Clinical Sample Types  François M.J. Lamoury, Sofia Bartlett,
Tuda G Kemri/Wellcome Trust Research Program
Introduction To Medical Technology
Introduction To Medical Technology
Design, Development, Validation, and Use of Synthetic Nucleic Acid Controls for Diagnostic Purposes and Application to Cystic Fibrosis Testing  Todd M.
Application of COLD-PCR for Improved Detection of NF2 Mosaic Mutations
Development and Clinical Utility of a Blood-Based Test Service for the Rapid Identification of Actionable Mutations in Non–Small Cell Lung Carcinoma 
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Effect of Sample size on Research Outcomes
Validation of Roche LightCycler Epstein-Barr Virus Quantification Reagents in a Clinical Laboratory Setting  Margaret L. Gulley, Hongxin Fan, Sandra H.
Analytical Validation of a Highly Sensitive, Multiplexed Chronic Myeloid Leukemia Monitoring System Targeting BCR-ABL1 RNA  Justin T. Brown, Ion J. Beldorth,
Presentation transcript:

High Throughput Genotyping Utilizing a Versatile Extraction Platform T. Wayman 1, S. Mitchell 1,2, Y. Louie 1, C. Meadows 1, E. Lyon 1,3 1) ARUP Laboratories; 2) ARUP Institute for Clinical and Experimental Pathology and ARUP Laboratories; 3) Department of Pathology, University of Utah, Salt Lake City, UT Repeat rates were observed for the three systems were from consecutive time frames. Only one system was in operation at any given time as the primary extraction platform, so concurrent repeat data was not possible. The observed repeats for the PSS- SX96GC were rounded up to provide a more conservative measure of the repeat rate. As is reflected in the cost comparison a lowered repeat rate has a large enough effect on the cost to merit providing a highly conservative estimate by equalizing the repeat rates across the three systems. The comparison on the chart gives the percent difference between each of the three systems and the two different cost analysis for the SX-96GC. The percent differences demonstrate cost savings of the system on the left as compared to each of the systems on the top % Difference = ( Cost [top] - Cost [left] ) / Cost [top] Concentration PSS SX-96GC Roche MagnaPure Protedyne Radius Average (ng/uL) Range (ng/uL) – 52 CV15.1%6.6%42.6% A260/280 PSS SX-96GC Roche MagnaPure Protedyne Radius Average Range2.4 – – – 1.3 CV5.5%6.0%26.2% Spectrophotometric Data for the SX-96GC, MagnaPure, and Radius are from 12 samples multi-extracted across all 3 platforms. Each sample was extracted 8 times on each platform to make a total of 96 samples. Three different MagNA Pures each process a group of 32 to samples to make a full run of 96. Elution volume for all instruments is 100 uL. The instruments each differ in the number of pipetting nozzles on the instrument. This in conjunction with the data help further illustrate the performance of each instrument. The PSS SX-96GC uses one 96 well head for sample processing and one 12 well head for reagent setup. The Roche MagnaPure uses one 8 well head for sample/reagent processing. The Protedyne Radius uses one 24 well head for sample/reagent processing. Extraction Cost Difference MagnaPureRadius SX-96GC (equal rpt) Radius- 13.8% SX-96GC (equal rpt) %- 6.9% SX-96GC (low rpt) %- 8.8%- 1.9% Two separate costs were calculated for the SX-96GC. The first cost analysis for the SX-96GC assumes a repeat rate over time that is equal to that of the other two systems that ARUP has measured over the long term. The second cost analysis utilizes the repeat rate that was observed during the validation. Both were included due to the lack of long term measured repeat rates on the SX-96GC. Blood aliquot, reagent/ instrument setup, and cleanup time requirements for Technologists are very close and were equalized for the purposes of this cost comparison (50 minutes each). Observed Repeat Rate TimeframeRepeat Rate PSS SX-96GC10 validation runs4.0 % Roche MagnaPure 3 months10.6% Protedyne Radius 6 months11.2 % PSS SX-96GCRoche MagnaPureProtedyne Radius Reagent: MagDEA-HTS (PSS) Reagent: MagNA Pure LC DNA Isolation Kit I (Roche Applied Science) Reagent: MagNA Pure LC DNA Isolation Kit I (Roche Applied Science) 96 