Diode Dosimeters Semiconductor diodes are inexpensive, yield high output, and do not require bias, making possible simple detector arrays to measure transverse.

Slides:



Advertisements
Similar presentations
Introduction to RF for Accelerators
Advertisements

Chapter 4 Radiation Dosimeters
Introduction to Semiconductor Devices
Instrumentation and Measurements Dr. Mohammad Kilani
An Electronic System Power Supply Example
Chapter 7 Operational-Amplifier and its Applications
Geiger-Muller detector and Ionization chamber
Page 1 © J.Paul Robinson - Purdue University Cytometry Laboratories BMS 631 – LECTURE 8 Flow Cytometry: Theory J.Paul Robinson Professor of Immunopharmacology.
Chapter 17 Current and Resistance. Chapter 17 Objectives Describe electric current Relate current, charge, and time Drift speed Resistance and resistivity.
Development of an Active Pixel Sensor Vertex Detector H. Matis, F. Bieser, G. Rai, F. Retiere, S. Wurzel, H. Wieman, E. Yamamato, LBNL S. Kleinfelder,
1 A proposal of new simple system for testing a large number of MPPC for the R&D phase of GLD calorimeter 2007/Feb/6 ACFA ILC Workshop ICEPP, University.
Measurement of Absorbed Dose (6)
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
The Calibration Process
Astable multivibrators I
Electric Curcuits and Measurements Basic Electrical components and their functions Measurements of electrical circuits characteristics - Multimeter - Oscilloscope.
Classification of Instruments :
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Current Integrators In proton radiotherapy, dosimeters are used in two distinct ways: as beam monitors, to end the treatment at the prescribed dose, and.
BIOLOGICAL EFFICIENCY OF A THERAPEUTIC PROTON BEAM: A STUDY OF HUMAN MELANOMA CELL LINE I. Petrović 1, A. Ristić-Fira 1, D. Todorović 1, L. Korićanac 1,
Ion Collectors and Detectors
DOSIMETRY COMMISSIONING OF THE LNS-INFN PROTON THERAPY FACILITY THE DOSIMETRIC CHARACTERISTICS OF NARROW PROTON BEAMS USED IN EYE THERAPY HAVE BEEN DEFINED.
Characteristics of Op-Amp &
Integrator Op Amp Amplifier
Calibration & Curve Fitting
CHAPTER 6 VOLTAGE REGULATOR POWER SUPPLIES (VOLTAGE REGULATORS) Fig. 6.1 Block diagram showing parts of a power supply. Power supply Power supply: a.
Dosimetric evaluation of a new design MOSFET detector Per H. Halvorsen* & Stephanie Parker University of North Carolina.
Electronic Troubleshooting
Semiconductor Devices III Physics 355. Transistors in CPUs Moore’s Law (1965): the number of components in an integrated circuit will double every year;
Field-Effect Transistor
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
1 Chapter 3 Methods of Analysis Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
CHAPTER 11 Op-Amp Applications. Objectives Describe and Analyze: Audio mixers Integrators Differentiators Peak detectors Comparators Other applications.

Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Control System Instrumentation
1 SEMICONDUCTORS Diode ratings and construction. 2 SEMICONDUCTORS Diodes have two active electrodes between which the signal of interest can flow The.
Use of the IC Profiler detector array for comprehensive machine QA ESTRO QA & Dosimetry Satellite Symposium Steve Morgan, Medical Physics Dept,
Xoft Routine Per Article Manufacturing Testing of the Axxent ® Source S. Axelrod, T.W. Rusch, M. Powell; Xoft, Inc., Fremont, CA  Purpose: To select sources.
CS TC 22 CT Basics CT Principle Preprocessing. 2 CT Basics CT principle preprocessing CS TC 22 Blockdiagram image processor.
Module 1: Measurements & Error Analysis Measurement usually takes one of the following forms especially in industries: Physical dimension of an object.
Chapter 26 Lecture 22: Current: II
Teachers Name - Suman Sarker Subject Name Subject Name – Industrial Electronics (6832) Department Department – Computer (3rd) IDEAL INSTITUTE OF SCIENCE.
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Bragg Peak The Bragg peak, as we use the term, is the on-axis depth-dose distribution, in water, of a broad quasi-monoenergetic proton beam. A carefully.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
If information seems to be missing, make any reasonable assumptions. 1.A target has an areal density of 2.3 g/cm 2 and a thickness of 0.8 inch. What is.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
1 A protocol for the determination of absorbed dose from high energy photon and electron beams AAPM TG-21 Protocol (Med Phys 10: , 1983) 和信治癌中心醫院.
CHAPTER 5 DC AND AC BRIDGES.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
CONFIDENTIAL MATERIAL Michele Togno - II Annual ARDENT Meeting, Milan – October, 14 th D Ionization Chambers Array for Clinical Applications.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
FUNCTION GENERATOR.
MECH 373 Instrumentation and Measurement
HEC I chip design Short summary (J.Bán).
Introduction to Semiconductor Devices
MOS Field-Effect Transistors (MOSFETs)
Dr: Mohamed Afifi By Lecturer Radiological Science
Control System Instrumentation
NanoBPM Status and Multibunch Mark Slater, Cambridge University
BESIII EMC electronics
Xoft Manufacturing Procedures
Presentation transcript:

Diode Dosimeters Semiconductor diodes are inexpensive, yield high output, and do not require bias, making possible simple detector arrays to measure transverse dose distributions. Some diodes are extremely small and therefore well suited to measuring high dose gradients, as in eye treatment or neurosurgery fields. A.M. Koehler (‘Dosimetry of proton beams using small silicon diodes,’ Rad. Res. Suppl. 7 (1967) 53) carefully measured diode characteristics looking towards that application, and diodes are still the gold standard for eye beam calibrations at the Burr Center despite several attempts to come up with something better. However, diodes suffer radiation damage so they need occasional recalibration. They have a significant temperature coefficient, and over-respond to low energy protons by comparison with PPIC’s. Also, they require a current integrator that keeps the voltage across the diode as near zero as possible. The effective resistance of a well used diode at zero applied volts can be as low as 10 MΩ, so a voltage burden of even 1 μV causes 0.1 pA of ‘drift’. Therefore integrators to be used with diodes must hold a voltage burden in the μV range. For ion chambers and Faraday cups that is not a concern. Energy response and radiation damage depend greatly on the fabrication technology. Scanditronix sells diodes whose response is the same as that of a PPIC. Google G. Rikner or E. Grusell to bring up articles on these diodes, which are fairly expensive.

The diode is a linear dosimeter if and only if the output current flows into a short circuit. Either a classical or recycling integrator will accomplish that. However, as explained earlier, the voltage at the input must be adjusted to zero within a few μV. That only lasts if the opamp’s offset voltage tempco and long-term drift are correspondingly small. The Texas Instruments TLC27L2 has appropriate specs. Dose Response vs. Rate

The diode Koehler tested over-responds (relative to a PPIC) by ≈ 8.5% in the Bragg peak. Nonetheless this diode was and still is used to measure the depth-dose in the very successful eye treatment program. Other diodes behave differently! (left) Radiation damage kicks in at about 10 Krad. Sometimes it pays to pre-irradiate diodes when they are to be used as dosimeters. (right) The diode Koehler tested had a large tempco, -2.2%/°C. Radiation Damage, Tempco, and Energy Response

The 32 × 32 ‘CROSS’ diode array built for QA in the HCL radiosurgery beam and now used for general purposes at the Burr Center. 1N4004 diodes are mounted on perfboard at 0.2″ pitch. Leads not at ground are covered with insulating paint to discourage ions. The diodes put out so much signal (130 pC/rad) that they will not reach the 10 Krad damage threshold in the lifetime of the device, so they are not pre-irradiated. A 2D Diode Array

Real-time displays on the PC running the CROSS array. The measurement shown took 2 seconds. Array devices usually take much longer to set up than to use, so ease of setup and robustness should guide the mechanical design. Data log files should be generated and named automatically e.g. 29FEB08.DAT, without operator choice or intervention. Diodes are recalibrated annually by exposing CROSS to a Gaussian dose distribution at several preset positions. The 64 diode constants and a few parameters for the unknown dose distribution are thus overdetermined, and found by a least-squares fit.... and its Output

History of weekly diode calibrations at HCL showing radiation damage over 5 years, greatest for the diode (RET3) used daily in the eye treatment line. Radiation Damage Over a Span of Years

The DFLR1600 is a surface- mount 1A 600V rectifier costing $0.10 in 1000’s. With a suitable preamp and a 10 μCi source one can see pulses at a few per second on the bench. The internal geometry is plane-parallel, perfect for dosimetry.

