IAQ Building 6 Basement. Initial Request To January 3, 2012

Slides:



Advertisements
Similar presentations
1 Construction and Renovation Activities in Healthcare Facilities What construction crews should know, but were afraid to ask!
Advertisements

PowerPoint ® Presentation Chapter 15 Troubleshooting and Mitigating IAQ Problems Troubleshooting and Mitigating IAQ Problems Overview of Non-IAQ Problems.
Managing Sickness Absence and Concerns Presented by HR Consultancy January 2013.
Ideal Practice Workflow Revenue Maximization and Cost Efficiency Contact us : 2222 Morris Ave. 2nd Floor, Union, NJ Ph: (908)
GENERAL EXPECTATIONS FOR SUCCESSFUL GRADUATE STUDENTS Graduate School: It’s Not Like Undergrad.
Medication Therapy Management The Patient and Provider Variables.
Healthy Homes in Rural Alaska
Indoor Air Quality Awareness Tulane University - Office of Environmental Health & Safety (OEHS)
MU Building Emergency Coordinator Training
Lead and Healthy Homes Program Wilkes Barre Office 57 N. Franklin Street Wilkes Barre, PA Ph: (570) Harrisburg Office 2645 N. 3 rd Street.
U.S. Department of Labor Occupational Safety and Health Administration Directorate of Science, Technology and Medicine Office of Science and Technology.
IAQ in Schools Responding to Inquiries, Complaints, and Requests for Assistance.
05/19/051 Facilities Service Division Mold Training May 19, 2005 Office of Environmental Health & Safety Los Angeles Unified School District.
How Much Lime Is in Limestone By Mary Sue Burns Pocahontas County High School 1.Place students in small groups. Each group will need beakers, supply of.
Region 9 Healthcare Coalition Ebola Symposium April 23 rd, 2015.
Tulane University - Office of Environmental Health & Safety (OEHS) DEPARTMENTAL SAFETY REPRESENTATIVE (DSR) EXPECTATIONS Information For Tulane Employees.
ASTHMA SMART SCHOOL TRAINING FOR DAYCARE PROVIDERS
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Phone No: Air Conditioning Maintenance Checklist.
Indoor Air Quality Trina Redford Industrial Hygienist National Naval Medical Center IH Services North.
ACT 96 - Indoor Environmental Quality In conjunction with the requirements directed under WI Statute and Administrative Code, school building officials.
27th July 2009 OHC - Kirloskar Pneumatic Co. Ltd. H1N1 (Swine) Flu Update 1.
NC A&T STATE UNIVERSITY
Indoor Environmental Quality: Investigating the Problem
HOMELAND SECURITY ADVISORY SYSTEM. Established after the terrorist attacks on America September 11, 2001.
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ.
HVACR416 – Design Effects of IAQ Problems. The effects of IAQ problems are often non-specific symptoms rather than a clearly defined illness. Symptoms.
Case Histories John W. Martyny, Ph.D., CIH Tri-County Health Department.
Seasonal and H1N1 Flu Guidance on helping Child Care and Early Childhood Programs respond to Influenza Season September 17, 2009 Presented by: Leona Davis.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
The First Six Months April - September Who is The Advocate Appointed Advocate March 2014 Led BC’s largest not-for-profit delivering homecare,
Employee Services Understanding Benefits of State Employment Utilizing available services towards achieving Work/Life balance.
Presented By SLAC and Hensel Phelps Welcome SUSB.
D1.HCC.CL2.04 Slide 1. Maintain strategies for safe food storage Assessment for this Unit may include:  Oral questions  Written questions  Work projects.
1 FSIS Notice Notice of Reassesment for E. Coli O157:H7 Control And Completion of Checklist for all beef operations.
TouchPointCare Managing Care Transitions to Reduce Unplanned Readmissions for patients with Heart Failure, MI & Pneumonia.
EHS Strategy Map Key EHS Opportunities Stakeholder Involvement Learning & Growth Effective Processes Industrial Hygiene Facility Management Facility Engineering.
9 th ACG Cross-Training Seminar Precautionary Measures during Outbreak of SARS (2003) Hong Kong Securities Clearing Company Limited 5 th July 2007 – Kuala.
Peer Counseling. Have confidence in your abilities. Know that your supervisors have confidence in you. Know that you are not alone and have resources.
Ebola Virus Disease (EVD) Tabletop Exercise for Hospitals
218B Area and Division Governor Training Maintaining Strong Clubs.
Estimation of the risk factors in chronic respiratory diseases of the children Cebanu Sergiu State Medical and Pharmaceutical University “Nicolae Testemitanu”
Nutrition. Triggers for Nutritional Services Referral  Growth and Weight Management  Health Conditions  Needs for Specialized Supports  Economic Problems.
Lab design Assignment 3 Unit 2.
V3 vs. v4 New Protocols for LEED Tommy Linstroth, Principal.
Welcome Managing concerns and complaints How should schools handle complaints? This session links to guidance from the DfE and local authorities, and looks.
Durham VA Medical Center Animal Research Program Lessons Learned.
Implementation Logistics What we used to do What we did this year How it turned out What we would do different.
Putting the Super in Supervision Dr. Mark Matthews, Student Learning Development.
Division/Group Supervisor, Roles and Responsibilities.
Targeted Food Safety Assessments Barb Masters OFW Law September 2015.
“NEXT STEPS” BIE FAMILY ENGAGEMENT Facilitated by:
ANNEXE OFFICE CONVERSION. Heating Operation Two gas fired boilers provide hot water to two separate circuits, a constant temperature circuit and a variable.
Transforming Passive Rotations Blake Fagan, MD Lisa Ray, MD MAHEC Family Practice Residency Program Asheville, NC April 2012.
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
Patient Experience Paul Jebb Assistant Director of Nursing Patient Experience.
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
Part 13 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Respiratory Protection – Half and Full Face Cartridge Respirators Training on the use of respirators in the workplace – module 2 Developed by the Division.
Maintaining Clean Air in the Classroom
洗手及 负压技术 余 波
Tri-County Health Department
IAQ Efforts on the Nez Perce Reservation
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Mount Vernon Community School
Institute for Tribal Environmental Professionals Indoor Air Quality in Tribal Communities Introduction to Mold Mansel A. Nelson June 2011.
Unfilled Positions FWEA Meeting March 18, 2019.
Presentation transcript:

IAQ Building 6 Basement

Initial Request To January 3, 2012

Industrial Hygiene Responds January 9, 2012 Mold sampling conducted Noted very dusty conditions and recommend a thorough cleaning Notice the supply air vents are blocked with Plexiglas Decided to come back with the IAQ Meter to take further measurements (CO2, CO, Temperature, humidity)

Industrial Hygiene Responds January 9, 2012 Industrial Hygiene notifies the EHS Coordinator of the complaint and the blocked supply vents. EHS Coordinator determines multiple work- orders were placed by the group to have the heat fixed. Works with the Facilities and Security Supervisor for Chemistry to more actively engage Facilities about the problem.

January 6 Mold Sampling

January 11 to 20 CO2

Jan 11 to 20 Temperature

Jan 11 to Jan 20 RH

Symptoms (In Last 6 Months) Fatigue 1 case of pneumonia Headaches Nose bleeds Vertigo

Supply Air Vents All room vents blocked Reheat coils not functioning Cold air blowing on students Multiple work- orders placed by the group to have the heat fixed

Supply Air Vents Work-orders placed on: 9/28/10 10/6/10 4/22/11 Does not include “repeated phone calls” On 4/27/11 the student decides he is not having success with the work-order process and finds a Facilities Comments form on the web and submits another request.

Supply Air Vents Facilities technician informs group that reheat coils cannot be fixed. Facilities suggests as a solution they can cover over the supply vent blowing on the student.

Supply Air Vents Reheat Coils Fixed Vents Unblocked On or Around January 23rd

January 26 Mold Sampling

February 2nd Industrial Hygiene revisits the space to assess the air using the IAQ meter.

February 2 to February 9

MIT Medical Industrial Hygiene contacts MIT Medical on February 6 to inform Dr. David Diamond of group members suffering from adverse medical conditions that they believe are related to the office space On February 13, Dr. Diamond visits the space and talks with some of the occupants.

Action Taken It is recommended to seal up a trough in the floor that may be prone to flooding (and consequently prone to mold growth) Biosafety conducts another round of mold sampling on that day Biosafety submits a work order to Facilities to have the fan coil units checked to ensure they are not clogged, moldy, etc.

Fan Coil Units Facilities reported the fan coil units had not been put on a PM schedule and were not being serviced. New filters installed.

February 13

Actions Taken Gone from essentially no air flow to fresh supply air entering the space, and significantly lower CO2 levels. Established that there is no mold problem Had the fan coil units serviced and put on a regular PM, so room temperature can be maintained. Also loaned the group a HEPA filter unit Informal visits indicated that the original students that complained felt like the air was better

April 2, 2012 Two new lab group member s EHS members involved and complain of being “more fatigued than usual”. On April 3 we meet with the group members and conduct another round of air sampling with the IAQ meter and another round of mold sampling.

April 3 Mold Sampling

April 3 to April 4

April 4 The Facilities and Security Supervisor for Chemistry is asked to arrange with Facilities to have the volume of supply air tested.

April 8, Students Meet with Dean For Graduate Education 4 people report chronic fatigue, balance impairment, vertigo, CNS infections, pneumonia, sinus infections “Went unreported by EHS, despite air quality complaint SOP mandating reporting of this to MIT Medical” “Students notifying occupational health themselves” “Months without any response to health concerns” “Randomly removing air filters; high mold levels led to mandatory HEPA filter installations, residual flooding” “No tests or quantification of mold levels, allergens, air quality, despite repeated requests”

Air Flow in Basement

Ongoing Issues Complaints of rust in the water led to a request to have the water tested… A second round of water testing involving glycols…

Lessons Learned Make sure researchers know who to contact if they are having trouble getting facilities to fix something. At the first report of “medical issues” refer to MIT Medical, and give MIT Medical a heads-up Communication is key!!!