Backflow Training Introduction to Backflow For Irrigation Systems.

Slides:



Advertisements
Similar presentations
Inspect Water Distribution EO Air Gaps, Vacuum Breaker, and Back Flow Preventers TP 8 50 min.
Advertisements

Typical Plumbing System
Fire Apparatus Pump Theory
Flammable and Combustible Liquid & Compressed Gas Handling and Storage
Fundamentals of Pressure Relief Devices
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Mountings & Accessories
Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
FLOW measurements.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Backflow Preventers. Cross Connection Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.
Water Based Sprinkler Systems 2 major different types of water sprinkler systems Wet pipe system Dry pipe system.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
SPILL – RESISTANT VACUUM BREAKER ASSEMBLY SVBA TESTIN G.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
Fluid Mechanics 07.
Welding and Cutting Safety Safety Unit Lesson 5. Oxy-Fuel Welding & Cutting Oxy-fuel welding and cutting are the most common causes of fires in the welding.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Reduced Pressure Backflow Why they fail. 1.Supply pressure of 100 psi pass through check valve #1 which has a minimum of a five pound spring which make.
State of Ohio Class A Drinking Water Operator Certification Program This course includes content developed by the Ohio Environmental Protection Agency,
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering AguaRed.
Direct Cross-Connection (a) A Clean-In-Place system is used to direct sanitizer from a reservoir to a recently cleaned milk tank. The sanitizer exists.
AL/MS AWWA Effective Backflow Prevention August 26, 2013 Sam McElroy, PE Civil Services, LLC (256)
Basic Hydraulics Irrigation.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
Backflow Prevention.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
Introduction Muhajir Ab. Rahim School of Mechatronic Engineering.
Chapter 10 Fluid Power Systems.
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
HVAC523 Basic Subsystems.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
SESSION THREE State of Ohio Class A Drinking Water Operator Certification Program This course includes content developed by the Ohio Environmental Protection.
Air Conditioning International Mechanical Code
International Backflow Perspective Australian Backflow Association Gary Ashwood 31 July, 2015.
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
5.1.6 Student Book © 2005 Propane Education & Research CouncilPage 1 Selection of proper dispenser transfer hoses, end valves and adapters relies on a.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Available Water Flow Meter Size Typical flow depending on size
Welding and Cutting Safety
Floatless Liquid Level Controllers. No float! Large connection opening is not necessary. No worry about inside clearance.
Presented by: City of St. Cloud. Water and Sewer Charges Base Fees: Service Availability—Fixed Fee Consumption Fees: Actual Usage—Variable Fee Other Fixed.
Backflow prevention Why the changes? Greater emphasis on protection of the water supply FDA also focuses heavily on product protection In some places it.
Boiler Safety Valve Regulations
Air condition installation
VALVES IN PIPE LINES.
CROSS CONNECTION CONTROL PROGRAM
Backflow Prevention Testers course 2 ½ day
Workshop developed by RCAP/AWWA and funded by the USEPA
Cross Connection Survey Training
Backflow Prevention and Cross Connection Control Update
WATER DEMAND (Chapter 24)
Cross-Connection Control and Backflow Prevention
Valves.
Typical Plumbing System
Backflow Devices 5 Types.
Boiler Safety Valve Regulations
Zurn Backflow Prevention- FCIS
Presentation transcript:

Backflow Training Introduction to Backflow For Irrigation Systems

Agenda Backflow definitions Hydraulics Degree of Hazard Types of Backflow Preventers Product Selection Approvals Installations

What is Backflow? The undesirable reversal of flow of water or mixtures of water and other liquids, gases, or other substances into the potable water supply from any source or sources.

Normal Flow

What is a Cross Connection? Any unprotected actual or potential connection between a public or a consumer’s potable water system and any other source or system through which it is possible to introduce into any part of the potable water system any used water, industrial fluid, gas, or substance other than the intended potable water with which the system is supplied.

What is a Cross Connection? A direct cross connection is subject to both back-siphonage and back-pressure. Usually a hard piped connection An in-direct cross connection is subject to back-siphonage only. Can be a potential cross connection

Hydraulics Back-pressure Back-siphonage Head Barometric loop Continuous vs. non-continuous pressure

Back-Pressure Any elevation of pressure in the downstream piping system above the supply pressure at the point of consideration which would cause a reversal of the normal direction of flow. Causes Change in elevation of the downstream piping. High pressure piping interconnect

Back-Pressure

Back-Siphonage Any decrease of pressure that causes a negative or sub-atmospheric pressure to exist in the upstream piping ahead of the point of consideration which would cause a reversal of the normal direction of flow. Causes Undersize piping Line breaks High water withdrawal rates

Back-Siphonage

Head The term “head” is used to describe pressure. One foot of head equals.433 pounds per square inch. In the backflow industry, the pressure loss through the valve is called “head loss”. All manufacturers express the head loss of their valves in units of pounds per square inch.

