LADDER DIAGRAM A ladder diagram is a means of graphically representing the logic required in a relay logic system. Rail Rung.

Slides:



Advertisements
Similar presentations
Unit 7 Discrete Controllers
Advertisements

PLC Timer Instructions
HYDRAULICS & PNEUMATICS
Dr. HABEEB HATTAB HABEEB Dr. HABEEB HATTAB HABEEB Office: BN-Block, Level-3, Room Ext. No.: 7292 UNITEN.
Programmable Logic Controller PLC
Programmable Logic Controllers
PROGRAMMABLE LOGIC CONTROLLERS
Ladder Logic PLC Programs are made up of combinations of AND; OR; NAND; NOR; and other gates, along with timers, inputs, outputs, counters, comparators,
EUT 1040 Lecture 10: Programmable Logic Controllers.
Switchgears Control Using SCADA System Based on PLC
1 The University of Jordan Mechatronics Engineering Department PLC: Programmable Logical Controller.
PROGRAMMABLE LOGIC CONTROLLERS
Introduction To Programmable Logic Controllers
FUNCTION OF OUTPUT CONTROLLER AND APPLICATION
PLC OPERATION & PROGRAMMING Dr. ONUR TOKER. What is a PLC ? PLC is a computer system controlling a process. inputs - the keyboard is analogous to a proximity.
Programmable Logic Controllers ( Definition according to NEMA standard ICS3-1978) 4/19/2017 A digitally operating electronic apparatus which uses a programming.
Lecture 4: Programmable logic Controllers
Programmable Logic Controller Internal Operations
Programmable Logic Controllers
Chapter 19 Fundamental PLC Programming
Module 2: Hardware and Terminology
Lecture 6: PLC: Timers and Counters
PLC: Programmable Logical Controller
Logic Functions OR Operation
Timers.
LADDER DIAGRAM A ladder diagram is a means of graphically representing the logic required in a relay logic system. Rail Rung.
Chapter 10 PLC Processors.
1 FUNDAMENTOS DEL CONTROLADOR PROGRAMABLE. 2 ¿QUE ES UN CONTROLADOR PROGRAMABLE? PROGRAMMABLE CONTROLLER ENTRADAS A solid state device that controls output.
PLC introduction1 Discrete Event Control Concept Representation DEC controller design DEC controller implementation.
PLC: Programmable Logical Controller
Memory Layout and SLC500™ System Addresses. Processor Memory Division An SLC 500 processor's memory is divided into two storage areas. Like two drawers.
Memory Layout and SLC500 System Addresses. Processor Memory Division An SLC 500 processor's memory is divided into two storage areas. Like two drawers.
Chapter 8.
Pneumatics.
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
Implementing software in IEC Languages in IEC IEC uses the following languages Instruction List – Assembly level programming using.
Chapter 10 Advanced Programming, PLC Interfacing, and Troubleshooting
Copyright © 2002 Delmar Thomson Learning Chapter 10 PLC Processors.
Logic Functions and Symbols
PROGRAMMABLE LOGIC CONTROLLER
Timers and Counters by Dr. Amin Danial Asham. References  Programmable Controllers-Theory and Implementation, 2nd Edition, L.A. Bryan and E.A. Bryan.
PLC PROGRAMMING.
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
1 RLL: Relay Ladder Logic CONTENTS 1. PLC operation 2. PLC programming 3. Ladder logic 4. Memory and gates.
PLC ARCHITECTURE – Memory 2 by Dr. Amin Danial Asham.
Traditionally ladder logic programs have been written by thinking about the process and then beginning to write the program. This always leads to programs.
Ladder Concept.
PROGRAMMABLE LOGIC CONTROLLER
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
Programmable Logic Controller
Actuators and Control, Part 4 Grant Agreement No LLP UK-LEONARDO-LMP Project acronym: CLEM Project title: Cloud services for E-Learning.
S7-200 PLC training courses
Chapter 5.
Seminar on "PLC” (Programmable Logic Controller)
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Discrete Control Logic
Chapter 7.
LG PLC COURSE Beginner Prepared by : -Hossam Mohammed -Ramdan said
Programmable Logic Controllers
Chapter 5.
PLC: Programmable Logical Controller
Programming Timers.
Lesson 14: Introduction To Sequential Control
ET 438B Sequential Control and Data Acquisition
PROGRAMMABLE LOGIC CONTROLLERS
ACOE347 – Data Acquisition and Automation Systems
Presentation transcript:

LADDER DIAGRAM A ladder diagram is a means of graphically representing the logic required in a relay logic system. Rail Rung

PLC WIRING DIAGRAM A B External switches Stored program Input PLC Output A 01 01 02 20 11 C B 12 02 20 03 20 11 External switches Stored program

SCAN A PLC resolves the logic of a ladder diagram (program) rung by rung, from the top to the bottom. Usually, all the outputs are updated based on the status of the internal registers. Then the input states are checked and the corresponding input registers are updated. Only after the I/Os have been resolved, is the program then executed. This process is run in a endless cycle. The time it takes to finish one cycle is called the scan time. In some controllers the idle state is eliminated. In this case, the scan time varies depends on the program length.

