XDX® A Discussion Concerning Heat Exchangers: Shell and Tube Plate and Frame.

Slides:



Advertisements
Similar presentations
Basic Refrigeration, Its Components, and Its Cycle
Advertisements

Automotive A/C systems
Refrigeration Basics 101 By: Eric Nelson.
Thermostats, Pressure Switches, and Other Electric Control Devices
Student CD for Commercial Refrigeration for A/C Technicians
Basic Refrigeration Cycle
Refrigeration Flow Control
KE2 Evaporator Efficiency
Operated by the Southeastern Universities Research Association for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Page 1.
Refrigeration Components
HVACR312 - Refrigeration Metering Devices.
C oncerns Ltd ool Energy Efficient Refrigeration Jane Gartshore, Cool Concerns Ltd.
COMMERCIAL REFRIGERATION
COMMERCIAL REFRIGERATION
Product Introduction.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Oceanic Thermal Energy Conversions Group Members: Brooks Collins Kirby Little Chris Petys Craig Testa.
Cold-Plus™ by TRIFECTA DISTRIBUTORS LLC
Evaporators For Air Conditioning
COMMERCIAL REFRIGERATION
Oil Pressure Problems What to look for.
STEAM HEATING.
…an innovative shell and tube heat exchanger with an exceptionally high heat transfer coefficient for industrial fluid cooling and air conditioning.
ENGINEERING YOUR SUCCESS. PDF Market and Sales Meeting Refrigerated Dryers.
Solar cooling systems.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Air Conditioning in tropical climates Presented by Ranjeet Kumar Nayak.
Hawke’s Bay Refrigeration
Objectives Finish with compressors Learn about refrigerants and expansion valves (Ch. 4) Start with heat exchangers.
© 2008 Data Power Services, LLC By: Tom Taranto 2010 Energy Expo Hosted by National Grid NYSERDA Reducing Compressed Air Energy Cost Using a Systems Approach.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Refrigeration Basics 101.
The Refrigeration Process
David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.
Objective Discuss Expansion Valves and Refrigerants Heat Exchangers Learn about different types Define Heat Exchanger Effectiveness (ε)
Pressure-Enthalpy and the Variable Refrigerant Cycle
Facilities Management and Design Chapter 7 HVAC Systems.
Large Tonnage Chiller WC Screw.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Introduction to Energy Management
Refrigeration Systems
CLASSIFICATION OF HEAT EXCHANGERS
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Heat Transfer and Refrigeration Cycle
TXV Devices.
GROUND SERVICING OF VARIOUS SUB SYSTEMS
. Level 3 Air Conditioning Inspections for Buildings
Heat Transfer and Refrigeration Cycle
GROUND SERVICING OF VARIOUS SUB SYSTEMS
DESIGN AND DEVELOPEMENT OF AIR CONDITIONING CUM WATER COOLER
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Heat Transfer and Refrigeration Cycle
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
What is Desuperheater Water heater and its Applications?
Cooling technology Main components and equipments
The Basic Direct Expansion Refrigeration Cycle
Refrigeration Basics By: Mohamed Iqbal Pallipurath.
Desuperheater Heat Transfer Device Manufactured by Maniks
ICE 101 REFRIGERATION BASICS
Process Equipment Design and Heuristics – Heat Exchangers
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Refrigeration and Air Conditioning
Refrigeration and Air Conditioning
Air Treatment School Refrigerated Dryer Training
Presentation transcript:

XDX® A Discussion Concerning Heat Exchangers: Shell and Tube Plate and Frame

A.R.M.E.D. ® Technology A.R.M.E.D. (Adjustable Refrigerant Metering Evaporator Device) helps improve the effectiveness of the Mysticool® Max. It works in tandem with X-Stream® Technology to improve the characteristics of refrigerant flow throughout the entire evaporator coil. A.R.M.E.D.® helps fine-tune the system by allowing regulation of the refrigerant flow through pressure drop. It also permits the fine adjustment of liquid flow into the valve, which allows the correction of overfeeding and underfeeding. It is designed with multiple orifice settings and is installed directly after the expansion valve, replacing the distributor orifice. X-S TREAM ® Technology X-Stream® Technology is the main component of XDX® technology. It was developed with the mindset that heat transfer is the most important aspect of cooling and that vapor has a role to play in the refrigeration system. The technology optimizes the refrigerant flow and the resulting heat transfer capability with the evaporator by using vapor refrigerant to force a film of liquid refrigerant around the circumference of the inner walls within the evaporator tubing. The result is unparalleled performance, superheat stability and more consistent evaporator surface temperatures, which minimizes frost build-up and expedites pull-down temperatures. T echnology Click Here for view of Patented XDX® ABF HVFT Annular Flow

Pre-Retrofit

Conventional

Post-Retrofit

XDX®

A Typical Chiller Piping Diagram

XDX® is retrofitted or factory installed downstream of the EEV or TXV

System Degradation Spectrum XDX Performance Efficiency Enhancement in Systems Based on Age of Unit XDX dramatically increases system sustainability Conceptual Discussion on

