What you should tell your patients about radiation Lisa Lowe MD, FAAP Professor, Univ of MO-Kansas City Pediatric Radiologist, Children’s Mercy Hospitals.

Slides:



Advertisements
Similar presentations
Radiation safety in CT.
Advertisements

Radiation biology and protection in dental radiology
TRAINING COURSE ON X-RAY FOR GP
7. RADIATION AND RADIATION PROTECTION
Update on MR Enterography PMA GI Conference January 4, 2011 Alvin Yamamoto, MD Commonwealth Radiology Associates.
When US? When CT? Fern Karlicki, MD.
Radiation Protection in Paediatric Radiology
Radiation safety in CT.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Pregnancy and Medical Radiation.
FPS HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENTFPS PUBLIC HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENT Medical Imaging Federal initiative Dr Aldo Perissino.
Radiation Dose in CT Scanning: A Team Approach
Assessing Risk from Medical Radiation
Lower Dosage CT-guided Lung Biopsy Protocol Maintains Quality, Minimizes Exposure Jeremy Collins, MD Pegah E, Lewandowski RJ, Yaghmai V, Nemcek jr AA,
Radiation Carcinogenesis Martin Brown. Two types of late effects of irradiation Deterministic (non-stochastic) effects –Severity increases with dose.
Business: Cell/Text: Presented by: Thomas J. LaRocca, M.S., D.A.B.R. Medical Physicist
Petra Lewis MD Professor of Radiology and OBGYN Geisel School of Medicine at Dartmouth.
CVT 102.  Time  Distance  Shielding.
Nuclear Weapons: The Final Pandemic Preventing Proliferation and Achieving Abolition Changing views of the biological effects of low-level ionizing radiation.
The scientific unit of measurement for radiation dose, commonly referred to as effective dose, is the millisievert (mSv)
Biologic Effects. Biological Interactions Radiation Ultrasound MRI.
BEIR VII: “The very error of the moon.” Othello, Act II Herbert L. Abrams.
Quyen Huynh OHSU SOM, MS4. CT radiation and use Physician and patient understanding Radiation terms Cancer Risk with CTs Ways to decrease radiation to.
Special Radiographic examination
Radiation and Computed Tomography in Children…
WHICH ONE DOESN’T FIT? THAT’S MORE LIKE IT.. RADIATION DOSAGE CXR= 1/100 Background Radiation Background Radiation/yr Sea level = 3 milli Sieverts 100.
Maximum Permissible Dose (MPD)
October 27, 2009MDCH/RSS CON Seminar 1 Computed Tomography (CT) Proposed Rules for Radiation Safety John Ferris, Health Physicist Radiation Safety Section.
Radiation Dose in MS-CT coronarography Ladislav Pavic, MD, PhD Sunce Clinics Zagreb / Sarajevo Croatia / Bosnia & Herzegovina.
Radiation Dosimetry of the Patient
Optimizing Patient Radiation Dose
Finding N.E.M.O. Marvin R. Balaan, MD, FCCP System Division Director, Division of Pulmonary and Critical Care Medicine Allegheny Health Network, Pittsburgh.
What is CT?  CT scans use x-rays generated from the source that is rotated around the body to create 3 dimensional pictures of the body. What is an x-ray?
Radiation Protection of Patients Unit
Radiation Safety in Children
2006 CRCPD NEXT survey of Computed Tomography David Spelic, Physicist Center for Devices and Radiological Health Food and Drug Administration.
The ICRP System of Protection Applied to Medical Exposures
Knowledge of radiation exposure in common radiological examinations amongst radiology department staff AL Chang, LH Cope, DH Keane, S Wood Presented by.
Health Effects of Radiation. What Radiation Affects Directly or indirectly, radiation affects the DNA in cells DNA controls the cell’s function and ability.
Radiation Health Effects
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
Diagnostic Imaging and Malignancy Risk Emergency Medicine Grand Rounds June 12, 2008 June 12, 2008 Dr. Jay Green Emergency Medicine Resident, PGY-2.
BEIR VII Implications of the Report for the Future of Medical Imaging G. Donald Frey, Ph.D. Department of Radiology Medical University of South Carolina.
Radiation and Cancer Risk A topical update with the best available data Donald E. Mosier MD PhD October 19, 2013 A topical update with the best available.
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
Introduction To Radiation Protection Kyle Thornton RADL 70.
Image Gently : An Educational Campaign for Everyone Kimberly E. Applegate, MD, MS Steering Committee Member, Alliance for Radiation Safety in Pediatric.
1 Sensitivity to Radiaiton & Calculating pt dose Stat ch 8 Bush ch 40.
A Pain in the Neck! Too Many Normal Paediatric Cervical Spine CTs in trauma? SC Shelmerdine, BN Bhaludin, WY Mok, L Woods, V Cook Epsom & St Helier University.
Part 2.
1 Radiation Dosimetry in X-Ray Computed Tomography (CT): Standardization and Regulation Stanley H. Stern, Ph.D. Center for Devices and Radiological Health.
©2015 MFMER | slide-1 How Does Patient Radiation Exposure Compare with Low Dose O-Arm vs. Fluoroscopy for Pedicle Screw Placement? a,b Alvin W. Su, MD,
Page 1 Examination of nurse practitioner educational preparation to appropriately Nurse practitioner educational preparation in imaging Title of study:
Radiation Sources in medicine diagnostic Radiology
Week 2 :Radiation Protection
CT Radiation: What is the Radiation Risk to Your Patient?
Introduction Radiology is the branch of medicine that deals with imaging technology for diagnosing and treating illness and disease. It includes X-Rays,
IS THERE A RATIONAL APPROACH TO RADIATION RISK? Philip F. Judy Ph.D. Department of Radiology Brigham and Women's Hospital New England AAPM Chapter Meeting.
Radiation hazards Mamoun Kremli, SA AOT Basic Principles Course.
Introduction Your role Communicating risk Conclusions Radiation risks.
Wednesday Case of the Day History: CT pulmonary angiography (image shown) was performed on a 24-year-old female patient with pleuritic chest pain and increased.
Cancer Education Day Lung Cancer Screening Update Kirenza Francis, MD, FRCPC, DABR Windsor Radiological Associates May 13, 2016.
Organ dose and effective dose in Full spine Eaxamniations by EOS® Stereo-radiography with micro-dose settings. A study on anthropomorphic phantoms describing.
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Jennifer Koay, MD Assistant Professor Department of Radiology
For healthcare professionals
Radiation Protection in Dental Radiology
Health and Biological Effects of Radiation
Health and Biological Effects of Radiation
INTRODUCTION TO RADIOLOGY IMAGING MODALITIES Asilah Al-Obeidani.
Presentation transcript:

What you should tell your patients about radiation Lisa Lowe MD, FAAP Professor, Univ of MO-Kansas City Pediatric Radiologist, Children’s Mercy Hospitals & Clinics

Learning Objectives After this talk, learner should be able to: Explain general radiation risk to patients and parents State ways to lower radiation exposure in children Be able to list helpful resources to determine the best radiology test

Outline History and Background Radiation Risk Increased use of CT Image Gently Helpful resources What can you say? What can we do?

History: Roentgen discovers the X-ray! Dec 1895 – Publication 1 week later - radiograph of wife’s hand

History: Radiology - fastest translational research Mid 1896, in practice, including fluoroscopy < 9 months from publication

History: X rays became a public spectacle Patented shoe fitting fluoroscope –Bloomingdales FASCINATION!

History: Side effects appeared later Vision impaired Skin injury Hair loss

History: Risk of radiation “exposed” 1956 Alice Stewart, MD, reports X-Ray risks to fetuses –Argued no radiation was safe –Radiation effects grossly underestimated 1945 US drops atomic bomb –Life Span Study cohort of atomic bomb survivors –> 50 years –Hiroshima Nagasaki –Increased risk of solid cancers –Children highest cancer mortality rates

Radiation risk: Biological effects of radiation Damage to DNA Damage to DNA is rapid Damage to DNA may lead to genomic instability Induction of cancer takes many years

Children are more radiosensitive Longer lifetime to manifest radiation-induced injury (cancer, cataracts) Children 2-10x more sensitive than adults Radiation Risks in Children: No Debate

Increased use X-rays: Invention of CT 1979 Nobel Prize in Physics Allan Cormack Godfrey Hounsfield

