Overview of Hygrothermal Modeling and Demonstration of WUFI ® Presented to: The Atlanta Building Enclosure Council July 11 th, 2012 Bryce McQueen.

Slides:



Advertisements
Similar presentations
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
Advertisements

Congress for the New Urbanism is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned.
EarthCraft: Insulating Strategies Energy Efficient Insulation Systems by Church Hill Homes.
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
PERFORMING EFFECTIVE BUILDING SYSTEM RECOMMISSIONING STUDIES Joseph J. Watson, P.E. Booth # 312.
1 Trade Skills HVACR116 Fiberglass Duct Board and Insulation Material.
“Do not take anyone’s advice as to how this building should be assembled.”
“Sustainable Building Systems and Construction For Designers” Chapter 7: Walls.
Building Enclosure Moisture Management Institute (BEMMI)
The House as a System 1. Systems in a Home Electrical Plumbing Comfort Control (HVAC) Structural Moisture Control Air Infiltration Thermal Insulation.
WALTER SCARBOROUGH CSI CCS CCCA SCIP AIA D+D Specifiers Series Sponsored by Air Barriers.
New Models for Interstitial Condensation
Assumptions about Indoor Environments Mark Lawton P.Eng Patrick Roppel M.A.Sc.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Moisture Barriers WEATHERIZATION INSTALLER/TECHNICIAN FUNDAMENTALS.
Rainscreen Performance Monitoring: Continuing Research Current Masters Thesis Research Highlights Presented by: Graham Finch, Dipl.T, BASc University of.
The House as a System 1. Air Temperature and Water Vapor.
Building Enclosure Commissioning (BECx): Practical Project Implementation.
Infrared Thermography and The Building Envelope Regardless of the building type involved, infrared thermography can provide remarkable, nondestructive.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
EPA-Review-7/ VOC Emission Characterization and CHAMP Development o EPA03 Thrust 1: Material Emissions and Pollutant Transport in Building.
Chapter 3: The House as a System To be used with the Guide to Building Energy Efficient Homes in Kentucky.
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
Chapter 27 Insulating Structures. Objectives After reading the chapter and reviewing the materials presented the students will be able to: List the ways.
The Buildings Envelope.  R Values are the thermal resistance of a building product. R values are given to certain materials to evaluate there ability.
ARCH-432 Vapor Retarders and Air Barriers Attendance In what modern day country was the first cavity wall developed and used? For what purpose? A. Spain.
“Insert Company Name” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion.
Unit 2 Terms & Definitions.  Legal requirements designed to protect the public by providing guidelines for structural, electrical, plumbing, and mechanical.
Objectives Compare locations in North America Potential for moisture problems Different driving forces Analyze potential for moisture problems in cooling.
Contribution to Annex 65 - EASEE Project -
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Proudly presents. At the conclusion of this course, participants should understand the following: General design methods for masonry construction that.
Moisture Transport Quantitatively and qualitatively describe transport by 1.Liquid flow 2.Capillary suction 3.Air movement 4.Vapor diffusion.
Variable-Speed Heat Pump Model for a Wide Range of Cooling Conditions and Loads Tea Zakula Nick Gayeski Leon Glicksman Peter Armstrong.
Water Management in Commercial Window Systems Ritz-Carlton Hotel St. Louis, MO.
USGBC NY Upstate Chapter R333 Domestic Hot Water: Usage Research DHWUR Hugh Henderson March 22, 2014.
Construction Joints Head of Wall Deflection Systems An AIA Continuing Education Program Credit for this course is 1 AIA/CES Learning Unit for HSW credit.
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Presenter’s Name Title Company Session Title Here Optional: Insert Company Logo.
Air Leakage and Water Vapor Control Chapter 6. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
SELECTING INSULATION MATERIALS  Insulation can serve as more than just an energy barrier, providing fire resistance, humidity control, and noise reduction.
3/11/2004 Objectives Analyze potential for mold and condensation in different climates and different building types Describe moisture transport in buildings.
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
Objectives Compare locations in North America Potential for moisture problems Different driving forces Analyze what motivates building codes Read Lstiburek.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Development of a new Building Energy Model in TEB Bruno Bueno Grégoire Pigeon.
CEFPI is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this.
© 2011 Autodesk Vasari Talk – How accurate is Vasari? Wednesday 11 th October 2012.
INTRODUCTION TO SOPREMA
©The Dow Chemical Company 2015
Improving Building Hygrothermal Performance through Advanced Application of Building Materials: a Holistic Approach towards Mould Growth Prevention.
Heat Loss and Gain Civil Engineering and Architecture
F-118 June 29, 2016 Association for Learning Environments
Mikael Salonvaara, Andreas Nicolai, Hui Li, Jensen Zhang
VOC Emission Characterization and CHAMP Development
Thermal mass dynamics 1.00 Heat absorption
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Conduction Cooling Loads
Experimental Investigation of
Educational Overview Revised 6/13/2017
Water-Resistive Barriers: Assuring Consistent Assembly Water Penetration Resistance Educational Overview Revised August 31, 2018.
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Civil Engineering and Architecture
Heat Loss and Gain Heat Loss and Gain
Building Energy Efficiency & Indoor Environmental Quality
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

