05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory.

Slides:



Advertisements
Similar presentations
Sub-ps bunch length measurements at the JLab FEL with coherent transition radiation (CTR) and “Martin-Puplett” interferometer Pavel Evtushenko, JLab 
Advertisements

Soft X-ray Self-Seeding
Adnan Doyuran a, Joel England a, Chan Joshi b, Pietro Musumeci a, James Rosenzweig a, Sergei Tochitsky b, Gil Travish a, Oliver Williams a a UCLA/Particle.
Spectral Resolution and Spectrometers
LC-ABD P.J. Phillips, W.A. Gillespie (University of Dundee) S. P. Jamison (ASTeC, Daresbury Laboratory) A.M. Macleod (University of Abertay) Collaborators.
Bunch Length Measurements in the E167 Experiment Ian Blumenfeld E167 Collaboration SLAC/UCLA/USC.
1 ILC Bunch compressor Damping ring ILC Summer School August Eun-San Kim KNU.
Coherent Radiation from High-Current Electron Beams of a Linear Accelerator and Its Applications S. Okuda ISIR, Osaka Univ Research Institute.
Linear Collider Bunch Compressors Andy Wolski Lawrence Berkeley National Laboratory USPAS Santa Barbara, June 2003.
EOS at SPPS Adrian L Cavalieri, David M Fritz, SooHeyong Lee, Philip H Bucksbaum, David A Reis (FOCUS Center, University of Michigan) Holger Schlarb (DESY)
A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang.
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Natural Broadening From Heisenberg's uncertainty principle: The electron in an excited state is only there for a short time, so its energy cannot have.
Approaches for the generation of femtosecond x-ray pulses Zhirong Huang (SLAC)
E. Schneidmiller and M. Yurkov (SASE & MCP) C. Behrens, W. Decking, H. Delsim, T. Limberg, R. Kammering (rf & LOLA) N. Guerassimova and R. Treusch (PGM.
2004 CLEO/IQEC, San Francisco, May Optical properties of the output of a high-gain, self-amplified free- electron laser Yuelin Li Advanced Photon.
P. Emma LCLS FAC 12 Oct Comments from LCLS FAC Meeting (April 2004): J. Roßbach:“How do you detect weak FEL power when the.
A. Zholents, July 28, 2004 Timing Controls Using Enhanced SASE Technique *) A. Zholents or *) towards absolute synchronization between “visible” pump and.
Bingxin Yang High resolution effective K September 22-23, 2004 High-Resolution Effective K Measurements Using Spontaneous.
1 A Grating Spectrograph for the LCLS Philip Heimann Advanced Light Source Observe the spontaneous radiation spectrum of the individual undulators Observe.
UCLA The X-ray Free-electron Laser: Exploring Matter at the angstrom- femtosecond Space and Time Scales C. Pellegrini UCLA/SLAC 2C. Pellegrini, August.
Spontaneous Radiation at LCLS Sven Reiche UCLA - 09/22/04 Sven Reiche UCLA - 09/22/04.
Workshop SLAC 7/27/04 M. Zolotorev Fluctuation Properties of Electromagnetic Field Max Zolotorev CBP AFRD LBNL.
John Arthur LCLS Diagnostics and Commissioning September 22, 2004 Summary of Related Topics from the Miniworkshop on.
Siegfried Schreiber, DESY The TTF Laser System Laser Material Properties Conclusion? Issues on Longitudinal Photoinjector.
X-rays are electromagnetic waves (like light) and have a wavelength about the size of atoms. From
FEL simulation code FAST Free-Electron Laser at the TESLA Test Facility Generic name FAST stands for a set of codes for ``full physics'' analysis of FEL.
07/27/2004XFEL 2004 Measurement of Incoherent Radiation Fluctuations and Bunch Profile Recovery Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
Solution Due to the Doppler effect arising from the random motions of the gas atoms, the laser radiation from gas-lasers is broadened around a central.
A. Doyuran, L. DiMauro, W. Graves, R. Heese, E. D. Johnson, S. Krinsky, H. Loos, J.B. Murphy, G. Rakowsky, J. Rose, T. Shaftan, B. Sheehy, Y. Shen, J.
R&D Towards X-ray Free Electron Laser Li Hua Yu Brookhaven National Laboratory 1/23/2004.
Free Electron Lasers (I)
Soft X-ray Self-Seeding in LCLS-II J. Wu Jan. 13, 2010.
