502 NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways 2011 Edition.

Slides:



Advertisements
Similar presentations
National Electrical Code Article 310
Advertisements

4 Wiring Systems. 4 Wiring Systems Objectives Know where to find codes and authorities for an installation. Recognize the marks of the most popular.
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Grounding Electrodes.
Performance and Safety Issues Found in Offshore Communications Cable Products Improvements Needed to Conformance Testing Programs in North America October.
 ELECTRICAL SAFETY Gerald P. Robinson Jr., P.E. – Hatch Mott MacDonald.
Thermostats, Pressure Switches, and Other Electric Control Devices
Assumption University Thailand EE4503 Electrical Systems Design Raceways 1.
OSHA Region IV Electrical Outreach Construction Industry Photos 29 CFR 1926 Regulations.
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
FCIA CODE EFFORTS FCIA Spring Conference 2003 By William E. Koffel, P.E. Koffel Associates, Inc.
Telecom Cabling Grounding and bonding.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
Master Examination Practice Drill # O 1. Given: Two (2) rigid metal conduits (RMC) are to support a weatherproof 18 cu. In. device box, with threaded.
Master Examination Practice Drill # Ted “Smitty” Smith.
Emerging Standards and their effect on Exterior Continuous Insulation in Commercial Wall Construction.
Through Penetration Firestops.
Conquest FireSpray Fire Rated Ductwork Warren Michigan.
Master Examination Practice Drill # O Where a hotel has a stationary electric sign installed inside a decorative fountain, the sign shall be at.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Bonding and Installation Requirements for CSST Gas Piping Systems April 2009.
Master Examination Practice Drill # (16) O 1. In commercial and industrial establishments, all 15- and 20- ampere, single-phase, 125 volt receptacles.
Impact of Bonding Requirements for CSST on LP-Gas Piping Systems April 2009.
2011 NEC ROP - CMP 5 Report to SCC 18
2014 CHANGES TWO MINUTE DRILL COPYRIGHT TED “SMITTY” SMITH ©2014.
 Rate (how fast) at which charges pass a given point  Measured in Amperes or amps  Current (I)  Electrons moving in a wire make up current and provide.
Copyright 2005 Ted "Smitty" Smith Two Minute Drill Number Three Improving your skill in code Look Up Increasing Speed Drill.
INTRUSION ALARM TECHNOLOGY
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
TTS 171 : PART 1: 2002 ANNEX E PRESENTER WINSTON THOMAS ELECTRICALINSPECTOR 1 ELECTRICAL INSPECTOR 1.
Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Two Minute Drill #10 Copyright 2005 Ted "Smitty" Smith.
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
Calculation Speed Drill # NEC
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
Speed Drill 51 Wireways and Raceways.
Engineering Analysis of NFPA 285 Tested Assemblies
No content in the brand signature area No content in this area CYAN RGB= 000,153,255 DARK GREY RGB= 075,087,095 DRAKA BLUE RGB= 000,051,153 DRAKA Colors.
Electricity on the Move. Current Electricity Unlike static electricity, which does not move except when discharged, current electricity is a continuous.
Fire Resistance Rated Truss Assemblies Educational Overview.
2014 NEC C ODE C HANGES C LASS P ART II Ted “Smitty” Smith 8/15/2014 E Light Electric Services, Inc.
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Building Construction
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
Electric Current Chapter 34.2, 34.4, 34.5, and Notes.
INTERIOR WIRING & DISTRIBUTION
HOW TO SIZE ELECTRICAL CIRCUITS
License Examination Practice Drill
E4 Electrical Installation
E4 Electrical Installation
Smitty’s Two Minute Drill Mixed Content -05
Types of Cables.
Electric Current Chapter 34.
Electric Circuits Exploration Go to the interactive. You will use only need to use the battery, lamp (bulb), and wire. Complete.
AFCI Protection: AFCI Receptacles and the NEC
Conductors and Cables 2017 NEC
ANNEX E PRESENTER WINSTON THOMAS
Resistance Lesson 8 November 16th, 2010.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Fabric Air Dispersion Systems
General Requirements of NFPA 101
Two Minute Drill: Raceways and Boxes 2017
EET 323 – Electrical System Design Lecture 9: Grounding
Two Minute Drill Number 29- Conductors and Raceways
Insulators and Conductors
Instructor: Radian Belu, PhD
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Smitty’s Two Minute Drill Services, Feeders, and Branch Circuits 1
FIRE ALARM DRILL 26 © Ted Smith 2017.
Chapter 24 Electrical Circuits.
Presentation transcript:

502 NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways 2011 Edition

NFPA 502 Chapter Emergency circuits installed in a road tunnel and ancillary areas shall remain functional for a period of not less than 1 hour for the anticipated fire condition, meeting one of the following methods:

NFPA 502 Chapter 12 (1) A fire-resistive cable listed for 2 hours in accordance with ANSI/UL 2196 or other equivalent internationally recognized standards to 950°C (1742°F) when approved by the AHJ. (2) Circuits embedded in concrete or protected by a 2- hour fire barrier system in accordance with UL The cables or conductors shall be thermoset and shall be suitable to maintain functionality at the temperature within the embedded conduit or fire barrier system.

How to achieve a 2- hour fire resistive cable rating

U L hours Circuit Integrity test Environment: Large scale wall oven (14 x 15 x 3) Temperature Profile: Slow Rise Follows ASTM E minutes hour hour Cable are energized at application voltage 120V or 480V light bulbs set up Water impact test after fire test

ASTM E – 119 Time/Temperature Curve 1850 ⁰ F 2 HR

UL 2196 Fire Test Systems that require a raceway are tested with the minimum raceway diameter and the minimum raceway type with their respective coupling(s). Raceways having larger diameters are acceptable. Raceways with greater wall thickness are also acceptable. Intermediate metal conduit (IMC) or rigid metal conduit (RMC) are acceptable for use in systems where electrical metallic tubing (EMT) is specified.

UL Gas Burners

Wall Setup

Back side of wall

UL 2196 Video

UL 2196 – After 2 Hours

Water Impact Test

UL 2196 Assumptions Passing the smallest qualifies the largest – Assumption is the smallest is most difficult to pass – Passing 2 14AWG qualifies up to 750MCM Also qualifies single or multiple conductors Passing in EMT qualifies IMC and Rigid – Assumption is that EMT is the thinnest wall and most difficult to pass.

UL 2196 Fire Test FLAW Systems that require a raceway are tested with the minimum raceway diameter and the minimum raceway type with their respective coupling(s). Raceways having larger diameters are acceptable. Raceways with greater wall thickness are also acceptable. Intermediate metal conduit (IMC) or rigid metal conduit (RMC) are acceptable for use in systems where electrical metallic tubing (EMT) is specified.

UL 2196 Test Using RMC

RHW 12 AWG in RMC

RHW 8 AWG in RMC

Zinc Analysis by UCONN

Think Zinc July RSCC performs testing at UL and has failures in RMC. Internal testing helps us understand causation to be Zinc Notification to UL of issue September 2011?? U Conn metallurgical lab confirms zinc from interior of conduit is failure mechanism. U Conn report provided to UL as substantiation

UL Response Sent to all manufacturers on June 12, 2012 (10 months) Citation from letter:

UL Statement 9/12/2012 Suspends all cable listings to UL 2196 Fire Resistive, Fire Resistant and Circuit Integrity Cables UL has recently conducted research on a wide array of current products and systems originally certified under UL 2196, Tests for Fire Resistive Cables and ULC-S139, Standard Method of Fire Test for Evaluation of Integrity of Electrical Cables and determined that they no longer consistently achieve a two-hour fire-resistive rating when subjected to the standard Fire Endurance Test of UL2196 or ULC-S139. Consequently, UL and ULC will not be able to offer certification to the currently existing program related to these standards. As a result, manufacturers are no longer authorized to place the UL mark or ULC mark on the following products: UL Classified Fire Resistive Cable (FHJR) ULC Listed Fire Resistant Cable (FHJRC) UL Listed cable with "-CI" suffix (Circuit Integrity)

NFPA 502 Write the minimum requirements for fire- resistive cable in Chapter 12 – Identify minimum time required for survivability 2 hours? – Identify fire test parameters ASTM E-119 – Identify minimum sample length 8 feet – Make it clear what needs to be tested