Emergency Lighting Code Review Presented by Iota Engineering LLC.

Slides:



Advertisements
Similar presentations
WAYNE DALTON OF SYRACUSE PRESENTS:
Advertisements

OSHA Office of Training and Education
Determining the Occupant Load
Design Constraints For Engineering Projects
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Universal Waste Management Training
2015 Update to OBC September 17, 2014.
PUMP STATION ELECTRICAL DESIGN
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
ELECTRICAL SYSTEMS Code Updates Energy, FGI, NFPA Maintain Branch Separation.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Presented by David Dagenais, SASHE, CHFM, CHSP Tuesday September 27 th, 2011.
Welcome to Sanforce. Introduction of Sanforce Sanforce Technology (Shenzhen) Co., Ltd is specialized in manufacturing and supply of emergency lighting.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Subpart E Means of Egress.
© 2011 Ericson Manufacturing, Willoughby, Ohio
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
FIRE ALARM SYSTEMS AND FUNDAMENTALS
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
The First Central Emergency & Standby Lighting System Combining Storage Batteries & Generator Input 1 1.
Emergency Action Plans
Business Owners and Managers and the Fire Code
Means of Egress and Fire Protection
Safety Training Presentation
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
Exit Routes and Fire Protection
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Means of Egress and Fire Protection
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Means of Egress Don Ebert- Risk Manager (509)
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Utilities & Engineering Department16 Blossom St., Boston Introduction to the Hospital Emergency Power Supply System (EPSS) Jason D'Antona,
2 SISCON TECHNOLOGIST PVT.LTD ISO 9001:2000 CERTIFIED COMPANY SISCON is a leading group of Electronics Company dealing with automation product. This company.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Practice Code Look Up Two Minute Drill #7
Fire Door Inspections Qualified Training
29 CFR NFPA Life Safety Code
Emergency Lighting Design, Inspection and Maintenance Requirements
Electrical Receptacle Testing
Stand-By Emergency Lighting Inverter
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
General Requirements of NFPA 101
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Fire Alarm Tech Practice Test # 16 NICET
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Stand-By Emergency Lighting Inverter
Area of Refuge It’s the Law!
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
City Council Meeting November 14, 2016
National Fire Protection Association Update
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Design Constraints For Engineering Projects
2008 Code Drills Health Care Facilities
2020 National Electric Code
Stand-By Emergency Lighting Inverter
Presentation transcript:

Emergency Lighting Code Review Presented by Iota Engineering LLC

Codes (IBC) International Building Code NFPA 101 (Life Safety Code) (NEC) National Electric Code

Codes Know which code/ revision applies Know the Authority Having Jurisdiction (AHJ) interprets and enforces codes There may be more than one Building inspector, Fire Marshall, Electrical Inspector, Liquor Authority IBC, NEC and NFPA develop codes, municipalities adopt

Performance Code requires at least 90 minutes of continuous operation Local or state codes may require longer run time/ higher light levels in certain applications NFPA 101 Chapter 5 & 6 Classification of Occupancy Must be operational within 10 seconds of loss of normal power Sources must be positioned to mark changes in the path of egress

NFPA 101 Chapter 6 Assembly Educational Day Care Health Care Detention Business Industrial Storage Hotels & Motels

Performance Exit access and exit discharge Must provide illumination out of the building to the “public way” Public Way = “ a street or alley or other parcel of land open to the outside air dedicated for public use” Or at least 50’ from the building The height and width must be at least 10’x 10’

NFPA “Every exit shall be clearly visible, or the route to reach every exit shall be conspicuously indicated. Each means of egress, in its entirety shall be arranged or marked so that a way to a place of safety is indicated in a clear manner.” Some AHJs require exits to be mounted at no more than 10’ AFG

Performance Must be arranged to provide an initial average of one foot-candle through the path of egress Minimum of.1 foot-candle 40:1 max to min Must have at least 60% of initial emergency illumination at the end of 90 minute run time

Testing 30 second test every 30 days Full 90 minute test once a year Written testing records must be kept Written records need not be kept if a computer based testing system is used and is capable of providing a history of code required tests. Must keep written records of failure/ faults and repairs Self testing units only require a visual inspection monthly

Dimmer Systems (NEC) Added to 2008 code Dimmer systems can be used as control device for energizing emergency lighting circuits Panel must be labeled that it is listed for emergency circuits

Methods Generator Inverter Bug eyes Battery packs

Methods Special attention should be given to the type of occupancy before choosing a method Refer to NFPA 101 Chapter 6

Generators Full light output to a dedicated EM fixtures Extended run time Must be maintained and tested according to code requirements Needs to be located to minimize hazards that could cause a failure of the system Start up time NFPA110 standard for generators

Generators On site fuel storage Must have fuel containment facility Noise and air pollution Requires factory start up Maintenance

Inverters Self contained Maintenance free batteries minimal environmental impact Some are fast transfer Operates all lamp types if fast transfer Operates multiple fixtures UPS does not meet the requirements for emergency lighting unless it is tested to and is listed for UL924

Inverters Larger units require factory start up Large inverters require large foot print Some battery types must be exercised Maintenance

Battery Packs Self contained Maintenance free Use same fixture for EM, “aesthetically pleasing” Must be on same branch circuit as AC ballast Instant on Vandal resistant

Battery Packs Single fixture application Fluorescent lamps only 7-10 year life

Bug Eyes Self contained Maintenance free batteries Must be connected to branch circuit supplying normal lights Available in different NEMA ratings Instant on Cheap

Bug Eyes Uneven light distribution Not aesthetically pleasing

Article 708 Critical Operations Power Systems (COPS) Added to NEC for 2008

Article 708 FPN No.1:Critical Operations Power Systems are installed in vital infrastructure facilities that if incapacitated would disrupt national security, the economy, public health or safety

Article 708 Provides the requirements for the installation, operation, control and maintenance of electrical systems with a high degree of reliability and resiliency to natural disaster and other threats

Article 708 Addresses homeland security issues for facilities that are “mission critical” These systems must continue to operate during the full duration of an emergency

Article 708 Police stations Fire stations Hospitals

Article 708 Many of the same rules that govern the installation, wiring and testing of emergency lighting power systems govern this article

Trends Some municipalities requiring higher light output for unit equipment Higher mounting heights Self Diagnostics Lamp/ ballast compatibility LED Lighting