Head 27 3/4” of water generates a pressure of one pound per square inch (psi) 27 3/4” 1 psi

Barometric Loop A barometric loop is a horseshoe-shaped loop in a water line, that has a height greater than 33.9 ft. A very effective means of preventing backflow due to back-siphonage. Impractical due to physical size.

Pressure Non-continuous System cannot realize more than 12 hours of continuous pressure per 24 hour period. Continuous Anything that is not non-continuous!

Degree of Hazard Low Hazard Non-Health Hazard Pollution High Hazard Health Hazard Contamination

Types of Backflow Preventers used in Irrigation Systems Atmospheric Vacuum Breaker Pressure Vacuum Breaker Double Check Assembly Reduced Pressure Principal Assembly

Types of Non-Mechanical Backflow Preventers Air Gap A physical separation between the free flowing discharge end of a potable water supply pipeline and an open or non-pressure receiving vessel. An “approved air gap” shall be at least double the diameter of the supply pipe measured vertically above the overflow rim of the vessel. Never less than 1 inch.

Air-Gap

Atmospheric Vacuum Breaker Contains a float-check, a check seat, and an air inlet port. Water flow causes the float to close the air inlet port. When the flow of water stops... The float falls and forms a check valve against back-siphonage The air inlet port opens to allow air to enter and satisfy the vacuum.

Atmospheric Vacuum Breaker (AVB) Protects against a health hazard Back-siphonage condition only. Non-continuous pressure application. No more than 12 hours of pressure per 24 hour period

Atmospheric Vacuum Breaker

Anti-Siphon Valves Non-Testable Not USC Approved Usually not inspected

Pressure Vacuum Breaker (PVB) Contains... Independently-acting, internally-loaded check valve. Independently-acting, loaded air inlet valve located on the discharge side of the check valve. Two resilient-seated test cocks. Two resilient-seated isolation valves.

Pressure Vacuum Breaker Protects against a health hazard. Back-siphonage condition only. Continuous pressure application. Can realize pressure for 12 hours or more per 24 hour period.

Pressure Vacuum Breaker

Double Check Valve Assembly (DC) Contains two independently-acting approved check valves. Four resilient-seated test cocks. Two resilient-seated isolation valves.

Double Check Valve Assembly Protects against a non-health hazard. Back-pressure condition. Back-siphonage condition. Continuous pressure applications.

Double Check Assembly - Small

Double Check Assembly - Large

Reduced Pressure Principal Backflow Preventer (RP) Contains two independently-acting approved check valves. A hydraulically-operating, mechanically independent differential pressure relief valve located between the two check valves. Four resilient-seated test cocks. Two resilient-seated isolation valves.

Reduced Pressure Principal Backflow Preventer Protects against a health hazard. Back-pressure condition. Back-siphonage condition. Continuous pressure applications. The Ultimate in mechanical protection.

Reduced Pressure Assembly - Small

Reduced Pressure Assembly - Large

Operation of an RP Device

No-Flow Condition

Normal Flow

Backpressure with 2nd Check Fouled

Backsiphonage with 2nd Check Fouled

Troubleshooting an RP Assembly 1. Turn off number 2 shutoff valve 2. If discharge stops, problem is in 2 nd Check

Troubleshooting an RP Assembly 3. If discharge continues, induce flow by opening number four testcock 4. If discharge stops or slows dramatically, problem is in first check

Troubleshooting an RP Assembly 5. If discharge continues with no change, problem is in relief valve

Product Selection Guide

Specify the Proper Device for the Application We can communicate industry standards for degree of hazard, hydraulic and backflow conditions. Up to authority having jurisdiction to make the final decision.

Approvals and Listings Approvals FM Listings ASSE UPC UL CSA AWWA (Voluntary Standard - Certified to)

Installation Requirements Hydraulics Accessibility for testing and repair Indoor vs. Outdoor Freeze protection Vandal protection Relief valve discharge

Pressure Vacuum Breaker Installations

Double Check Assembly Installations Below Grade Above Grade

RP Assembly Installations

Irrigation Systems Issues Quick closing solenoid valves Create water hammer Cause RP to discharge Soft seated check valve between solenoid and RP Cause noise Install water hammer arrestor

Water Hammer Devices Soft Seated Check Water Hammer Arrestor

Key Terms Accessible Approved Assembly Approved Check Valve Isolation Backflow program Administrative Authority Annual test Certified Tester Containment Point of use