Prepared by Tony Weekes Husam Al Hadidi Brian Archer.

Slides:



Advertisements
Similar presentations
Power System Damping in Iceland based on phasor measurements
Advertisements

Spinning Reserve from Load Consideration of a Trial at Xcel Energys Cabin Creek Station Presentation to CMOPS January 7, 2005 John Kueck ORNL Brendan Kirby.
Using Synchrophasors for Preventing Cascading Outages
Chapter 10 Stability Analysis and Controller Tuning
EE357 Control System I - Lec B2 (2010W) - Introduction.
Multi Functional Digital Fault Recorder
Development of Damping Algorithm Olof Samuelsson Industrial Electrical Engineering and Automation
and Trend for Smart Grid
Frankfurt (Germany), 6-9 June 2011 Douglas Wilson Psymetrix Ltd, UK Douglas Wilson Psymetrix Ltd, UK D. Wilson – UK – Session 4 – Paper ID 0497 Connection.
Synchrophasors: Improving Reliability & Situational Awareness
Sinusoidal Waves. Objective of Lecture Discuss the characteristics of a sinusoidal wave. Define the mathematical relationship between the period, frequency,
Loop Shaping Professor Walter W. Olson
1 1 Office of Science Lawrence Berkeley National Laboratory Distribution µ PMU Applications Joe Eto Emma Stewart
Introduction to Phasor Measurements Units (PMUs)
Rudolf Wieser, Matthias Baechle, Valerijs Knazkins – ATPE
Damping assessment using relative phase information from PMU data
PRESENTATION FREQUENCY CONTROL
6/9/2015www.noteshit.com1. AMPLIFIERS AND OSCILLATORS 6/9/2015www.noteshit.com2.
Ee392n - Spring 2011 Stanford University Intelligent Energy Systems 1 Lecture 3 Intelligent Energy Systems: Control and Monitoring Basics Dimitry Gorinevsky.
Control System Design Based on Frequency Response Analysis
Design of a Control Workstation for Controller Algorithm Testing Aaron Mahaffey Dave Tastsides Dr. Dempsey.
CAISO Update JSIS Meeting March, Infrastructure 92 Connected PMUs 64 Substations 7 PDCs reporting (BPA, PG&E, SCE, SDG&E, APS, SRP and NVP) Redundant.
Enhancing Paper Mill Performance through Advanced Diagnostics Services Dr. BS Babji Process Automation Division ABB India Ltd, Bangalore IPPTA Zonal Seminar.
Power Systems Consulting and Software 4 March 2004 BWEA Conference: UK Offshore Wind 2004 Integration of Offshore Wind Farms into the Local Distribution.
Advanced Phasor Measurement Units for the Real-Time Monitoring
EE136 STABILITY AND CONTROL LOOP COMPENSATION IN SWITCH MODE POWER SUPPLY Present By Huyen Tran.
Small Signal Stability Analysis Study: study prepared by Powertech Labs Inc. for ERCOT Vance Beauregard AEP 9 April 2002.
Review of BPA Voltage Control Conference
Synchrophasor Measurement Implementation in ERCOT
Automatic Control Theory-
Monitoring of Active Distribution Networks in Steady State and Transient Conditions by means of accurate synchrophasors measurements Mario Paolone École.
Synchrophasor: Implementation,Testing & Operational Experience
Lessons Learned from the Texas Synchrophasor Network by Presented at the North American Synchrophasor Initiative (NASPI) Meeting Toronto, Ontario Thursday,
Chapter 13 AC Measurements. 2 Objectives –After completing this chapter, the student should be able to: Identify the types of meters available for AC.