Increased use: Helical CT Significant increase in the use of CT from 2001 to 2006 –Increase of 10% per year 62 million CTs done per year –6-11% of all CT’s done in children Initially multidetector and 3D CT increased radiation doses by 3 to 10X 50% of all medical radiation ?? Dose quantification Arch, Michael and Donald P. Frush. “Pediatric Body MDCT: A 5-year follow up survey of scanning parameters used by Pediatric Radiologists.” AJR 2008; 191:

Increased use of CT: AJR Feb 2001 Increased use of CT: AJR Feb 2001 < 20% cases 1 in ,000

Brenner et al: AJR 2001 Increased use & radiation risk Each exam (therefore dose) is cumulative

Hall. Pediatric Radiology. Apr 2002 Increased use & radiation risk AGE at exposure is most important risk factor Females 2X males –Breast –Thyroid

Image Gently Campaign Society for Pediatrics Radiology (SPR) & American Academy of Pediatrics (AAP) plus 33 other medical organizations formed the Alliance for Radiation Safety in Pediatric Imaging Represents over 400,000 healthcare professionals promoting appropriate and high quality CT for children

Image Gently Campaign ALARA principle –As Low As Reasonably Achievable 4 Image Gently guidelines: –Scan only when necessary –Scan only indicated region –Reduce or “child-size” the radiation dose –Scan once –

Helpful resources: ACR website Imaging guidelines and appropriateness criteria on the Amer College of Radiology (ACR) website: – &SID=1&DID=14800&CID=1848&VID=2&DO C=File.PDFhttp:// &SID=1&DID=14800&CID=1848&VID=2&DO C=File.PDF

Helpful resources: AAP website Radiology section of the AAP Imaging guidelines: g/sections/radiolo gy/default.cfmRad iation safety information for parents & pediatricians g/sections/radiolo gy/default.cfm

Radiation report card

Helpful resources: CMH Radiology website Children’s Mercy Hospital Radiology website

Sample newsletters: Image gently campaign

How do we respond? One size does NOT fit all We all must ask? Appropriate to do exam? Appropriate timing of exam? Appropriate modality?

Radiologists’ responsibility  Understand radiation doses  Review requests for higher dose studies  Discuss with clinicians and parents/patients PRN  Child size technical factors How Do We Respond?

Examples Sinus CT –Old: 150 mAs –New: 30 mAs Scoliosis CT Craniosynostosis CT 5x lower dose! }

Pediatricians’ responsibility:  Understand radiation doses of modalities  Know which facilities are “kid friendly!  Don’t ass-u-me?  ASK, even demand!  Order on medical indications not parental/legal pressure  Discuss options with radiologist PRN  Consider information for parents PRN How Do We Respond?

Talking to parents 1.Discuss risk vs. benefit 2.Use websites for more detailed explanations 3.Compare to other every day risks

compared to background (3.5 mSv/yr) Typical radiation doses compared to background (3.5 mSv/yr) Procedure Effective dose Comparable background dose* Chest x-ray0.02mSv1 month VCUG0.3mSv3 months Dental X-rays0.9 mSv6 months Lumbar spine1.3 mSv7 months CT head2mSv8 months Upper GI3mSv1 year Barium enema7mSv2.3 years CT abdomen10mSv3 years 1 Airline flight0.3mSv2-3 months *Average background dose is 3.5 mSv/year

Risk of death from various activities ActivityRisk of death per million/year Having a chest X-ray 1 Visiting Denver for 2 months 1 Traveling 5,000 by air 5 Fishing (drowning) 10 Traveling 1,500 miles by car 40 Motorcycling for 1, Smoking 1 pack/day 3,500 Being > 55 years age10,000

What is CMH doing to lower doses? Pediatric radiologist is actively involved Using US and MRI when possible –Appendicitis and screening Pulsed fluoroscopy –UGI/VCUG – Up to 10X less dose

What is CMH doing to lower doses? Pediatric radiologist is actively involved Child size all CT doses –New protocols: 5x less dose Av CT dose: 2009 –CMH: 1025 mSv –Other providers: 1818 mSv 44% less radiation!!

What is CMH doing to lower doses? We make sure your patient gets the: Right test (best test with least radiation) –? US or MRI Right time –? Does something else need to be done first? Right way (individualize protocols) –? Contrast or not –Lowest radiation dose possible 44% less for CT on average

Thanks for your attention Questions?