Wineries Attention to detail Producing a high quality wine takes time and attention to detail. And one of the key components in this process is refrigeration. From the fermentation period, when cooling coils are necessary to keep the grape juice at a consistent temperature; throughout the cold-stabilization process, when the time-to-temperature relationship can affect profitability; and into the higher loads of the exothermic period during harvest, refrigeration is paramount. Controlling the process Any variance in refrigeration performance during the winemaking process can have a disastrous effect. Quality is at stake when equipment cannot perform to expectations during warmer temperatures, or when the temperature control is less than desirable. And the high cost of the energy necessary for refrigeration can have a negative effect on the profitability of the winemaking venture. © XDX Innovative Refrigeration, LLC Secondary Loop and Refrigeration with XDX®

Artesa Vineyards Location: Carneros, Calif. Innovative refrigeration helps winery save energy while producing quality wine It is the dedication of a winery to detail that produces a great wine. One visit to Artesa Vineyards in Carneros, Calif., and the attention directed toward detail is evident. From the modernistic architectural design and the glass masterpieces of a local artist, to the great effort to blend the facility into the natural terrain, this 400-acre-facility radiates detail. Challenges: Refrigeration plays an important role in wine production. From the fermentation process, where cooling coils are necessary to keep the grape juice below 30 degrees Celsius; throughout the cold-stabilization process, when the time-to-temperature relationship can affect profitability; and into the higher loads of the exothermic period during harvest, the importance of consistent temperatures is a main focus. Refrigeration issues often are noticed only when the equipment cannot perform to expectations during warmer temperatures, or when the temperature control is less than desirable. Artesa had discussed possible improvements and equipment additions that would provide the needed performance as well as reduce energy costs. When they learned about a Pacific Gas and Electric project that featured an energy-saving technology from XDX innovative Refrigeration, they decided to give the new product a try. © XDX Innovative Refrigeration, LLC

Refrigeration: Chillers Chiller as Historically Operated (Left) and unable to cool uniformly until after the installation of XDX®. At the right is the post installation operation with XDX®

What we delivered: XDX X-S TREAM ® valves, which improve evaporator performance and deliver more consistent temperatures, were installed in the existing refrigeration system at Artesa. The improvement in evaporator performance has had dramatic and beneficial results. Results: The plant maintenance engineer reports a significant improvement in how quickly the tanks get cold—and stay cold. As a result, the cold-stabilization process takes less time. The winery can now run up to eight of its 10,000-gallon tanks at a time. In addition, refrigeration compressors cycle off more often, which delivers a significant energy savings and helps maintain the winery's high quality while managing overhead. © XDX Innovative Refrigeration, LLC What our clients have to say: "I want the highest quality and to get the highest quality, we must focus on every detail of the process. Having the refrigeration work as well as it does allows us to focus on the product What all quality winemakers have in common is that we need control of the process. XDX has helped us in the control of the process."—Artesa winemaker Don Van Staaveren

The transient response test indicated that the time to reach a temperature of 44◦F with the XDX valve at the entrance to the evaporator was approximately one-half the time required to reach the same temperature without the XDX valve. Refrigeration: Chillers Standard Refrigeration is a leading Chiller Vessel OEM in the U.S.A. Standard Independently Validated XDX®

DX Shell and Tube Evaporator Bundled TubesHeader for Tubes

The working Principle of A Shell and Tube Heat Exchanger

Thermal Imaging A Shell and Tube Heat Exchanger

Typical Design Logs Oil and Unnecessary Superheat Wastes Energy XDX® Operation allows Oil to return and Tightly Controls Superheat to Save Energy Getting the Best Performance from A Shell and Tube Heat Evaporator XDX®, once installed will return gallons of oil to the compressor, improving heat transfer, lubrication, capacity, and efficiency. Typical operation logs oil,, as much as 11%, inhibiting its return to the compressor. This reduces heat transfer, lubrication, capacity, and efficiency.

The working Principle of A Plate and Frame Heat Exchanger

Plates allow for refrigerant flow on one side, and a secondary medium on the alternate side of each plate. Each brand of heat exchanger attempts to direct flow through varying patterns of openings and passage ways.

Plates Plates allow for refrigerant flow on one side, and a secondary medium on the alternate side of each plate, using gasketing material to isolate flow.

Thermal Imaging Identifies a Lack of Uniformity to Refrigerant Flow

As is consistent with the thermal imaging, the plate has an area of typical flow pattern and mass flow

As is consistent with the thermal imaging, the plate has areas of poor flow patterns and weak mass flow

The plate also has areas of minimal flow patterns and poor mass flow; these areas log oil As much as 9% of the heat transfer surface can be inhibited by Oil logging

X-Stream® Technology from XDX® provides the plate with a more uniform flow pattern Flow is improved, Oil logging is minimized with XDX® Flow is variant and Oil logging is typically prevalent