Electronic Data Collection

Slides:



Advertisements
Similar presentations
Interfacing to the Analog World
Advertisements

“NEFTOGAZ TECH” LLC President of the Group of companies “ND” Leonid Pashkevych, 2014 Specialized presentation about the System of complex automation of.
Data Acquisition Risanuri Hidayat.
Prepared by: Hamzah Snouber For: Dr. I mad Breik.
Met 163: Lecture 4 Chapter 4 Thermometry.
Environmental Monitoring System at GBC and Its Components Presenter: Sanjaya Gurung.
STARLight PDR 3 Oct ‘01I.1 Miller STARLight Control Module Design Ryan Miller STARLight Electrical Engineer (734)
Applying Wireless I/O Controller To NeSSI May 7, 2001 Mike Horton President & CEO Crossbow Technology, Inc.
Overview of Temperature Measurement ME 115 Figures are from “Practical Guidelines for Temperature Measurement” unless otherwise notedwww.omega.com.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Dataloggers. Records voltage, current, or circuit closing Environmental variables must be converted to electronic signal.
NeSSI Wireless Sensor / Actuator Networking March 7, 2001 John Crawford VP, Business Development Crossbow Technology, Inc.
Met 163: Lecture 4 Chapter 4 Thermometry. Thermoelectric Sensors The junction of two dissimilar metals forms a thermocouple. When the two junctions are.
Study of Data Acquisition System and Data Loggers
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Power and Energy Measurements Chapters: 39 and 42 Juha Kallunki,
Chapter 8 Output Modules.
Sensors Introduction Describing Sensor Performance Temperature Sensors
Basics of Sensors. A sensor is a device which is used to sense the surroundings of it & gives some useful information about it. This information is used.
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
Oscilloscope Tutorial
SOLAR CELL PRESENTED BY ANJALI PATRA ANKITA TRIPATHY BRANCH-EEE.
Topic 1 different attributes that characterize sensors ETEC 6405.
A Mobile Wireless Electrocardiogram System for Health Care Facilities John Farner Jason Fritts Julian Jaeger Joe Richard Georgia Institute of Technology.
SCADA and Telemetry Presented By:.
Digital to Analog Converters (DAC) 1
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
Probe12 Sap Velocity based Sap flow logger & Irrigation Scheduler.
Transducers/Sensors Transducer/sensor converts a non- electrical quantity, measurand, into a related electrical output signal Ideally there is a linear.
COMPONENTS REQUIRED STEP DOWN PRANSFORMER:
Sensors are mostly electronic devices used to monitor or capture something.
Introduction to Engineering Lab 4 – 1 Basic Data Systems & Circuit Prototyping Agenda REVIEW OF LAB 3 RESULTS DEFINE a DATA SYSTEM  MAJOR TYPES  ELEMENTS.
ACCESS CONTROL ExpansE - Distributed Access Control.
Data Acquisition Dr inż. ZDZISŁAW PÓLKOWSKI Polkowice, 2015 University of Pitesti Dolnośląska Wyższa Szkoła Przedsiębiorczości i Techniki w Polkowicach.
Module 1: Introduction to PLC
Digitization When data acquisition hardware receives an analog signal it converts it to a voltage. An A/D (analog-to-digital) converter then digitizes.
Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
16722 Mo: data acquisition150+1 data acquisition.
Student’s Name with USN No.
Introduction to Sensors and Calibration Factors. Choosing a suitable recording range on a data logger Logger will have several range options: e.g. -10.
Transducers.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
Temperature and Pressure Sensors Seth Price Department of Chemical Engineering New Mexico Tech Rev. 10/27/14.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
Consider following problem Want to measure temperature range of: -15 o C < T 1 < 35 o C. Reference junction, T 2, = 0 o C. Output must be in range of -5Volts.
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
Analog-Digital Conversion. Analog outputs from sensors and analog front- ends (analog signal conditioning) have to be converted into digital signals.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Data logging: The term 'data logging' refers to collecting or gathering data over a period of time. How Data is collected? Sensors are used to take readings.
MECH 373 Instrumentation and Measurements
Temperature Sensors.
Temperature Sensors.
Author: Nurul Azyyati Sabri
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Data Acquisition Systems
INSTRUMENTASI INDUSTRI
Instrumentation & Measurement (ME342)
Overview of Temperature Measurement ME 115
Universiti Malaysia Perlis
Data Acquisition (DAQ)
MSU Agriculture Innovation Day
FPGA Vinyl to Digital Converter (VDC)
724 Temperature Calibrator
Data Acquisition Electronics Unit – Lecture 6
Presentation transcript:

Electronic Data Collection Colin S. Campbell Ph.D. Research Scientist Decagon Devices, Inc.

Outline Data collection for the early scientist Progress toward modern field techniques Converting electronics into information Electrical Engineering meets the scientist Assessing the requirements of a project Making the right system choice

Field research: Quantify physical environment Early pioneers in environmental biophysics Howard Penman at Rothamsted Research Station Manual readings or strip chart/disk recordings Sleepless nights Seminal paper on evapotranspiration Champ Tanner at U. Wisconsin Travel trailer

Changing world of measurements There’s got to be a better way All-nighters at research site not terribly popular Miss fast changes or events with human sampling No control of processes Goals Make unattended measurements Store measurements for analysis later Transform data into information and understanding

Requirements for field research Possible needs Sensors that generate electrical signals that can be correlated with environmental phenomena System to read electronic signals and store them Make decisions based on measurements Control external systems based on analysis

Modern field research Sensors Data logger No limit to parameters that can be measured Passion for instrumentation design Only challenge is to find correlations Indirect measurements Measuring one parameter and inferring the one of interest Data logger Basically glorified multimeter and oscilloscope Repository for raw sensor output Interprets electronic signals and stores them

Evolution of measurement: Temperature example First automation by strip chart recorder Change in temperature of bimetallic strip Deflection calibrated to known temperatures Temperature variation changed pen position Ink recorded changes over time Data evaluated by hand Widely used

Conversion to an electrical signal: The thermocouple Seebeck effect Two dissimilar metals jointed together produce voltage potential when differentially heated Potential related to temperature difference Correlation (copper-constantan thermocouple) ~ 40 mV per oC Measurement of minute voltage changes provides accurate temperature Assuming know the temperature of one junction Electrical measurement is accurate

Other measurement techniques: Temperature Thermocouple limitations voltage accuracy requirement reference temperature Alternatives Thermistor, platinum resistance thermometer Change electrical resistance with temperature Diode Voltage drop across a PN junction

Data loggers and sensors

Sensor signal types Four general types of electronic sensor output Voltage Probably the most common type Includes thermocouples, radiation sensors, some anemometers, etc. Current Often used over long cable distances Common to some measurement and control industries Pulse or switch closure Rain gauge, some anemometers, some soil moisture sensors, etc. Digital Typical of sensors measuring more than one parameter Allows for more than one signal per input location

Data logger types Plug and play (P&P) Decagon Em50, Em5b Onset Hobo CrossBow eKo Measurement and Control Systems (MCS) Campbell Scientific CR1000, 3000, etc. DataTaker DT80 National Instruments LabView

Choosing a data logger: Things to consider What electronic outputs do you need to measure? Voltage, current, pulse, digital How many sensors are you putting at each research site? How often will you be storing a measurement?

Choosing a data logger: Things to consider Will some measurements need to be made more often than others? >10 Hz (i.e. eddy covariance) 1 minute (i.e. radiation) Do you need to control anything with your system (lights, heater, valve, etc.)? Do you have the time or resources to program and setup the system?

