LoneStar Fire Specialties

Slides:



Advertisements
Similar presentations
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Advertisements

Fire Apparatus Pump Theory
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
High-Pressure Air Bags 101
CAFS On-Line Orientation
Introduction to Truck 3 Pierce 105’ Aerial
Hydraulic Calculations
Augmenting Fire Standpipe Systems
Driver Recert 2013 Topics Review of Water Supply SOG’s MAWW Main St. Tank OOS BlitzFire Deployment with Water Thief Tower Operations Foam System Review.
HYDRAULICS LET’S DO SOME MATH!.
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Pumping Apparatus Driver/Operator
Fire Pump Theory TCFP Section Part 3 Operations.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Streams SFFMA Training Objectives: –
Fire Apparatus Familiarization
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Purpose of Standpipe and Hose Systems
Presentation on City of Westminster Water System Pressures May 1, 2013.
Pumper Operations n Why do we need to be concerned about being good pump operators? n When we are good pump operators the personnel working the hand lines.
Pumping Apparatus Driver/Operator
Chapter 9 Water Supply.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Chapter 9 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Task Force-7 Engine 14 Engine 13 Batt. 2
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
Basic Hydraulics Irrigation.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
Water Supply 1. Water Supply Components
Intermediate SFFMA Objectives: – Hrs received.
Engine Types and Uses.
Module C Sprinkler systems (4-20)
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
Instructor Lee Lautzenheiser
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
Pumping Apparatus Driver/Operator
Water Supply Firefighter II.
FVCC Fire Rescue Water Supply.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
TANKER OPERATIONS Long Laneway – 1 st arriving pumper P-1 FIRE BLDG House?= 38mm x2 + 65mm backup line Barn? = consider 2- 65mm right away Lay a Hi-Vol.
SteamBoat Fire Rescue DOP September 20-22, SteamBoat Fire Rescue Pumping Course September 20 – 22, 2010 Introductions Syllabus Course Objectives.
Firefighter III Module B Water Supply (4-19) (4-19)
Fire Fighting Systems Fi Fi Mains ●White System: This system has a lower output as far as volume goes. This main supplies 3x Eductor/Hydrants (500 gpm).
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Water System Master Plan & Rate Study City of DeKalb, Illinois City Council Presentation May 16, 2015.
Video: Fire Hydrant Time: 1:01 Chap 14-1
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
 All fire pumps are rated by drafting through 20 ft. of hose with 10 ft. of Lift  Theoretical Lift = 14.7 psi x 2.3 ft/psi = 33.8 ft.  Maximum practical.
Water Shuttle Operations
Snohomish County Training Officers 2013Q3. Drafting Need for drafting operations Set up and resource considerations Shuttle operations Jet Siphon Operations.
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
2010 Union County Water Movement Training Review Leesburg Twp. September 18, 2010.
Operating Fire Pumps Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Water Supply (Fire Fighter I)
2013Q1.
WATER SUPPLY FOR NON-HYDRANT AREAS
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

LoneStar Fire Specialties Water Supply

Water Supply Most common types of water supplies Booster tank water Hydrant (Pressurized source) Drafting (Static source)

Water Supply Booster Tank Water Static water source Limited amount yet always available Common tank sizes Engines 500 – 1500 Gallons Tanker / Pumpers 1500 – 3000 Gallons Quints or other aerial apparatus typically limited to 500 Gallons or less

Water Supply Booster Tank Water Key Point: Apparatus are not designed to flow their pumps at full capacity with water from the booster tank! Why you ask?

Water Supply Booster Tank Water NFPA 1911 sets minimal performance standards for flows from tank to pump. They are…a booster tank that is 500 gallons or larger must be able to flow 500+ GPM. A booster tank less than 500 gallons must flow only 250 GPM from tank to pump. In most cases the plumbing between the tank and the pump is 4” which is capable of flowing around 500 – 600 GPM.

Water Supply

Water Supply Fire Hydrants Two main types: Dry barrel & Wet barrel

Which type of hydrant is this?

Water Supply DRY BARREL Characteristics: Water is held below anticipated frost line. Barrel drains through an opening at bottom of the hydrant. Key Point: Remember to completely open and completely close main valve to prevent water loss

Water Supply Wet Barrel Hydrants Common only where freezing is not a possibility. Typically have a compression-type valve for each outlet. Entire hydrant is always full of water.