Two Longitudinal Space Charge Amplifiers and a Poisson Solver for Periodic Micro Structures Longitudinal Space Charge Amplifier 1: Longitudinal Space Charge.
Adaphed from Rappaport’s Chapter 5
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
Max Zolotorev AFRD LBNL 1 Max Zolotorev CBP AFRD LBNL Radiation & Acceleration Tutorial.
Operated by the Southeastern Universities Research Association for the U.S. Dept. Of Energy Thomas Jefferson National Accelerator Facility FEL Bunch length.
Optimization of Compact X-ray Free-electron Lasers Sven Reiche May 27 th 2011.
X-RAY LIGHT SOURCE BY INVERSE COMPTON SCATTERING OF CSR FLS Mar. 6 Miho Shimada High Energy Research Accelerator Organization, KEK.
A.P. Potylitsyn, S.Yu. Gogolev
Max Cornacchia, SLAC LCLS Project Overview BESAC, Feb , 2001 LCLS Project Overview What is the LCLS ? Transition from 3 rd generation light sources.
Brookhaven Science Associates U.S. Department of Energy Longitudinal Space Charge Micro- bunching in SDL (DUV-FEL) T. Shaftan, L. Carr, H. Loos, B. Sheehy,
Basic Energy Sciences Advisory Committee MeetingLCLS February 26, 2001 J. Hastings Brookhaven National Laboratory LCLS Scientific Program X-Ray Laser Physics:
1.1 What’s electromagnetic radiation
P. Krejcik LINAC 2004 – Lübeck, August 16-20, 2004 LCLS - Accelerator System Overview Patrick Krejcik on behalf of the LCLS.
Optical Diagnostics of High- Brightness Electron Beams Victor A. Verzilov Synchrotrone Trieste ICFA AABD Workshop, Chia Laguna, Sardenia.
Can we see fringes coming from the interference of two lamps? …from the interference of two lasers? If the light is phase incoherent, no interference,
Synchrotron radiation: generation, coherence properties and applications for beam diagnostics Gianluca Geloni European XFEL GmbH.
The Next Generation Light Source Test Facility at Daresbury Jim Clarke ASTeC, STFC Daresbury Laboratory Ultra Bright Electron Sources Workshop, Daresbury,
UCLA Claudio Pellegrini UCLA Department of Physics and Astronomy X-ray Free-electron Lasers Ultra-fast Dynamic Imaging of Matter II Ischia, Italy, 4/30-5/3/
Accelerator Laboratory of Tsinghua University Generation, measurement and applications of high brightness electron beam Dao Xiang Apr-17, /37.
What did we learn from TTF1 FEL? P. Castro (DESY).
Transverse Coherent Transition Radiation (TCTR) Experiment First Ideas for a Measurement Setup Max-Planck-Institute for Physics Munich Olaf Reimann, Scott.
Applications of transverse deflecting cavities in x-ray free-electron lasers Yuantao Ding SLAC National Accelerator Laboratory7/18/2012.
Production of coherent X-rays with a free electron laser based on optical wiggler A.Bacci, M.Ferrario*, C. Maroli, V.Petrillo, L.Serafini Università e.
Ultrashort pulse characterisation
T. Agoh (KEK) Introduction CSR emitted in wiggler
Tunable Electron Bunch Train Generation at Tsinghua University
Two color FEL experiment
FCC ee Instrumentation
Application of a Streak camera at PITZ
F. Villa Laboratori Nazionali di Frascati - LNF On behalf of Sparc_lab
Soft X-Ray pulse length measurement
Beam size diagnostics using diffraction radiation
SASE FEL PULSE DURATION ANALYSIS FROM SPECTRAL CORRELATION FUNCTION
Status of FEL Physics Research Worldwide  Claudio Pellegrini, UCLA April 23, 2002 Review of Basic FEL physical properties and definition of important.
Linac Diagnostics Patrick Krejcik, SLAC April 24, 2002
Gain Computation Sven Reiche, UCLA April 24, 2002
Transverse coherence and polarization measurement of 131 nm coherent femtosecond pulses from a seeded FEL J. Schwenke, E. Mansten, F. Lindau, N. Cutic,
Presentation transcript:

05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory

05/03/2004 Need for speed Next linear collider projects require 1 ps bunch length X-ray Free-Electron lasers require high peak current to achieve lasing, which leads to 100 fs or less bunches LCLS is going to use 200 fs FWHM beam SPPS can already produce sub-100fs beams