Single pulse recorded with an IOtech 6220 data logger (16 bits, 100K samples/sec, 10 μs/sample). The 6220 ($3000 including software) can sample up to 12 channels simultaneously at that rate. Data are stored in files for off-line analysis.

A dosimeter in a passive range modulated beam puts out a signal whose duration depends on its depth in the beam. The abrupt steps are smeared by the finite distal falloff of the Bragg peak and because the beam usually passes through several mod steps. The figure shows data from a small IC with the amplifier time constant deconvolved (H- M Lu, Phys. Med. Biol. 53 (2008) 1413 – 1424)

With a small diode driving a moderately fast amplifier the signal at one depth looks like this. Top: ten modulator cycles. Middle: fourth cycle. Bottom: start of fourth cycle. We see pulses from one or a few protons even at radiotherapy dose rates because the diode is so small.

As a reality check we can sample the waveform, integrate (sum) over each burst, average over ten bursts and apply the known amplifier V/nA to find the charge 10. Doing this at many depths we obtain the diode’s version of the SOBP. The line represents data from a Markus (small plane-parallel IC) chamber (arbitrary normalization).

How best to characterize the width of the burst, which should correlate with depth? A simple and efficient measure is the rms value 10 computed by the procedure shown to the right. This works as well for stochastic distributions as for smooth ones. Straightforward arithmetic: no smoothing or curve fitting! Diode depth in a water tank as a function of 10 is well fit by a cubic (four term) polynomial, which can serve as a calibration function. The rms deviation of measured points from the fit is 0.29 mm! This precision was confirmed with test data not used in the fit.

These measurements, using a single diode in a water tank, have been written up and accepted for publication. The diode was a PTW dosimetry diode, but we have now done similar measurements with an array of DFLR1600’s. The calibration and depth resolution are similar: Gottschalk et al., ‘Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry,’ Med. Phys. 38 (2011) Bottom line: if you calibrate a diode in a passively scattered, range modulated calibration beam and subsequently place the diode at an unknown depth in the water tank, a simple measurement using ≈0.2% of a typical single fraction dose will tell you the WEPL (water equivalent path length) to that point to ≈0.3mm (1σ). We are now doing measurements with an array of diodes and an anthropomorphic prostate phantom. The goal, using diodes mounted on a rectal balloon, is to measure WEPL to the rectal wall with a test beam on treatment day. If we compare that with WEPL from the treatment planning program, we can adjust the energy of the treatment beam. Small diodes are unique in that, properly used, they can measure fluence rate (by counting pulses) and dose rate (by integrating the area) simultaneously. Both need to be calibrated (equivalent to measuring effective area and effective mass).

Diodes are inexpensive, rugged and easy to use as they require no bias. Though small ion chambers are preferred nowadays for clinical dosimetry, diodes still have their place. When used in arrays to measure transverse dose, over-response at low energies does not matter if the distribution of energies is independent of transverse position. Diode arrays are simple, inexpensive and rugged, but depend on the availability of a suitable current integrator array. The current integrator input must present a low impedance and a small, stable voltage burden ≈1μV. If diodes are used for precise dosimetry their temperature coefficient must be measured and taken into account. They must also be recalibrated occasionally because of radiation damage. In a passive range modulated beam the time dependence of diode response contains precise information about the water equivalent path length (WEPL) to the diode. With the availability of fast multi-channel data loggers, this opens up the possibility of using end-of-range to discriminate between the target volume and the volume to be spared, if a diode or diode array can be placed in a body cavity (œsophagus, oral, or rectal) distal to the target volume. Summary