Overview of Hygrothermal Modeling and Demonstration of WUFI ® Presented to: The Atlanta Building Enclosure Council July 11 th, 2012 Bryce McQueen

Continuing Education Quality Assurance “Wiss, Janney, Elstner Associates” is a Registered Provider with The American Institute of Architects Continuing Education System (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES for AIA members. Certificates of Completion for both AIA members and non-AIA members are available upon request. This program is registered with AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

Learning Objectives This presentation will provide an introductory level discussion of concepts associated with heat and moisture transfer through building enclosure assemblies and provide a demonstration of the use of one-dimensional hygrothermal analysis software known as WUFI ® (Wärme und Feuchte instationär). After attending this presentation participants will be able to: 1.Discuss the basics of hygrothermal modeling concepts and techniques 2.Discuss moisture transport and storage fundamentals and hygrothermal phenomena in building materials and assemblies 3.Discuss moisture control performance criteria for building facades, including ASHRAE Standard Criteria for Moisture Control Design Analysis in Buildings. 4.Describe a case study demonstration of WUFI ® 5.Discuss the basic general capabilities and limitations of hygrothermal modeling software such as WUFI ®

Hygrothermal Modeling Hygrothermal Change in properties due to moisture absorption and temperature change Hygrothermal Modeling Dynamic simulation of moisture and heat transport through multi-layer building components over a period of time Benefits Provides opportunity to simulate exterior wall hygrothermal performance (without air flow) for comparative purposes Can be used as a tool to confirm design decisions (within the limits of the software) for wall assemblies in various climatic conditions Does not require destructive investigation or significant resources to perform, however, confirmation of simulation results are recommended

Environmental Data Monitoring Actual hygrothermal conditions of an assembly using environmental data loggers

Environmental Data Analysis Analysis of hygrothermal conditions using environmental data loggers Benefits Actual results (not predicted) that can be verified Continual wireless monitoring Drawbacks Significant Cost Time for Analysis Interruption of facility operations Destructive methods required for installation Possible equipment failure Sudden environment changes (i.e. opening windows or ceiling tiles) can affect results

Hygrothermal Analysis Benefits Dynamic view of modeled results depicting temperature, relative humidity, dew point, and water content values over time Analysis time is relatively short Non-destructive analysis (except in instances of as- built verification) Drawbacks Results are not actual Numerous limitations apply (discussed later) Verification of as-built conditions and results is still recommended in most instances

Hygrothermal Model Inputs Assembly Data Materials – Material Data – Hygrothermal Functions Additional Data – Heat Sources – Moisture Sources – Air Changes Surface Transfer Properties Orientation Inclination Height Permeance Absorptivity Heat Resistance Initial Moisture Content Exterior Macro Climate Historical Climate Data – Air temperature – Air humidity – Short wave radiation – Long wave radiation – Precipitation – Wind velocity and direction – Optional: measured data Interior Climate Air temperature Air humidity Time Simulation Duration

Fundamentals of Moisture Transport/Storage Moisture is present in the air both inside and outside the building envelope and may be in the form of solid ice, liquid, or vapor Moisture is driven through the building envelope by natural forces such as: – Temperature – Partial vapor pressures (sometimes expressed in terms of relative humidity) – Liquid pressure (suction forces) caused by rain water, water leaks, or surface condensation. If moisture accumulates above a critical material-dependent threshold, the building components begin to: – Stain – Rot or degrade – Crack or spall – Corrode – Accumulate mold Damage is in many cases related to the inability of the building owner to control moisture within acceptable limits

Fundamentals of Moisture Transport/Storage Basic Material Properties Bulk Density (lb/ft 3 ) – Easy to Measure, known for most materials – Needed for internal conversions (heat capacity, water content) Porosity (ft 3 /ft 3 ) – Describes the maximum water content of the material – Needed when a material can absorb vapor or water in its pore structure Permeability (Perm in) Specific Heat Capacity (BTU/lb degF) – Sum of the dry material and the amount of bounded water Thermal Conductivity (BTU/h ft degF) – Dependent on density, temperature, and moisture

