Mario Liuzza | Chris Loughnane | Ashley Pierce | Dan Spangler Bionic Ankle.

Slides:



Advertisements
Similar presentations
Measurement of forces directly for immediate feedback to athletes and coaches D. Gordon E. Robertson, PhD Emeritus Professor School of Human Kinetics.
Advertisements

FMRI Compatible Mechatronic Ankle Device Presented by: Danielle Doane, Ben Foss-Michaelis, Brendon Reedy, Karina Snow, and Brandon Teller Advisors: Professor.
2007 FIRST Robotics Conference Pneumatic Power Presented by: Raul Olivera, WildStang
Biomechanical Examination Parameters
ANKLE PROSTHETIC FOR THE LOWER LEG AMPUTEE TRIATHLETE DURING THE SWIM/TRANSITION EVENT Hello and good afternoon, my name is David Lyle. I am a licensed.
Kinetics (continued) Dr. Moran EXS 587 April 12, 2006.
Normal Gait.
Phases of the Gait Cycle And Determinants of Gait
ESS 303 – Biomechanics Ankle and Foot. Tibiofibular Joint Similar to radioulnar joint Superior tibiofibular joint Middle tibiofibular joint (interosseus.
Present Study Patient Specific Motion Modeling and Assistive Devices S Russell, P Sheth, B Bennett, P Allaire, M Abel University of Virginia, Motion Analysis.
Biomechanics of Walking for People with Lower Extremity Amputations
Biomechanics- Gait.
Analysis of a continuous skill – walking and running (gait)
Prosthesis Device for paraplegic people Jorge J. Corujo Javier Cruz Irvin De La Paz Francisco Torres.
NATURAL GAIT INDUCING TRANSTIBIAL PROSTHETIC LUCIA MELARA ROBERT SCOTT ALEXIS GARO EML 4551 ETHICS AND DESIGN PROJECT ORGANIZATION FIU DEPARTMENT OF MECHANICAL.
Fregis Effayong Mechatronic Rowan University Professor: Dr. Zhang.
1 CMPUT 412 Actuation Csaba Szepesvári University of Alberta TexPoint fonts used in EMF. Read the TexPoint manual before you delete this box.: AA A A A.
February 25, 2010 ARMS 1098-C 1 ODOS.  Team Leader Ed Brown – Junior, EET  Team Members Nathan Myers – Sophomore, EET Ben Ross – Junior, CE Lisa Li.
Modeling and Kinetics: Forces and Moments of Force* * Some of the materials used in this lecture are derived from: 1.Winter, D. A. (1990). Biomechanics.
Pneumatic Power FRC Conference 4/27/06
1 Gait Analysis – Objectives To learn and understand: –The general descriptive and temporal elements of the normal walking movement –The important features.
Gait Analysis – Objectives
Gait Analysis – Objectives
KINS 151 Website
Lecture 3 Control valves.
 Team Members: ◦ Pattie Schiotis – Team Manager (ME) ◦ Shane Reardon – Lead Engineer (ME) ◦ Dana Kjolner (EE) ◦ Robert Ellsworth (EE) ◦ Sam Hosig (CE)
POE FINAL EXAM REVIEW Spool-White Fall 2013.
INTRODUCTION ADJUSTABLE MECHANICAL STILTS INTRO PROBLEM DESIGN TESTING
Development of a Wearable 6-D Force Sensor for Human Dynamics Analysis Tao LIU Department of Intelligent Mechanical Systems Engineering Kochi University.
1 Block Diagramming Donald Heer 10/21/09. 2 Overview Block Diagrams Decomposition Interface Definitions.
NCSX Modular Coil Turning Fixture FDR. Background Modular Coil winding forms are cast structures which provide the foundation on which the coils are constructed.
Pneumatic and hydraulic actuation system (cont.)
The Gait Cycle:.
Terminology 101.