Sample Extraction32 sample extraction (x3)96 sample extraction 100 – 25 uL sample input evaluated 100 uL used clinically 200 uL sample input 200 – 50 uL sample input evaluated 100 uL used clinically 90 min extraction time60 min extraction time on each instrument 110 min extraction time 5 minutes PCR setup22 minutes PCR setup17.5 minutes PCR setup Any portion or orientation of 96 well plate can be extracted. Any portion of 96 well plate in columns can be processed. Horizontal half plate available Mfg: Precision System Science Matsudo-shi, Chiba Japan Mfg: Roche Applied Science Indianapolis, IN USA Mfg: Protedyne Corporation Windsor, CT USA Increased demand for molecular diagnostics testing has created the need to invest in higher throughput automation platforms. Due to increasing sample volumes, moving to a 96 sample extraction for moderate to high volume assays has been a priority of ARUP Laboratories. Without further automation, additional personnel will be required to extract, run, and analyze the increasing sample load. A 96 sample DNA extraction would ideally be able to increase efficiency and lower costs with existing personnel by allowing a larger batch size on multiple assays. In addition to increasing throughput it would be expected that any new extraction instrument will improve the results produced from the assay and be able to be utilized on multiple downstream analysis platforms. In investigating the SX-96GC (Precision System Science – Matsudo, Chiba Japan) ARUP has found a new platform and extraction reagent (MagDEA-HTS) to improve the efficiency of multiple endpoint detections through: increased quality of DNA, lower repeat rate, lower cost per test, and increased quality of result. Spectrophotometry Result Quality ARUP evaluated the SX-96GC against our existing extraction instruments; the Roche MagnaPure (Indianapolis, IN USA) and the Protedyne Radius (Windsor, CT USA). Three of the MagNA Pures at ARUP were utilized collectively to process 96 samples and provide a more direct comparison with the other instruments. DNA concentration & purity, result quality, repeat rate and costs were evaluated. Three of our highest volume molecular assays; FACV Leiden, Factor II 20210G>A, and the CFV30LA 23 mutation Cystic Fibrosis panel (Celera – Alameda, CA) were chosen for result comparison. FACV Leiden and Factor II 20210G>A were run on the LC480 (Roche Applied Science – Indianapolis, IN) with a laboratory developed assay. DNA used on the FACV and Factor II assays was from 12 samples multi-extracted across all three instruments. The melting curve analysis for the FACV and Factor II assays were performed on the Melt Wizard software (Department of Mathematics, University of Utah, Salt Lake City, UT). Derivative melting peaks pictured below are examples of Melt Wizard analysis windows. The clinical use of the Radius was limited to the FACV and PT PCR assays. The Cystic Fibrosis panel was run on the ABI 3130 (ABI – Foster City, CA). DNA used on the Cystic Fibrosis panel was extracted from the MagnaPure and SX-96GC. SX-96GCMagnaPureRadius FACV Factor II CF SX-96GCMagnaPure Observed Repeat Rate Cost Comparison Introduction Platforms Acknowledgements Special thanks go to Osamu Segawa, Tsutomu Asano and support provided by Precision System Science Japan for access to their expertise and advise during the evaluation of this instrument. Additional thanks go to Kerry Elenitoba-Johnson (ARUP Laboratories) for her help in providing resources to allow work on this project. Materials and Methods Conclusions DNA concentration of the SX-96GC was equal to or higher than the other instruments. DNA purity was very good due to low A280 readings. Result quality of the SX-96GC was equal in this comparison and above average for the length of its validation. Results produced concorded 100% with expected results across all three platforms. Repeat rates and extraction cost on the SX-96GC were both lower than existing platforms. The SX-96GC has performed very well and will make a valuable addition to ARUPs lineup of high quality extraction instrumentation. mutneg mut - Green curve is a failure of that sample negmut neg 20209