August 22, 2012 Dave Jones & Mike Gruenberg. The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will.

Slides:



Advertisements
Similar presentations
Using the ATTENDANCE MODULE of the SMS. How to Enter the Students Attendance in SMS.
Advertisements

Filing a Warranty Claim On-Line Claim Filing. 1.Upon successful login, the screen to the right appears. 2.To start a new warranty claim or check the status.
BUILDING EMERGENCY ACTION PLAN
EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Excavation and Trenching Module 5.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
What To Do In An Emergency Faculty and Staff Presentation SPSU Police Department.
Confined Space (Permit-required) Entry Supervisor.
Automating Result Verification
Users log on with a remote login facility. This is where a secure user name and password is entered.
MODULE 4 Odorants and Service Interruptions.
Historic Digimap Historical maps and data from the Ordnance Survey maps from the 1840s to the 1990s.
Exploded CAD Assembly Models © 2012 Project Lead The Way, Inc.
PERMIT REQUIRED CONFINED SPACES PERMIT REQUIRED CONFINED SPACES.
General Overview and Primary Functions. Introduction This presentation will help you quickly find some of the features of the GPSMAP295 and the procedure.
ESC MapPoint Features. Optimizing Routes This feature enables you to plot the most efficient route for each selected technician based upon the pending.
1 MAKE SMARTER BUYING DECISIONS WITH DTN PRICEPOINT™
Adding an Address To avoid adding duplicate addresses, Always use Find first. If you cannot find an address then add it. A warning should display if an.
INTERNATIONAL LABOR STANDARDS
Solutions Summit 2014 Discrepancy Processing & Resolution Terri Sullivan.
Designing and Installing Exterior Vapor Distribution Systems
Kenneth (Kenny) Mercado Division Vice President of Distribution Electric Operations Turning on the Lights.
The Utilization of GIS Technology at Northeastern REMC Presented By: Steven Weber, GISP Northeastern REMC (260)
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
White Knight Tap Locator HJ Arnett Industries, LLC Portland, OR
GIS and Mapping Capabilities GIS Division. DISPLAY YOUR TEXT AND GRAPHICS IN A WAY THAT CATCHES YOUR VIEWERS ATTENTION!! Geospatial, GIS, Geomatics? Geospatial.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 4 1 Chapter 4: Basics of Preventive Maintenance and Troubleshooting IT.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 12 Safety Information.
Engineering Matrix Megatec 2011.
Travel Speed Study of Urban Streets Using GPS &GIS Tom E. Sellsted City of Yakima, Washington Information Systems and Traffic.
Western Regional Gas Conference Effective First Response Techniques Lessons Learned Ron Six AEGIS Insurance Services 201/
© 2009 Bentley Systems, Incorporated Chris Collins D&C Manager Quantities.
IT Essentials: PC Hardware and Software v4.0. Chapter 4 Objectives 4.1 Explain the purpose of preventive maintenance 4.2 Identify the steps of the troubleshooting.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 4 1 Chapter 4: Basics of Preventive Maintenance and Troubleshooting IT.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
Childcare And Family Information Service Anne Lalley Choice Adviser.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Safety Information.
Active Corrosion Process Nisource – COH/CKY. Objectives  Understanding the terminology –Active Corrosion –& Suspected Areas of “Active Corrosion”  Developing.
) Main Menu: You can access all aspects of the database from this screen 2) Contacts: You can access the “contact database management” side of.
Second Harvest Finding Summer Meals for kids by using this Mapping Tool.
Copyright © 2006, Infinite Campus, Inc. All rights reserved. Behavior Letters & Referrals.
1 Quality Control for Field Operations. 2 Overview Goal To ensure the quality of survey field work Purpose To detect and deter interviewer errors and.
R Southwest Gas Corporation WRGC Customer Service Roundtable Discussion.
What are the New Safety Mandates? Presented by Mark Schaudt.
ProCal-Track Fast, Efficient Goods Inwards With Barcode Scanning Support.
Safe Schools Infinite Campus Interchange Windy L. Newton Office of Next Generation Schools & Districts, Division of Student Success.
Negotiating Intersections Chapter 10. Intersections Tips for Identifying an Intersection o Street lights and signs. o Roadway markings, such as a stop.
Exploded CAD Assembly Models Also called… Pictorial Assembly Exploded View Exploded Assembly Exploded Pictorial Exploded Assembly Presentation.
System Integration For Improved Customer Service City of Tallahassee Underground Utilities.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Automating Work Order Processes for Advanced Metering Infrastructure (AMI) Devices with Collector for ArcGIS and Portal for ArcGIS Subrahmanyam Pendyala.
Key Personnel. KEY PERSONNEL INSTRUCTIONAL GOAL The participant will understand the importance of roles, duties, and responsibilities for the supervisor,
Fire Service Incidents. Today’s fire service does much more than fight fires. The Fire Service has become the primary source of emergency response and.
The Troubleshooting Process. Hardware Maintenance Make sure that the hardware is operating properly.  Check the condition of parts.  Repair or replace.
Global Marketing © Chevron 2009 Rev. 1 Electrical Safety Awareness Plus.
Campus wide Ticketing Tool for UC Berkeley
Evacuation Plans For use in conjunction with 5-Minute Safety Talk.
How To Read MS811 Locate Request Tickets
Information to the Customer
October 2014 CenturyLink Design Service Repair Billing & Repair Billing Dispute Process Highlights.
IVG Driver Training Navigation Services.
DrayWatch Training November 2009.
On-Board Diagnostics Chapter 18 Lesson 1.
Ashley direct Replacement parts. Create my parts order
Southwest Gas Corporation Chris Sohus, Vice President/Operations
Weichert.com Admin Tutorial
Forging new generations of engineers
Forging new generations of engineers
CCP New Admission to Elwyn
CCP New Admission to Elwyn
CBMS Transformation Address Tip Sheet
Presentation transcript:

August 22, 2012 Dave Jones & Mike Gruenberg

The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will graphically display odor and priority/emergency orders  Automatically posted when created in our customer information system  Manually posted for all other odor complaints New orders posted to the map will appear as a bull's-eye Previous orders will appear as either a red flag or red push-pin as clear visual reference

The dispatcher will enter the address, city & state OR the cross streets. Verify the date range – three-months Evaluate the area around the new order  Check the attributes of the push-pins and flags within a 500 ft. radius.

If there are flags and/or pins and these orders were all inside odor complaints that showed repair, turn off, etc., and the underground leakage investigation was negative, then no further action is required for those addresses If the object on the map was a flag and the order was an outside odor call, then these addresses require an automatic recheck of the facilities Any pins that show no resolution, either research the original order to find the resolution and input that information into the system or route the address for a recheck

Sometimes an order will come in where there is no address in our customer information system, such as an intersection, all electric, propane address, etc. The dispatcher can add a location by two different methods  Type in the address if known  Click a location on the map and the Latitude/Longitude fields will be populated for the location

Computer generated orders will automatically update with field technician comments when completed Manually input odor locations must be updated by the dispatcher

Zoom into a specific area Determine the distance between two points Identify the boundaries of an outage Identify restoration within the outage boundary

To investigate the report of a natural gas odor or possible leak Company representatives respond to all reports of:  Natural gas leakage  Suspected leakage or odor complaints  Miscellaneous hazards relating to natural gas and/or natural gas appliances

Detection Methods Leak Migration Behavior Soil Types Policy Investigation Procedures  Training/Qualification Evacuation Procedure

Responding personnel will only perform procedures for which they have been trained and are qualified A leak investigation will not end until the leak/odor has been either:  Repaired, eliminated and/or graded/classified  Positively determined NOT to be natural gas

360° Leak Investigation Procedure Conduct the leak investigation by using a Search or Confirmation Instrument from the base of the structure to a point approximately 5 ft away from the base of the structure

General Two types of leakage instruments used:  Search  Confirmation Three types of Outdoor Leak Investigations:  Intersection  Single Family Residential or structure less than 250 feet wide  All others What to do when leakage is found

Types of instruments used  Search Instrument – Rover (only)  Confirmation Instrument Two types of Indoor Leak Investigations: 1- Inside structure and access is available 2- Inside structure and access is NOT available

Upon entering any structure on any leak/odor investigation, a Confirmation Instrument will be used to:  Check for the presence of gas inside  This is to provide for an early warning in the event there is gas buildup inside the structure FI units must not be used inside buildings, confined spaces or any structure or substructure where gas may accumulate. FI units are not intrinsically safe.

Dave Jones Mike Gruenberg