Spark Detection and Extinguishing System. Spark Detection – markets Initiative from Finnish insurance companies  Need for technically competitive and.

Slides:



Advertisements
Similar presentations
ASF Leak Detectors – New Design Präsentation neuer LAG Newsletter.ppt 1 After our previous device models are used for nearly four decades in more than.
Advertisements

General Safety Overview and Information
Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
Water & Wastewater Pump Station Control Basic parts: Metering & current limiters Main switch chassis Telemetry & Control Pump controls Questions: -IP.
Customer Service – International dept. STAR 24 3 E.
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
Total HVAC Control from anywhere Easy control that can save a fortune
Introduction Enthalpy Wheel
AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING Prepared by: Wajdi abu-muhsen Khaled aamer Ahmad Al-Hunate Nabeel.
Analysis of Spark Ignition Engine Management System
Chapter 12 Systems and Equipment for Fire Protection.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
CHAPTER 3 INTERNAL COMBUSTION ENGINES
Engineer Presentation
Hydraulics.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Electrical Safety This material was produced under a grant (SH22249SH1) from the Occupational Safety and Health Administration, U.S. Department of Labor.
Mechanical for Oil Heat
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Muhajir Ab. Rahim School of Mechatronic Engineering
Lease Automatic Custody Transfer
Fire Detection Presentation
Chapter 22 Current Electricity.
Components of Centrifugal pumps
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
High Sensitivity Smoke Detection
Why………….? coz Speed thrills but Kills! Why Should Speed Governor / Limiter be Installed.
System Overview Model 1280 Edge Marking Technology - Multicolor Bruce T. Dobbie.
Hydraulic Kit (pump and tank) Pictures from prototype.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
I.C. ENGINES LECTURE NO: 08 (24 Mar, 2014). Combustion Formulas Combustion is a chemical reaction in which certain elements of the fuel combined with.
1 Internal | ST/PRM2-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
The Theory of Near Light Scatter
ELECTRICITY COST OF CHILLER AND COOLING TOWER PUMPS KILLING YOU? We Have The RIGHT Solution just for YOU! + =
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
Detector Derailment Device (&) Frenado (Braking) Automatic Train
Current Electricity is the rate at which charges pass a given point. The higher the current is the greater the number of charges pass the point each second.
ARM and GPS Based Transformer monitoring system with area Identification Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
The C.I. Engines Fuel System  The C.I. engine demands that the fuel supplied is –  Timed to inject when the piston is near the end of the compression.
Fire Fighting Robotic Vehicle. Introduction:  It is designed to develop a fire fighting robot using RF technology for remote.
Introduction of Laser Evaluating Technology to Street Leak Surveys Ashraf Salha APA Group Gas Speak Colloquium September 2015.
Are you having trouble receiving strong signal strength in your home or office? Well, A WiFi booster or WiFi repeater is the right solution for you. Below.
ENGINEERING PLUMBING AND SANITATION Applies Fire Company of Plumbing System.
Start presentation Bio-fuel pellet utilization in heat production, Finnish experience, examples and practices Finnish Energy Day Ukraine, Kiev Managing.
Fire Detection Equipment and Systems in Dubai
BAG FILTER.
Unit 13 Oil-Burning Equipment
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
Black Carbon Burner An-Najah National University
Actuators Topics covered in this presentation:
General Safety Practices
Electronic Fuel Injection
INDUSTRIAL HYDRAULICS
How SCADA Systems Work?.
HOUGHTO-MIX Coolant Mixing and Supply Unit Rainer Hoerbst
Electrical Gas Plumbing Heating & Cooling
KINEMATICS 1. A nozzle is so shaped that the velocity of flow along the centre line changes linearly from 1.5 m/s to 15 m/s in a distance of m. Determine.
BASIC MECHANICAL ENGINEERING
Design and Development of Abrasive Jet Machine And
Risk Management Student Powerpoint
Presentation transcript:

Spark Detection and Extinguishing System

Spark Detection – markets Initiative from Finnish insurance companies  Need for technically competitive and cost efficient Spark Detection System ATEX (94/9/EY, 1992/92/EY) directives  Regarding potentially explosive atmospheres and machines and devices used in them.  State council statute obligates employers to evaluate possible risks regarding dust explosions and in case of risk move to corrective actions

Spark Detection – Dust explosion Dust explosion is a fast burning reaction. Dust explosion moves forward from the ignition point spherically lifting pressure and thus causing damage to constructions Dust explosion is possible, when there is enough fine material mixed with air and a spark or high enough temperature Material can be almost anything as long as it is fine enough.