05/03/2004 Short bunch diagnostics High power rf deflecting structures Electro-optic crystal diagnostics Coherent synchrotron radiation in THz region

05/03/2004 Fluctuations of incoherent radiation The method was proposed by M. Zolotorev and G. Stupakov and also by E. Saldin, E. Schneidmiller and M. Yurkov Emission can be produced by any kind of incoherent radiation: synchrotron radiation in a bend or wiggler, transition, Cerenkov, etc. The method does not set any conditions on the bandwidth of the radiation

05/03/2004 Theory Each particle in the bunch radiates an electromagnetic pulse e(t) Total radiated field is Fourier transform of the field is Power spectrum of the radiation is

05/03/2004 Average power Average power is The coherent radiation term carries information about the distribution of the beam at low frequencies of the order of  -1 coherent radiation incoherent radiation

05/03/2004 Difference between coherent and incoherent power is huge consider a Gaussian beam with  t =1 ps and total charge of 1 nC (approximately electrons) and Coherent to incoherent ratio At 1 THz: R  At 10 THz: R 

05/03/2004 High frequencies still contain information Power spectrum before averaging: Each separate term of the summation oscillates with the period  =2  /(t k -t m )~2  /  t Because of the random distribution of particles in the bunch, the summation fluctuates randomly as a function of frequency .

05/03/2004 Single electronElectron bunch e(t) Spectrometer ~10 fs~1 ps Example: incoherent radiation in a wiggler Spike width is inversely proportional to the bunch length

05/03/2004 Quantitative analysis We can calculate autocorrelation of the spectrum:

05/03/2004 Variance of the Fourier transform of the spectrum Fourier transform of the spectrum: Its variance: It can be shown, that the variance is related to the convolution function of the particle distribution:

05/03/2004 Some of the limitations Bandwidth of the radiation has to be larger than the spike width Transverse bunch size – radiation has to be fully coherent to observe 100% intensity fluctuations In order to neglect quantum fluctuations, number of photons has to be large

05/03/2004 LEUTL at APS

05/03/2004 Spectrometer Grating Grooves/mm600 Curv. radius [mm]1000 Blaze wavelength[nm]482 CCD camera Number of pixels 1100  330 Pixel size [  m] 24 Concave mirror curv. radius [mm]4000 Spectral resolution [Å]0.4 Bandpass [nm]44 Resolving power at 530 nm10000 Wavelength range [nm]250 – 1100

05/03/2004 Single shot spectrum Typical single-shot spectrum Average spectrum

05/03/2004 Spectrum for different bunch length Long 2-ps rms bunchShort 0.4-ps rms bunch Note: Total spectrum width (defined by the number of poles in the wiggler) is not wide enough for the short bunch.

05/03/2004 Spectrum correlation

05/03/2004 Bunch length From the plot the correlation width is 2 pixels. Frequency step corresponding to one pixel is 2.4·10 11 rad/s. Assuming the beam to be Gaussian, from equation we get

05/03/2004 Convolution of the bunch profile

05/03/2004 Convolution recovered from the measurements Convolution of the Gaussian is also a Gaussian with The Gaussian fit gives us

05/03/2004 Phase retrieval The amplitude and the phase information of the radiation source can be recovered by applying a Kramers-Kronig relation to the convolution function in combination with the minimal phase approach.

05/03/2004 Phase retrieval example

05/03/2004 Bunch profile Two different measurements (two sets of 100 single-shot spectra) FWHM  4ps

05/03/2004 Conclusions A technique for recovering a longitudinal bunch profile from spectral fluctuations of incoherent radiation has been implemented. It allows one to build the convolution of the bunch profile, then the Kramers-Kronig relation is used to recover the bunch shape. Although we used synchrotron radiation, the nature of the radiation is not important. Typically, analysis of many single shots is required, however one can perform statistical analysis over wide spectral intervals in a single pulse

05/03/2004 Conclusions An important feature of the method is that it can be used for bunches with lengths varying from a centimeter to tens of microns (30 ps – 30 fs) There are several important conditions for this technique. In order to be able to measure a bunch of length  t, the spectral resolution of the spectrometer should be better than 1/  t. Also, the spectral width of the radiation and the spectrometer must be much larger than the inverse bunch length