Know if a hydrant is out of service! Water Supply Hydrant Color Codes Know your territory Know the emergency contact numbers to your water distribution facility! Know if a hydrant is out of service! Hydrant Class Color Flow AA Light Blue 1,500 gpm or more A Green 1,000 – 1,499 gpm B Orange 500 – 999 gpm C Red Less than 500 gpm

Water Supply Many fire departments have already calculated the pump discharge pressures for pre-connected hose lines. This is not possible for fire hydrants because: They are dynamic No two hydrants are the same

Water Supply Of all of the hydraulic calculations that an engineer is required to know, the most important calculation is to determine how much water you have available to from a fire hydrant. Although there are three calculations available, we believe the percentage method is the easiest to use.

How to figure the available water from a hydrant Water Supply How to figure the available water from a hydrant Percentage Method Percentage drop = (Static – Residual)(100) / Static Example – One line flowing 200 gpm Static pressure 70 psi Residual pressure 63 Percentage drop = (70-63)(100)/70 Percentage drop = (7)(100) / 70 Percentage drop = 700 / 70 Percentage drop = 10%

Water Supply 0-10% Use this chart with the percentage method. 11-15% Note the word MIGHT in the lower right box! We will come back to that later. % decrease of pumper intake pressure Additional water available 0-10% 3 times amount of water being delivered 11-15% 2 times amount of water being delivered 16-25% same amount of water being delivered Over 25% More water MIGHT be available

Good question….I’m glad you asked. Water Supply I know what you’re thinking. What if I start flowing the initial attack lines off of the booster tank? Then, how will I know what my static pressure is when I do get a pressurized water supply? Good question….I’m glad you asked.

So the big question is….How much water do I have available? Water Supply So the big question is….How much water do I have available? ANSWER: As much as there is available in the hydrant! You can NEVER flow more than you are receiving!

Water Supply It is common for engineers to say they can not flow any additional lines if their intake gauge is at 20 psi. In many cases this may not be true. You may be challenged with a similar problem during the hands-on portion. So, be thinking about how you will recognize an attempt to flow more water than you are receiving.

Water Supply Drafting Excellent way to obtain a source of water in the rural setting. Several different source options… i.e. Lakes, Ponds, Rivers & Swimming Pools. Access is always a problem to consider. Height of lift is a limiting factor. Consider the chart on the following page.

Water Supply Feet of Lift GPM 10 1250 12 1175 14 1100 16 1020 18 900 Rated Pump Capacity 1,250gpm Feet of Lift GPM 10 1250 12 1175 14 1100 16 1020 18 900 20 790

How can you position the hose for lift? Water Supply How can you position the hose for lift? Use a ladder to stabilize the hard suction hose and to help position the end with a minimum of 24 inches of water surrounding.

“Dear Chief” letter you are about to write. Water Supply Remember: When parking your 30,000 lb. fire truck on a boat dock, firmly connect it to a very large tow truck. Also think about the “Dear Chief” letter you are about to write. Ifsta essentials p. 390

Water Supply Fire apparatus pumps are not capable of lifting water more than 25 ft. The amount of lift will also decrease as you go up in altitude. Key Point: Atmospheric pressure decreases 0.5 psi with every 1000 ft of altitude. Thus, limiting our drafting capabilities.

Water Supply As a general rule, for every one inch of vacuum that is created in the apparatus pump, one foot of water will be lifted.

Rural Drafting Hydrant Water Supply Rural Drafting Hydrant Dry Hydrant Excellent way to utilize a natural water source in an inaccessible location. Makes for faster setup time. Government grant funding available for installation.

Rural Drafting Hydrant or Water Supply Hard Suction Hose Rural Drafting Hydrant or “Dry Hydrant” Static Water Source Suction Strainer Water Level

Water Supply A rural drafting hydrant, or “dry hydrant,” uses the same principle of drafting as a ‘normal’ drafting operation. The BIG advantage to this type of hydrant is that the engineer still has a source of water, but the engine can be placed well away from the edge of the water.