DARPA Robotics Challenge Day 1.
ZMP-BASED LOCOMOTION Robotics Course Lesson 22.
The MIT Leg Lab: From Robots to Rehab.
ANKLE JOINT Bony arrangement = stability
Introduction to Biped Walking
Warlocks 8/5/05 TMU Pneumatics on Robots u Simplified model Compressed Air Tank Geek Safety Glasses 60 lbs Pneumatic Cylinder Whoa! That’s a lot of force.
Gait Analysis – Objectives
 Support Events  Foot (Heel) Strike  Foot Flat  Midstance  Heel Off  Foot (Toe) Off  Swing Events  Pre swing  Midswing  Terminal swing.
Codey Lozier Christian Thompson Advisor: Dr. Mohammad Saadeh
Active Ankle-Foot Orthotic: Tethered Air Muscle P13001 Project Members: Nathan Couper- Mechanical Engineering Bob Day- Mechanical Engineering Patrick Renahan-
Engineering Analysis October 23, 2006 Team Moondogs Chris Culver Rahul Kirtikar Elias Krauklis Christopher Sampson Michael Widerquist.
ME 4182 Final Presentation Manual Trash Compactor December 06, 2006 Team Moondogs From Left Elias Krauklis, Mike Widerquist, Chris Culver, Chris Sampson,
ACTIVE ANKLE FOOT ORTHOTIC (AFO) VOICE OF CUSTOMER Design Project Management.
Valves In Industry (Part 1)
Warlocks 8/5/05 TMU FIRST Robotics 101 u Week 1) Gears, Pulleys, Sprockets, Bearings u Week 2) Motors & Controls u Week 3) Pneumatics u Week 4) Materials.
Date of download: 6/1/2016 Copyright © ASME. All rights reserved. From: An Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control.
FRC Pneumatics Nate Laverdure FRC Team 122. FRC Pneumatics, Nate Laverdure FRC Team 122 Everything I wanted to know aboutbut was afraid to ask Chief Delphi.
Air Cylinders Convert the energy contained in the compressed air
1 Gait Analysis – Objectives To learn and understand: –The general descriptive and temporal elements of the normal walking movement –The important features.
Enrollment No Name of Student: PAREKH KISHAN JAGDISHBHAI.
Parker Hannifin Chainless Challenge 2015/2016
Unit III Class II Pneumatic actuators.
TRANSDUCERS PRESENTATION BY: Dr.Mohammed Abdulrazzaq
Hönnun X Legged robot.
Control System Instrumentation
POWER GENERATION USING SPEED BRAKERS BY AIR COMPRESSION METHOD
Welcome.
Prosthetic limbs.
Pneumatic Power FRC Conference 4/27/06
P13001 Active Ankle Foot Orthotic: Air Muscle Tethered
Control System Instrumentation
The Articular System Joints
Joints of the Ankle.
TOPIC- Load cell A load cell is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being.
Presentation transcript:

Mario Liuzza | Chris Loughnane | Ashley Pierce | Dan Spangler Bionic Ankle

Background and need The challenge for anyone devising a new ankle is to make one that has a good degree of flexion (i.e. one that makes it easy to walk up and down hills, rotate etc) whilst at the same time retaining enough support for the person using it to feel confident in its stability Amputee Forum Moderator, In response to a query posed by the Bionic Ankle Group regarding the biggest complaints amputees have about their prosthetics In 2002, more than 110,000 lower extremities were amputated. That’s more amputations than there are people in Cambridge. And that’s only in the United States. Background and Need Background & Need ” “ -

Objective | Scope Objective Develop an actively controlled below-knee (BK) prosthetic that minimizes knee damaging torque by improving upon contemporary standards for stability in varying terrain. Scope To develop the base technology that allows the user to achieve stability on a variety of terrain. As stability is achieved between heel strike and foot flat, this will be the focus

Ossur Vari-Flex No Control System Single Axis of Rotation Weight: 0.89 lb Capacity: 365 lb Ossur ProprioFoot Actively Controlled Single Axis of Rotation Weight: 2.7 lb Capacity: 250 lb College Park TruStep No control system Anatomically incorrect second axis of rotation Weight: 1.43 lb Capacity: 300lb College Park Trustep Marketplace

What is missing?

Leg Member High Ankle Actuator Experiences loads of up to 700 N High Ankle Member 20º of dorsiflexion | 45º of plantar flexion Subtalar Axis Located 42° from the XZ plane and 23° from the XY plane. Subtalar Actuator Leaf Spring Subtalar Member 25-30° of inversion and 5-15° of eversion. Foot Design X Y Z

Considerations Weight, in lbf, of a 95 th percentile male 250 Safety factor 1.5x Maximum ground reaction force factor 1.5x Effective force, in lbf 562.5

High Ankle Axis Subtalar Axis Moment Analysis

High Ankle Kinetics RyRy W RxRx FxFx FyFy COM COP

Subtalar Kinetics

Max = 315 MPa FEA: Stress

Max = 315 MPa Max = % FEA: Strain

Material Selection Foot Body – Delrin Leaf Spring – Spring Steel Subtalar Member – 6061 Aluminum Leg Member – 6061 Aluminum High Ankle – 6061 Aluminum

Control System Sensing Actuation Control

Layout Options Strain Gauge Measures the unbalance in foot member Economical ($10-$100) Half Wheatstone bridge Configuration Pressure Pad: Dynamic force input Cost prohibitive ($10,000-$20,000). Dynamic Force Transducer Measures constant pressure output Price ($400-$1000) Size can limited the array of sensors used

LabVIEW Sensor RelationshipsActuator Reaction LabVIEW Block Diagram Retract Extend Subtalar High Ankle

Electric vs. Pneumatic Actuator Electric: -High Force or High Speed: Not Both -Support System: DC Power Source Pneumatics: -High Force and Speed (at high PSI) -Support System: DC Power Source + Compressed Air

Pneumatics Air Regulator 3 Position Valves Pneumatic Actuators – High Ankle: 7/8” Ø (60lbs 25 psi) – Subtalar: 9/16” Ø (25lbs 25 psi)

Test Fixture Full Test Fixture Simplified Design

Range of Motion

Future Improvements Install Flow Controls for the Actuators Implement More Sensors on the Bottom of the Foot Smooth Out the Control Responses Optimize Prosthetic Parameters Consider the option of a PLC Board

Bionic Ankle Questions? Specials Thanks To: Professor Greg KowalskiBrian Weinberg Pat and the Northeast Automation CrewJeff Doughty Kevin McCueJohn Doughty