Spark Detection – What it does The purpose of the system is to extinguish the detected sparks before they cause a dust fire or a dust explosion. Following systems can be protected with the system:  Saw dust outlet systems  Dust outlet systems  Grinders and pellet burners Spark detection and extinguishing system is not used for protecting rooms

Spark Detection – markets Applications in mechanical wood processing industry and more accurately:  sawdust outlet pipes, conveyors etc Potential customers:  carpenters, sawmills, planing mills, furniture factories, schools, paper mills…

Spark Detection – Principle Extinguishing unit Spark detectors Saw dust outlet pipe Air flow 1. Spark detectors and extinguishing unit  Basic system includes only two detectors and an extinguishing unit  Extinguishing unit is a part of the Spark detection system

Spark Detection – Principle Extinguishing unit Spark detectors Saw dust outlet pipe Air flow Panel 2. Detectors, extinguishing unit and panel  By adding a panel to the system, it is possible to –get info of the possible alarms (siren and beacon) –shut down machines in the production process –test the system

Spark Detection – Principle Extinguishing unit Spark detectors Saw dust outlet pipe Air flow Panel FX 3NET 3. Detectors, extinguishing unit, panel and FX 3NET  Spark detection system panel can be connected to a control computer via ModBus-fieldbus. This enables for example the monitoring of alarm log

Spark Detection – connection to fire alarm panel The system is usually used as an individual system The system can be connected to a fire alarm panel, if:  the alarm needs to be transmitted to the fire brigade  the alarm information needs to be tranferred to the fire alarm panel locally

Spark Detection - System The system consists of three different main blocks: Detection  Detectors  Test lamp Control  Control Panel  Alarm devices (sounder and beacon)  Signal router Extinguishing  Extinguishing unit  Pressure boost unit

Spark Detection – System Components The System consists of three main blocks  Spark detector - Detects the sparks and controls the extinguishing unit - Transmits the info about the extinguishing events to the panel - Measure area UV - IR  Fulfils the requirements of: EN50081, EN50082, EN , EN54- 1, IEC /2

Spark Detection – System Components  Spark detection panel - Works as a human interface - Shuts down machines in alarm state - Measures device temperatures - Communicates with control computer via ModBus (option) - System can be connected to Esmi FX Fire panel Integration

Spark Detection – System Components  Extinguishing unit –Extinguishes sparks with a fine water screen. Extinguishing unit is fault monitored by a flow switch and also by the panel. –Extinguishing unit is used in saw dust outlets under 450mm diameter –The self cleaning unit is designed so that the particles flying in the pipe will not damage it Extinguishing unit

Spark Detection – System Components  Extinguishing unit –Extinguishes sparks with a fine water screen. Extinguishing unit is fault monitored by a flow switch and also by the panel. –Extinguishing unit is used in saw dust outlets over 450mm diameter –The self cleaning unit is designed so that the particles flying in the pipe will not damage it Extinguishing unit

Spark Detection – System Components  Pressure booster (part of the extinguishing unit) –Requirements for the water and electric suplies: Water pipe min. DN28 and flow 100l/min/nozzle Motor voltage 3*400V and current 5A Pressure booster consists of a water pump and diaphragm pressure tank

Spark Detection – Installation requirements Pressure booster  Electrical connections has to be done by an electrician  Pipework has to be done by a plumber Planning or installing of Spark detection systems in Finland does not require same kind of qualifications as in case of sprinkler systems. Spark detection systems are not EN standardised. Planning and installations should done according to European Insurance Committee: CEA Specifications for spark detection, spark extinguishing and spark diversion systems – Planning and Installation

Spark Detection – System Components

120 Spark detectors and AN6400 Panel

Spark Detection – System Components Extinguishing unit

Spark Detection – System Components Pressure booster

Spark Detection – System Components Alarm devices, siren and beacon

Spark Detection – System Components Temperature monitoring

Spark Detection – System Components Expansion options

Spark Detection – System planning System response time from detection to extinguishing is <100ms Extinguisher units are installed in direction of air flow after the detectors Detector Extinguishing unit

Spark Detection – System planning The distance between extinguishing unit and detector is calculated with the following formula d= F x 2D, where d = min. installation distance F = air flow speed (typ m/s) D = System delay (<100ms) Calculated with 25 m/s air flow d = 5m Manufacturers ”thumb rule” d = 7m d

Spark Detection – System planning The bigger the diameter of the pipe is, the more water has to be injected into it. The needed water amount can be calculated with the following formula: Q = F x A x B, where Q = water amount needed l/s F = air flow speed (typ m/s) A = pipe cross area π x r² B = constant 0,2l/m³ (0.2 litres water / 1m³ air)

Spark Detection – extinguishing unit / nozzle Nozzle in the pipe on the left In this picture there is a nozzle designed for 400 mm pipe in a 700 mm pipe

Spark Detection – Installation pictures Detectors and a test lamp Detectors are installed facing each other on the sides of the saw dust outlet pipe. This way maximum visibility of the detectors is achieved. Detectors must not be installed in the bottom of the pipe. Danger of coverage. Detectors must not be installed just after a corner. Danger of breakage. Signal router

Spark Detection – Installation pictures Detectors and Signal router Detectors Panel Pressure Booster Signal router Extinguishing unit Sounder and Beacon

Smallest detector in the market  Very fast response time (1ms) Fastest System response time on the market Detector and extinguisher can be installed near to each other thanks to fast System response time  - > less extinguishers outdoors -> less separate extinguisher warmers  Minimized extinguishing water -> less problems with filters User friendly, easy user interface Cost effective compared to earlier systems on the market Spark Detection – Advantages