Choosing the right system Control? Std P&P Sensor? MCS User needs No Yes

P&P MCS Limited Sensor numbers/types Extensive User Needs Sensor numbers/types Limited Extensive Power (batteries/solar Panels) Cost (data logger, enclosure, power) Low cost Feature rich Instrument enclosure Integrated Custom Expertise Simple setup Program P&P MCS

Choosing a data logger Plug-and-play data logger Built for specific sensor measurements or specific sensor types Allow only a minimum of configuration Date/time Measurement interval Sensor type Limited sensor inputs Low flexibility for sensor types

Plug-and-play data loggers Advantages Fast configuration Simple deployment No/low programming complexity Simple data collection and analysis Straight-forward sensor integration Low power consumption Price Disadvantages Limited sensor types Limited input ports Little or no configurability No event-based sampling No/little external control

Choosing a data logger Measurement and control systems (MCS) Build for general purpose measurement Measure most types of voltage, current, pulse, and digital sensors Highly configurable Many different measurement and control option Programming allows for multiple measurement intervals On board data processing and decision making High speed measurement Expandable Add additional sensor capacity Accurate May utilize high resolution signal processing for accuracy

Measurement and Control Systems Advantages Disadvantages Configurability Precision and accuracy Programmability Speed Decision making and control Data processing Programming Configuration Installation and setup Power

Characteristics to evaluate Required resolution and range Thermocouple 0.1o C resolution = 4 mV data logger resolution 50o C range = 2000 mV data logger range Water content sensor 0.1% VWC ~ 1 mV data logger resolution 100% VWC ~ 1000 mV data logger range Excitation Many sensors require a voltage be provided to the sensor Decagon EC-5 – 2.5 or 3V regulated Gill WindSonic anemometer – 12V unregulated Excitation requirements vary mV to 10s of volts Many data loggers have limited excitation options

Characteristics to evaluate (cont.) Analog to digital converter (ADC) Voltage and current measurements are made by an ADC Precision of ADC defines accuracy of the measurement Defined by bits i.e. 12 bit ADC  0 to 4095  2.5 V range  0.61 mV/bit Obviously not good enough for the thermocouple, but good for VWC 24 bit ADC  0 to 16777216  2.5 V range  0.15 mV/bit Good enough for thermocouples Noise rejection Multiple sources of ambient electrical noise 60 cycle from electricity, radio frequency

Data logger applications Making the decision Many choices available Sometimes confusion trying to decide which one will work the best Discuss some applications from personal experience Caveat: Vast majority of my experience is with Decagon and Campbell Scientific data logger Many other manufacturers that you may consider Delta-T, Onset, DataTaker, Stevens, Unidata, etc.

Rice net carbon exchange Conditional sampling Stored 77 different outputs CO2, H2O concentration (voltage output from IRGA) Pyranometer, quantum sensor, net radiation (mV) Water content (pulse count) Rain gauge (pulse count) 3-D sonic anemometer (digital) Data downloaded by cell phone (2.5 h away) 5 Marine batteries charged by 6-12V solar panels 2 CR10X dataloggers, 2 MUX, Relay driver Flexibility, control, programmability, storage, communication

Turf grass watering Control based on distributed water content sensors Turf field with pop-up sprinklers Decision: things to consider Control based on distributed water content sensors VWC at several locations Threshold values control solenoid values for sprinklers P&P data logger Easy to read VWC sensors Fast installation Low power requirements Data easily collected and graphed over radio or cell phone Often lack control capability MCS Required for system control Large sensor input capacity

Distributed field analysis of physical and morphological interactions Site description System choice 37 ha research farm Large topographical variation Goal Investigate water, temperature, and EC variation in relation to soil morphology 42 distributed profiles Measurement at 5 depths Plug-and-play logging system well suited for distributed networks Small number of sensors at each site Radio or cell phone communications Fast setup Low power use No requirement for control or specialized sampling

Fast, simple plot measurements Description Considerations Goal Compare performance of drought tolerant cultivars Requirements Soil moisture, temperature in plots Weather station parameter in central location Simple deployment P&P systems require no programming No specialized sample timing or control Self contained loggers require no enclosure setup or external power

Summary Data loggers simply measure and store electronic signals Art of instrumentation is to dream up new ways or correlating electronics to science Data logger choices are numerous Carefully determine all experimental needs Evaluate system specifications