PLC Scan begin Input Output Resolve logic Idle Scan cycle

PLC Ladder Diagram INSTRUCTIONS 1) Relay, 2) Timer and counter, 3) Program control, 4) Arithmetic, 5) Data manipulation, 6) Data transfer, and 7) Others, such as sequencers.

LOGIC STATES ON : TRUE, contact closure, energize, etc. OFF: FALSE, contact open , de-energize, etc. Do not confuse the internal relay and program with the external switch and relay. Internal symbols are used for programming. External devices provide actual interface. (In the notes we use the symbol "~" to represent negation. AND and OR are logic operators. )

Power flows through these contacts when they are closed. The PROGRAMMING Normally Open (NO) Normally Closed (NC) Power flows through these contacts when they are closed. The normally open (NO) is true when the input or output status bit controlling the contact is 1. The normally closed (NC) is true when the input or output status bit controlling the contact is 0. 7

Coils represent relays that are energized when power flows to them. When a coil is energized it causes a corresponding output to turn on by changing the state of the status bit controlling the output to 1. That same output status bit maybe used to control normally open or normally closed contact anywhere in the program. 8

Boxes represent various instructions or functions that are Executed when power flows to the box. Some of these Functions are timers, counters and math operations. 9

Each rung or network on a ladder program represents AND OPERATION B C A Rung Each rung or network on a ladder program represents a logic operation. In the rung above, both inputs A and B must be true (1) in order for the output C to be true (1). 10

In the rung above, it can be seen that either input A or B OR OPERATION C A Rung B In the rung above, it can be seen that either input A or B is be true (1), or both are true, then the output C is true (1). 11

NOT OPERATION C A Rung In the rung above, it can be seen that if input A is be true (1), then the output C is true (0) or when A is (0), output C is 1.

AND and OR LOGIC AND OR PB1 PB2 R1 R1 = PB1.AND.PB2 PB3 PB4 R2 R1 = PB1 .OR. PB2 OR PB2

COMBINED AND & OR R1 = PB1 .OR. (PB2 .AND. PB3) PB1 R1 PB3 PB2

PROGRAMMING EXAMPLE 1

Operation id description state explanation MSI microswitch 1 part arrive R1 output to bar code reader 1 scan the part C1 input from bar code reader 1 right part R2 output robot 1 loading cycle R3 output robot 1 unloading cycle C2 input from robot 1 robot busy R4 output to stopper 1 stopper up C3 input from machine 1 machine busy C4 input from machine 1 task complete

PLC WIRING DIAGRAM

Operation Rung 1. If part arrives and no part is stopped, trigger the bar code reader. Rung 2. If it is a right part, activate the stopper. Rung 3. If the stopper is up, the machine is not busy and the robot is not busy, load the part onto the machine. Rung 4. If the task is completed and the robot is not busy, unload the machine.

PLC Ladder

Sequential Function Chart Action Qualifiers: N non-stored, executes while the step is active R resets a store action S sets an action active L time limited action, terminates after a given period D time delayed action. P a pulse action, executes once in a step SD stored and time delayed DS time delayed and stored SL stored and time limited

Sequential Function Chart

A Detailed Design Process 1. Understand the process 2. Hardware/software selection 3. Develop ladder logic 4. Determine scan times and memory requirements

Specifications OUTPUT-PORT POWER RATINGS Each output port should be capable of supplying sufficient voltage and current to drive the output peripheral connected to it.

SCAN TIME This is the speed at which the controller executes the relay-ladder logic program. This variable is usually specified as the scan time per 1000 logic nodes and typically ranges from 1 to 200 milliseconds.

MEMORY CAPACITY The amount of memory required for a particular application is related to the length of the program and the complexity of the control system. Simple applications having just a few relays do not require significant amount of memory. Program length tend to expand after the system have been used for a while. It is advantageous to a acquire a controller that has more memory than is presently needed.

PLC Status Indicators Power On Run Mode Programming Mode Fault

Troubleshooting 1. Look at the process 2. PLC status lights HALT - something has stopped the CPU RUN - the PLC thinks it is OK (and probably is) ERROR - a physical problem has occurred with the PLC 3. Indicator lights on I/O cards and sensors 4. Consult the manuals, or use software if available. 5. Use programming terminal / laptop.

List of items required when working with PLCs: 1. Programming Terminal - laptop or desktop PC. 2. PLC Software. PLC manufacturers have their own specific software and license key. 3. Communication cable for connection from Laptop to PLC. 4. Backup copy of the ladder program (on diskette, CDROM, hard disk, flash memory). If none, upload it from the PLC. 5. Documentation- (PLC manual, Software manual, drawings, ladder program printout, and Seq. of Operations manual.)

Examples of PLC Programming Software: 1. Allen-Bradley – Rockwell Software RSLogix500 2. Modicon - Modsoft 3. Omron - Syswin 4. GE-Fanuc Series 6 – LogicMaster6 5. Square D- PowerLogic 6. Texas Instruments – Simatic 7. Telemecanique – Modicon TSX Micro 8. Mitshibishi – MelSoft (GX Developer)

PLC Outputs & Power Supply Communication Ports (RS-485) Inputs

PLC Internal Architecture

PLC Input/Output

PLC Input Devices Push buttons Switches (limit switches, level switches, etc.) Sensors ...