Water Supply Operations Water Shuttles Relay Pumping Dual Pumping & Tandem Pumping

Water Supply Water Shuttle These are sometimes referred to as tender shuttles or tanker shuttles. Water shuttles are commonly employed to supply water to fire scenes that are very remote from the water supply. Many times the distance is too great for relay pumping to be practical. Wildland fires are also a good example in which the water supply is constantly moving forward with the firefighting apparatus.

length, unless utilizing relay pumping. Water Supply Water Shuttle Recommended for distances over a ½ mile or if distance is greater than hose lay capabilities. Key Point: Your supply line hose size will determine your hose lay length, unless utilizing relay pumping. It is critical to have an adequate number of water tankers to maintain necessary fire flow. Requires an apparatus at the fill site. The largest disadvantage of a water shuttle operation is the time it takes to setup and to become efficiently operated.

Utilizes two or more pumpers to move supply water over long distances. Water Supply Relay Pumping Utilizes two or more pumpers to move supply water over long distances. The pumper at the water source pumps water under pressure to next pumper in line. This pumper takes this water and boosts the pressure in order to send it to the next pumper in line.

Water Supply Relay Pumping Place the apparatus with greatest pumping capacity nearest to the water source. Water supply must be capable of maintaining the necessary fire flow during the entire incident. Establish the relay early enough to make it worthwhile. Generally do not supply more than 50 psi to the apparatus pumping at the fire scene. When supplying LDH average 25 psi per 100 ft. NEVER EXCEED 200 psi on LDH

Water Supply Relay Pumping With the 25 psi average, what is the longest hose lay that can be made? 800 ft. Reason: 200 psi is the maximum test pressure for LDH

Water Supply Can relay pumping be utilized on a static water source? Can you use relay pumping with a pressurized water source? I know you said… YES

What is wrong with this picture? Water Supply Intake To Intake? What is wrong with this picture?

Often incorrectly referred to as Water Supply Nothing, right? Absolutely Not! This is Dual Pumping Often incorrectly referred to as Tandem Pumping.

Water Supply Dual Pumping Operation used to supply water to two pumpers by connecting intake-to-intake. The first pumper is attached to the PRESSURIZED water supply and the second receives excess water the first pumper is not using.

Water Supply Dual Pumping One very strong hydrant can supply water to two separate pumping apparatus. Ex. You are flowing 1200 gpm but are attached to hydrant capable of flowing 1800 gpm. You could dual pump by attaching the first engine’s intake to the second engine’s intake and supply them with about 600 gpm.

Can dual pumping be used in combination with relay pumping? Water Supply Dual Pumping Can dual pumping be used in combination with relay pumping? This is the wonderful thing about pump operations. Our engineering abilities and imaginations are our limitations. Granted we must have the water and apparatus available. I encourage you to look beyond the “way we have always done it ” of the past and be creative. The future of the fire service is counting on us to move forward and not be afraid to look at new ideas and welcome change.

Water Supply Tandem Pumping Used when the pressure needed is higher than the capabilities of a single pump. The pumper at the water supply discharges to the intake of the attack pumper. This pumper can now boost the pressure even more to reach the desired pressure.

-Name a couple of scenarios where tandem pumping could be beneficial. Water Supply Tandem Pumping -Often used when pressures that are needed are more than one pumping apparatus is capable of supplying. -Name a couple of scenarios where tandem pumping could be beneficial.

Water Supply Tandem Pumping High rise sprinkler or standpipe systems. When pumping water up steep grades.

Water Supply Tandem Pumping Sounds very similar to relay pumping, right. Let’s separate the two operations. Relay Pumping- Used to move supply water over long distances. Tandem Pumping- Utilized to overcome pump pressure needs by placing two pumps into series operation.

Use everything to your advantage! Water Supply Think outside the box! Use everything to your advantage! Training evolutions are a great time to experiment and try new techniques. Don’t limit yourself just because someone has told you “that’s the way we have always done it.”

Water Supply NOT LIKELY IN TEXAS!!!

Water Supply Summary BUT… We must know where we are going to receive our water supply and be confident that it will sustain our fire flow needs throughout the entire incident. BUT… If you, the engineer, experience a momentary or long term loss or partial loss of water you MUST know how to… 1st Recognize the problem. 2nd Determine how you are going to handle the situation. 3rd Make quick short term adjustments, at the pump panel, to cure the problem. 4th Determine what the long term cure for the problem is. 5th Notify the Incident Commander of the problem and tell them what you need to stabilize the issue. 6th Stabilize the problem!