Page 0 Eastern Interconnection Phasor Demonstration Enhanced Wide-Area Visibility In the Eastern Interconnection for Reliability Management Transmission.
Unit 5: Feedback and control theory An Introduction to Mechanical Engineering: Part Two Feedback and control theory Learning summary By the end of this.
1 Application of Synchrophasor Technology To CREZ System CREZ Technical Conference January 26, 2010 Navin Bhatt American Electric Power.
2009 West-North Stability Limit Study Reliability Assessment Group ERCOT System Planning Phase II –Effects of Adding PSS on System Limits Regional Planning.
CASE STUDY Disturbance event comparing PMU and SE voltage angle difference in ERCOT Prakash Shrestha Operations Engineer Advanced Network Application.
Application and Implementation of State Estimator at Idaho Power Company S. Kincic and M. Papic.
EWEC 2007, MilanoMartin Geyler 1 Individual Blade Pitch Control Design for Load Reduction on Large Wind Turbines EWEC 2007 Milano, 7-10 May 2007 Martin.
Power PMAC Tuning Tool Overview. Power PMAC Servo Structure Versatile, Allows complex servo algorithms be implemented Allows 2 degree of freedom control.
A Trust Based Distributed Kalman Filtering Approach for Mode Estimation in Power Systems Tao Jiang, Ion Matei and John S. Baras Institute for Systems Research.
November 16, 2012 Synchrophasor Meeting Dynamic Model Validation Project Jonathan Rose Engineer, Resource Integration Sidharth Rajagopalan Engineer, Dynamic.
EE2253 CONTROL SYSTEM PRESENTED BY S.S.KARTHIKA, AP/EEE
DC-DC Fundamentals 1.5 Converter Control. What is Converter Control? A converter can provide a constant voltage output at various condition because of.
TIMING APPLICATIONS OF GPS High Energy Transmission with High Precision GPS Time Gaurav Sharma John Hannah Vivekanand Sivaraman.
Imagination at work. Paddy McNabb Senior Engineer January 2016 Grid Stability Applications Wide Area Monitoring System.
ANALOG ELECTRONICS. PREPARED BY: KAMLESH ROHIT :
1 Dr.Wang Yingtao Engineer Power System Department CEPRI,China Nov 2006 R&D OF REAL TIME DYNAMIC MONITORING SYSTEM IN CHIHA.
Discovery Across Texas: Technology Solutions for Wind Integration in ERCOT Using Synchrophasor Technology for Wind Integration and Event Monitoring in.
2017 WECC JSIS Report March 21, 2017.
ISO-NE Synchrophasor Related Projects
Digital Control CSE 421.
IG BASED WINDFARMS USING STATCOM
Wide Spread Power Grid Blackout Prevention
Optical PLL for homodyne detection
PMU Emulator for Power System Dynamics Simulators
APPLICATIONS OF GPS IN POWER ENGINEERING
NERC Update: Current Activities Ryan Quint, Ph.D., P.E.
DEC System Voltage Planning - June 2018
Gaurav Sharma John Hannah Vivekanand Sivaraman
Peak’s Synchronized Measurements and Advanced Real-time Tools (SMART) Working Group (initiated in Oct-2017) Focus on operationalizing Synchrophasor tools.
Gaurav Sharma John Hannah Vivekanand Sivaraman
NASPI PMU Data Application Classification
Wind Farm Oscillation Detection and Mitigation
2017 WECC JSIS Report March 21, 2017.
WISP Follow on Reporting.
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
NASPI PMU Data Application Classification
Presentation transcript:

Prepared by Tony Weekes Husam Al Hadidi Brian Archer

Topics of Discussion Description of Manitoba WAMS Introduction to Birchtree SVC Project Commissioning Results Lessons Learned and Future Road Map

OrganizationPDC Contracted Connected PMU Confirmed Connected Sites Devices Ameren11216 American Trans Co.N/A 1 5 Duke Energy11164 Great Rivers Energy1182 Hoosier Energy1179 Indianapolis P&L1167 International Trans Co Manitoba Hydro21226 MidAmerican Energy10120 Minnesota Power1141 Montana Dakota Utilities0050 Northern Indiana Public Service3182 Ottertail Power2163 Vectren1030 WAPA0040 XCEL Energy00110 TOTAL

Need for wide Area Measurements Typical PSS tuning monitors local signals Problems can arise with fighting between controllers Advantage of monitoring a wide area can be addressed with synchrophasors

WAMS Phasorpoint tool used primarily to see the modes on the system

Phasor Point Mode Charting Mode Power Path

Sites Chosen known inter-area modes in our Northern ac. sensitivities of modes to various power flow conditions Upcoming projects in Northern ac Future sites will increase from 6 to 30 PMU locations Using existing TFR devices

Birchtree SVC Controller

Power Oscillation Damper (POD)

Commissioning Objectives Transfer function verification of the SVC voltage and POD controllers Tuning the POD to provide good damping performance for the modes within the frequency range of interest 0.5 to 0.9 Hz Minimize the interaction between the Ponton SVC and Birchtree SVC Optimize the Birchtree SVC POD and Ponton SVC SDC settings for most northern ac system generation patterns and operating conditions

Risks and Mitigations Output is correctly controlled from input, as expected Check the degree of movement in the rest of the system in response to a step change Confirm consistency with time-domain measurements Decide criteria for “unacceptable” oscillations. Switch controllers off one-by-one or plant-by-plant, separated by a period of time.

System Frequency Response Model verification (frequency response) of SVC POD design The frequency response characteristic (magnitude and phase) of the transfer function between Birchtree SVC input and voltage angle (frequency Phase Magnitude

Faciltity and Phasor Point screen

Mode Trending Root locus of mode Observability of the mode over time Trending and verification of damping controller performance

Commissioning Results

Unexpected Results Captured Mode increases with lower power Initial response of POD with other settings Clock error

Cont…..System Baselining

April 25, 2011 – 11:14:00 to 11:19:00 – Approx. 2 hours before event Cont…..System Baselining Clock Errors

POD First Settings

POD Second Settings

Open/Close line test

Open/Close Line Test

SLG Fault

Lessons Learned Channel Selection (problem with power calculation if switching occurs) Importance of doing a frequency response intially to confirm models Real time feedback to see if and how multiple power system controllers may fight with each other. Clock errors can be significant and need mitigation measures both in real time and regular maintenance Integration of analog signals in the future to PMU data (also significance of proper channel selection and sites) Unusual Modes were identified as consistently observed on the system but low in magnitude

Future Road Map Model verification (complement NERC testing) Investigations to increase transfer limits through compound event analysis Investigation of islanding and coherency of generators Integration with real time tools that use power models (benchmarking) EMS state estimator improvement especially after the full complement of PMUs are on the system

Questions ??

May 3, 2011 Cont…..System Baselining

May 25, 2011 Cont…..System Baselining

Bode Plot (Lead /lag Block)

Simulation Results Time Domain

April 25, 2011 – 13:13:00 to 13:18:00 – During the time of the Event Cont…..System Baselining

May 3, 2011 – 09:00:00 to 09:05:00 – About a week after the event Cont…..System Baselining

Cont….Simulation Results Frequency Domain

Commissioning tests Frequency sweep and discrete frequency injection MW transfer change 5% Step response of genertor exciter Open/ close line switching SLG Fault

Kettle Exciter Step Change

Small-signal stability problems Local plant mode oscillations: Rotor angle oscillations of single generator or single plant against the rest of the system (0.7 to 2.0 Hz). Intermachine/Interplant mode of oscillations: Rotor angle oscillations between a few generator close to each other (0.7 to 2.0 Hz). Interarea mode oscillations: Oscillations of groups of generators in one area swinging against a groups of generators in another area (0.1 to 0.7 Hz). Control mode oscillations: Associated with control of equipment such as generator excitation systems (2.0 to 5.0 Hz).

Open/Close Line Test

Open/Close Line test

Commissioning Plan Time domain and frequency domain simulation studies System Baselining (using the PMU and Psymetrix tools) Test schedule & planning Commissioning test process Results analysis