PLC Output Devices Relay contacts Solenoid valves Signal devices (such as lamps, alarms, etc.) Motors ...

Programming terminal

Programming terminal Programming is done through programming terminal Programming terminal translates engineering language (logic control) to machine language (binary code)

Programming through standard computer Most PLC manufacturers offer software packages that allow a standard computer to be used as a programming terminal

Programming through standard computer

Relating the program to inputs and outputs

SWITCHES DPST SPDT N o n - l o c k i n g L o c k i n g N o r m a l l y 1 P 2 M u l t i p l e T h r o w M u l t i p l e P o l e B r e a k - b e f o r e - m a k e M a k e - b e f o r e - b r e a k

TERMS Throw - number of states Pole - number of connecting moving parts (number of individual circuits). SPDT A serial switch box (A-B box) has two 25 pin serial ports to switch from. A B Output Input DPST Knob How is this switch classified?

TYPES OF SWITCHES Selector switches Pushbutton switches Photoelectric switches Limit Switches Proximity switches Level switches Thumbwheel switches Slide switches RATING: 24 Volts AC/DC 48 Volts AC/DC 120 Volts AC/DC 230 Volts AC/DC TTL level (Transistor-to-transistor ±5V) Isolated Input

RELAYS A switch whose operation is activated by an electromagnet is called a "relay" contact coil input Relay coil R1 Output contact R1

RELAY Ladder Logic Example 1: For a process control, it is desired to have the process start (by turning on a motor) five seconds after a part touched a limit switch. The process is terminated automatically when the finished part touches a second limit switch. An emergency switch will stop the process any time when it is pushed.

Example 2: One motor with two pushbuttons: start and stop State variables: PB1(for start), PB2(for stop), M (for motor)

Logic PB1 is on -> CR1 energized, normally open contact 1 is closed -> M=1 PB2 is on -> CR2 energized, normally close contact 2 is open -> M=0 Rung 1: CR1=(PB1+CR1) CR2 Rung 2: CR2=(PB2) Rung 3: M=CR1 CR2

Cylinder Pneumatic Also called Actuator

ElectroPneumatic Valve Directional Control Valve which acts as a ‘switch’ to direct compressed air to each side of pneumatic actuator.

5-Port 2 Way Valve Also called Double Acting Pneumatic Actuator and 5/2 way solenoid operated directional control valve. Two ports to allow air in, one for outstroke (extend) and one for in-stroke (retract). 

Cylinder & Valve Assembly

TIMER

TIMER A timer consists of an internal clock, a count value register, and an accumulator. It is used for or some timing purpose. Time 5 seconds.

ON-DELAY TIMER (TON) For this example the timer has been set for 5 seconds. When S1 is closed, TR1 begins timing. When 5 seconds have elapsed, TR1 will close its associated normally open TR1 contacts, illuminating pilot light PL1. When S1 is open, de-energizing TR1, the TR1 contacts open, immediately extinguishing PL1. This type of timer is referred to as ON delay..

TON Example When the switch is closed input 4 becomes a logic 1, which is loaded into timer T37. T37 has a time base of 100 ms (.100 seconds). The preset time (PT) value has been set to 150. This is equivalent to 15 seconds (.100 x 150 ). The light will turn on 15 seconds after the input switch is closed.

Retentive On-Delay (TONR) The Retentive On-Delay timer (TONR) functions in a similar manner to the On-Delay timer (TON). There is one difference. The Retentive On-Delay timer times as long as the enabling input is on, but does not reset when the input goes off. The timer must be reset with a RESET (R) instruction.

TONR Example

TONR Example Cont. The same example used with the On-Delay timer will be used with the Retentive On-Delay timer. When the switch is closed at input I0.3, timer T5 (Retentive timer) begins timing. If, for example, after 10 seconds input I0.3 is opened the timer stops. When input I0.3 is closed the timer will begin timing at 10 seconds. A RESET (R) instruction can be added. Here a pushbutton is connected to input I0.2. If after 10 seconds input I0.3 were opened, T5 can be reset by momentarily closing input I0.2. T5 will be reset to 0 and begin timing from 0 when input I0.3 is closed again.

OFF-DELAY (TOFF) The Off-Delay timer is used to delay an output off for a fixed period of time after the input turns off. When the enabling bit turns on the timer bit turns on immediately and the value is set to 0. When the input turns off, the timer counts until the preset time has elapsed before the timer bit turns off.

TIMER MAX VALUES

TIMER EXAMPLE Start PB Pressed >> Pump1 ON (5 sec) >> Pump2 ON (3 sec) >> Mixer ON (60 sec) >> Drain Valve ON >> Pump 3 (8 sec)

Counter

COUNTER Digital counters output in the form of a relay contact when a pre-assigned count value is reached. 5

CTU, CTD, and CTUD

UP COUNTER (CTU)

Down Counter (CTD)

UP/DOWN COUNTER (CTUD)

COUNTER EXAMPLE

Example

Example (cont.)