Hygrothermal Phenomena in Building Practice Optical degradation Soiling, Staining Microbial Growth Efflorescence

Hygrothermal Phenomena in Building Practice Damage caused by elevated water content and/or condensation Freeze-Thaw Cycle Trapped Moisture Corrosion Rust Jacking

Hygrothermal Phenomena in Building Practice Damage by hygrothermal stress Shrinkage cracking Damage from hygrothermal dilatation (i.e. spalling, delamination, etc.) Coating failures

Hygrothermal Phenomena in Building Practice Health aspects Hygrothermal comfort Air quality Mold growth caused by elevated surface humidity

ASHRAE Standard Criteria for Moisture Control Design Analysis in Buildings Design Criteria for Moisture Control in Buildings Purpose To specify performance-based design criteria for predicting, mitigating or reducing moisture damage to the building envelope, materials, components, systems and furnishings, depending on climate, construction type, and HVAC system operation Scope – Design of new buildings and retrofit and renovation of existing buildings – All types of buildings, building components and materials – All interior and exterior zones and building envelope cavities – Does not address thermal comfort, acceptable indoor air quality, or the design of building components to resist liquid water leakage (reference ASHRAE Standard 55 Thermal Environmental Conditions for Human Occupancy

Moisture Performance Criteria Mold (according to ASHRAE Standard , with 2011 Addendum) 30-day running average surface RH > 80% or 7-day running average surface RH > 98% or 24 hours at 100% and Surface temperature between 50° and 104°F Surface Condensation Determined using Dew Point Analysis (which can be calculated through WUFI)

What is WUFI? WUFI-ORNL/IBP is a menu-driven PC program which allows realistic calculation of the transient coupled one-dimensional heat and moisture transport in multi-layer building components exposed to natural weather. It is based on the newest findings regarding vapor diffusion and liquid transport in building materials and has been validated by detailed comparison with measurements obtained in the laboratory and on outdoor testing fields.

WUFI Case Study Wall Assembly Case Study Atlanta, Georgia Building Background Building operates as a hotel Construction completed in 1987 Building contains 12 stories above grade Typical construction consists of cold-formed metal stud infill walls and brick veneer with aluminum storefront windows in punched openings Water leakage and interior mold growth reported prior to project Initial Investigation Exterior and Interior Visual Surveys Roof Condition Assessment Water Leakage Testing Exterior and Interior Inspection Openings Supplemental Analysis Exterior Wall Vapor and Heat Transmission Analysis

WUFI Case Study Original Wall Assembly 1.3-5/8” red modular brick veneer 2.1-1/2” air cavity (non-ventilated) 3.1/2“ exterior gypsum sheathing 4.6” cellulose fiber insulation 5.5/8” interior gypsum wallboard 6.Vinyl wall covering Interior Design Conditions Summer – 72 degrees F – 60% R.H. Winter – 68 degrees F – 40% R.H.

WUFI Limitations Some Limitations WUFI is most commonly one-dimensional. Two-dimensional WUFI software is available but requires significantly more setup and processing time. Three-dimensional simulations using WUFI are not available Simulations do not account for additional materials or thermal bridges that may be present in an assembly (i.e. metal studs, structural framing, etc.) or material discontinuities (i.e. vapor or air barriers) WUFI assumes an ideal wall construction. Factors that may introduce additional moisture and/or air movement into the assembly (open sealant joints, open penetrations, deteriorated mortar joints, spalled brickwork, etc.) may change the performance of the wall assembly Moisture laden air flow cannot be simulated. Significant building problems may exist due solely to air leakage problems, and WUFI does not account for this Better simulations require accurate material data (certain materials may not be available in the database and some materials may not contain detailed material properties). Composite materials (i.e. OSB, Stucco) may require some manipulation or simplification. Additionally, accurate interior conditions may be hard to determine if design conditions are not provided

WUFI Limitations Additional Limitations WUFI does not take into account liquid transport via seepage flow through gravitation or hydraulic flow through pressure differentials (exacerbated through air leakage sources) WUFI is a good tool for studying the use of vapor barriers within an assembly, but introducing a double vapor barrier may not give accurate results Accuracy when introducing large air cavities is decreased due to the limitations of the software in dealing with convective vapor transport Modeling vertical and horizontal surfaces is fairly straightforward, but modeling soffit conditions can be tricky (must eliminate wind driven rain, solar exposure, and other conditions) Studying the application of coatings on exterior surfaces is useful and popular, but detailed material data for proprietary coatings can be difficult to come by and are not readily available in the database Air changes within air cavities and additional heat or moisture sources can be introduced into the model, but can be hard to accurately determine.

Questions / Discussion