Calibration of extremity dosimeters for Tc-99m, Cs-137 and X-ray David Rawlings Regional Medical Physics Department Newcastle-upon-Tyne.

Slides:



Advertisements
Similar presentations
Quality Control in Diagnostic Radiology
Advertisements

X-Ray Beam Restrictors
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
Brachytherapy Rooms Mr John Saunderson
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
CVT 102.  Time  Distance  Shielding.
Algorithms used in heterogeneous dose calculations show systematic error as measured with the Radiological Physics Center’s anthropomorphic thorax phantom.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Optimisation of X-ray micro-tomography to perform low-dose imaging of highly-dosed gels P.M.Jenneson, E.C.Atkinson, P.Wai and S.J.Doran In 1993, Maryanski.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Kilovoltage X-ray Dosimetry
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
Factors affecting the X-Ray output
X-Ray Production & Emission
X-Ray Production & Emission
Quality Control Rad T 110.
Linac Beam.
Resident Physics Lectures Christensen, Chapter 6Filters George David Associate Professor Department of Radiology Medical College of Georgia.
External Beam Radiotherapy
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Étienne Létourneau, Fabiola Vallejo Castaneda, Nancy El Bared, Danny Duplan, Martin Hinse Presented by: Étienne Létourneau 2015 Joint Congress, Montreal,
Radiographic Dosimetry
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Chapter 3 Radiation Safety Vet Tech Institute. Radiation should be respected not Feared! Safety is Always important! Safety is Always important! Stray.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
Comparison of Clinical Parameters for Proton Therapy in the United States Paige Summers, MS.
ACR Full-Field Digital Mammography Accreditation Update
Quality Control Rad T 110.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
The RPC Proton Therapy Approval Process
S Optical CT scanning of PRESAGE TM polyurethane samples with a CCD-based readout system S J Doran 1*, N Krstajic 1, J Adamovics 2 and P M Jenneson 1 1.
RAD 254 Chapter 15 Radiographic Technique 4 primary exposure factors are: kVp, mA, time, distance.
HEALTH PHYSICS TERMS l RAD (Gy) l mRad l R l mR l Rem l ALARA l NCRP.
Đ. Milković, M. Ranogajec-Komor, S. Miljanić, Ž. Knežević and K
Araki F. Ikegami T. and Ishidoya T.
Radiation Quality Chapter 4. X-ray Intensity Intensity: the amount of energy present per unit time per unit area perpendicular to the beam direction at.
International Atomic Energy Agency ASSESSMENT OF OCCUPATIONAL EXPOSURE DUE TO EXTERNAL RADIATION SOURCES AND INTAKES OF RADIONUCLIDES Calibration and Test.
RAD 354 Chapt. 8 X-ray emission
RAD 354 Chap. 13 Radiographic Technique
Optimisation in digital radiography 9 October 2015 Radiation Dose Metrics Dr Tim Wood Hull and East Yorkshire Hospitals NHS Trust
Introduction The Radiological Physics Center (RPC) anthropomorphic quality assurance (QA) phantom program is one tool the RPC uses to remotely audit institutions.
Determining Radiation Intensity
Part No...., Module No....Lesson No
Week 2 :Radiation Protection
What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.
Grup de Física de les Radiacions 24 th International Conference on Nuclear Tracks in Solids CALIBRATION OF THE UAB PADC BASED NEUTRON DOSEMETER Measurements.
实验十四 紫外线灭菌  一、实验背景及目的:  灭菌是一种杀灭微生物的措施。紫外线灭菌 是物理灭菌因素之一。  1. 了解紫外线灭菌的原理;  2. 学习、掌握紫外线灭菌的方法。 版权所有 未经作者同意 请勿使用.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
MAIN FEATURES FOR CALIBRATING DOSEMETERS ORAMED WP5 J.-M. Bordy Laboratoire National Henri Becquerel (CEA/LIST/LNHB), France ORAMED 2011 January 2011.
Basis of Mammography F. Milano Dept. Clinical Physiopathology University of Florence
IAEA International Atomic Energy Agency Lecture 7 – Calibration and Testing of Radiation Protection Instruments Postgraduate Educational Course in radiation.
Diagnostic Equipment Quality Control
Ch 36 Radiation Protection Design
6th European ALARA Network Workshop Madrid, oct. 23rd 2002
AUBERT Bernard*, GUILABERT Nadine°, LAMON Annick* and RICARD Marcel*
Introduction To suggest a new type Dual X-ray imaging method, we set the optimum thickness of scintillator for low and high energy. Then, we measured.
Resident Physics Lectures (year 1)
Stat Ch 8 & 9 RHB – Rad Prot Syllabus
David Sutton or Colin Martin But Borrowed from Jerry Williams
Rad Protection & Radiobiology review
Factors Effecting the Production
Resident Physics Lectures (Year 1)
Resident Physics Lectures (year 1)
Resident Physics Lectures (Year 1)
Test tool for assessing lead equivalence in protective lead apparels
Intercomparison on Personal Dose Equivalent (Hp(10))
Hp(10) irradiations for personal dosimetry traceability
Effects of tube voltage, filtration, and dose rate on the color difference of the indicator. Effects of tube voltage, filtration, and dose rate on the.
Presentation transcript:

Calibration of extremity dosimeters for Tc-99m, Cs-137 and X-ray David Rawlings Regional Medical Physics Department Newcastle-upon-Tyne

Introduction Extremity TLD Finger dose H’(0.07) in mSv Calibration on phantom as per ISO (1) Perspex rod 300 mm, 19mm diameter Air Kerma rate determined Published conversion to H’(0.7) (2) Basis for a UK inter-comparison 1 Bohm et al, Rad Prot Dosim (1999) 2 Grosswendt B, Rad Prot Dosim (1995)

Irradiation Cs-137 and Tc-99m Circular jig 6 Perspex finger rods at 30cm Low scatter source support Cs-137: sealed source 3.7GBq Cs-137: minutes Cs-137: 3mm paper build up Tc-99m: solution 5ml 0.5GBq Tc-99m: overnight Manual timing

Irradiation 80kVp ISO X-Rays Clinical Darpac kVp nominal 5mA Extra collimation: Extra filtration: 0.5mmCu 1mmAl ISO 4037 Broad series 1 st HVL 0.35mmCu 2 nd HVL 0.51mmCu Primary beam at 45 degrees Radiographic alignment Perspex finger rod at 1m

In conclusion… Has been used for most common types of extremity TLD Follows recommended calibration on finger dosimeters